Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-10-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-10-2024 |
| Sl. No. | Item Description |
| 1 | Dismentling of Bricks laid dry(laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer), complete all as specified and as directed. |
| 2 | Demolition of Mud Phuska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) disposing the rubbish to a distance exceeding 250 Mtr but not exceeding 500 Mtr away to low lying areas complete all as specified and as directed. |
| 3 | M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in copings, roof padding, staging of water tank, benching etc and similar nature of works mixed with water liquid proofing admixture as per manufacturer\"s instruction including finishing even and smooth using extra cement and rounded or chamfered on edges and necessary foamwork complete all as specified and as directed. Note :- (i) WPC shall be measured and paid separately.(ii) Ratesinclude to carried out the work on roof slabof building & nothing extra shall be admissible on this account). |
| 4 | M&L for 15 mm thick plaster in CM (1:4) mixed with water proofing compound on roof slabs finished even and smooth without using extra cement after cleaning of roof surfaces with wire brushes complete all as specified and as directed. Notes : WPC shall be measured and paid seperately |
| 5 | M & L for applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm including cleaning surface complete all as specified and as directed. |
| 6 | M&L for water proofingtreatment with polymeric water proofing membrane as under :-Supply and layingfive layer prefabricated Atactic polypropylene Polymer (APP) modified membrane of 3mm thick membrane (Weight not less than 3 Kg/Sqm) reinforced with 160gsm polyster non woven fabric with two coat of water proofing paint with alumnium finish on top including overlapping as per manufacturers instruction and complete all as specified and as directed. Note : APP membrane shall be laid on primed surface by Torch application method after allowing 24 hrs for Primer to dry. On Accesible roof where Brick tile is laid APP membrane shall not be painted. |
| 7 | M & L for Hydraulically pressed PCCtile plain of size 200x200x19/20mm machine made laid over & including cement mortar screed 15mm thick in CM 1:6 mixed with water proofing compound and jointed pointed in CM 1:3 complete all as specified and as directed. |
| 8 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified and as directed. |
| 9 | M&L for Rough Cast Plaster on Brick Walls consisting Under Coat of Cement and Sand Mortar 1:3 not less than 10mm thick and while it is still in Plastic state the Rough Cast Mixture consisting of Crushed Stone or Fine Gravel mixed of size 6mm with Coarse Sand and Cement in the ratio 1:1:1 shall be applied and finish Even, complete all as specified and as directed. |
| 10 | M&L for preparing newly Rough Cast plastered surfaces of Walls and applying Two Coats of acrylic Weather Coat Exterior Paintwith approved Tint over a coat of Primer (as per Manufacturer\"s instructions), complete all as specified and as directed. |
| 11 | M&L for Rendering (External) 15mm thick in Cement Mortar 1:4 on Brick Walls or on Concrete Surfaces, mixing WPC as per manufacturers instructions, Plastered Surfaces finished Fair and Even, complete all as specified and as directed. NOTE: WPC will be Measured and Paid under appropriate Item. Areaincludes in this items upto two stories of building. |
| 12 | Supply only integral water proofing compound complete all as specified and as directed. |
| 13 | M&L for rendering 15 mm thick onbrick work or concrete surfaces on walls in CM 1:6 finishing even and smooth without using extracement complete all as specified and as directed. |
| 14 | M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces on ceiling/ struts inpatches in CM 1:3. finishing even and smooth without using extra cement complete all as specified and directed. |
| 15 | Dismantling of stone slabs and tiles of any description or thickness in floors, approachs, dado/Partitionsetc complete all as specified and as directed . |
| 16 | M&L for granite (Black) stone slab 15-18mm thick machine cut and machine polised, in skirting, Kitchen platform/dado,in floor etc laid over cement screedjointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding the edges half round and polishing including pinning in brick/concrete wall to hold & support the vertical surfaces to granite work including drilling to wall & including screed bed 15 mm thick in cement mortar 1:4 complete all as specified and as directed. |
| 17 | S&F rotational moulded polythene, triple layers, water storage tank 500 Ltr capacity, closed top, cylindrical, hoisted and fixed in position incl S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed incl Dismantling water tanks Exc 250 Ltr & not exceeding 500Ltr complete all as specified and as directed. |
| 18 | S&F rotational moulded polythene, triple layers, water storage tank 1000 Ltr capacity, closed top, cylindrical, hoisted and fixed in position incl S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed incl Dismantling water tanks complete all as specified and as directed. |
| 19 | Dismantling Floor, Paver Tiles, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) and removing debris, etc. to Outside MD/AF Land, complete all as specified and as directed. |
| 20 | M&L for Polish Glazed Vitirified Ceramic colour Tiles 10mm thick (Square/Rectangular),Polished, area of each Tile not exc. 0.36 Square Metre in Floors, etc. set and jointed in Neat Cement Slurry and pointed in White or Coloured Cement to match the Tiles, laid over and including 15mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate. |
| 21 | M&L for Polish Glazed Vitirified Ceramic Tiles 10mm thick (Square/ Rectangular)Light shade, Polished, area of each Tile not exc. 0.36 Square Metre in Vertical Surface i.e. Dado, Skirting,etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including 10mm thick rendering in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Cement Mortar shall deem to be include in the Quoted Unit Rate. |
| 22 | M&L for non-skid tiles ceramic coloured tiles 7 to 8 mm thick of size 400mmx400 mm as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles including 15 mm thick screed bedding layers in CM (1:4) complete all as specified and as directed. NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate. |
| 23 | M&L for Coloured Glazed Ceramic Tiles 300x450x7mm thick in Vertical Surface i.e. Dado, Skirting,etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including 10mm thick rendering in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Rendering Cement Mortar shall deem to be include in the Quoted Unit Rate. |
| 24 | M&L for Coloured Glazed Ceramic Tiles 300x200x7mm thick in Vertical Surface i.e. Dado, Skirting,etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including 10mm thick rendering in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Rendering Cement Mortar shall deem to be include in the Quoted Unit Rate. |
| 25 | M&L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in floor finishingcomplete all as specified and as directed. |
| 26 | Dismantling damaged/unserviceable GI Snap Grid Ceiling Frame Work with Ceiling Boards of any description, complete all as specified and as directed. |
| 27 | S&F GI Powder coated GI Snap Grid Frame Work of size 605x605mm as in False Ceiling with supported hanging of Mild Steel Rod of\"J\" Bolt, complete all as specified and as directed. |
| 28 | M&L for 12 mm thick perforated particle board/ tiles for insulation and accoustic purposes, 60x60 cm in size,fixed with nails or with staple in ceiling/ timber frame complete all as specified and as directed. |
| 29 | Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sqm each, including cutting holes for removing the hold fast etc (Disturbed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified and as directed . |
| 30 | Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4 Sqm each, including cutting holes for removing the hold fast etc (Disturbed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified and as directed. |
| 31 | Taking down shutter of any description area exc 1.00 Sqm and not exc 2 Sqm each and removing from site complete etc complete all as specified and as directed . |
| 32 | S&F30mm thick flush shutter solid core construction with block board core and ply wood face panels, commercial type on both sides with mika with approved design complete all as specified and as directed. |
| 33 | S & F solid PVC doorframe of size 50mm x 95mm made out of5 mm single side prelam PVC sheet used instead of plain colour PVC sheet reinforced with Ms Squre Tube in opening etc complete all as specified and as directed . |
| 34 | S & Ffactory made PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded both side prelam PVC sheet instead of plain colour PVC \"C\" channelled having a PVC sheet strip of 20 mm wide stuck inside with solvent cement for siles and palin colour PVC sheet for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail : panelling of prelaminated PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, in the frame a site as per specification and drawing etc complete all as specified and as directed . |
| 35 | S&F roll formed galvanised prepainted steel section window/ventilater section of frame72x55 mmfixed to wall or concrete surface withMS hold fast (30X5mm section) 150 mm longmade, of galvanized steel powder coated and section of shutter 47x20 mm ,mulion section 72x50 mm (Base steel as per IS 513 \"D\" quality galvanozed as per IS 277 with zinc of 120 gms/sqm.) glazed shutter and wire gauge shutter prepare to receive wire mesh to the shutter(Double door shutter) with total coated thickness of 0.6 mm including powder coated grill / guard bars made of square bars 10mm dia at 150mm c/c Horizontal spacingfixed in MS flat frame (30x5mm) fixed to windows frame with screws,incl 4 to 5 mm thick sheet glass, 0.36mm stainless steel wire cloth with 1.40mm aperture necessary fittings and all builders hardware such as handles, tower bolts & stays etc. complete all as specified and as directed .Type-Eco 4000 series ref drg noCEAF/STD-191/2014 SH1/2&2/2 |
| 36 | S&F 1.25 mm thick pressed steel frame of size 105 X 60 mm for door with one ore more rebate includings necessary fixing lugs, hinges, locks strike plate, Filling the frame with cement concrete Type B-0 1:2:4 ( (12.5 mm granded stone aggregates)etccomplete all as specified and as directed . |
| 37 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 38 | M&L forbrick work with sub class \"B\" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM1:6 complete all as specified and as directed. |
| 39 | Demolition reinforced cement concrete in roofs, floors (other than ground floors), beams staircases, landing, chajjas, Shelves and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and as directed. |
| 40 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), including removal of rubbish outside MoD land, complete all as specified and as directed. |
| 41 | M & L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concretecomplete all as specified and as directed. |
| 42 | M&L for mild steel TMT bars 10 mm dia and over, cut to length and bent to shape required and binding with mild steel wire dia not less than 0.9 mm (annealed) complete all as specified complete all as specified and as directed. |
| 43 | M&L for reinforced Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in roofs, chajjas,Shelves, beams, lintels, Manhole coverscomplete all as specified and as directed. |
| 44 | M & L for Formwork to soffits of floor or roof beam, beam haunching, girders, lintels, cantilivers, shelves including supports, overhang, etc. also splays between floor and beams, for rough finished surface of concrete etc. complete all as specified and as directed. |
| 45 | Dismantling Structural Steel or Mild Steel Work of any description including Framed Truss, etc., complete all as specified and as directed. |
| 46 | Dismantling damaged/unserviceable Galvalume, Fibre Glass Reinforced Translucent Corrugated Sheeting,AC andFiber Sheeting of any gauge and thickness, complete all as specified and as directed. |
| 47 | M&L for Steel Work in Tubular Trusses including Special shaped Washer etc. complete using ERW or Induction Butt Welded Tubes, confirming to IS-1161-1979 Grade-240, complete all as specified and as directed. |
| 48 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 49 | S&F Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in Ridge, roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 50 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floors/fixed to wall including GI stack clamps complete all as specified and as directed. |
| 51 | S&F 110mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 52 | M&L for Cutting holes in brick walls Exc. half brick but not exc full brickbuilt in cement mortar or cement lime mortar and stone walls built in lime mortarfor inserting PVC Pipe 100mmand making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 complete all as specified and as directed. |
| 53 | Taking up or down galvanised steel water tubing 15mm bore fixed to walls or laid under floors or in any other position along with required connections etc complete all as specified and as directed. |
| 54 | Taking up or down galvanised steel water tubing 20mm bore fixed to walls or laid under floors or in any other position along with required connections etc complete all as specified and as directed. |
| 55 | M & Lfor 15mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls concealed and or laid under floors etc complete all as specified and as directed. |
| 56 | M & Lfor 20mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls concealed and or laid under floors etc complete all as specified and as directed. |
| 57 | M&L for Cement Concrete 1:2:4 (20mm graded stone aggregate) 40mm thick as in Flooring, finishing Cement Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. |
| 58 | M&L for preparation of new wooden surface of any description, not other wise described over 10 cm widht or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed . |
| 59 | S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed . |
| 60 | S&F aluminium anodised barrel tower bolt of extruded section 200mm size, stove enamelled black, withbolt complete all as specified and as directed. |
| 61 | S&F Aluminium handles, 150mm size cast type anodised complete all as specified and as directed. |
| 62 | S&F Double legged Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 140mm complete all as specified and as directed. |
| 63 | S&F stainless steel 75 mm long butt hinges for PVC door shutters and frames complete all as specified and as directed. |
| 64 | S&F in repairs 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and as directed. |
| 65 | S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe 20 mm bore complete all as specified and as directed. |
| 66 | S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe 15 mm bore complete all as specified and as directed . |
| 67 | S&F in repair angle valves fancy typechromium plated brass cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unionsfixed for 15 mm dia bore dia pipe or two in one angle valve whereever required complete all as specified and as directed . |
| 68 | S&F in repair Stop valves, cast copper alloy, screwed down , high pressure, with crutch or butterfly handles , screwed both ends for iron pipe or for unions, fancy type, chromium plated with long shank and cup ( concealed type) and fixed 15 mm dia bore dia pipe complete all as specified and as directed. |
| 69 | S&F in repair Bib taps, cast copper alloy chromium plated,fancy type with crutch or butterfly handle , screwed down , scrwed for iron pipe or for brass ferrule and fixed for 15 mm dia bore dia pipe complete all as specified and as directed. |
| 70 | S&F in repair 15mm bore Pillar taps fancy type, cast copper alloy, with long swan neck, chromium plated, screwed down high pressure, with or without lettered `Hot\" or `Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixedall as specified and as directed . |
| 71 | S&F Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back type)/ oval in shape with Waste Fitting Brass Chromium plated 32mm dia, PVC Waste Pipe 32mm bore (dia) of suitable Length, a Pair of Cast Iron Brackets duly Painted/ Erecting Stand including Cutting and Pinning in Ends, Making Good disturbed surfaces in Cement Mortar 1:3 and fixed-in-repairs, complete all as specified and as directed. |
| 72 | S&F One Piece Euorpen Water Closet Concealed of size 790x360x650mm Snow White, Soft Close Seat Cover having Twin Flush Fittings and Making Good to Floor/ distrubed Surfaces and fixed-in-repairs, complete all as specified and as directed. MAKE : JAQUAR SLS-WHT-6851S(WC),or eqivalent in CERA/ HINDUSTAN SANITARYWARE/ PARRYWARE (as approved by GE). |
| 73 | S&F Vitreous China White Squatting Pan of size 580x440mm, Orissa Pattern with Integral Foot Rests, ‘P’ or ‘S’ Trap, providing Joints between Flush Pipe and Socket of WC Pan, Cones, India Rubber (nozzles of WC Pan) incluiding provision of Lime Concrete Bedding and Making Good to Floor/distrubed surfaces and Fixed-in-repairs, complete all as specified and as directed. |
| 74 | S&F Vitreous China White Wash Down Water Closet Pan (Pedestal Pattern) with Trap and Fixing Bolts and Making Good to Floor/ distrubed surfaces and fixed-in-repairs, complete all as specified and as directed. MAKE : HINDUSTAN SANITARYWARE 21027/ JAQUAR CNS-WHT553SN/ PARRYWARE C-0252(S) or eqivalent in CERA (as approved by GE) |
| 75 | S&F Plastic Water Closet SeatCover for Water Closet Pan (Pedestal Pattern), White, Closed Pattern with Flat bottom and Cover and Mild Steel Chromium plated or Aluminised Hinging Device and fixed-in-repairs, complete all as specified and as directed. MAKE : JAQUAR CNS-WHT-111N or eqivalent in CERA/ HINDUSTAN SANITARYWARE/ PARRYWARE (as approved by GE) |
| 76 | S&F Health Faucet with Wall Hook, Chromium Plated having 1.00 Metre long with PVC Hose Pipe and fixed in repairs, complete all as specified and as directed. MAKE : JAQUAR ALD-CHR-585 or equivalent in GEM/ MARC (as approved by GE). |
| 77 | M&L for PVC Flushing Cistern 10 Litre capacity White, Low Level, Valve less, Syphonic action type with Inlet, Ball Valve, Float and Handle, PVC Waste Pipe 32mm bore (dia) of suitable Length, a pair of Cast Iron Bracket/ Erecting Stand duly painted including cutting and pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and Fixed-in-repairs, complete all as specified and as directed. |
| 78 | S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. |
| 79 | S&F in repair 600mm x 450mm mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with CP Brass screws and cup washers with aluminium beading all around complete all as specified and as directed. |
| 80 | S&F Brass Chromium Plated Tubular Towel Rail 20mm dia ‘D’ type60 Cm long with Brackets and Fixed-in-repairs, complete all as specified and as directed. |
| 81 | S&F in repair chromium plated shower roses 125 mm with or without swivel joints,any size including fixing to steel pipe or union for 15mm bore of pipe complete all as specified and as directed. |
| 82 | M&L for three coats of white wash on New plaster surface of ceiling including prepration of surface complete all as specified and as directed. |
| 83 | M&L for One coats of white wash on old plaster surface of ceiling including prepration of surface complete all as specified and as directed. |
| 84 | M&L for2mm thick white cement base putty and making the surface smooth etc, complete all as specified and as directed. NOTE:Areaincludes in this items upto 2 stories of building. scaffolding and other arrangement to be done by contractor, nothing extra shall be paid to contractor. |
| 85 | M&L for preparing Old plastered surface of walls and applying two coat of oil emulsion distemper white or any tint etc complete all as specified and as directed. |
| 86 | M&L for preparing Newplastered surface of walls and applying two coat of oil emulsion distemper white or any tint etc complete all as specified and as directed. |
| 87 | M&L for preparing old Decorated/Treated Plastered surfaces of Wallsupto two storey by brooming down or steel wire brushing and scraping down and applying Two Coats of Acrylic Weather Coat Exterior Paintwith approved Tint over a coat of Primer(as per Manufacturer\"s instructions), complete all as specified and as directed. |
| 88 | M&L for preparing newly Plastered surfaces of Walls upto four storey by applying 1 mm Wall Putty, cutting/rubbing to obtained a Smooth Surface and applying Two Coats of Acrylic Weather Coat Exterior Paintwith approved Tint over a coat of Primer (as per Manufacturer\"s instructions), complete all as specified and as directed. |
| 89 | M&L for preparation of old painted surfaces of wood & wood based surface of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed. |
| 90 | M&L for preparing old Treated/Painted Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed. |
| 91 | M&L for preparation of new steel surface of any description, not other wise described over 10 cm widht or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed . |
| 92 | M&L for RCC Pre-cast Cement Concrete 1:2:4 (12.5mm graded stone aggregate) as in Louvres and Jallies, 40mm thick (measured solid) with all mouldings including Reinforcement with 5.0-6.0mm dia Mild Steel Bars/ Wire and setting in Cement Morter 1:4 including dismantling Pre-cast RCC Cement Concrete Louvres and Jallies of any description, removing debris, etc. to Outside MD/AF Land, complete all as specified and as directed. NOTE : Cost of Mild Steel Bars/Wire as Reinforcement will deem to be included in the Quoted Unit Rate. |
| 93 | M&L for preparing new or previously untreated Plastered/ Concrete Surfaces of any description, not otherwise described, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality), complete all as specified and as directed. |
| 94 | M&L for Rubber Pressed, Glossy finsh Pre-Cast concrete interlocking coloured paving block of glass fibre reinforced vibro compacted any shape and size conforming to IS-15658:2006 of 60mm thickness made with M-35 grade concrete match with grey cement and pigment etc complete all as specified and as directed. |
| 95 | M&L for exterior grade, coloured glossyfinish rubber pressed, cement concrete designer chequered tiles of size 30cm x 30cm x 25mm thick( as approvedby GE) set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc laid overincluding 15 mm thick cement screed bed in CM 1:6 . complete all as specifed and as directed. |
| 96 | M&L for 20mm thick sand cushioning including watering and consolidations etc complete all as specified and as directed. |
| 97 | M&L for 50 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in sub base of floor complete all as specified and as directed . |
| 98 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking into credit and making good disturbed surfaces of walls, floors etc complete all as specified and as directed. |
| 99 | Takig down unserviceable sub main wiring of any type/size including wire.conduite/battens etccomplete all as specified and as directed. |
| 100 | Takig down unserviceable MCB DB\"s box/ of any size/rating complete all as specified and as directed. |
| 101 | M&L for point wiring complete with 1.5 Sqmmsingle core FRLS PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor as per IS732 (1989)drawn through non metallic rigid PVC conduit and accessories in surface of walls/ceilings/concealedin wall including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including 1.22 mm thick pressed steel terminal boxes of suitable thickness, 3 mm thicklaminated sheet cover to house switch/regulators etc complete all as specified and as directed:- |
| 102 | (a) One light point /bell point controlled by one switch with cable 1.5 Sqmm size complete all as specified and as directed. |
| 103 | (b) One fan point/Exhaust fan controlled by one switch with cable 1.5 Sqmm size complete all as specified and as directed. |
| 104 | (C) One llight point controlled by two way 6 Amps switch complete all as specified and as directed. |
| 105 | (d) One 5 pin socket outlet 5/6 Amps on Same board including singal core stranded copper conductor 1.5 sqmm PVC insulated and unsheathed cable drawn in same conduit as earth wire to the common earth and connecting to earth doily complete all as specified and as directed. |
| 106 | (e) One 5 pin socket outlet 5/6 Amps on independent board including singal core stranded copper conductor 1.5 sqmm PVC insulated and unsheathed cable drawn in same conduit as earth wire to the common earth and connecting to earth doily complete all as specified and as directed. |
| 107 | All as per item No 101 hereinbefore but with cable 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm stranded copper unsheathed complete all as specified and as directed. |
| 108 | All as per item No 101 hereinbefore but with cable 4 Sqmm and earth continuity conductor of 4 Sqmm stranded copper unsheathed complete all as specified and as directed. |
| 109 | Supply and fix in repairs switch piano type one way 6 Amps flush type ,240 voltAC complete all as specified and as directed. |
| 110 | Supply and fix in repairs switch piano type one way 16 Amps flush type ,240 voltAC complete all as specified and as directed. |
| 111 | Supply and fix in repairssocket2 in 1, 3/5 pin, 16 Ampsflush type ,240voltAC complete all as specified and as directed. |
| 112 | Supply and fix in repairssocket outlet 2 in 1,3 pin 5 Amps complete all as specified and as directed. |
| 113 | Supply and fix in repairsswitch piano type two way 6 Amps flush type ,240voltAC complete all as specified and as directed. |
| 114 | S & Fix in repairstepped type electronic fan regulator 120 watt ,240 oltflush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 115 | Supply and fix in repairs Bell push, flush type, 6 Amp flush type ,240voltAC complete all as specified and as directed. |
| 116 | Supply and fix in repair ceiling rose surface bakelite with three terminals complete including taking down rusted metal box and necessary platering work and finish with existing wall paint complete all as specified and as directed. |
| 117 | Supply & Fix Double poleSheet matel enclosure box with a two pin and earth plug and socket complete with singal pole MCB 20 Amps and including taking down complete all as specified and as directed. |
| 118 | Supply & Fix wall mounted extruded aluminium housing high quality indoor batten LED tube 20 watt (4ft long) colour temperature 6500 K (4\" long) lumen 2000 -3000, PF> 0.9, THD less 15%diffused connecting with three core flexible copper wire from connecto to ceiling rose/angle holder as per existing site requirement and including taking down complete all as specified and as directed. |
| 119 | Supply & Fix wall mounted extruded aluminium housing high quality indoor batten LED tube 10 watt (2 ft long) colour temperature 6500 K (2\" long) lumen 2000 -3000, PF> 0.9, THD less 15%diffused connecting with three core flexible copper wire from connecto to ceiling rose/angle holder as per existing site requirement and including taking down complete all as specified and as directed. |
| 120 | Supply & Fix Recess mounting LED flat panel light fitting 36 watt,2 x 2 , 600mm x 600 mm size with efficient LEDslumen 2000 -3000, PF> 0.9, THD less 15% including taking down unserviceable fitting of any type and including taking down complete all as specified and as directed. |
| 121 | Supply & Fix Bldg security light Supply and fixing in replacement of LED building light luminaire 35 watt,pressure dia cast aluminium housing with heat resistant toughened glass & IP 66 protection and including taking down complete all as specified and as directed. |
| 122 | Supply & Fix lamp holder,PVC/Polycarbonale type with black plate suitable for batten fitting including taking down complete all as specified and as directed. |
| 123 | Supply andfix in repairelectric bell Ding Dong,AC 230 volts and including taking down complete all as specified and as directed. |
| 124 | S & F sheet metal enclosures for double door distribution boardfactory made duly painted 8 way SPN and neutral 240 v with 200 amps rated bus bar , suitable for fixing MCB /Isolatorsand including taking down complete all as specified and as directed. |
| 125 | S & F sheet metal enclosures for double door distribution boardfactory made duly painted 8 way TPN and neutral 240 v with 200 amps rated bus bar , suitable for fixing MCB /Isolatorsand including taking down complete all as specified and as directed. |
| 126 | S & F sheet metal enclosures for double door distribution boardfactory made duly painted 12 way TPN and neutral 240 v with 200 amps rated bus bar , suitable for fixing MCB /Isolatorsand including taking down complete all as specified and as directed. |
| 127 | Supply and fixingminiature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP240V, 10 KA \"B\" curve , in the MCB DB Complete with connection testing and commissioning and including taking down complete all as specified and as directed. |
| 128 | Supply and fixingminiature circuit breaker (MCB) of SPN and current carrying capacity 40 Amps 240V, 10 KA \"C\" curve , in the MCB DB Complete with connection testing and commissioningand including taking down complete all as specified and as directed. |
| 129 | S & F steetlight bracket made out of 40 mm dia light grade GI pipe 1.5 Mtr long bend to shape including necessary fixing arrangement with clamp of suitable size made out of 35x 4 mm MS flat suitable shape to pole/builing including nut bolt 03 nos and washer complete all as specified and as directed. |
| 130 | Supply and fixing MCCB 100 Amps, TPN, Breaking capacity 16 KA, 415 V \"C\" curve adjustable type complete all as specified and as directed. |
| 131 | Supply and fixing MCCB 125 Amps, TPN, Breaking capacity 16 KA, 415 V \"C\" curve adjustable type all as specified of capacity complete all as specified and as directed. |
| 132 | M&L for submain wiring withsheathed multi-stranded FRLS Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core HR Grade and one runs of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete complete all as specified and as directed. Note :- 1.Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. |
| 133 | M&L for submain wiring withsheathed multi-stranded FRLS Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core HR Grade and one runs of 6 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed. Note :- 1.Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. |
| 134 | M & L for earthing complete in repairs with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers includingPCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire size of 4.0 mm and length for continuity earth wire from test point to main distribution Board complete all as specified and as directed. (Note:(i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge. ) |
| 135 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 Volts grade aluminum conductor of size 3.5 core 70 sqmm complete all as specified and as directed. |
| 136 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 Volts grade aluminum conductor of size 3.5 core 50 sqmm complete all as specified and as directed. |
| 137 | M & L for earthing complete in repairs with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 25 X 4 galvansihed iron strip earth lead wire by means of nuts bolts check nuts and GI washers includingPCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, iron strip and length for continuity earth wire from test point to main distribution Board complete all as specified and as directed. (Note:(i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge. ) |
| 138 | Supply, installing and commissioning CPRI approved, outdoor cubical fideer pillar box/LT panel suitable for 3 phase 4 wire 415 volts50 hz supply system and size not less than 1.5x1.3x0.5 mtr powder coating provided with suitable to make it dust/vermin proof. The panel shall be made with 3 mm thick CRCA sheet for outer shell and inner shell made out of 2 mm thick crca sheet , double door front and back openable with locking arrangement, provision of threadede earthing stud at bottom, inner shell be compartmentalized, front openable single door system lockable . Inner shell completely vermin proof and to accommodate incoming /outgoing MCCBs,MCBs and TPN aluminium bus and etension links.Aluminium bus bar of capaity 500 Amps -4 Nos including neutral duly insulated with colour coaded heat shrinkable sleeves and shall be mounted on suitable size/rating of epoxy resin insulator all housed in suitable bus bar chamber all control wires shall be with 2.5 Sqmm multi stranded copper conductor and shall be properly bunched, tied ferrulled for proper indentification and crimped with adequte size of lugs and provision and fixing of voltmeter, ammeter, with built in selector switch,CTs of suitable ratio, and pilot indication lamps complete along with provision of necessary cable entry/exit boxes for all incoming and outgoing cables with suitable size of cable glands etc. The panel shall be mounted on 50x50x6mm angle iron stand of height45 cm above ground and 45 cm embeded in ground on suitable PCC foundation. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone and skull be provided complete all as specified and as directed and The panel shall consist of following accessories:- |
| 139 | Incoming |
| 140 | (i)MCCBfour pole 100 Amp ,Ics=100 % Icu, 415V, 50Hz with breaking capacity 35KA,adjustable type - 01 No. |
| 141 | Outgoing |
| 142 | (i)MCCB ,4pole ,32 Amp adjustable Type, ,Ics=100 % Icu,415V, 50Hz with breaking capacity 25KA,- 05 Nos. |
| 143 | (v) MCCB ,TP of capacity 32 Amp,adjustable Type,25KA - 01 No( stand by) . |
| 144 | (vi)Voltmeter 0-500 Volt, with selector switch ,440v -01 No. |
| 145 | ( vii) Ammeter 0- 100 amp, with selector switch and suitable CTs. |
| 146 | (viii)Phase indicator LED based lamp in R,Y,B colours-01 No. |
| 147 | Excavation in trenches n.exc 1.50 m wide and not exc 1.5 m depth for foundation etc or for lying cable etc n exc 10 sqm on plan nd n 1.5 m depth nd getting out in spft/loose soil complete all as specified and as directed. |
| 148 | Returing, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soil complete all as specified and as directed. |
| 149 | Removing excavated materials not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 150 | M& L for dry river sand in trenches including spreading for cushioning of LT UG Cable complete all as specified and as directed. |
| 151 | M & L for sub class \"B\" bricks old size laid flat dry in trenches over cable,across the direction of cable complete all as specified and as directed. |
| 152 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail