Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-10-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 14-10-2024 |
| Sl. No. | Item Description |
| 1 | Hardcore of broken bricks gauge n exc. 63 mm , deposited , spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface. complete all as specified and directed |
| 2 | M&L for Continuous Kerb Stone edging with pre-cast cement conrete ( 1:2:4) type B-I using 20 mm gradedaggregate ( Size of kerb stone 300x100x450mm), with plain fair faces with or without chamfered edge laid on end vertically and set in cm (1:4)complete all as specified and directed. |
| 3 | Material & Labour for 75 mm thick PCC type C-2, (1:3:6) using 40mm graded stone agrregate as in sub base of floors etc complete all as specified and directed by Engr-in-Charge |
| 4 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25 mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sandbedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. complete all as specified and directed by Engr-in-Charge |
| 5 | M&L Earth filling under floors or in foundations including watering and consolidation. complete all as specified and directed. |
| 6 | Material and labour for PCC 1:2:4(type B-0) as, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.complete all as specified and directed. |
| 7 | Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified. |
| 8 | M&L Brick work with sub class \"B\" bricks straight or curved on plan exceeding 6m mean raidus bulit in C:M 1:6 all as specified. |
| 9 | M&L for PCC 1:5:10 type E-2 (using 40mm graded stone agg) as in foundation filling, complete all as specified & directed |
| 10 | M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius in cement mortar (1:6), using old bricks, complete all as specified and directed by engineer in charge.Note : Bricks retrieved from item no 7 shall be used after proper cleaning. |
| 11 | Removing mortar from and cleaning bricks, stacking for measurement including all extra handling and removal and disposing off rubbish complete all as specified and directed by engineer in charge |
| 12 | M&L for cement plastering 15mm thickin cemet mortar 1:4 including mixing of liquid water proofing. complete all as specified and as directed by Engineer-in-Charge.Note : WPC shall be measured and paid separately. |
| 13 | M&L for Applying 02 coats of cement paintby using roller to wall surfaces complete all as specified and directed. |
| 14 | Supply only integral water proofing compound complete all as specified & as directed by Engineer-in-Charge |
| 15 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers n. exc. 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface in soft/loose soil complete all as specified and directed. |
| 16 | M&L PCC in foundations, filling and mass-concrete type C2 (1:3:6) using 40 mm graded stone aggregate as in filling in fdn of post holes comlete all as as specified and directed. |
| 17 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 complete all as as specified and directed. |
| 18 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment along with the necessary required welding, along with the cleats complete all as as specified and directed. |
| 19 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified. complete all as specified and directed |
| 20 | Material & labour for preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer complete all as specified |
| 21 | Surface exc n.exc 30 cm deep and averaging 15 cm deep and geting out in Hard/Dense soil complete all as specified and directed. |
| 22 | Excavation in trenches n.exc 1.5 M wide and n.exc 1.5 in depth for foundation and getting out in soft/loose soil. |
| 23 | Returning filling including spreading,levelling watering and well ramming in layers not exc 25 cm thick each. |
| 24 | Removing excavated surplus spoil to a distance not exc. 50 M and depositing where directed at a level not exc.1.5 M above the starting point complete all as specified and directed. |
| 25 | Hard core of broken stone or boulders n exc 63mm, deposited, spread, leveled in layers n exc 15cm thick each layer including watering and well ramming to a true surface. |
| 26 | M&L 100mm thick Sub base type C-1, (1:3:6) using 20 mm graded stone aggregate..complete all as specified and directed. |
| 27 | M&L 100mm thick PCC type B-2, (1:2:4) using 40 mm graded stone aggregate as in floors finished even and smooth without using extra cement. |
| 28 | Forming Contraction (Dummy) joints,filled with sealing compound \"A\".complete all as directed by Engr-in-Charge and complete as specified. |
| 29 | Demolition of Concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level), complete all as specified and directed. |
| 30 | M&L Damp proof course 40mm thick in cement concrete 1:2:4 type B-0 to horizontal or vertical surfaces including necessary formwork along with Polythene film, 150 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m complete all as specified and directed. |
| 31 | M&L RCC TypeB0 1:2:4(12.5mm graded aggregate) nominal in lintels , chajjas ,Lintel Beam at any height along with the required formwork etc complete all as specifed . |
| 32 | M&L Mild steel bars(TMT) 10mm dia and over in lintel, lintel beam, chajjas, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 33 | M&L Mild steel TMT bars 6mm dia & over upto & including 10mm dia in stirrups, spacers & binders, cut to length, bent to shape required, binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality etc complete all as specifed . |
| 34 | Taking down cement plaster on brick or stone walls or concrete surfaces, etc, any description including raking out joints, hacking for key, scrubbing down with water, etc and removal of rubbish outside MoD land, complete all as specified and directed by engineer in charge |
| 35 | M&L for rendering 10mm thick in CM 1:6 on brick or concrete surfaces of walls, finishing even and smooth without using extra cement. |
| 36 | Preparation of new plastered or unplastered surfaces of cieling and applyingtwo coats of white washing complete all as specified and directed. |
| 37 | M&L for applying wall care putty on internal/external surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed |
| 38 | Applying 02 coats of oil bound distemper (light shade)by using roller to wall surfaces over & including a coat ofprimercomplete all as specified and directed. |
| 39 | Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hardcore, etc.. to store and rubbish not exc. 50m,complete all as specified and directed. |
| 40 | S&F factory madePressed steel door frames(125X60mm) made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified |
| 41 | Supply & fixing factory made flush shutters 30mm thick, 7 Ply, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed |
| 42 | Supply & fixing 30mm thick glazed and skelton shutters of 1st class soft wood (factory made) open rebated and divided to receive glass, gauze etc (with sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Pt-1 section 8 clause 8.24(a) supplied and fitted to chowkhats complete all as specified and directed |
| 43 | S & F Steel factory made window box type usning ERW hollow \"P\" section comprising double frame for and including gauged and glazed Skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, etc including 8mm square gaurd bars all as shown on drawing No TD-191 (R) sheet 1/4 to 4/4 complete all as specified and directed by Engr-in-charge.Note: TD drg can be seen in the office of Engr-in-charge. |
| 44 | S&F Butt hinges 100 mm size, mild steel butt hinge pin, bright polished and fixed, typeB-12 complete all as specified and directed. |
| 45 | Supply & Fixing Aluminium handles125mm, cast type, anodised complete all as specified and directed. |
| 46 | S&F Aluminium alloy, anodised, sliding door bolt 250 mm length(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy and fixed complete all as specified and directed |
| 47 | Aluminium anodised, barrel tower bolts of 200 mm size of extruded section and fixed complete all as specified and directed. |
| 48 | Floor door stopper of size 140 mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 49 | Supply & fixing 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate including necessary welding to chowklhats complete fixed all as specified |
| 50 | Supply & fixing stainless curtain rod 25 mm dia , mild steel, chromium plated with fixing brackets, stops, rollers etc for curtain rodcomplete all as specified and directed by Engineer-in-Charge |
| 51 | Supply & fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40mm and fixed in repair with stainless steel wire stapples, in steel/wooden frame complete all as specified and directed |
| 52 | Material & labour for Preparation of new wood surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified |
| 53 | Complete removal of existing treatment of any type/description from walls/RCC surfaces etc with mechanical means/grinder complete all as specified and directed. |
| 54 | Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified |
| 55 | Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqmincl cutting holesand making good reqd shape for hold fast block for new frame complete all as specified. |
| 56 | S&F factory made Pressed steel door frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,(105X60mm) etc., complete as specified |
| 57 | M&L PCC (1:3:6) type C1 using 20mm aggregate as infilling in Chowkhats/Holdfast, benching purpose and filling up of post holes. complete all as specified and directed. |
| 58 | Cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints complete all as directed by Engr-in-Charge and complete as specified. |
| 59 | S&F, Factory made steel windows or ventilators, fixed type with glazing bars complete all as specifino and directed by Engr-in-Charge. |
| 60 | Supply & fixing of 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane, fixed in repair complete all as specified and directed |
| 61 | Supply & fixing of 3 mm figured glass, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane, complete all as specified and directed |
| 62 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings,complete all as specified and directed |
| 63 | S& F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. |
| 64 | S&F Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall bemeasured and paid separately) |
| 65 | Dismantling of Stone slabs & tiles of any description or thickness in floors, aprons etc. Laid, bedded & pointed in any mortar, complete all as specified and directed by Engineer-in-Charge. |
| 66 | M&L Non - skid Ceramic tiles(600mmX600mm)(joint free) 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchand including 15mm thick rendering in cement mortar 1:6 , complete all as specified and directed by Engineer-in-charge. |
| 67 | Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion incement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required. (exc half brick but not exceeding one brick) complete all as specified. |
| 68 | S&F Built in cup boards with pressed steel frame of size 75x45x1.25mm thick and shutter of 1.00 mm thick MS sheet including spray painting 2 coats over a coat of red-oxide primer on steel surfaces all around all shown on drawing No TD-178 sheet 2/3 to 3/3 dated 12 May 2001 (overall external size of cup board shutter incl frame shall be taken into consideration for the purpose of measurement) completeincluding One No hanging rod of CP steel 20mm bore with brackets & two Nos peg set of three pegs each fixed inside the shutter complete fixed in repairs i.e, including taking down and removal of old unserviceable wooden or steel built-in-cupboards incl frame from site all as specified and directed by Engineer-in charge.Note: TD drawing may be seen in the office of Engr-in-charge. |
| 69 | Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating. SmartCare Damp Block 2K or approved equivalent, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturer specifications |
| 70 | Takingdown carefully existing points wiring on surface conduit/concealed conduit including conduit from surface and expect conduit in concealed wiring for light/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etcremoving materials to store for keeping in safe custody of contractor for which the credit has been considered under schedule of creditand making good the disturbed portion of all floor, ceiling etc all as specified and directed. |
| 71 | M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor for one light/fan/bell point in and including NEW PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in pressed steel terminal boxes with PVC modular top cover plates of suitable size for mounting of modular type switches/sockets/regulators including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including cutting chases and making good the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engr-in-charge.Notes: (i) Cost of Pressed steel Terminal Boxes and modular Top cover plate shall be included in point wiring. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth.(iii)-Cost of Eye/bottle thimblesused for connection in switches/sockets & MCBs in DBs shall deemed to be included in the unit rate quoted for this item. |
| 72 | All as per Sl item No 71.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed. |
| 73 | All as per Sl item No 71.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed. |
| 74 | All as per item No.71.00 herein beforebut 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSHcopperearth wire for switch socket combination 3 pin 15 amps on independent board. |
| 75 | S&FModularswitch1 way, 6 Amps, 1 module, 230 volts complete all as specified. |
| 76 | S&FModularswitch1 way, 16 Amps, 1 module, 230 volts complete all as specified. |
| 77 | S&FModular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified. |
| 78 | S&FModularsocket 5 pin 6 &16 Amps, combination type2 module complete all as specified. |
| 79 | S&FModular Fan regulator step type, 120 watts, 2 module complete fixed as in repair all as specified. |
| 80 | S&F ceiling rose surface bakelite surface 65 x 50mm3 terminals all as specified & directed |
| 81 | S&F New generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07,with all accessories including suitable bracket with 20 mm bore light grade GI pipe bemd to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge. |
| 82 | S&F Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqm Copper conductor Earth wire shall be measured as one unit)Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.(ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc.10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring. |
| 83 | S & F MCCB, 4 Pole, 100 A, 16 KA for fixing in DB including proper thimble connection, thermal and magnetic release protectioncomplete all as specified and directed by Engineer-in-charge. |
| 84 | Supply and fix in replacement of epoxy power coated MCCBdistribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with commen bus-bar at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified by Engineer-in-charge. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimblesused for connection MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.(iii) connection of theMCCBs/ MCBs with cableshall be made through appropriate size pin /bottle type thimble -properly crimped. all the vacant holes of the DB shall be provided with blank plates of appropriate size. |
| 85 | Supply and fix in replacement of Sheet metal enclosure 8 ways double door for DBs when MCBs areto be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link allflush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed byEngr-in-charge. |
| 86 | MCB , SPN B curve, 240 Volts ,32-40 amp for fixing in DBs ofincluding proper thimble connections complete all as specified and directed by Engineer-in-Charge. |
| 87 | MCB, single pole B curve 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge. |
| 88 | M & L in replacement of UNSV Earthing complete with galvanized iron earth plate electrode of size 600x600x6.0mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts , nuts , check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 |
| 89 | S & F in replacement Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in squareLED Batten 18/20W 6500Kof capacity ,20 watt,4 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed by Engr-in-charge. |
| 90 | S & F Exhaust fan AC single phase 230/240 v of size 450 mm sweep heavy duty 1400 rpm metal body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including Louver , making hole for exhaust fan 450 mm complete all as specified and directedby Engineer-in-Charge. |
| 91 | M & L for Sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH,stranded copper conductor cable drawn through New PVC concealed conduit 25 mm dia including 4.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runsof 4.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Runof 4.0 Sqmm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this items shall be inclusive of the cost of(i) Rigid non-metallic PVC conduit of 25 mm dia withtees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.(ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc.10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring. |
| 92 | Supply and fixingsingle pole and neutralenclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed by Engineer-in-charge. |
| 93 | Supply and fix ElectricWater heater (Geyser) storage typeof capacity 25 ltr BEE 5 star rated, ABS body, metal tank with glass lined coating multiple heating option, shock safe plug puf insulation, incoly glass coated anode rod/copper heating element with ISI mark, adjustable knob for temp setting with minimum&high working pressure, multi functinoal saftey value, & whirl/swril flow technology, themostat electronic type, complete including superior quality PVC connection pipe heavy duty 15 mm dia 450 mm long, brass adopter for water connection with nickel coated ISI marked with fastener, nut bolt, washers duly grouted, giving shape to hole as suitable and plastering including making good of disturbed surface as per exisiting surface connection to inlet and outlet valves, testing complete all as specified and dirceted by Engineer-in-Charge |
| 94 | S & laying GI tubing \"medium grade\" 15 mm bore with all necessary fittings like elbow, reducer, T-joint, nipple and passing throughbrick walls, ceilling or laying in floors, tapping from existing lines and necessary cutting, chasing of walls etc complete all as specefied and directed. |
| 95 | Supply and fixStop valve cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe of bore 15 mm Chromium plated fancy type completeall as specified and directed. |
| 96 | Supply and fix Bib tap cast copper alloy chromium plated, fancy type, with capstain head handle screwed down screwed for iron pipe and fixed to 15mm bore pipecomplete all as specified and directed by Engr-in-charge. |
| 97 | Taking down and refixing of ceiling fan after necessary overhauling, replacement of bearing,cleaning painting making serial No complete all as specified and directed by Enginner-in-charge.Note:- Cost of supply & fixing of celing fan box round cover plate is included in the unit rate quoted by contractor. |
| 98 | Supply & fixing down rodfor ceiling fans made out of MS pipe 15mm bore medium grade 120 cm long duly threaded, holes drilled and spray painted with synthetic enamel paint all as specified and directed by Engr-in-Charge |
| 99 | Supply and fixRecess mounted LED luminaire 36 watt suitable for gridd celling cutout dimensions: 2x2 Ft. incl connecting with twin core copper wire from ceiling rose to fitting, Fixture size: (LxWxH) in (595x595x65) mm incl lamp and driver complete all as specified & directed. |
| 100 | XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core supplied& laid in replacement complete all as specified& directedby Engineer-in-Charge. |
| 101 | Material and labour for sand cushioning for cables 8 cm below the cable and 15 cm abovewith dry river sand in trenches for cushioningof underground cable line including spreading, leveling, well ramming completed all as specified and directed. |
| 102 | M&L Cutting of hardstanding floor/wall minimum 75 mm wide and 75 mm deep for laying of cable including matching with suface by using cement concrete type B-1 (1:2:4)all as specified and directed. |
| 103 | Supplying & laying factory made unreinforced Precast concrete cable coversclass LV type 1, flat, Size 250x150x40mm laid in trenches as protection to cables completeall as directed by Engr-in-Charge |
| 104 | Material and labour for replacement of GI tubing light grade 40 mm borefor passing through cables under the floor ,along the wall or along the pole complete all as specified and directed. |
| 105 | Supply and installation of Desert cooler with outer body made of PGI (plain Galvanised Iron) sheet not less than 1.20 mm (18 gauge)thickness for fixed part, thickness of PGI sheet for shutter not less than 0.80 mm (21 gauge) thick front grill made of PGI Sheet with minimum weight 2.80 kgs overall outer size not less than 66cmx66cmx85 cm (height) electric driven copper wounded fan motor (ISI marked)having nominal air flow capacity 4000 Cum per hour and capacity of water storage tank not less than 40 ltr and submersible pump for required flow of water single phase) complete all as specified. Make of fan motor/Submersible pump :Crompton/Khaitan/Bajaj/Havells |
| 106 | Supply , fabricating and fixing angleiron frame made out of 40x40x5 mm thick suitable for fixing ofDesert cooler includingnecessary civil work, making good the disturbed portionof wall includingcolour/whitewash as per existingsurface complete all as specified and directed by Engr in Charge.Note: Cost of PCC,Making hole into wall and one red oxide primer coat ,one under coat and one finishing coat ofsynthetic enammel paint is included in this item. |
| 107 | M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all accessories ie PVC gutties etc terminated insunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for the One socket outlet point 6 A on independentboard. Note:- Cost of modular cover plate and metal flush boxes is deemed to be included in the unit rate quoted by contractor. |
| 108 | Supply , install , testing and commisioning of Solar hotwater Heating system of 300 LPD Capacity thermosyphon type consisting of: a)SSSPL/Solartech/Surya Shakti of ISI Marked solar flat plate collector of 1240mm x 1860mm x 110 mmhaving cu-cu selectively coated(black chrome coating) absorber of 2.12 sqm having 10 risers and Al.box with 4 mm toughned glass all as per OEM specificationb) Insulated strainless steel hot water storage tank 500 Ltr of 1 mm thick sheet cover with 100 mm thick of rockwool insulation & 26 SWG A1 or MS power coated sheet -01 Nos.c) Temprature Guage - 01 Nosd) Gunmetal gate valve- 01 Nose) piping in between the system - 01 Setf) duly painted MS angle iron stand for tank & collector - 01 Setg) Sacrificial anode - 01 Nosh) Electrical Backup of3KW Set - 01 Nos |
| 109 | Supply and fix 25 mm dia Stop valves, cast copper alloy, screwed down,high pressure,with crutch orbutterfly handle, screwed both ends for iron pipe or forunions and fixed complete all as specified and directed. |
| 110 | Supply and fix 20 mm dia Stop valves, cast copper alloy, screwed down,high pressure,with crutch orbutterfly handle, screwed both ends for iron pipe or forunions and fixed complete all as specified and directed. |
| 111 | Supply and lay GI Pipe , Medium gradecomplete including fittings 25 mmdiacompleteall as specified and directed.. |
| 112 | Supply and lay GI Pipe , Medium gradecomplete including fittings 20 mmdiacompleteall as specified and directed. |
| 113 | M&L for Lagging to pipes used in internal water supply or plumbing all round with25 mm thick bonded mineral wool performed SNAPON pipe sectionof density 144 kg/cum conforming to IS 9842 forinternal 20 mm dia of pipe completeall as specified and directed. |
| 114 | Supply, fabrication and fixingof mild steelframe/staging / height for placing of cold water tank for solar water heater made out of mild steel angle iron, MS flat, plates etc. includind nut, bolts etc. including welding ,bending cold , or hot in any shape or sizeas indicated or directed and inclusive of one red oxide primer coat ,one under coat and one finishing coat ofsynthetic enammel paint including grouting in PCC block of 1:2:4 complete.(PCC to be measured and paid for separately in respective section)complete all as specified anddirected.. |
| 115 | M&Lforcement concreteinfoundations, filling for solar heating system type ofB2 1:2:4 using20 mm gradedaggregatecomplete all as specified anddirected. |
| 116 | S&F Rotational moulded polythene water storage tanks(double layer)(cylindrical vertical with closed top) hoisted and fixed in position all as specefied in SSR part I Of capacity 500 Ltrs capacity complete all as specified anddirected. |
| 117 | S &F 15 mm boreBib tap chromium platedwith crutch or buttterfly handle ,screwed down , screwed for iron pipe or for brass ferrulecomplete all as specified anddirected. |
| 118 | Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe for 25 mm bore weight of 455 gms. (for cold water tank)complete all as specified anddirected. |
| 119 | Supply and fixSheet metal enclosure 4ways double door for DBs when MCBs areto be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link allflush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed byEngr-in-charge. |
| 120 | XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core supplied& laidcomplete all as specified& directedby Engineer-in-Charge. |
| 121 | S & F gun metal gate valve, suitable for 15mm bore GI pipe with iron wheel head, screwedboth end for GI pipe with all necessary fittings complte all as specefied and directed. |
| 122 | Supply and fixingsingle pole and neutralenclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps, complete all as specified and as directed by Engineer-in-charge. |
| 123 | Supply and fixing PVC connections wire impregnated 15 mm bore suitable for hot water with PTMT nuts of length 450 mm of 6 kg/cm2 pressure rating with two sets of mild steel chromium plated adopters one at each endsuitable for fixing to 15 mm dia GI pipe tubing complete all as directed by EIC |
| 124 | Cutting/drilling or tapping from existing 15mm or 20 mm dia pipe in position for branch connection of 15 mm dia pipe including suitable fitting and fixtures all as directed by EIC |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail