| 1 | SHEDULE - A (PART-I): PCC PAVEMENT AND DRAIN AT LAZU |
| 2 | Providing, spreading, laying hardcore of stone aggregate not exceeding 100mm & rolled with roller including watering 125mm thick. |
| 3 | Providing & laying in position PCC (1:2:4) A1 125mm thick of aggregate 40mm normal size. |
| 4 | Use & waste form work to sides of PCC. |
| 5 | Earth excavation in tranches not exceeding 1.5m wide & depth & getting out in hard/ dense soil. |
| 6 | Providing & laying PCC 1:3:6 type C2 as in drain. |
| 7 | Providing & applying 12mm thick plastering in cement mortar 1:4 and finish with floating coat of neat cement. |
| 8 | SHEDULE - A (PART - II) RR MASONRY AT LAZU, NOGLO, WAKKA & KUNSA |
| 9 | Earth work excabation in trench not exceeding 1.5 mtr deep in and getting out in hard/dense soil. |
| 10 | Providing and laying PCC (1:4:8) type D2 as in foundation. |
| 11 | Material & labour for random rubble masonary with hard stone foundation & up to plinth incl leveling up with cement concrete (1:6:12) with 20 mm aggregate & solidly hatred with cement mortar (1:6). |
| 12 | Ditto but in above plinth level. |
| 13 | Providing and laying PCC (1:2:4) type B1 as in copping. |
| 14 | Material & labor for bond stone (1:2:4). |
| 15 | Material & labor for bridge stone in PCC (1:2:4). |
| 16 | Material & labour for stone agger of gauge 40mm on brize stone. |
| 17 | Providing & applying raised pointing in cement mortar (1:4). |
| 18 | SSHEDULE - A (PART - III) PERIMETER FENCE AND SECUIRITY LIGHT AT WAKKA. & BNHQ AT KHONSA |
| 19 | Earth work in excavation in post and getting out in hard/ dense soil. |
| 20 | Providing and laying PCC 1:3:6 type-C2 in foundation. |
| 21 | Providing and fixing angle iron 50x50x6mm in post poles for fixing fillet with nuts and bolts. |
| 22 | Providing and laying GI chain link fence 4mm dia 50x50mm jail including strengthening with 2mm dia wire or nut bolt and washer dressed as contained. |
| 23 | Providing and fixing MS flat 40x6mm. |
| 24 | Providing and fixing GI barbed wire barbed at 75mm center to center. |
| 25 | Providing and applying two coat of syn enamel point over one coat of red oxide. |
| 26 | Providing and fixing nut bolt and washer for strut 10mm dia. |
| 27 | Providing& erection of MS electric pole 9 mtr height including cross arms of MS angle including painting 02 coat of aluminium paint over a coat of red oxide including PCC concrete below GL 1.5 mtr and, Above GL 1 feet height in PCC (1:3:6). |
| 28 | Supply and erection of stay set complete (GALVANISED with 19/20 mm dia x 1.8 mtr long stay rod, anchor plate of size 45 x 45 cm x 7.5 mm thimble, stay claim, turn buckle (20mm x 60 cm) 7/3.15mm dia G.I stay wire and strain insulated etc in cement concrete (1:3:6). |
| 29 | Providing & fixing ACSR conductor on pole 02 Nos 1 is 7,1/3.5mm and another is 7,2.259mm fixed on insulator proclaim pin type complete including 01 No earthing wire 6mm dia connect with earthing complete with earthing point. |
| 30 | Providing & fixing LED street light 60W and LED Light should be cover with MS sheet to protect from rain. |
| 31 | Providing & laying 3 ½ core aluminium conductor armored cable PVC sheathed. |
| 32 | Providing & fixing control panel made of 0.8mm thick mild steel including 50KLW MCCB and TPN change over switch 63 KVA Panel Box size 60 cm x 80 cm and stall on MS stand. |