Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-10-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-10-2024 |
| 2 | 09-10-2024 | Other Corrigendum | Other | 15-10-2024 |
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in Soft / Loose soil complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. |
| 3 | Removal of excavated material [Soil] to a distance not exceeding 5 Km and depositing where directed complete all as specified and as directed. |
| 4 | M & L for Dry river sand cushioning over and around the cable for cable protection in trenches, leveled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment. |
| 5 | Supplying and laying un–reinforced Precast Concrete Cable Cover, Class LV, Type 1, Flat, of size 250mm x 150mm x 40mm complete all as specified and as directed. |
| 6 | Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance exceeding 1.50 KM but not exceeding 5.0 KMcomplete all as specified and as directed. |
| 7 | Demolition of Stone Slab laid, bedded and pointed in Cement Mortar of thickness not exceeding 25 mm and removing serviceable tiles to the stores andremoving rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed. |
| 8 | M & L for 25 mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded aggregate as in Sub base for flooring complete all as specified and as directed. |
| 9 | M & L for Vitrified Tiles, Double Charged, Coloured, Premium Quality, of size not exceeding 0.36 Sq.m, 8 to 9 mm thick as in Floors, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. |
| 10 | M & L for Vitrified Tiles, Light Shade,, Coloured, Premium Quality, of size not exceeding 0.36 Sq.m, 8 to 9 mm thick as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. |
| 11 | M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. |
| 12 | Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores andremoving rubbish / debris to a distanceexceeding 1.50 KM but not exceeding 5.0 KM complete all as specified and as directed. |
| 13 | M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm or 350 mm x 250 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. |
| 14 | M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Floors, Treads of Steps, Window Cills, Cooking Platform etc., and the like with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed andpointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabsincluding screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4complete all as specified and as directed.Note: Single stone slab shall be used for entire Width and Length of Steps, Window Cills, Cooking Platform etc. and joints shall match with the flooring. The edges of treads shall be bull nosed / half rounded. The edges of the treads and landings shall also be provided with three Nos of grooves. |
| 15 | M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Skirting, Dado, Risers of Steps, Jambs, Pillars, Wall Lining [Veneering to Wall] etc. with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including diagonals, inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed andpointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs over backing coat of 10mm thick in Cement Mortar 1:3complete all as specified and as directed. Note: Single stone slab shall be used for entire height of Skirting / Dado / Risers and joints shall match with the flooring. |
| 16 | S & F Aluminium Composite Panel sheet of 3 mm thickwith skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30 micron, fixed over the existing Frame Work with suitable Self Tapping Screws in approved pattern / size including taking down existing unserviceable boards/ sheets of any description and size complete all as specified and as directed. Make: ALSTRONG / ALCOBOND / ALSTONENote: Frame work shall be measured and paid separately under relevant item of this BoQ. |
| 17 | Dismantling of Plain or Corrugated Steel sheeting of any gauge, thickness of roof in roof coverings, complete all as specified and as directed. |
| 18 | S & F pre-painted Galvalume steel sheets of Trapezoidal profile having pitch 190mm, depth 29mm or Tiled Profile and thickness 0.50mm [Galvalume base-PPGL trapezoidal profile sheets], having tensile strength of 550 Mpa, fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size in roof covering complete all as specified and as directed. Note: Overlap shall be provided as specified by the manufacturer. |
| 19 | S & F pre-painted Galvalume steel Plain Sheets and thickness 0.50mm [Galvalume base-PPGL Sheets], having tensile strength of 550 Mpa, in ridges, hips, valley gutters, drip and straight flashing cut to length & bent to shape, girth sheets fixed with aluminium self tapping screws and neoprene and EPDM washers of suitable size in roof covering / cladding / eves trim / rake trim and closure trim / valley rain water gutter/ down spouts and top rafters etc. complete all as specified. |
| 20 | S & F in repairs Mild Steel work conforming to Fe - 290, Grade E-165 as in Hand Rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for Balusters Running Bars, for Doors, Balusters, Nosing to Steps including embedding in concrete and screwing etc., Wind Ties for roof including securing bolts, Posts and Struts in Fencing including cutting tops to shape as directed, bendingto shape, notching for wire, drilling holes or as in flat iron fillets [forsecuring wire mesh and barbed wire etc.] including all necessary drilling, bolting or riveting, etc. and similar work complete all as specified and directed. |
| 21 | Taking down Eaves Gutters /SWR Pipes [any size or pattern], including all fittings, heads, shoes, bends, swan-necks, etc. from any height complete all as specified and as directed. |
| 22 | S & F110mm bore UPVC [SWR] pipes single socketed, in any length with rubber ring/ solvent cement joints, fixed to walls in any position with necessary brackets, clamps, bolts, nuts, etc.,complete all as specified and as directed. |
| 23 | S & F75mm bore UPVC [SWR] pipes single socketed, in any length with rubber ring/ solvent cement joints, laid in trenches or in floors complete all as specified and as directed. |
| 24 | S & F 110 mm bore UPVC [SWR] bends, any radius including jointing with solvent cement complete all as specified and as directed. |
| 25 | S & F 75 mm bore UPVC [SWR] bends, any radius including jointing with solvent cement complete all as specified and as directed. |
| 26 | S & F 110 mm bore PVC [SWR] Branch Piece, double [Double\"Y\"] equal or unequal including jointing with solvent cement complete all as specified and as directed. |
| 27 | S & F 75mm outlet PVC [SWR] Floor Trap with grating including jointing with solvent cement complete all as specified and as directed. |
| 28 | S & F CPVC Pipes 20 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testingincluding taking down of existing unserviceable GI pipes and connections of any description complete all as specified and as directed. |
| 29 | S & F CPVC Pipes 25 mm outer diameter & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testingincluding taking down of existing unserviceable GI pipes and connections of any description complete all as specified and as directed. |
| 30 | S & F CPVC Pipes 40 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testingincluding taking down of existing unserviceable GI pipes and connections of any description complete all as specified and as directed. |
| 31 | S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 Mpa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed. |
| 32 | S & F in repairs Bib Taps, 15 mm dia, Brass Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed. |
| 33 | S & F in repairs Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts screwed for iron pipe and fixed completeall as specified. |
| 34 | S & F in repairsStop Valves/Angle Cocks, 15 mm bore dia of pipe, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions etc complete all as specified and as directed. |
| 35 | S & F in repairs Vitreous China Full stall urinal complete including providing waste pipe and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with bracket complete all as specified and as directed. |
| 36 | S & F in repairs Vitreous China Wash Down Water Closet [Pedestal pattern], White, including 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern (dual flush), white, with inlet ball valve, float, handle, flush pipe of polyethylene of lowor high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMTcheck nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and \"P\" or \"S\" trap complete all as specified and as directed. |
| 37 | S & F in repairs Decorative type Stainless Steel Decorative type Bracket and finial of size suitable to 25mm dia curtain rod fixed to wall with SS screws complete all as specified and as directed. |
| 38 | S & F in repairs Health Faucet, ABS body, including 1.25 m long flexible tube, ABS wall hook, non return valve complete all as specified. |
| 39 | S & F in repairs Two way Bib tap, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. LYR 38041 or its equivalent inKohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified. |
| 40 | S & in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible waste pipe, PVC Connection of PTMT complete all as specified and as directed. |
| 41 | S & F in repairs Mirror of selected quality Belgium glass, 6 mm thick, mounted on stainlesssteel studs of suitable size fixed to wall complete all as specified and as directed. |
| 42 | S & F in repairs 100mm size Stainless Steel grating for Floor Traps complete all as specified and as directed. |
| 43 | S & F in repairs Stainless steel kitchen sink with drainage board, made of stainless steel sheet of 1 mm thick, with plugs, washers, Waste Fittings, 32 mm dia, Brass, Chromium plated,and 32mm dia PVC flexible Waste Pipe, 750 mm long, including bedding in Cement Mortar to dwarf wall or including fixing cantilever CI Brackets and connecting union to waste pipe, over all size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and as directed. |
| 44 | Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.meach complete all as specified and as directed. |
| 45 | Taking down Chowkats or frame with shuttersexceeding 1.5 Sq.m but not exceeding 4.00 Sq.m eachcomplete all as specified and as directed. |
| 46 | S & F factory made single rebated Wood Polymer Composite [WPC] solid door/ window Frames/ Chowkhats of size 65mm x 125mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms), fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with properties of termite / borer proof, water/ moisture proof and fire retardant, fixed in position complete all as specied and as directed. Note: The hold fasts/ lugs/ fasteners shall be measured and paid separately under relevant items of this Schedule/ BoQ |
| 47 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: Stainless steel butt hinges and necessary S S screws shall be paid separately |
| 48 | S & F Factory made UPVC Fixed Window / Ventilator, White Colour,made of extruded profiles with wall thickness of 2.3mm±0.2mm, Window profile with hollow section with multi chamber, Frame of size 60mm X 58mm, T Profile [One vertical length in between two shutters] of size 60mmx 74mm, Glazing Bead of size 35mm X 20mm will be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM Gasket, 1.2mm±0.2mm thick Galvanized Steel Frame of size 28mmx 21.5mm, T Profile of size 27mm x 17mm to be inserted in required profile, frame shall be fixed to wall with 8mm X 100mm long fasteners, 5mm thick glazing with selected quality glass complete all as specified and as per Manufacturer instructions. (a) The size of UPVC sections specified in the description of item is minimum requirement. If the same size of section is not available, next higher size shall be provided by the contractor without any extra cost to the Department. However the acceptable tolerance limit for lesser size shall be upto minus 5%. (b)Supply only of Glass shall be measured and paid separately under relevant Items of Schedule \"A\" / BoQ. The unit rate quoted by contractor shall include all other connected accessories for glazing. (c) Net opening shall be measured for payment purpose. |
| 49 | S & F Factory made UPVC Sliding Window, Three Track, White Colour of area not exceeding 2.0 Sq.m, made of extruded profiles with wall thickness of 2.3mm±0.2mm, Window profile with hollow section with multi chamber, Frame of size 88mm X 52mm, Sliding Sash of size 42mm X 67mm, Sliding Mesh Sash of size 42mm X 57mm, Sliding Interlock [One vertical length in each shutter] of size 45.50mm X 28mm, Glazing Bead of size 24.50mm X 16mm shall be mitred cut and fusion welded at all corners, including drilling holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM Gasket, 1.2mm±0.2mm thick Galvanized Steel Frame of size 30mmx 18mm, 2 Nos, Sliding Sash of size 30mm x 18mm, Sliding Mesh Sash of size 26mm x 10mm profile to be inserted in required profile, frame shall be fixed to the wall with 8mm X 100mm long fasteners,Hardware such as Touch lock of zinc alloyed [white powder coated], Steel roller system, Stainless Steel Wire Cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories shall be provided with proper operative and locking hardware mechanism, frame shall be fixed to wall with high quality fasteners and silicon glue shall be applied to fill up gap between frame and wall to make leak proof complete all as specified and as per Manufacturer instructions.Note: Notes: (a) Net opening will be measured for payment purpose.(b) Supply only of Wire mesh, deco grills and glass shall be measured and paid separately under relevant Items of Schedule \"A\" / BoQ. The unit rate quoted by contractor shall include all other connected accessories for glazing. (c) The size of UPVC sections specified in the description of item is minimum requirement, if the same size of section is not available, next higher size shall be provided by the contractor without any extra cost to the Department. |
| 50 | Supply only 5mm thick Sheet Glass ordinary quality in squares exceeding 0.5 Sq.m in each pane complete all as specified and as directed. |
| 51 | Providing & fixing12mm thick fully glazed single/ double leaf reamless swing door made for anodized aluminum alloy extrusions fabrication after cutting to proper shape and size, drilling and aligning fitted with heavy dury hydrolic action floor spring with top pin assembly and fitted with inbuilt locking arrangement and all other necessary fittings, fixture, adhesives and joineries, cutting the glass to requisite shape and size mounting the edges for fitting the same with dry set neoprine / EPDM gasket.all complete all as specified and as directed. |
| 52 | Supply onlyStainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm complete all as specified and as directed. |
| 53 | Supply only Powder Coated Aluminium Deco Grill of Model / Design No. DG 104 (7mmx4.2mm), including Powder Coated Aluminium Channel of size 10 X 10 X 1.5mm for fixing Deco Grill complete all as specified and as directed. |
| 54 | S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 55 | S & FAluminium anodised barrel Tower Bolt of size 150 mm size of extruded section complete all as specified and as directed. |
| 56 | S & F 125 mm size, Butt hinges, Extruded Aluminium alloy with galvanised mild steel hinge pin, anodised, Type B-21, including fixtures complete all as specified and as directed. |
| 57 | S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed. |
| 58 | S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed. |
| 59 | S & FFactory made 35mm thick, Second Class Hard Wood, Plain framed, Panelled Shutter [Two Panel] with Lock Rail and Panel of 9 mm BWP Commercial Ply or 12 mm Veneered Particle Board with Commercial Veneering on both faces, the size of Rail and Stile as per IS – 1003 [Part – I], Kiln Seasoned and Chemically Pressure treated and fitted to Chowkats complete all as specified and as directed. |
| 60 | S & FAluminium anodised barrel Tower Bolt of size 150 mm size of extruded section complete all as specified and as directed. |
| 61 | M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed. |
| 62 | Dismantling of Structural Steel work including Doors, Gates etc but excluding framed trusses complete all as specified and as directed. |
| 63 | S & F in repairs Rolled Mild Steel work confirming to Fe 410-W, Grade-E- 250, Quality-A as in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering, Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings [exclusive of steel sheeting or other covering, running rails and guides] and hanging, also fastening and fixing complete all as specified and as directed. |
| 64 | M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed. |
| 65 | Dismantling of Wall & Ceiling Boards [Fibre / Pulp / Insulation etc] of any description or Insulation Boards / Slabs / Blankets including cover fillets complete all as specified and as directed. |
| 66 | S & F False Ceiling Frame Work using Anodised Aluminium snap grid frame work of 600 X 600 mm panel size for false ceiling with Aluminium \"T\" section of size 38 X 25 X 1.50 mm thick for Main Runners, 25 X 25 X 1.5 mm thick for Cross Runners and Angle of size 25 X 25 X 1.50 mm thick along the Walls suspended with and including 4 mm dia, Galvanized mild steel wire as in suspenders of ceiling members fixed in proper position including fixing 16mm thick Mineral Fibre Board of size 600 X 600 X 16mm of make Armstrong [Model No. DUNE RH99 or equivalent approved makes as specified here in after], Premium sand textured finish, having humidity resistance of RH99 for false ceiling, fixed to ceiling section with 25 mm dry wall screws at 230 mm centres and including dismantling of Wall & Ceiling Boards [Fibre / Pulp / Insulation etc] of any description or Insulation Boards / Slabs / Blankets including cover fillets complete all as specified. |
| 67 | M & L for roughening surfaces of old concrete roof by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thickin cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cementincluding mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight notless than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion complete including taking down existing Roof Treatment of any description and removing rubbish to a distance exceeding 10 KM and not exceeding 1.50 KM complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately. |
| 68 | M&L for providing roof cooling ceramic tiles of size 300 x 300 mm, 7 to 8 mm thick, conforming to IS 15622, set and jointed in cement slurry and pointed flush with epoxy mortar to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: [a] The colour/ shade/ design of tiles shall be as approved by GE.[b] The tile joint shall be kept as 3mm using 3mm thick tile spacers and masking tape shall be provided before applying of the epoxy grout and the surplus grout materials shall be thoroughly cleaned immediately. |
| 69 | Supply only integralwater proofing compound [ISI marked] of approved make. |
| 70 | Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance exceeding 10 KM but not exceeding 15 KMcomplete all as specified and as directed. |
| 71 | M & L for 25 mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded aggregate as in Sub base for flooring complete all as specified and as directed. |
| 72 | S & F Floor Door Stopper of size 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed. |
| 73 | S & F Door Closer Hydraulically Regulated, Designation No. 3 universal type, suitable for door shutters of 851 mm to 1000 mm in width and of weight between 61 to 80 Kg of aluminium body complete all as specified and as directed. |
| 74 | Dismantling water tanks ofany decription exceeding 500 litres capacity and not exceeding 1000 litre capacity including making good disturbed surfaces to match with existing surfaces complete all as specified and as directed. |
| 75 | S & F Rotational Moulded Polythene [HDPE] Water Tanks, Double Layered, ISI Marked, Cylindrical & Vertical Type 5000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes including dismantling and taking out existing unserviceable PVC tanks of any description and capacity complete all as specified and as directed. |
| 76 | M & L for Powder coated aluminium sections [Minimum 50 Micron thick] of approved colour for Doors, Windows, Ventilators, Partitions with frame and shutters fully or partly glazed, sliding / openable including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges, locking arrangementsetc., complete all as specified and as directed.Notes:[a]The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I. [b] Panel inserts such as Glass / Particle board / Gauze shall be measured and paid separately at supply only rates.[c] Weight of aluminium sections shall only be accounted for payment purpose. Weight of aluminium Handles, Butt Hinges & Tower Bolts shall not be accounted for payment purpose. [d] The unit rate quoted shall be deemed to include for cost of jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges, locking arrangementsetc., and fixing only of panel inserts ofglass / particle board / gauge etc. |
| 77 | Supply onlyStainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mmwith tinned tacks or Aluminium wire staplescomplete all as specified and as directed. |
| 78 | Supply only 5.5mm thick Tinted Glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed. |
| 79 | Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces, ceiling surfacesetc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance exceeding 1.50 KM but not exceeding 5.0 KM complete all as specified and as directed. |
| 80 | M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 81 | M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 82 | M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 83 | Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed. |
| 84 | M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed. |
| 85 | M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4including 2 Nos of 8mm dia bars at every fourth course of brick work complete all as specified and as directed. |
| 86 | M & L for preparing newly plastered wall surfaces by using vaccume based sanding machineandapplying two coats of Acrylic washable Distemper by using auto roller/airless sprayer, over a coat of alkali resistant primer over 1mm thick Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfacescomplete all as specified and as directed.Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicatorsbefore commencement of the work to GE for approval. |
| 87 | M & L for Complete removal of existing treatment of any description on wallsurfaces by using vaccume based sanding machine, removal of nails and applying upto 1mm thick Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one of alkali resistant primer on wallsurfaces complete all as specified and as directed.Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicatorsbefore commencement of the work to GE for approval. |
| 88 | M & L for Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Exterior Primer over 1mm thick Cement based Wall Care Putty [primer and putty shall be of same manufacturer as that of exterior emulsion paint] by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty on newly plastered walls/ ceiling, pillasters, bands, borders, soffits of chajjas and projections including rubbing with sand paper to obtain a smooth surfacecomplete all as specified and as directed.Note:- The contractor shall carryout Exterior Emulsion Painting and allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Exterior emulsion painting through their authorised applicatorsbefore commencement of the work to GE for approval. |
| 89 | M & L for Complete removal of existing treatment of any description on walls/ ceiling, pillasters, bands, borders, soffits of chajjas and projections by using vaccume based sanding machine, removal of nails including rubbing with sand paper to obtain a smooth surfaces and applying Two coat of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Exterior Primer over 1 mm thick Cement based Wall Care Putty [primer and putty shall be of same manufacturer as that of exterior emulsion paint] by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty complete all as specified and as directed.Note:- The contractor shall carryout Weather proof Exterior Emulsion Painting under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Weather proof Exterior Emulsion Painting through their authorised applicatorsbefore commencement of the work to GE for approval. |
| 90 | M & L for two coats of white wash on old decorated surfaces of wall etc including necessary preparation by brooming down or steel wire brushing complete all as specified and as directed. |
| 91 | M & L for walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in Cement Mortar 1:4 complete all as specified and directed. |
| 92 | M & L for providing designer texture finish on walls after preparation all as specified. |
| 93 | M & L for Plaincement concrete Type B1 [Nominal Mix] 1:2:4 using 20mm graded stone aggregatein lintels,bands etc up to 1.5m span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work, complete all as specified and as directed. |
| 94 | M & L for Raised Pointing in Cement Mortar 1:3 to random rubble uncoursed or brought up to coursed masonry complete all as specified and directed. |
| 95 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling,uncoursed or brought face from straight edge held against the dressed surface not exceeding 40mm complete all as specified and directed. |
| 96 | M & L for One coat of synthetic enamel paint on old painted wooden surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed. |
| 97 | M & L for One coats of synthetic enamel paint on old painted steel surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed. |
| 98 | M & L for preparing newly plastered Ceiling surfaces and applying three coats of white washing complete all as specified and as directed. |
| 99 | Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance exceeding 1.50 KM but not exceeding 5.0 KMcomplete all as specified and as directed. |
| 100 | M & L for 100 mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded stone aggregate as in Pavement / Hard standing etc, surface of concrete roads, pavements finished by brooming, laid in alternate bays complete all as specified and as directed. |
| 101 | M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 102 | M & L for Inter Locking Paving Blocks of 80mm thick, made with M-40 Grade cement concrete using 20 mm graded stone aggregate, Hydraulically pressed of approved colour and pattern, shape and size conforming to IS - 15658 set in floors including taking down existing paver blocks of any description and size complete all as specified and directed. |
| 103 | M & L for PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate as in benching, channel, side packing, haunching of paver blockincluding necessary form/ moulds, etc.complete all as specified and as directed. |
| 104 | M & L for PCC 1:2:4, Type B-2, using 20mm graded stone aggregate as in Coping of electric pole etc. complete all as specified and as directed. |
| 105 | S & F in repairs 15 mm thick Toughened Glass as inhinged glass doors, Partitions, automatic doors and necessary stainless steel fittings and fixtures including cutting to shape , drilling holes as required all as per manufacturers instructions as specified and as directed by Engr-in-charge. |
| 106 | S & F 18mm thick Plywood, Grade BWR, Type BB, fixed with nails to Wooden Frames complete all as specified and as directed. |
| 107 | S & F 0.9 mm thick Decorative Laminate, Type - 1 of Surface Finish, Colour and Pattern as approved, fixed with approved adhesive as per manufacturer\"s instructions, complete all as specified and directed. |
| 108 | Providing & Laying of Laminated Wooden Floor tiles 8mm to 10mmnthick of AC-5 Grade with laying of Polyurethane sheet with foaming as perdesign complete with installation in designated area complete all as specified and directed. |
| 109 | Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance not exceeding 1.5 KM complete all as specified and as directed. |
| 110 | M & L for RCC 1:1½:3, Type A-1, using 20mm graded stone aggregate for slabs suspended on walls,beams and coumns, in floor,roofs,landings and in shelves and the like etc complete all as specified and as directed. |
| 111 | Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including fair finished surfaces complete all as specified and directed. |
| 112 | M & L for providing Precast Cement Concrete Louvers and Jallies, Type, B0, 1:2:4, using 12.5mm Graded Aggregate, 50mm thick [measured solid], including all mouldings but excluding frame, set in Cement Mortar 1:4 including demolition of existing Jallies of any description and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. |
| 113 | Clearing the blockages in sewage lines of any dia by rodding or by other mechanical means in between man holes and flushing with water all as directed by Engineer-in-Charge. |
| 114 | M & L for Non Returnable Grouting Packer of 8mm dia, inserting into concrete by drilling hole of 10 mm dia in a staggared manner as directed by the engineer-in-charge including supply and injection of approved two component low viscosity epoxy grout in position, including all equipment, putty, machinery, tools as recommended by the Manufacturer and making good the surfaces complete all as specified and as directed.Make of epoxy grout: M/s. Fosroc Chemicals/ M/s. Sika India Pvt. Ltd./M/s. STP Ltd./M/s. Choksey Chemicals Pvt. Ltd./ M/s Bostik India Pvt. Ltd./ M/s Asian Paints Ltd. |
| 115 | M & L for drilling and fixing PVC Nozzles and injecting Polymer modified cementitious epoxy grout as required to fill the honeycombing inside the beams, columns, slabs etc. noticed after removal of loose concrete complete all as specified and as directed.Make of epoxy grout: M/s. Fosroc Chemicals/ M/s. Sika India Pvt. Ltd./M/s. STP Ltd./M/s. Choksey Chemicals Pvt. Ltd./ M/s Bostik India Pvt. Ltd./M/s Asian Paints Ltd. |
| 116 | M & L for Cleaning the existing exposed reinforcement of slab, beam, column, footing etc. and any other RCC structural member by emery paper, providing two coats of Single Component Rust Removal And Rust Inhibition Liquid including all necessary formwork, scaffolding and safety measures complete as per manufacturer\"s instructions, as specified and as directed. Make of Rust Removal And Rust Inhibition Liquid: Sika Rustoff 100 of M/s. Sika India Pvt. Ltd. or equivalent approved rust remover/ Preventer in M/s. Fosroc Chemicals or M/s. STP Ltd. orM/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd./ M/s Asian Paints Ltd. |
| 117 | M & L for preparation of existing exposed steel surfaces free from dust, loose material, surface contamination, rust, scale, mortar, concrete, other loose and deleterious materials, materials which reduce bond or prevent suction or wetting by repair materials, delaminating, weak, damaged and deteriorated concrete by blast cleaning or other means of mechanical abrasion or suitable means, making substrata to Saturated Surface Dry [SSD] with no standing water and applying cement-based epoxy modified three-component anti corrosive coating and bonding slurry using Friazinc R of M/s. Sika India Pvt. Ltd. or equivalent approved bonding agent in M/s. Fosroc Chemicals or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer\"s instructions as in rebar corrosion protection system including all necessary formwork, scaffolding and safety measures complete all as specified and as directed. |
| 118 | M & L for applying Polymer Modified Mortar made using Shrinkage Compensated Polymer Modified Fibre Reinforced Cementitious Repair Mortar such as Renderoc SP 40 of M/s. Fosroc Chemicals India [P] Ltd. or equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer\"s instructions to form average 25 mm thick even surface complete all as specified and as directed. |
| 119 | M & L for Micro Concreting for jacketing of Columns using Single component, shrinkage compensated, high strength, high flow cementitious micro-concrete having compressive strength minimum of M40 at 28 days such as Sikkarep Microcrete-4 of M/s. Sika India Pvt. Ltd. or equivalent in M/s. Fosroc Chemicals India [P] Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer\"s instructions blended with washed saturated surface dry [SSD], graded, low absorption, high density, aggregates of size 3mm to 10mm at 50% by weight of micro concrete [if thickness is 100mm or more] and water as per data sheet and pouring into the shuttering if required using birds beak type form work using suitable arrangement or if required using pumping device for uniform flow of Micro concrete complete all as specified and as directed. Note: The sides shuttering shall be removed preferably after 3 days and the bottom shuttering shall be removed preferably after 7 days ensuring proper bond between the micro concrete and existing concrete substrate. |
| 120 | M & L for providing additional reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D by checking the diameter of the existing bars, cutting the necessary main reinforcement to the required length with proper development length, tying / binding / welding with the existing shear connectors / reinforcement so that the additional reinforcement acts monolithically with the existing reinforcement and core concrete complete all as specified and as directed. Note: The shear reinforcement shall also be provided as specified here-in-above in the form of 2 \"U\" shaped bars if existing shear reinforcement is found deteriorated / diameter of the bars is reduced. Diameter of the new bar shall be equal to the existing bars. Additional reinforcement shall be provided only in case the diameter of the existing bars is found less than 30% of the original diameter. |
| 121 | M & L for removing Plants with roots by chipping Walls / Beams / Junctions of Vertical Stacks / Water Supply lines or at any other location as directed, applying recommended chemical to prevent growth or plants and making good the disturbed portion with Cement Mortar 1:3 or with PCC 1:2:4, Type B0 [using 12.5 mm graded aggregate] and painting the surfaces to match with existing treatment / finishes and removing debris to a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as directed. |
| 122 | Supply and fixing of bold metallic stainless steel letters and alphabets made with SS plain sheet made out of 22 guage thick and 304 grade SS plain sheet of suitable width not less than 50mm and depth/thick not less than 20mm based on height of letter (hollow section made to shape by using computerised cutting), the height of letter/ alphabet shall not be less than 15\" in hindi and english languages and fixed on ganite wall cladding/ tiled finished walls, elevated from the surface complete all as specified and as directed |
| 123 | Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed. |
| 124 | Taking down existing unserviceable Main Switches, MCCB DBs, MCB DBs, SPN Enclosures including MCCBs, MCBs etc of any description and any capacity and making good the disturbed surfaces all as per existing complete all as specified and as directed. |
| 125 | Taking down carefully submain wiring of any description and size complete including wooden battens / conduits / casing capping and making good the disturbed surfaces all as per existing complete all as specified and as directed. |
| 126 | M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, Two runs, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Metal GI Flush Box of suitable size and thickness including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by one way switch complete all as specified and as directed.Note: The rate quoted shall be deemed to include cost of cutting chases not exceeding 10 cm girth, pinning in brick walls and making good in cement mortar as required. |
| 127 | All as per Serial Item No. 126 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified. |
| 128 | All as per Serial Item No. 126 above but One 3 Pin Switch Socket Outlet 5 Amps on same Board with other switch complete all as specified. |
| 129 | All as per Serial Item No.126 above but one 15 Amps power point on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor. |
| 130 | S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed. |
| 131 | S & F Switch Modular type, one module, Single pole, one way, 16 Amps, 230 Volts complete all as specified and as directed. |
| 132 | S & F Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed. |
| 133 | S & FSocket Outlet, 3 pin, 16 Amps cum 2 pin 6 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed. |
| 134 | S & F Electronic Fan Regulator, Stepped Type, Modular Type, Two Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed. |
| 135 | S & F Ceiling Rose, PVC Body, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed. |
| 136 | S & FSPNsheet metal enclosure, Modular type, with two pin and earth plug and socket, with andincluding One MCB, SP, 20 Amps, 10 KA, C curve, 240 Volts complete all as specified and as directed. |
| 137 | M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit. |
| 138 | M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit. |
| 139 | M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed.Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit. |
| 140 | S & F MCB DB, VTPN, 6 Way, 415 Volts with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed. |
| 141 | S & FMCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wallcomplete all as specified and as directed. |
| 142 | S & FMCB DB, SPN, 12 Way, 240 Volts, with DIN Channel, Double Door with 100 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed. |
| 143 | S & F MCB, SPN, 40 to 63 Amps, 10 KA, C Curve, AC, 240 Volts, 50 Hz complete all as specified and as directed. |
| 144 | S & F MCB, SP, 6 to 32 Amps, 10 KA, C Curve, AC, 240 Volts, 50 Hz complete all as specified and as directed. |
| 145 | S & FMCCB415 V , 16 KA, 4 Pole, 125 Amps capacity complete all as specified and as directed. |
| 146 | S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 2000 Lumens output, 5700 K of cool white, with extruded aluminium housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing unserviceable tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 147 | S & F Energy efficient Sleek LED Mirror Light Fitting of not less than 1000 Lumens, Surface/ Recessmounted with Acrylic / PMMA diffuser for soft glare free light with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mmincluding taking down existing unserviceable light fittings of any description and making good disturbed surfaces complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 148 | S & F Energy efficient Post Top Lantern, of not less than 3500 Lumens output, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection, electronic driver, all accessories internally prewired and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 149 | S & F Energy efficient & Long life Street Light Luminaire, of not less than 3500 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing unserviceable light fittings of any description and making good disturbed surfaces complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 150 | S & F Square recessed mounted Flat Panel 36 Watt 2\" x 2\" LED Ceiling Light suitable for fixing in 2\" X 2\" Grid False Ceiling of not less than 3600 Lumens output,, 6500 K, with high transmitive diffuser for soft-light and glare free symmetrical illumination with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 151 | Supplying, laying and testing XLPE insulated and PVC sheathed,armoured heavy duty underground cable, ISI marked with stranded aluminium conductor 1100 Volt grade of size 3.5 Core, 50 Sq.mm cross section conforming to IS 798 suitable for earthed system, laying in trenches / duct/ fixed to poles / drawn through pipes / sleeving through pipe in duct, including crimping type cable lugs, sockets etc. including taking down existing un-serviceable cable of any description and size complete all as specified and as directed. |
| 152 | S & F Exhaust Fan, 250mm Sweep, 1400 RPM, PVC Body, Conforming to IS - 2312, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, BEE 5 Star Rated, colour as approved including Louvered Shutter/ Grill, including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and fixing in existing opening and making good the disturbed surface to match with existing and taking down existing ceiling fan of any description and depositing at MES Store Yard complete all as specified and as directed. |
| 153 | M & LEnergy efficient, Low noise, wall mounted oscilating Fan, 450 sweep, BEE 5 Star rated,Copper Wound, 1350 RPM, Suitable for operation on Single Phase, wattage consumption not more than 65 watts, 240 Volts, AC, 50Hz, confirming to IS.Thermal over load protection with smooth neck tilting provision including wall bracket/Clamp and mounting accessories kitcomplete all as specified and directed. |
| 154 | Taking down old unserviceable aluminium/GI earth strip and making good the disturbed surfaces all as per existing complete all as specified and as directed. |
| 155 | Taking down old unserviceable Air termination rod making good the disturbed surfaces all as per existing complete all as specified and as directed. |
| 156 | S & F Single Pointed Air Termination Aluminium Rod 12 mm dia and 300 mm long including necessary fasteners fixed for Lighting Protection with necessary connections to earthing etc complete all as specified and as directed. |
| 157 | S & FAluminium Strip of size 25 X 3.15 mm, fixed to walls / columns / beams etc with Saddles or porcelain blocks of 10mm thick spaced at 1.00m centre to centre including making grooves and fixing with brass screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note: Hylam sheet block shall be in two pieces each 10mm thick, one fixed to base with brass screws and the other fixed over it with brass screws after fixing aluminium strip in the groove provided. |
| 158 | S & F in repairs Earth continuity conductor or main earthing lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed. |
| 159 | S & FTest Point Terminal Box of size 175 X 150 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws, painting with two coats of specified color over a coat of red oxide zinc chrome primer complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed. |
| 160 | Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. including taking down of existing earthing set complete all as specified. |
| 161 | Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. including taking down of existing earthing set complete all as specified. |
| 162 | Supplying and laying GI pipe, 80mm dia, Light grade for Earth continuity conductor or main earthing lead protection laid in trenches or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail