Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-10-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 10-10-2024 |
| 2 | 28-09-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 05-10-2024 |
| Sl. No. | Item Description |
| 1 | Supply and fix air termination, single pointed, copper 12mm dia and 300mm long complete all as specified and directed. |
| 2 | Supply and fix copper strip 20mmx3.15 with saddles and fixing screws etc for roof conductor and down conductor above ground complete all as specified and direcetd |
| 3 | Supply and fix copper iron strip 32x6 buried in ground as ring main conductor including porcelein insulated clamps complete all as specified and as directed |
| 4 | Supply andfix test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex head screw complete all as specified and directed. |
| 5 | Material and labour for earthing complete with copper earth plate electrode 60cmx60cmx3.15mm buried directly in ground vertically to a depth not less than 2.25mtr deep below ground level with top edge of earth plate at a depth not less than 1.5m below normal ground level connected to copper earth strip of size 20x3 mm by means of bolts, check nuts and washersof brass and protected by GI pipe 40mm bore light & connected to machineryand including concrete pit in PCC (1:3:6) type C1precast RCC (1:2:4) type B-1 cover slab 30cmx30cmx 5c with 10mm dia TMT bar 8 cm C/c both ways and one handle for lifting mae out 8mm dia TMT bar ,funnel, wire mesh 20mm bore galvanised iron pipe (medium grade) for watering ,charcoal ,salt and bentonite powder in alternative layers necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in electrical plate No -3 of SSR part-I complete all as specified and directed by Engr-in-Charge. |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 7 | M&L for 25mm thick PCC 1:2:4 type B-0 (12.5 mm graded aggregate) as in levelling coarse of tile flooring etc complete all as specified and as directed. |
| 8 | M&LGlazed ceramiccolour tiles of size 450 x 300 x 7mm thick (premium/special quality) in vertical wall etc set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cementmortar 1:4 complete all as specified and directed. |
| 9 | Demolition ofstone slabs and granitelaid, bedded and pointed in any mortar of any description or thickness in floors, aprons cills or plateform etc all as specified and directed. |
| 10 | M &for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 11 | M&L for rounding to edges of stone slabs one edge, such as in steps cooking plateform, and other similar situation. |
| 12 | M& L for Machine cut kota stone slabflooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 20 mm thick screed bed in CM 1:3 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed. |
| 13 | M& L for Kota stone slab 20-25 mm thickin riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 10 mm thick baking course in CM 1:4 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed. |
| 14 | M&L for 4mm thick Non asbestos fibre cement building boards and fixed to or laid/ inserted to timber / GI / Aluminium framework with nails as in ceiling flat or slopping ,including dismantling wall and ceilling boards of any description including cover filletscomplete all as specified and directed. |
| 15 | Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section of unframed work complete all as specified and as directed. |
| 16 | S&F for Anodised aluminium snap grid frame work of size 605 x 605 mm for false ceiling all as specified complete all as specified and as directed. |
| 17 | S&F for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specifiedcomplete all as specified and as directed. |
| 18 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including ashlar facings, dressed stonework,precast concrete articles and precast concrete block walling complete all as specified and directed. |
| 19 | M&L for Precast cement concrete block (1:3:6) type C1 (using 20mm graded agg) solid block masonry exc 10cm in width or girth and setting in CM (1:6) complete all as specified and directed. |
| 20 | Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land all specified and directed. |
| 21 | M&L for rendering10 mm thick onconcrete surface in cement mortar (1:6)as backingcoatand 5 mm th in CM 1:4 using finishing the surface even and smoothwithout using extra cement, including mixing only liquid water proofing compound as per manufacturer instruction completeall as specified and as directed on External surface. Note:- WPC will be measured & Paid separately |
| 22 | M&L for 10mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and as directed. |
| 23 | Supply only for water proofing compound. |
| 24 | M&L for complete removal of existing treatment from walls for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over complete all as specified and directed |
| 25 | M&L for preparation of new plaster external surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm overcomplete all as specified and directed. |
| 26 | Complete removal existing treatment and applying two coats of White wash complete all as specified and as directed. |
| 27 | Complete removal existing treatment and applying1mm thick ofBirla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified and as directed. |
| 28 | M & L for preparation of new plastered/concrete surfaces of walls, providing 1 mm thick ofBirla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified. |
| 29 | Demolition of plain cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 30 | M&L for Hard core, broken stone /bouldersto gauge n exc 63 mm size , deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 31 | M & L for 75mm thick cement concrete type C-2 1:3:6 using 40mm graded aggregate as inplinth protection / Path and finished even and smooth without using extra cement. complete all as specified and as directed by the Engineer-in-Charge. |
| 32 | M&L for PCC 1:3:6 type C2 (using 40mm graded aggregate) as in surface channels and drainscomplete all as specified and as directed. |
| 33 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete. |
| 34 | M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set jointed andpointed in neat cement slurry in floor with grey cement and pigment over 15mm thick screed bed in cement mortar 1:4 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed. |
| 35 | Demolition of plain cement concrete (unreinforced) Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 36 | M&L for PCC 1:3:6 type C2 (using 40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and as directed. |
| 37 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 38 | M&L for Preparation of new or previously untreated steelsurfaces of any description, over 10 cm width or girth, not otherwise described, and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete |
| 39 | S & F 1000 litres capacity double layer, rotational molded, polythene (white colour), tripple layer water storage tank, ISI Marked (Cylindrical vertical with closed top),colour white ,hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including dismantling completeall as specified and as directed. |
| 40 | S&F in repair for 20mm dia Ball cock valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20 m m - 210 g m s ) complete all as specified and directed. Make: Prayag or Equivalant. |
| 41 | Taking up or down steel tubing and disconnection, for 15mm bore of pipes including cleaning for refixing or removal to store complete. |
| 42 | Supply and Laying Steel Water Tubing 15mm dia (Bore), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed. |
| 43 | Taking up or down steel tubing and disconnection, for 20mm bore of pipesincluding cleaning for refixing or removal to store complete. |
| 44 | Supply and fix 20 mm bore galvanised steel water tubing, medium grade including necessary fittingssuch as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line including concealed in wall all asspecified. |
| 45 | M&L for Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., in stone concrete block or slab walls and making good, cutting not exc 10 cm girth complete. |
| 46 | S&F in repair 15mm bore stop cock cast copper alloy, fancy type, chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed. . |
| 47 | S&F in repair brass chromium plated tubular towel rail D type, 600mm long between the flanges and 20mm dia complete all as specified and directed. |
| 48 | S&F in repairs Vitreous china WHB, white, flat back, of size 550 x 400 mm including cutting for and pinning in ends of brackets or erecting stand brass, chromium plated waste coupling of 32mm incl pedastalwith 32mm High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in wall complete all as specified and directed. |
| 49 | S&F in repair pillar tap 15 mm, chromium plated, fancy type with screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" withlong screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed Make : Sona & Prayag or equalent |
| 50 | S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed. |
| 51 | S&F in repair PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed. |
| 52 | S&F in repair PVC (SWR) vent cowl 110mm dia complete all as specified and directed. |
| 53 | S&F in repairs PVC (SWR) bend with access door of110mm bore complete all as specified. |
| 54 | S&F in repairs PVC (SWR) bend with access door of 75mm bore complete all as specified. |
| 55 | M&L 75mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement and as approved by the Engr-in-charge. |
| 56 | Taking down chowkat or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters (without taking off shutters from the frame) complete all as speicfied. |
| 57 | Taking down chowkats or frames n. exc 1.50 Sqmeach with shutters (without taking off shutter from the frames) complete all as speicfied. |
| 58 | Resecuring or easing & adjusting without taking down the shutter of any description exc 1 Sqm and n.exc 2 Sqm in same opening complete all as specified and directed. |
| 59 | S&F MS flat iron Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains;hand made sliding bolts; clamps; hold fasts; wall ties; hooks forhanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 all as specified and as directed by Engineer-In-Charge. |
| 60 | M&L for PCC (1:2:4)type B1 (20mm graded Aggregate) in roof kerbs or mud stops, rounded or chamfered on edges and fixing of hold fast complete all as specified. |
| 61 | Supply and fixing2nd class HW plain solid straight chowkhats/frame wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 62 | Supply and fixing 2nd class HW 35mm thickGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares(without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed. |
| 63 | Supply and fixing2nd class HW 35mm thick plain framed panelled shutters (any number of panels), with panel of timber flats on both sides or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified and as directed. |
| 64 | S&F powder coated (min powder coating 50 micron) anodised aluminium frame for doors, windows , ventilators plain or sliding type with one or more rebates including joining cleat for fixing etc complete all as specified and as directed |
| 65 | S&F Powder coated(powder coating min 50 micron)Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. |
| 66 | S&F powder coated(powder coating min 50 micron)anodised window and ventilator shutters side hung/sliding type without sash , aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150 mm long(1 no) hinges type B-21 100 mm long (2 no) suitable handle (1 no ) complete as specified |
| 67 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 68 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applyingtwo coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 69 | Supply and fixing 100mm size butt hinges cold rolled medium weight, ISI marked complete all as specified and directed. |
| 70 | Supply and fixing200mm size MS barrel tower bolt stone enamelled black with bright bolt ISI marked complete all as specified and directed. |
| 71 | Supply and fixing 150mm size MS pressed handle oval type stove enameled block complete all as specified and directed. |
| 72 | Supply and fixing 250mm long MS sliding door bolt, plate type, stove enameled black with bright bolt not less than 12mm dia with and including a min of 6 bolts & nuts four on bolt & two on staple,ISI marked, complete all as specified and directed. |
| 73 | S & F floor door stopper Overall length of cover plate is 140mm longof aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor |
| 74 | S & F 300mm long mildsteelordinary rat tailrod pattern springs including roller and roller plate complete all a specified. |
| 75 | S & FGalvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staplescomlete all as specified and as directed. |
| 76 | M&L for 4.80 mm thick Sheet glass, ordinary quality and glazing with oil putty in fixed to aluminium frame exc 0.50 sqm complete all as specified and as directed. |
| 77 | M&L for 4.80 mm thick frosted Sheet glass, ordinary quality and glazing with oil putty in fixed to aluminium frame exc 0.50 sqm complete all as specified and as directed. |
| 78 | S&F in repair fancy type Anodised aluminium alloy curtain rod 25mm dia including PVC rings @ 100mm c/c with suitable brackets matching to curtain rod of make as as approved by GE complete all as specified and as directed. (Additional supporting bracket shall be provided if length is exceeding 1.2m and rate quoted shall include for the same) |
| 79 | Forming jambs, etc.to openings in CM 1:6 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete |
| 80 | S&F 2nd class HW boarding 20mm thick fixed with nails as in eaves board planed one side with butt joint including dismantling boarding of any description complete all as specified and as directed. |
| 81 | Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified. |
| 82 | Material and labour forPoint wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked,including 20 mm diaPVC conduiton wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild galvanised sunken box/metal flush box made out of 1.6 mm thick galvanised sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally includingaccessories including cutting chases and making goodthe disturbed surfaces as per existingfor one light point controlled by one switch complete all asspecified anddirected by Engr-in-charge. |
| 83 | All as per item No.2 above but One 3 pin 5 Amps socket out let points on independent board |
| 84 | Material and labour point wiring for power point controlled by one, one wayswitch using2.5 sqmm nominal cross sectional areamultistrandedcopper conductor ,PVC insulated unsheathedFRLSH cables in and including 20 mm dia size PVC conduit and fittings of medium grade fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSHPVC insulated unsheathed earth wire and connecting to earth dolly andbrass screws, washers etc. including cutting chases and make good surface complete all as specified and directed. |
| 85 | Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roofceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified and as directed by Engr-in-charge. |
| 86 | Supply and fixing submain wiring for DBs/ Power Point,two single core ,2.5 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including suitable sizePVC conduit (ISI marked) including 2.5 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earthwirecomplete all as specified. |
| 87 | Supply and fixing submain wiring for DBs/ Power Point,two single core ,4 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including suitable sizePVC casing caping (ISI marked) including 4 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earthwirecomplete all as specified. |
| 88 | Supply and fixing submain wiring for DBs/ Power Point,two single core ,6 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including suitable sizePVC casing caping (ISI marked) including 6 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earthwirecomplete all as specified. |
| 89 | Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified. |
| 90 | Supply and fix switch socket combination 2 in 1 multipurpose5 pin , (6 Amps ) flush typecontrolled by one switch complete all as specified. |
| 91 | Supply and fix switch socket combination5 in 1 , 6 pin , (5/16 Amps ) flush typecontrolled by one switch complete all as specified. |
| 92 | Supply and fix in repair Bldg security light fittings 35 watts, minimumm system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed. |
| 93 | S & F Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300msweep with, blades, and frame and louvers complete all as specified and as directed including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall complete all as specified and directed by Engr-in-Charge. |
| 94 | Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contactcomplete all as directed. |
| 95 | Supply and fixMCB SP,6 to 32 Amps, \"C\" series 10kA, 240 Voltsand to be housed in DBs including necessary connection complete all as specified and directed. |
| 96 | Supply and fix MCB SPN 40 - 63 Amps,\"C\" series 10kA, 240 Volts and to be housed in DBscomplete including necessary connectionall as specified and directed. |
| 97 | Excavation in trenches not exceeding 1.5m but n.exc 3.00mtrwide and exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/loose all complete as specified and as directed. |
| 98 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed. |
| 99 | Supply and fixing/laying40mm bore, steel tubings,galvanised, light grade with all fitting laid across road , in trenches or across PCC drain oralong electric pole or floor/wall etcfor protection of cable complete all as specified and as directed. |
| 100 | Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete as specified and as directed. Note :- Only punned down sand shall be measured. |
| 101 | M&L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete. |
| 102 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core Iincluding laying in trench or fixed on wall through clamps complete all as specified and as directed by Engr-in-Charge. |
| 103 | Material and labour in repair for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI \"lightgrade\" pipe from upper end of earth plate upto equipments,20 dia bore GI pipe \"light grade\" as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. |
| 104 | Excavating over areas not exc 1.50m deep and getting out in hard/dense soil |
| 105 | Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed. |
| 106 | M & L forPCC1:3:6 , Type C2 (40mm gradd stone aggregate) as in fixing of in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases)or similar type of works etccomplete all as specified and directed by Eng-in-charge. |
| 107 | S & F for Steel work in tubular trusses with support posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 of Fe 410-W (GdeE- 250) quality A complete all as specified and as directed. |
| 108 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed. complete all as specified. |
| 109 | S&F pre-painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tenssile strength of 550 Mpa as in roof covering / cladding including fixing with self driving machine made screws with washers andfitting of same manufacture of approved profile, complete all as specified and directed by Engr-in-Charge. |
| 110 | S&F pre-painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tenssile strength of 550 Mpa as in roof coveringincluding fixing with self driving machine made screws with washers andfitting of same manufacture of approved profile, shape and colour complete all as specified and directed by Engr-in-Charge. |
| 111 | M & L for 100mm thick cement concrete type D-2 1:4:8 using 40mm graded aggregate as in sub base to floor finished rough to receive finishes. complete all as specified and as directed by the Engineer-in-Charge |
| 112 | M&L for rendering15 mm thick onconcrete surface in cement mortar (1:6) using finishing the surface even and smoothwithout using extra cement, completeall as specified and as directed. |
| 113 | M & Lfor preparation of new surfaces and applying two coat of white wash on the surfaces of walls completeall as specified and directed by Engr-in-Charge. |
| 114 | Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed by Engr-in-Charge. |
| 115 | Excavating in trenches in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out. |
| 116 | Returning, filling in including spreading, levelling, watering & well ramming in layers n.exc 25cm of hard/dense soil complete all as specified and as directed. |
| 117 | Removing the excavation material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point in soil and rock complete all as specified. |
| 118 | M & L for 75mm thick cement concrete type C-2 1:3:6 using 40mm graded aggregate as in sub base to floor finished rough to receive finishes. complete all as specified and as directed by the Engineer-in-Charge |
| 119 | M&L for external plastering 5mm thick in CM 1:4 over 10 mm thick in cm 1:6 on fair faces of brick or concrete, surfaces finished even and smooth without using extra cement. |
| 120 | M&L for 3 coats of white wash including preparation of new surfaces on walls complete all as specified. |
| 121 | S&F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment and confirming to Fe 410 -W (Gde-E- 250) quality- A complete all as specified and directed by Engr-in-Charge. |
| 122 | S&F pre-painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tenssile strength of 550 Mpa as in roof covering / cladding including fixing with self driving machine made screws with washers andfitting of same manufacture of approved profile, complete all as specified and directed by Engr-in-Charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy