| 1 | M & L for Section A: PIDS - Non-lethal Power Fence System:1 IP Energizer with LCD, onboard Programmable keys and Network controller (V1) Energizer with Charge controller in compliance with IEC 60335-2-76 & IS 8437 safety standards along with EMI standards videNo.: IEC 61000-3-2 & IEC 61000-3-3 complete all as specified and directed. |
| 2 | S& F Solar PV module of 12V / 74 Wp MNRE approved Indigenous and module mounted in anodised aluminium frame with twin wall profile structure all as specified and as directed. Note- Mounting structure along with foundation will be measured and paid separately(A) PV MODULES The PV modules must conform to the latest edition of any of the following IEC/equivalent BIS Standards for PV module design qualification and type approval: Poly Crystalline Silicon Terrestrial PV Modules:IEC61215/IS14286/ Equivalent IS (if available as on last date of receipt of tender) In addition, the modules must conform to IEC 61701 Salt mist corrosion testing, IEC 62804- Certification for PID resistance ,IEC61730Part1- requirements for construction &Part2-requirements for testing, for safety qualification or Equivalent IS(if available as on last date of receipt of tender)(B) Each PV module must use a RF identification tag(RFID),which must contain the following information:(i) Name of the manufacturer of PV Module (ii) Name of the Manufacturer of Solar cells(iii) Month and year of the manufacture(separately for solar cells and module) (iv) Country of origin (separately for solar cells and module)(v) I-V curve for the module(vi) Peak Wattage, Im, Vm and FF for the module(vii) Unique Serial No and Model No of the module(viii)Date and year of obtaining IEC PV module qualification certificate (ix) Name of the test lab issuing IEC certificate (x) Other relevant information on traceability of module as per ISO 9000 series. Note: RFID shall be mandatorily placed inside the module laminate.(C) Silicon Poly Crystalline SPV cells shall be used in the Solar Photo voltaic module. SPV cells used in the module shall essentially be indigenously manufactured (manufactured in India) of proven ability. Besides this SPV modules should also be essentially indigenously manufactured (manufactured in India). The make of SPV shall be Vikram Solar/ Tatawith Stand Branded Hot dip galvanized (85 microns) MS mounting structures to be used for mounting the modules/ panels/arrays. |
| 3 | Supply of Strobe light Red Colour, should start flashing in case of security breach, Lithium battery, ABS material, IP 65 Waterproof complete all as specified and as directed. |
| 4 | Supply of Fence light to indicate status of the Fence and the indication to be provided with the help of LEDs which should blink upon receiving HV pulses from Energizer complete all as specified and as directed. |
| 5 | S & F including testing & commissioning of 12V DC Hooter with 300m range (100 dB) IOTA complete all as specified and as directed. |
| 6 | S & F including testing & commissioning of 12V 65 AH battery, 2 year Warranty, high quality, excellent perfomance, durability and long life, backup energy for Energizers should be more than 24 hours complete all as specified and as directed. |
| 7 | S & F including testing & commissioning of fixing of lightening diverter kit ESE type with 4 metres consists of UV stabilized plastic and stainless steel components having provision to alter the arc gap, surface/wall mounted plate complete with necessary connecting up all as directed. |
| 8 | S & F including testing & commissioning of IP 56 rated out door console rack with rain canopy single door, one gland plate, two can locks and 3mm thick mounted plate fixed on mild steel angle ISA 25x25 with 3mm thick with minimum 1 mtr height above the ground complete all as specified and as directed. |
| 9 | S & F of intermediate posts of 2 mm thick KIWITAH (V shaped) duly galvanised of 45x25x2mm of 1.5 mtr length out of which 0.3 meter will be grouted on wall but not exeeeding 3mtr length as required at site complete all as specified and directed. |
| 10 | Supply and Fixing of Strain 50 NB Class B support GI post of 1.5 meter length duly galvanized complete all as specified and as directed. |
| 11 | Material and Labour fixing for 25NB class B 32 mm dia Support post hot dip galvanized to more than 60 microns to ensure protection against rusting, Length of the posts should be 1.5 meter out of which 300 mm will be grouted into the wall,complete all as specified and as directed. |
| 12 | Supply & fixof Breakaway Insulators UV stablized having break load of 25 Kg + 2 Kg suitable to 15 KV rating (dielectric strength) in power fence, made up of virgin Polypropylene Co-Polymer (PPCP) plastic material, superior design complete all as specified and as directed. |
| 13 | S & F including testing & commissioning of fixing of end strain hooks of 6mm dia made out of hard drawn spring steel/GI, suitable to fix strain insulator in power fence as required complete all as specified and as directed. |
| 14 | S & F including testing & commissioning of end strain insulators made up of Polypropylene Co-Polymer having 15 KV (die electric strength) working load more than 150 KG and UV stablized in power of 2.59mm dia in power fence as required complete all as specified and directed. |
| 15 | Supply & fix Joint clamps with Bolt and SS Nut as required complete all as specified and directed. |
| 16 | Supply & fix wire tightner LM6 grade for tightening of power fence made by pressure die casting with aluminum alloy lever andlocking mechanismcomplete all as specified and as directed. |
| 17 | S & F including testing & commissioning of HT fence wire 2.5 mm diameter, High tensile wire with minimum of 230 gms/sq.m zinc coating thickness having UTS of >140 Kg/sq.mm and break strength of 740 Kgs, complying with IS 398 Part 2 standards laying on wall not more than 5 mtr height complete all as specified and as directed. |
| 18 | Supply & fix Double Insulated cable with 2.5 mm dia GI wire, outer diameter of about 9 mm and withstand 15KV along with suitable PVC conduit Arrow Cables to connect Energizer to the physical fence complete all as specified and directed. |
| 19 | Supply of Warning sign board of 250 x 150 x 3 mm. Yellow background with Black color letters in Hindi on one side and English on the other side in compliance with IEC standards complete all as specified and directed. |
| 20 | Supply & fix Fence Earthing earthing complete with 8 mm dia SS rod electrode, buried directly in the ground (earth pit not less 1.20 m deep and 0.5 m in dia below ground level) with top edge of the plate not less than 1.2 m below the normal ground level, connected to system / fence earth lead by earth clamp to fix cable means of necessary bolts, nuts, washers of galvanised iron or steel upto 1 m length, 8 mm dia SS rod protected by and including GI pipe 40 mm dia bore of 4 feet length (medium grade ) and connected to main test point as directed including, combination of chemical mixture of around 6 kg of betonite powder for creating more conductive conditions for electric flow, including necessary excavation and brickwork and earth work in any type soil complete all as specified and directed. |
| 21 | S & F including testing & commissioning of fixing Gate top electrification with 1 mtr height fence on existing gate with required cabling, physical gate to be electrically isolated and proper strain insulators to be used for the same complete all as specified and directed. |
| 22 | S & F including testing & commissioning of fixing/ laying of 6 core armoured single mode optical fiber cable running through with 1” dia HDPE conduit pipe with all accessories complete as specified and directed.Note:- One running meter of Cat 6 OFC and one running meter of HDPE conduit shall be measured as one unit. |
| 23 | Supply and Fixing of PC Desktop, 500GB Hard disk, 2 GB RAM minimum, intel core 2 duo 3 Ghz or above, 10th generation processor 24\" LED Monitor / Display, graphics card 512 MB single VGA,complete with installed original latest version of CROWN Fence Secure software and suitable UPS having 10 miniutes backup, with optical mouse and keypad and provision with suitable stand / table as recommended OEM, complete all as specified and as directed. |
| 24 | Supply & fix electrical Tool Kit with (a) Digital Voltmeter to measure fence voltage upto 10KV, operating on a 9V battery, turns on instantly on detection of pulse along fence, with a fully insulated measuring probe and earth clip (b) Five light Tester indicating the fence health using five flashing neon lights, on/off based on voltage level without battery complete all as specified and directed. |
| 25 | Material & labour installation of angle Post as well as Fence erection, Cable laying following electrical safety measures including testing and Commissioning of Make: CROWN complete all as specified and directed. |
| 26 | Material and Labour for sub main wiring with 1.5 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS - 694), multistranded, unsheathed 1100 volts grade in PVC casing caping (heavy grade) of adequate size with all fittings and casing caping accessories of surface type including one run 1.5 Sqmm single core, green color sheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed make of Casing Caping :- (Notes for item :-(i) cable with one run earth wire and PVC casing capping shall be measured as one unit length.(ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately.(iii) Earth wire shall run inside the casing capping.(iv) Suitable color code of wire must be ensure for phase/neutral/earth.) |
| 27 | Supply & install testing and commmissioning outdoorLT electric panel ( KIOSK) consisting of double door, weather proof,separate compartment with locking arrangement, cubical panel floor mounting fabricated out of3.15 mm thick MS sheeton angle iron frameof 25x25x5mm and legs made of angle iron 36x36x6mm, painted with powder coated and precoted primer including necessory PCC foundation and earth work, provisioned with following (a) Bus bar chamber of 3 phase 4 strip415 volts with 400 Amps copper strip 1 setINCOMING:-(b) MCCB with thermal magnetic protection 200 AmpIcs=100% Icu 35 KA4 pole-01 NosOUTGOING:-(c) MCCB with thermal magnetic protection 100 AmpIcs=100% Icu 25KA 4 pole-04 Nos(d) Digital type Volt meter 0-500 Voltssquare typewith selector switch- 01 No.0-500 volt = 01(e)Digital type Ammeter 0-400 Amps square typewith selector switch- 01 No.0 -150 Amp = 01(f) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.(g) Complete internal wiring (h) Cable glands brass of suitable size for cable. Note:- Approval of GE must be obtainedfor Panel design/drawing and CPRI approval of manufacturer before placing order. |
| 28 | Material & Labour for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion 19474 Dilto, but using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20 mm dia GI watering pipe \"medium grade\", funnel with wire mesh, earthing chamber with cement concrete (1:3:6) type C-1, RCC chamber cover 80 mm thick (1:2:4) type B-1, excavating & earth work all asshown in electrical plate No. 3 of SSR (Part-I) and testing on completion complete all as specified and directed.Note:- Length upto 7.5m of GI strip is inclusive in unit rate complete all as specified and as directed. |
| 29 | M & L for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for HT, 250 mm X 200 mm complete all as specified and as directed. |