| 1 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. |
| 2 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows ,railing etc. fitted and fixed with necessary screws and lugs in ground floor. |
| 3 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary.[Excluding cost of chipping over concrete surface] |
| 4 | 1ST floor |
| 5 | Stripping off worn out plaster and raking outjoints of walls, celings etc. upto any height and inany floor including removing rubbish within alead of 75m as directed. |
| 6 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame |
| 7 | Z-batten shutters of door and window as per design havingstongued and groove-half lap jointed as per direction of theEngineer-in-Charge including fitting and fixing shutter inposition, but excluding the cost of hinges and other fittings inground floor.Shutter with 25mm thick planks, 19mm thick battens.Sishu, Gamar, Champ, Badam, Bhola, Morga, Hallak. |
| 8 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface.Two Coats |
| 9 | Removing old scales, blisters etc. of interior surface of walls,ceiling byscraping etc. and preparing smooth and even surface with rendering orcement mortar (1:2) (as necessary), to make the surface suitable forreceiving distemper. (Payment against this item will be made only whenthis has been done on the specific direction of the Engineer-in-charge) |
| 10 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer |
| 11 | 1st floor |
| 12 | Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) |
| 13 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 14 | On metal surface |
| 15 | Painting with best quality synthetic enamel paint of approved makeand brand including smoothening surface by sand papering etc.including using of approved putty etc. on the surface, if necessary : |
| 16 | (a) On metal surface :With super gloss (hi-gloss) - (except white in shade) |
| 17 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)(b) 40mm X 6mm, 250mm Length |
| 18 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.100mm. X 50mm. X 1.25mm. |
| 19 | Iron socket bolt of approved quality fitted and fixed complete.150mm long x 10 mm dia bolt |
| 20 | 225mm long x 10 mm dia bolt |
| 21 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: |
| 22 | Providing and fixing of false ceiling with powder coated exposed G.I. gridsuspension system (E-Grid T 2430/1510 or equivalent load carrying capacity withmid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm longand Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on theperimeter of the wall by steel screws with distance 300mm c/c. The Main Runnersto be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cutslots of Main Runner at a regular interval of 600 mm to form a modular grid of1200mm X 600mm. Additional Cross Tees of 600 mm shall be placedperpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm diaG.I. wire from purlins / soffit. 4 mm thick High Pressure Steam Cured NonAsbestos pearl designer Fibre Cement Standard Ceiling Board (Density > 1500Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type A Category IV ofISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should beplaced in the Grid module to form a False Ceiling. All complete as per thedrawing & directions of Engineer-in-charge.In ground floor.a) False Ceiling (with 4mm thick Pearl Designer Fibre Cement Board and E-GridT-2430/1510). |
| 23 | Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels as directedwith topping made with ordinary or white cement (asnecessary) and marble dust in proportion (1:2) includingsmooth finishing and rounding off corners including rakingout joints or roughening of concrete surface and applicationof cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor.3 mm. thick topping (High polishing grinding on this item isnot permitted with ordinary cement).Using grey cement35mm thick |
| 24 | Clearing compound premises of shurbs, plants, junglesetc. by cutting and removing as directed (Specificpermission of Engineer-in-Charge prior to executionwill be necessary).(Payment to be made on area cleared) |
| 25 | Supplying and fixing Sheet steel Main Switches on angle iron frame on wall 63 A 415 Volt TPN with fuse on L & N( make- Havells ) |
| 26 | Supplying and fixing double-door SPN MCB Distributiobn board with IP-42/43 protection concealed in wall after cutting the wall & mending good the damages to original finish incl. interconnection with suitable size of copper wire and neutral link & provision for earthing attachment.Legrand/Siemens/ABB2+8 way Enclosure |
| 27 | Supply and fixing 240V/415V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.Legrand/Siemens/ABBi) 6-32A SP |
| 28 | Wiring in 1.1 KV grade single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc2 X 22/0.3 (1.5 sq.mm) |
| 29 | 2 X 36/0.3 (2.5 sq.mm) + 1 X 22/0.3 (1.5 squmm) as ECC |
| 30 | 2 X 56/0.3 (4 sq.mm) + 1 X 22/0.3 (1.5 squmm) as ECC |
| 31 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish [PVC casingcapping on surface and Switch board concealed2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCAverage run 8 mtr |
| 32 | Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping on surface and Switch board concealed]2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCOn Board |
| 33 | Supplying & fixing 240V 16A 3 pin Moduler type plug socket (Make- Legrand/North West/ABB) with 16A Moduler type switch, without plug top on GI Moduler type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necessary connection with PVC Cu wire and earth continuity wire etc. |
| 34 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length |
| 35 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30cm incl. painting the rod with approved paint and making necessary connection as required by (ii) 2x1.5 sq.mm. flexible copper wire |
| 36 | S&F 240V Moduler socket (2 module) type fan regulator (step type (Make-Legrand/NorthWest/ABB) on existing Moduler GI switch board with top coverplate incl. making necy. connections etc. |
| 37 | Supply of Ceiling fan (48\") 1200 mm with double ball bearing, capacitor start, complete with down rod, canopy, fork etc. without regulator. Colour- White/Brown. (Make-USHA, Model- New Prima/ Orient PSPO) |
| 38 | Supply tmc501 conventional industrial batten philips led tube model no- TMC501P1 x T-LED 22WP3241 ) complete with LED Lamp (MAS LEDtube1200mm18W865T81) |