|
| 1 | Dismantlingfloor,hearth or wall tilingincluding cement mortar bedding ( includingbacking) removing from siteand rubbish off premises |
| 2 | M&L fornon-skid ceramic colour tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc over and including 15 mm thick screed bed in cement mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade / colour / matrix of the tiles complete. |
| 3 | M&L for vitrified ceramic tile light shade 8 to 10mm thick light shade (square / rectangular) polished, area of each tile not exceeding 0.36 sqm, over 15 mm thick screed bed in cement mortar 1:4 in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete all as specified and directed. |
| 4 | M&L for glazed ceramiccoloured tiles in vertical surface such as skirting/dado etc, of size 350x250x7mm thick or 450x350x7 mm thick over and including 10 mm thick bedding layer in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or colour cement to match with the shade/colour/matrix of the tiles. |
| 5 | Demolition of cement concrete (unreinforced) in ground floors and paving n.exc 15 cm thickness (below or above ground level) including stone slab of any thickness complete all as specified and directed. |
| 6 | M&L for PCC (1:3:6) Type C2 (using 40 mm graded stone aggregate) , 75mm thick finished even & smooth without using extra cement as in plinth protection including bitumen/mast filling in the joint complete |
| 7 | M&L for 40 mm thick cement concrete in 1:2:4 type B-1, using 20 mm graded stone aggregateas insub basefinished even and fair complete all as specified and directed. |
| 8 | M&L for cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base, leveling course or filling in foundation in massconcretecomplete all as specified and directed. |
| 9 | M&L for 20 -25 mm thick kota stone, machin cut kota stone slab flooringover 20mm cement screed bed in cement mortar (1:6), andjointed in neat cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed. |
| 10 | M&L for 20 -25 mm thick kota stone, machin cut kota stone slab as in skirting, dado or in vertical surface including 15 mm thickcement mrtar in(1:4)andjointed in neat cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.. |
| 11 | Taking down loose/damanged/breakage concrete of any description from reinforced cement concrete of columns, beams ,slab , bracing , chajjas, fins, facia, and wall etc upto height of 10 mtr from ground levelby hammering with wooden malate carefully without damaging existing serviceable structure, chipping old concrete for receiving concrete, plastering etcand disposal of debris in low laying area of def land complete all as specified and directed. |
| 12 | S&F ofhard drawn steel wire fabric weight not exc 4 kgs/sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia, fixed with existing reinforcement work upto height of 10mtr from ground level complete all as spd and directed(Make :- (a) Tiger brand wire netting, Varada, manufacturing Co, 5118 Bazar Sirkiwala, Delhi-6, India Landmark near chawri Bazar metro station. (b) Suregreen Ltd delhi. |
| 13 | M&L for guniting with cement coarse sand 1:3 with and including FOSROC Nitobond SBR or equivalant company mixed @ 1 ltr per 50 kgs of cementand water cement ratio 0.45used as per manufacturer\"s instruction using shotcrete pumps and allied equipment, uniform thickness of 30mm to 50mm including 12 mm thick plaster in cement mortar(1:4) uniform and smooth finished upto height of 10 mtr from ground level complete all as spd and directed by EIC (Note :- Before execution of guniting work all the machinary and plants like electric panel, elect motor and its accessories installed in the buildingto be covered properly with gunny bags or polyethylene sheets to avoid damage of the same) |
| 14 | Demolition of reinforceme concrete work as in roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work. |
| 15 | Demolition of reinforceme concrete work of any descriptionand any position ontother wise specifically provided for complete all as spd and directed. |
| 16 | Demolition of brickwork of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles. |
| 17 | Excavation in trenches in soil n.exc 1.5 m wideand n.exc 1.50m in depth for foundation, pier holes etc; n.exc 10 sqm on plan and getting out removing surplus soil to a distance n.exc 50m and making good surface. |
| 18 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm in soft/loose soil al as specified and directed. |
| 19 | M&L cement concrete 1:4:8 type D-2 using 40mm graded aggregate in foundation, filling and mass concrete complete. |
| 20 | M&L reinforced cement concrete (nominal mix) 1:2:4 using 20 mm graded aggregate in foundation, footing, foundation beams, plinth beams, bases for columns,pedestal, under reamed piles, mass concrete, etc complete. |
| 21 | M&L reinforced cement concrete (nominal mix) 1:2:4 using 20mm grared aggregate as in columns, pillars, posts, struts etc complete. |
| 22 | M&L reinforced cement concrete (nominal mix) 1:2:4 using 20mm grared aggregate as in coping, beams, cantilevers, bressummers, lintels over 1.5 m span etc complete. |
| 23 | M&L reinforced cement concrete (nominal mix) 1:2:4 using 20mm grared aggregate as in slab supported on wall, beam or columns roof landing etc using 20mm graded stone aggregates complete all as specified & directed. |
| 24 | M&L reinforced cement concrete (nominal mix) 1:2:4 using 20mm grared aggregate ass in chajjausing 20mm graded stone aggregates complete all as specified & directed. |
| 25 | Form work to sides of concrete surface rough finished flat infoundations, footings, sides and sofits (if any) of foundations & plinths beams and similar worketc complete all as specified and directred. |
| 26 | Form work to side of concrete surface rough finished square, rectangular or polygonal as in columns, pillars, posts, struts, and similar workcomplete all as specified and directed. |
| 27 | Form work to sides and soffits of lintel and roofbeams rough finished surfaces of concrete complete all as specified & directed. |
| 28 | Form work to rough finished flat surfaces as insoffits of suspended slabs such as roof slabs, landing and similar work not exceeding 200mm thick (Horizontal or sloping) complete. |
| 29 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, coping, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for fair finished surfaces. |
| 30 | M&L mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cracking, bending, spirally for hopping for columns hookings ends and binding with and incl mild steel wire (annealed) not less the 0.9mm dia or securing with clips complete. |
| 31 | - ditto - all as per above item No.30 but 5mm dia and over upto 10mm diain stirrups, spacers and binders complete. |
| 32 | M&L forbrick work with sub class \"B\" bricks (old size) straight or curved on plan exc 6 m mean radius, built in cement mortar(1:4) complete all as specified and directed. |
| 33 | Dismantling structural steel work including doors, gates purline, post , grills guard bar etc but excluding framed truss etc. |
| 34 | S&F of steel rolling shutters, thickness of latch 1.25 mm thick withoutball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type, erected in position complete all as directed and as specified . |
| 35 | S&F of ball bearing for rolling shuttrs complete all as specified and directed. |
| 36 | Taking down door / window frame with shutter (without taking of shutter from the frame ) area n.exc 1.5 sqm. |
| 37 | S&F of steel window with side hung shutters including projecting or box stype hinges with steel handle peg stay and divided into square with glazing bars dovetailed or welded, to receive glazing, or gauzing including one coat of primer including fixing of hold fast of size 25 x 5 mm flat iron etc all complete. |
| 38 | S&F for 3.0mm thick sheet glass, ordinary quality and glazing with oil putty in squares n.exc 0.5sqm in each pane complete all as specified and directed. |
| 39 | Dismantling of plain or corrugated steel sheeting any gauge or thicknessin roof coverings or wall cladding of any pattern and size complete all as specified and directed. |
| 40 | M&L for pre- painted galvatume aluminum zinc coating AZ-150 GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 41 | M&L for pre- painted galvatume aluminum zinc coating AZ-150 GI based plain steel 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 42 | Excavating in post holes (or similar holes) ineach n.ex 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm watering and removing surplus soil to a distance n.exc 50m and making good surface. |
| 43 | M&L in cement concrete type C-2 1:3:6 (40mm graded aggregate)as in post hole, foundationfilling in mass concrete complete all as specified and directed. |
| 44 | S&F of steel work in tubular or angle iron trusses including special shaped washer etc; complete using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240 |
| 45 | S&F of Fe-290 (Gde-E-165) rolled mild steel angle inroof trusses, posts etc, purlins, crane gantries rails etc. |
| 46 | M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide (1st grade quality) complete all as specified and as directed. |
| 47 | Taking down cement plaster, any description from brick or stone walls etc; including racking out joints, hacking for key, scrubbing down with water, incl taking down roots of trees complete all as specified and directed. |
| 48 | M&L for rendering 10 mm thick on brick or concrete surfaces in cement mortar(1:6), finished even & smooth without using extra cement complete all as specified and directed. |
| 49 | M&L for applying two coat of oil bound distemper over one coat of primer on new surfaces including sand papering the puttied surfaces to form an even and smooth surface, using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturerand accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed.Note :-The work pertaining to periodical services shall be executed by authorized applicator of manufacturer of Paints proposed to be used by the contractor and approved by AGE (I) (U) B/R |
| 50 | M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work on concrete surfaces using water proofing compound @ 3% by weight of cement/200 ml per 50 kg cement as per manufacturer instractionfinished even and smooth without using extra cement complete all as specified and as directed. (Note : WPC to be paid separately) |
| 51 | Supply only integral water proofing compound ISI marked. |
| 52 | M&L for applyingtwo coats of weather proof exterior emulsion paint over priming coat of exterior primer on new or untreated plastered surfacesusing Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure complete all as specified and directed. |
| 53 | M&L for rendering 5 mm thick in cement mortar (1:3) on ceilling finish even and smooth with out using extra cement complete all as specified and directed. |
| 54 | M&L for prepration of newly plastered surfaces on ceiling and applying three coats white wash complete all as specified and directed. |
| 55 | M&L forapplying one coat white washon old decorated ceiling surface including preparation of old surfaces& filling cracks and holeswith white cementorcementmorter (1:2) complete all as specified and directed. |
| 56 | T&P for complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc; by skilled labour complete all as directed. |
| 57 | M&L for applying two coats of white cement based putty including sand papering the puttied surfaces to form an even and smooth surface complete all as specified and as directed. |
| 58 | M&L for applying two coat of oil bound distemper over one coat of primer on new surfaces including sand papering the puttied surfaces to form an even and smooth surface, using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturerand accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed.Note :-The work pertaining to periodical services shall be executed by authorized applicator of manufacturer of paints proposed to be used by the contractor and approved by AGE (I) (U) B/R |
| 59 | Taking up or down steel tubing and connection of 20 mm bore complete all as directed. |
| 60 | S&F of GI tubing 20 mm bore medium grade with all fittings and fixed to wall. |
| 61 | Taking up or down steel tubing and connection of 15 mm bore. |
| 62 | S&F of GI tubing 15 mm bore medium grade with all fittings and fixed to wall. |
| 63 | M&L for cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc; and cutting chases for concealed water tubing or concealed conduit wiring etc; and making good, cutting n.exc 10 cm girth complete all as directed. |
| 64 | S&F in repairs of bib tap 15 mm dia fancy type chromium plated cast copper alloy with crutch or butter fly handle screwd for iron pipe or for brass ferrule and fixed. |
| 65 | S&F in repairs of stop valve /angle cock 15 mm dia chromium plated fancy type cast copper alloy high pressure with crutch or butter fly handle screwd for iron pipe or union and fixed. |
| 66 | S&F in repairs pillar tap 15mm dia, fancy type cast copper alloy, with capstan heads, chromium plated screwed down high pressure with or without lettered \"Hot\" or \"Cold\" with long screwed shank and fly nuts, screwed for iron pipe and fixed. |
| 67 | S&F in repairsforvitreous china squatting pan orrisa pattern 580mmx440mm with integrated foot rest, S or P trap including cement concrete bedding complete all as specified and as directed. |
| 68 | S&F in repairs PVC valve less syphonic action type low level flushing cistern 10 ltr, white with inlet ball valve float and handle including bracket with flush pipe of polythene of low or high density 32 mm PVC. |
| 69 | Taking down SWR pipe(any size and pattern including all fittings heads shoes bends etc; complete all as specified and directed. |
| 70 | S&F of PVC (SWR)110 mm bore Pipes single socketed ,in any length with rubber ring joints fixed to walls. |
| 71 | S&F of PVC (SWR)110mm bends any radius. |
| 72 | S&F in repairs Vitrous china wash basin, white, flat back, size 630x450mm excluding taps, incl.waste coupling brackets and flaxible waste pipe complete all as spd and directed. |
| 73 | S&F in repair PVC moulded 600x450mm bevelled edges mirror of selected quality glass, mounted on 6mm thick PVC board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 74 | S&F in repairs PVC connection 15 mm dia, 450 mm long including brass fly nuts at both ends etc.complete |
| 75 | Dismantlingwater tank of capacity n.exc 500 ltr and removing off site complete all as specified and as directed. |
| 76 | Dismantlingwater tank of capacity exc 500 ltr but n.exc 1000 ltrs and removing off site complete all as specified and directed. |
| 77 | S&F of rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 ltr hoisted and fixed in position incl 20 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwd for iron pipe and fixed all as specified in SSR Part I |
| 78 | S&F of rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 ltr hoisted and fixed in position inclincl 20 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwd for iron pipe and fixed all as specified in SSR Part I |
| 79 | S&Fof gun metal gate valves 20 mm diawith iron wheel head ,screwed both ends for iron pipe and fixed complete all as specified and directed. |