| 1 | Surface dressing not exc. 150mm deep and getting out in Soft/Loose Soil, complete all as specified and as directed. |
| 2 | Surface Excavation not exc. 30 Cm deep and ave. 15 Cm deep and getting out in Soft/Loose Soil, complete all as specified and as directed. |
| 3 | Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, etc. complete all as specified and as directed. |
| 4 | Returning, fillingincluding spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soilcomplete all as specified and as directed. |
| 5 | Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 6 | Dismantling Reinforced Cement Concrete of any description and in any Position not otherwise specifically provided for, complete all as specified and as directed. |
| 7 | Demolition of Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed. |
| 8 | M&L Cement concrete type D-2 1:4:8 using 40mm graded stone aggregate in filling foundations and mass concrete complete all as specified and as directed. |
| 9 | M&L Cement Concrete 1:3:6 (40mm graded crushed stone aggregate) 75mm thick as in Path / Paving etc. laid in alternate Bays, finished Concrete Surfaces Even and Smooth without using Extra Cement complete all as specified and as directed. |
| 10 | M&L Reinforced Cement Concrete (Design Mix) M-25 in Foundations including Rafts, Footings, Foundation Beams; Plinth Beams; bases for Columns, etc.; Basement Slabs, Under-reamed Piles and Mass Concrete, complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 11 | M&L Reinforced Cement Concrete (Design Mix) M-25 in Columns, Pillars, Piers, Posts and Struts, etc. complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 12 | M&L Reinforced Cement Concrete (Design Mix) M-25 in Roof Beams, Cantilevers, Bres-summers, Lintels over 1.50 Metre Span, complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 13 | M&L for RCC M-25 (Design Mix) as in roof slab supported on wall, beam, landing, desk slab etc complete all as specified and directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 14 | M&L for providing cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate in coping/DPC water trough and and like including weathring, slightly rounded or chamfered angles and throating as directed including form work complete all as specified and directed. |
| 15 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 16 | M&L TMT Bars 8 mm dia , cut to length, bent to shape required including crank-ing, bending and bindingwith and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed. |
| 17 | M&L TMT Bars 8 mm dia , cut to length, bent to shape required including crank-ing, bending and bindingwith and including Mild Steel Wire (annealed) not less than 0.90 mm, as in stirrups spacers and binders complete all as specified and as directed. |
| 18 | M&L Formwork to Sides of Concrete Founda-tions, Footings, bases of Columns, Raft and Raft Beams, Sides and Soffits (if any) of foundation and plinth beams and similar work; Square, rectangular or polygonal, vertical or to batter, flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 19 | M&L Formwork to Sides and Soffits of Floor or Roof Beams, Beam Haunchings, Girders, Bres-Summers, Lintels, Cantilevers, Shelves including supports, overhangs, etc. also splays between floors and beams, etc., flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 20 | M&L Formwork to sides of Pillars, Posts, Struts, Piers, Columns and stanchions, flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 21 | M&L Formwork toSoffits of suspend slab such as Roof slab, Floor slab, landings and similar works horizontal or sloping etc., not exceding 200mm thick ,flat rough finished surfaces of concrete, complete all as specified and as directed. |
| 22 | Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed. |
| 23 | M&LOld size sub Class B bricks, straight or curved on plan exc 6 m mean radius built in cement mortar ( 1:4) having compressive strenght notless than 75 kg/Sq cm complete all as specified and as directed. |
| 24 | Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed. |
| 25 | M&L Rendering15mm thick in Cement Mortar 1:4 on n fair faces of Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and Smooth without using Extra Cement complete all as specified and as directed. |
| 26 | M&L Rendering15mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and fair without using Extra Cement complete all as specified and as directed. |
| 27 | Supply only Integral Water Proofing compound, conforming to IS 2645 and as approved, complete all as specified and directed. |
| 28 | M&L Preparing new Surfaces of Walls and applying Three Coats of White Wash, complete all as specified and as directed. |
| 29 | M&L Preparing new plastered surfaces of Walls and applying Two Coats of Exterior Emulsionanti fungus Paint over a coat of damp shield Primer (as per Manufacturer’s instructions) complete all as specified and directed. |
| 30 | M&L 20mm to 25 mm thick Chequered cement concrete tiles of size 305mmx305mm, as in floor,top surface treated with antifungal paint,set jointed and pointed in neat cement slurry with pigments over 15mm thick screed bed (1:6) in cement morter complete all as specified and as directed. |
| 31 | M&L 75mm thick plain cement concrete (1:3:6) type C1 using 20mm graded stone aggregate as in plinth protection/Path and finishing surfaces of concrete even and smooth without using extra cement and laidin alternate ways including filler joints with sealing compound grade A as where required complete all as specified and as directed. |
| 32 | M & L for 100 mm PCC 1:2:4 ( 20 m graded stone aggregate) as in floor,paving inclidingfinished even and smooth without using extra cement complete all as specified and as directed. |
| 33 | M&L Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ Thickness of concrete slab in 100 mm complete all as specified and as directed. |
| 34 | M&L for Hardcore ofbroken stone or boulders guage n exe. 63mm deposited spread and levelled in layersn exe 15 CM thick watered and rammed to a true surface complete all as specified and as directed. |
| 35 | M&L Moorum/red bajri filling in floors or pavings , laid in lyers 30 cm in thick spread , levelled and rammed including watering complete all as specifiedand directed by Engr-in-charge. |
| 36 | S&F PVC (SWR) Soil, Waste and Ventilating Pipe 110mm bore (dia), single socketed, in any length with Rubber Ring Joints fixed to Walls, complete all as specified and as directed. |
| 37 | S&F 35mm thick precast cement concrete Type (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) louvers and jallies including all moulding, but excluding frameset in cement morter 1:4 complete all as specified and as directed. |
| 38 | Supply and fixing in replacement of cable endjointing kit ,1100 volt grade (earthed) , 300 sqmm 3.5 core , aluminium conductor XLPE insulated armoured heavy duty cable heat shinkable suitable in/ out door type to be fix on incoming /outgoing connection of LT panel with gland etc at various location complete all as specified and directed. |
| 39 | Supply and fixing in replacement of cable endjointing kit ,1100 volt grade (earthed) , 50 to 120 sqmm 3.5 core , aluminium conductor XLPE insulated armoured heavy duty cable heat shinkable suitable in/ out door type to be fix on incoming /outgoing connection of LT panel with gland etc at various location complete all as specified and directed. |
| 40 | Supply and fixing in replacement of cable endjointing kit ,1100 volt grade (earthed) , 16 to 25 sqmm 3.5 /4.0core , aluminium conductor XLPE insulated armoured heavy duty cable heat shinkable suitable in/ out door type to be fix on incoming /outgoing connection of LT panel with gland etc at various location complete all as specified and directed. |
| 41 | S&F Sintex fibre body loopin/ loopout enclosure of size160mm x 200 mm x 98 mm, IP- 66 consisting of 4 No. aluminium busbar of size 120 mm x 20 mm x 2 mm thick fixed on porcelin support inside enclosure with pole using 40 x 6 mm size MS FI clamps of required shape with bolts, nuts & washers complete all as specified and directed. |
| 42 | Supply, install, testing & commissioning of LTbusbar chamber of size (0.60x0.60x0.60)m Factory made, outdoor type, factory made fabircated to CRCA sheet of 3.15mm thickness,MS angle iron 40x40x6mm size 0.9mtr long suitablegrouted in ground with PCC 1:3:6 type C2, frame work and tee section (frame) of suitable sizedouble door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and makingcomplete including PCC foundationcomprising of followingaccessories:- BUS-BAR & INTERNAL CONNECTIONS:MCCB 200 amps, 4 pole,415 Volt Adjustable type with breaking capacity 25 KA, and 100 % Icu fitted with bus-bars shall be made up of 04 Nos Aluminium 400 A rated not less than 40 mm x 10 mm, duly insulated with 1100 V grade standard colour coded PVC sleeves PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables.INSTRUMENTATION SYSTEM :(a)Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set.(b)3 Ph Digital Voltmeter CI 1.0 - 01 No (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 01 Nos.NOTE : 1) Design / Drawing / BOM of the LT Busbar panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 43 | Supply and layingin replacementof XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 300 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed by the Engr-in-Charge. |
| 44 | All as in Item No 43 but for 120 Sqmm x 3.5 core |
| 45 | All as in Item No 43 but for 95 Sqmm x 3.5 core |
| 46 | All as in Item No 43 but for 50 Sqmm x 3.5 core |
| 47 | All as in Item No 43 but for 25 Sqmm x 4 core |
| 48 | All as in Item No 43 but for 16 Sqmm x 4 core |
| 49 | All as in Item No 43 but for 10 Sqmm x 4 core |
| 50 | Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge.Note:- Thickness after punning down shall be measured for payment. |
| 51 | Supply and laying in trenches Bricks, sub class \"B\" over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge. |
| 52 | Labour only for horizontal boring under the road below 1 mtr from the road surface and dia of hole not exc 100 mm without damaging the existing road getting out and disposal of soil to a distance not exceeding 50 mfrom the site of work complete all as specified and as directed. |
| 53 | Supply and laying in replacement of galvanised steel tube, light grade bore of dia 80 mm with all fittingsfor protection of cable complete all as specified and as directed. |
| 54 | Supply/ laid/ fixingin replacement of galvanised steel water tube, light grade bore of dia 50 mm with all fittings all as site and directed. |
| 55 | Supply and fix in replacement 3 core 1.5 sqmm multistranded PVC insulated flexible copper cable FRLSH grade includingPVC Conduit of min 25 mm dia to protect the cable complete all as specified and as directed. |
| 56 | M&L for Painting to electric pole steel tubular/ PCC of any length after removing /scraping/ bruses/ cleaning to old painton external surface intwo coats of paint over one coats of red oxide primer by using aluminium paint on steel tubular and cement paint on PCC poles in any height/ length/ dia etcincluding cross arms/ angles, nut, bolt , washers etc and making alternate strips of yellow and black paintin 30 cm minium width upto 1.5 Mtr above normal GL and writing Pole No complete all as site and directed by Engr-in-Charge.Note : Colour of paint shall be approved by Engr-in-charge. |
| 57 | Dismantling of ACSR or AAC condutor from LT servicefeeder or distribution line complete all as specified and directed by Enge-in-Charge. |
| 58 | Dismantling cross armsof MS channels or angle sections etc complete all as specified and directed by Enge-in-Charge. |
| 59 | Dismantling insulators any type any sizes complete all as specifiedand directed by Enge-in-Charge. |
| 60 | M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.5 of SSR Part I and including testing on completion all as specifiedand as directed by the Engineer-in-Charge.Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GIwater pipe including GI protection pipe 40mm dia light grade for earth strip etc.2. The cost of earth pit is deemed to be included in the unit rate. |
| 61 | Supply, install, testing & commissioning of LTPanel Factory made, outdoor type, factory made fabircated to CRCA sheet of 3.15mm thickness,MS angle iron 40x40x6mm size 0.9mtr longframe work and tee section (frame) of suitable sizedouble door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and makingcomplete including PCC foundation 800 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and complete with internal wiring the following items housed indl :-(A)Incoming :- MCCB 4 pole, 400 Amps, breaking capacity 50 kA. microprocessor type - 01 nos Outgoing(B) MCCB 4 pole,250 Amps, breaking capacity 36 kA .microprocessor type - 01 Nos (C)MCCB 4 pole,100 Amps, breaking capacity 25 kA . - 02 Nos (D)MCCB 4 pole,63 Amps, breaking capacity 25 kA . - 01 Nos (E)Three Ph Digital Volt Meter(0-500)Volt with selector switch. - 01Nos(F) Three Ph Digital Ammeter with CT\"s with appropriate Ratio along with selector switch. - 01 Nos(G) Digital frequency meter 40-60 Hz.-01 Nos(H) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set |
| 62 | Supply, install, testing & commissioning of LTPanel Factory made, outdoor type, factory made fabircated to CRCA sheet of 3.15mm thickness,MS angle iron 40x40x6mm size 0.9mtr long suitable , frame work and tee section (frame) of suitable sizedouble door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and makingcomplete including PCC foundation 500 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and complete with internal wiring the following items housed indl :-(A) Incoming :- MCCB 4 pole, 250 Amps, breaking capacity 36 kA.microprocessor type - 01 nos (B) Outgoing : - MCCB 4 pole, 100 Amps, breaking capacity 25 kA . - 02 Nos (C)MCCB 4 pole,63 Amps, breaking capacity 25 kA . - 01 Nos(D)Three Ph Digital Volt Meter(0-500)Volt with selector switch. - 01Nos(E) Three Ph Digital Ammeter with CT\"s with appropriate Ratio along with selector switch. - 01 Nos(F) Digital frequency meter 40-60 Hz.-01 Nos(G) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set |
| 63 | Supply and fixing in replacement of Automatic street light control switch Panel complete with, complete all as specified and directed.a) Infrared sensor based Nature Switch for automatic switching of street lights (Asto. Nature switch operation should be based on Natural light Lux level. Required luminance level for switching ON is less or equal to 30 Lux and for switching OFF 10 Lux. The sensor should also have part night operation facility of minimum 4 hrs to maximum 12 hrs. - 01 No. Make Of Sensor: L&T/SIEMENS/ HPL/Bajaj/ABBb) Power contactor two pole, 230 volts, 63 Amp capacity,confirming to IEC-60947-4-1. - 01 No.Make:- L&T/Schneider/ABB/Bajajc) The sensor along with suitable power contactor and incoming outgoing MCBs should be enclosed in a pole/ wall mountable rust proof, electric shock proof, termite proof and FR grade Thermoplastic polycarbonate enclosure (with hinged lid) confirming to IP66 protection class 2 of suitable size to accommodate all panel accessories. -01 Job.d) MCB SP 63 Amp, C Curve, Confirming to IEC-60898/IS8828. -02 Nos.Make: Hager/Schneider/L&T/ABBe) All control cable wiring inside the panel should be of copper conductor, multistandard, PVC insulated, FRLS, 1100 volts grade, of size 10 sq mm, single core, followed by colour coding and lugs/thimbles.f) All equipments are mounted on suitable size insulators.Make Of Panel as per Manufactures listNote 1:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. Note 2-Contractor\"s supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embossed with contractor\"s firm name while carrying out any activities in defence area for better check of security purpose.Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs) |