| 1 | (B/R PORTION)Taking down cement plaster in any descriptionon brick or stone wall etc incl racking outjoints. hacking for key scrubbing down with water etc complete all as specified and as directed. |
| 2 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for all as specified and directed. |
| 3 | Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillars etc all as specified and directed. |
| 4 | M & L for brick work using old size sub class \"B\" bricks straight or curved on plan exec 6 metre mean radius, built in cement mortar 1:6 all as specified and directed. |
| 5 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair face of brick work or concrete surface in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even. complete all as specified and directed. ( Note -W.P.C. shall be measured and paid separately.) |
| 6 | Supply only integral water proofing compound all as specified and as directed. |
| 7 | M & L for Waterproof (elastic and breathable) film coating in two layer( as per manufacturer instruction) ,patch repair of Damp & repaired walls or old treatment completely removed walls orover old or new plastered surfaces of walls including preparations of wall complete all as directed. |
| 8 | M&L for applying2mm thick wall care putty (in two layers) on old cleaned surfaces of walls, soffits of chajja, roof slab etc, for smooth finish and finishing with two coats of weather proof exterior emulsion paint over a coat of suitable exterior primer of approved make using airless spray technology capable of operating single spray gun with hose of adequate length for upto 4 storey building height including necessary scaffolding, safety and protective measures complete all as specified and directed. |
| 9 | M&L for 10 mm thick rendering in cement mortar (1:3)to fair faces of brick or concrete ceiling surfaces finished even & smooth without using extra cement all as specified and directed. |
| 10 | M&Lforapplying two coats of oil bound distemper on new surfaces of ceiling including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) over a coat of alkali resistant primer applied over 3mm thick BIRLA/JK water proof wall care putty complete all as directed by Engr-in-charge. Complete all as specified and directed. |
| 11 | M&L for 15mm thick rendering in cement mortar (1:6) to fair faces of brick or concrete wall surfaces finished even & smooth without using extra cement all as specified and directed. |
| 12 | M&Lforapplying two coats of oil bound distemper on new surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) over a coat of alkali resistant primer applied over 3mm thick BIRLA/JK water proof wall care putty complete all as directed by Engr-in-charge. Complete all as specified and directed. |
| 13 | M&L for complete removal of existing treatment of old wall surface and applying two coats of oil bound distemper over a coat of alkali resistant primer applied over 3 mm thick BIRLA/JK water proof wall care putty complete all as specified and directed. |
| 14 | M&Lforapplying two coats of oil bound distemper to old decorated (distempered/damp proof painted) surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed. |
| 15 | M&Lforapplying two coats of oil bound distemper to old decorated (distempered/damp proof painted) surfaces of ceiling including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed. |
| 16 | Removal of existing water proof treatment of any description including cement plaster carefully from the surfaces cleaning and scrubbing down with water complete all as specified and as directed. |
| 17 | M & L for water proofing treatment on existing cleaned RCC roof with following specification and manufacturer Instruction complete all as specified as directed.(a) Applying bitumen primer confirming to IS-3384-1986 over the cleaned plaster surfaces as per IS-3067-1966.(b) Applying a layer of APP based polymeric membrane 3.0mm thick (minimum) weighing 3.0 Kilogram per sqm (reinforced with polyster non oven fabric weighing not less than 160 Gmss per sqm by torch application. The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction.(c) applying one coat of aluminium paint @ 0.10 Litre per Sqm Over APP based Polymeric membrane. |
| 18 | M & L for Providing, cement concrete, Type B1, 1:2:4 ( 20mm aggregate) in roof kerbs or mud stops, padding, rounded or chamfered on edges on existing roof( with proper slope) including preparing of roof slab complete all as directed. |
| 19 | M&L rendering 10 mm thick screed bed on concrete surface in CM (1:4) & water proofing compound mixed with @ 3% finished fair and even. ( Note -W.P.C. shall be measured and paid separately.) |
| 20 | M&LFor Up rooting of tree from walls of bldgs up to extended root and spraying of acid of required quantity complete from any location of bldg, up to onestorey and making good disturbed surface with cement mortar (1:4) or cement concrete type C1 (1:3:6) using 20 mm graded stone aggregate etc complete all as specified and directed. |
| 21 | M & L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. |
| 22 | Taking down chowkats or frames with shutters (w/o taking off shutters from the frames) area not exceeding 1.5 sqm each and removing from the site complete all as directed. |
| 23 | Taking down chowkats or frames with shutters (w/o taking off shutters from the frames) area exceeding 1.5 sqm and not exceeding 4 sqm eachand removing from the site complete all as directed. |
| 24 | Taking down shutters of any description area not exceeding 1.00 sqm each and removing from the site complete all as directed. |
| 25 | Taking down shutters of any description area exceeding 1.00 sqm and not exceeding 2.00 sqm each and removing from the site complete all as directed. |
| 26 | S&F Cast iron work grade FG 150, machined orunmachined, in brackets, gully traps, ratings, spiral stair case steps, treads and risers, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles complete all as specified and directed. |
| 27 | Dismantling unframed timber scantling 40 Sqcm and over in section, in any position all as specified and directed. |
| 28 | Supply and fixing 1st class hard woodplain solid straight chowkats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints all as specified and as directed. |
| 29 | supply & fixing 40 mm thick 1 stclass hard wood panelled shutters (any Nos of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density wood particle board with commercial face veneers, fitted to chowkats complete all as specified and as directed. |
| 30 | Supply and fixing 35 mm thick 1st class hard woodGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed. |
| 31 | S&F 40 mm thick Ist class hard wood Framed louvered shutters with stiles and rails 100 to 120 mm wide and panels filled with fixed louvers from 10 to 15 mm thick, supplied and fitted to frames all as specified in SSR Part-I, Section 8.24(b) complete all as specified and as directed. |
| 32 | S& F 30mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 33 | S&F instainless steel wire cloth of 0.36mmnominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples as directed. |
| 34 | M&Lforpreparation ofnew untreated wooden surfaces of any description, not otherwise describedover 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 35 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, steel window or stone concrete or brick surrounds glazed with putty or fixed with beads complete all as specified and directed . |
| 36 | S&F 3mm thick plain sheet glass ordinary quality and glazing with oil putty in square n.exc 0.50 Sqm in each pane complete all as specified and directed. |
| 37 | S&F 4.8mm thick plain sheet glass ordinary quality and glazing with oil putty in square n.exc 0.50 Sqm in each pane complete all as specified and directed . |
| 38 | S & F in repairs 450 mm long brass steel skeleton tower bolts with cast brass plate and staples and rolled or dwawn brass bolt complete all as specified and as directed. |
| 39 | S & F in repairs 600 mm long brass steel skeleton tower bolts with cast brass plate and staples and rolled or dwawn brass bolt complete all as specified and as directed. |
| 40 | S & F in repairs 300 mm long brass , sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and filing bolt with rolled or drawn brass bolts complete all as specified and as directed. |
| 41 | S&F Floor door stopper of brass body and tongue, anodised with hard drawn steel spring over all length of cover plate 140mm fixed in flooras in repair complete all as specified and as directed. |
| 42 | S&F cast type ,polished bright brass handles 150mm long complete all as directed. |
| 43 | Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as directed. |
| 44 | Supply and fix non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and incl 15 mm thick screed bed in 1:6 complete all as directed. |
| 45 | Material and labour for 300mm x 450mm x 7mm thickdecorative type wall tiles (coloured) joint free as in vertical surfaces of and jointed with neat cement slurry and pointed in white/coloured cement to match the surface laid over and including 10mm thick rendering in CM(1:3) complete all as specified and as directed. |
| 46 | Supply and fix vitrified tiles(dark shade) of 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm as in floor set and jointed in neat cement slurry @ 3 kg per Sqm and pointed in coloured cement to match the shade of the tiles over and incl. 20mm screed bed in CM (1:6) complete all as directed. |
| 47 | Supply and fix vitrified tiles ( dark shade) of 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm as in skirting set and jointed in neat cement slurry and pointed in coloured cement to match the shade of the tiles over and incl. 10mm rendering in CM (1:3) complete all as directed. |
| 48 | M&L pre polishedChequered cement concrete 25mm thick& area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors set , jointed & pointed with neat cement slurrywith grey cement and pigment including15 mm thick screed bedor bedding layer incementmortar (1:6)overbrushing with neat cement slurry with 3.00 Kg of cement per sqm completed all as specified and directed. |
| 49 | Dismantling structural steel work of any description including doors, gates, railing etc but excluding framed trusses all as directed. |
| 50 | Supply and fixing for structural steel work Fe 410-W (Gde-E-250) rolled mild steel in joist, channel, angle or Tee section fixed independently etc up to height 4 to 6 mtr from each floor level (cut to ordinary length ie. Within 20mm of the length indicate) Gde Fe-410-W-(Gde-E-250) Quality-B including using former iron props and steel plates to existing RCC over head members like beams, slabs etc so as to ensure safety of existing structure and floor during repairing works complete all as directed by Engr-in-Charge. Note: The section to be provided under this item will be used as beam to support floor/roof. (Note : the item execute.) |
| 51 | M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paintover a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 52 | M&Lforapplying one coat of synthetic enamel paint to old painted steel surfaces of any description and in any position over 10 cm width or girth including preparation of surfaces all as specified and directed. |
| 53 | M&Lforapplying one coat of synthetic enamel paint to old painted wooden surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed. |
| 54 | S & F mild steel in framed work such as grills, gratings, etc. with ends of bars shouldered and /or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed. |
| 55 | Dismantling of plain or corrugated steel sheeting any gauge or any thickness in roof covering including stacking serviceable materials of re-use and removing unserviceable materials complete all as specified and as directed. |
| 56 | S & F pre-painted color galvalume aluminium zinc coating GI based corrugated steel 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 57 | S & Fpre-painted color galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridges , valley gutter etcfixed with self tapping screws complete all as specified and as directed. |
| 58 | S&F0.56 mm thick plain aluminium sheeting alloy 31000 H4 as in ridges, hips, valley gutter, drip and straight flashingetc complete all as specified and as directed. |
| 59 | S & F in repair 15mm bore galvanised steel tubing (medium grade) with all fittings and fixed to walls and ceiling or laid in floors complete all as directed. |
| 60 | S & F in repair 20mm bore galvanised steel tubing (medium grade) with all fittings and fixed to walls and ceiling or laid in floors complete all as directed. |
| 61 | S&F in repair vitreous china squatting pan Orissa pattern wash down water closetwhite of size 630x450 mm, with integral foot rests complete with P or S trap includingwith 10 ltr capacity PVC flushing cistern with flush pipe, PVC connection 450mm long etc. complete all as specified and directed. |
| 62 | Supply and fix in repairs Low density polyethylene pipe connection, comprising of 15 mm dia 450 mm long having PTMT union at each end of connection to each of pillar tap/cistern/stop cock/urinal etc. at one end, stop cock at other end complete all as specified and directed.(MAKE : PRAYAG, Cat No. 323 / POLYTUF, Cat No. 4003 or equivalent makespecified in tender. |
| 63 | Supply and fix in repairs Low density polyethylene pipe connection, comprising of 15 mm dia 600 mm long having PTMT union at each end of connection to each of pillar tap/cistern/stop cock/urinal etc. at one end, stop cock at other end complete all as specified and directed.(MAKE : PRAYAG, Cat No. 323 / POLYTUF, Cat No. 4003 or equivalent makespecified in tender. |
| 64 | S&F in repair White PVC Flushing Cistern 10 Litre capacity, Low Level Valve Less, Symphonic Action type with Inlet, Ball Valve, Float, flush pipe and Handleincluding Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 and fixed including taking down/out unserviceable Flushing Cistern and connected items complete all as specified and directed.(MAKE : PARRYWARE, Model : Slim line Economy / HINDWARE, Model : Sleek Plus / CERA, Model : Corona / PRAYAG, Model: SMART or equivalent makespecified in tender. |
| 65 | S&FChromium Plated 25mm dia brass chromium plated curtain rod withfixing brackets, stops, rollers etcasdirected. |
| 66 | S&F fancy type metal finish curtain bracket fixed to walls complete all as specified and directed. |
| 67 | Supply and fix, as in repair, 15 mm bore bib taps, fancy type, chromium plated long neckcast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified. |
| 68 | S&Fin repair Chromium plated brassAngular stop cock, fancy type,concealed type with wall flange fixed to 15 mm bore of Iron pipe complete all as specified and directed.(Make : JAQUAR, Cat No: CON-59KN / PARRYWARE, Cat No: G1453A1 / ESS ESS, Cat No: C-206 / CERA, Model: OCEAN / PRAYAG, Cat No: 9210 / HINDWARE, Cat No: F330043) or equivalent makespecified in tender. |
| 69 | M&L 75 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in plinth protection/Paving etc, finished even and smooth without using extra cement as directed. |
| 70 | S&F in repairs stainless steel round grating 150mm dia complete all as specified and directed. |
| 71 | M&L for one coat ofFrench polishing on old surfaces of any description, width or girth including cleaning and preparing the surface complete all as specified and directed. |
| 72 | Dismantling ofStone slabs and tiles of anydescription or thickness in floors, aprons, vertical surfaces etc. and,laid and pointed in any mortar complete all as specified and directed. |
| 73 | S&F20 mm thick granite slab cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pavement to match the shade of granite stone incl grinding and polishing overand including 20mm screed bed in CM(1:6) completed all as directed. |
| 74 | S&F20 mm thick granite slab as in vertical surfaces cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pavement to match the shade of granite stone incl grinding and polishing overand including 10mm rendering in CM(1:3) completed all as directed. |
| 75 | M&L for two coats ofVarnishing (under coating and finishing coat) with synthetic varnish over a filler coat with transferant wood filler liquid on old surfaces of wood or wood based surfaces of any description, any width or girth including cleaning and preparing the surface including sizing complete all as specified and directed. |
| 76 | M&L 50mm thick sand stone slabs; set and jointed in cement mortar 1:4 over joists in roofs, etc., incl formwork complete all as specified and directed. |
| 77 | (E/M Portion)Materials and Labour for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.((a) One light/fan/bell point controlled by one switch. |
| 78 | All as item No 77 above here in before but one3/5 pin5 Amp socket outlet point controlled by one switch on same board. |
| 79 | All as item No 77 above here in before but one 3/5 pin5 Amp socket outlet point controlled by one switch on independent board. |
| 80 | All as per item No 77 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke ( FRLSH ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 2.5 sqmm green copper conductor as continuous earth wire with lugs complete all as specified and directed. |
| 81 | Supply & fixingwall mountedfans 230 volts singlephaseoscillating 400 mm sweep with white/black color with following technical specification Box Dimension 48x24.5x47.5cm wattage 35W ,Air Delivery (CMM)76 Blade Length 40CM,Speed 1500RPM, Item Weight 4.2Kg Voltage 165-285V, Blade Material ABS Plastic including all fixing accessories for fixing at Wall complete all as specified and directed. |
| 82 | S&F Ceiling rosethree terminals polycarbonate , isolated body completeall as specified and directed. |
| 83 | M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and including PVC casing-capping of suitable size, surface type all as directed. |
| 84 | S & F Switch socket combination with back cover 2 in 1, 5 Amp flush type complete all as specified and directed. |
| 85 | Supply and fixing PVC casing/capping of size 25 mm with all accessories all as directed. |
| 86 | Supply and fixing PVC casing/capping of size 20 mm with all accessories all as directed. |
| 87 | S & F Sheet metal enclosure for MCB DB double door 415V Triple pole & Neutral 4 way with common bus bar. complete all as specified and directed. |
| 88 | S & F MCB four pole , 63 Amps with breaking capacity 10kA,complete all as specified and directed. |
| 89 | Taking down carefullyexisting aluminium/copper point wiring on battenor in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power ) complete and making goodthe disturbedsurfaces of walls, Floors, ceilings etc to match with existingall as specified and directed. |
| 90 | S & F Modular Switch 1 way 6 A, 1 module complete all as specified and directed . |
| 91 | S & F Modular Blank plate, 1 module complete all as specified and directed . |
| 92 | S & F Modular type White cover plate with frame 3 module complete all as specified and directed . |
| 93 | S & F Modular type Metal Flush box 3 module complete all as specified and directed . |
| 94 | S & F Modular Switch 1 way 16 A, 1 module complete all as specified and directed . |
| 95 | S & F Modular Socket 6 A- 2/3 pin combined 2 module complete all as specified and directed |
| 96 | S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed |
| 97 | S & F Modular type White cover plate with frame 4 module complete all as specified and directed |
| 98 | S & F Modular type White cover plate with frame 6 module complete all as specified and directed |
| 99 | S & F Modular type Metal Flush box 4 module complete all as specified and directed. |
| 100 | S & F Modular type Metal Flush box 6 module complete all as specified and directed. |
| 101 | Supply and Fixing led strip light fitting 230 Volt 24 W 3K warm Wight coloring and water proofing complete all as specified and as directed. |
| 102 | Supply and fixing led strip light for Driver 230 Volt 24 W 3K complete all as specified and as directed. |
| 103 | S & F LED down hanging lightfitting 9 W, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cableE-27 LED 9w X1 complete all as specified and directed. Make: Jaquar JFO-COP-SLPEA089AE27or equivalent make in specified in tender. |
| 104 | S & F LED decorative wall light 2X10W complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. Make: Crompton LUPDN-10-WWor equivalent make in specified in tender. |
| 105 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 106 | Supply and fix vento jet horizontal Auto Exhaust fanAC single Phase 230 V / 240V 50 Hz of size 150 mm Sweep brushed steel finish / Off White, Automatic front shutter High suction capacity, silent operation, wall, ceiling and glass mounting, Removable & Screw less front for easy cleaning and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. complete all as specified and directed. |
| 107 | S & Fceiling fans complete with all accessories 230 volt single phase 1200mm sweep with down rod any size , canopy, fan blades and accessories, BEE 5 Star Rated and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 sqmm , 3 core, 1100 Volts grade, from ceiling rose / connector to fan complete all as specified and directed. |
| 108 | Taking down of old Submain wiring upto 10 sqmm any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed. |
| 109 | Taking down of Old MCB DB any type any size including MCBs etc complete all as specified and directed. |
| 110 | S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with 200 amps rated bus bar complete all as specified and directed. |
| 111 | S & F MCB \"C\" curve single pole neutral , 32 Amps with breaking capacity 10kA, complete all as specified and directed. |
| 112 | S & F MCB \"C\" series single pole 6 to 32 Amps, breaking capacity 10KA. complete all as specified and directed. |
| 113 | S & F in repair AC short circuit protection motor starter 20 Amps capacity AC 230 Volt complete all as specified and directed. |
| 114 | Note: Schedule of credit (SCHEDULE OF CREDIT)amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ. |