| 1 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/ erection of poles, stays, trench etc., complete all as specified and directed. |
| 2 | Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and directed. |
| 3 | Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and directed. |
| 4 | Supply, fixing or layingHDPE (DWC) tubing 40 mm dia as per IS:16205 part 24 fixing on poles, walls under floors, laying on surface etc as reqd at site including clamps to hold pipe at position including taking down old existing complete all as specified and directed. Note: All items and accessories , bend, joints, nut bolts, clamps for wall fixing as per site requirement etc are incl in quoted rates. |
| 5 | Disconnecting & taking out defective underground cableany size and any type from trenches, pole, pipe, floor, wall etc., complete all as specified and directed. Note: Old cable may different size and length and credit will be given as actual obtained from site. |
| 6 | Supply and laying, connecting and testing XLPE underground cableinsulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 35 sqmm 3.5 corelaid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc., complete all as specified and directed. |
| 7 | All as per Item Ser item No 6.00 above but for 4 core 16 Sqmm, complete all as specified and directed. |
| 8 | M&L for replacement of B311100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core10 sqmm cable flat or circular complete all as specified and directed. |
| 9 | S&F in replacement ofPVC insulated flexible FR PVC unarmoured cable three core with copper conductor 1.5 Sqmm size 1100 volt grade complete connection all as specified and directed. |
| 10 | S&F cable jointing kit for 1.1 KV grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 ½ / 4 core, XLPE, armoured, Al conductor cable of size 16 sqmm, complete all as specified and directed. |
| 11 | All as per Srl Item Ser No 10.00 above but for cable of size 25 to 50 sqmm, complete all as specified and directed. |
| 12 | All as per Srl Item Ser No 10.00 above but forstaright through for cable of size 16 sqmm, complete all as specifed and directed. |
| 13 | All as per Srl Item Ser No 10.00 above but for staright through for cable of size 35 sqmm, complete all as specifed and directed. |
| 14 | S&F KIOSK box weather proof made out of PVC including made out of one piece mounted SMC base and door pole mounted hinged door size 300 x 200 x 105mm inside dimension comprising of aluminum bus bar 4 strips for 3 phase and neutral 200 Amp nd 6.0 Amp MCB for controlling the street light fitting with necessary MS nuts bolts and washer, complete all as specifed and directed. |
| 15 | S&F in replacement LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with potted driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specifed and directed. |
| 16 | All as per Srl item No. 15.00 above but for capacity 70/72W, complete all as specifed and directed. |
| 17 | S&F LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with potted driver and lamp, complete all as specified and directed. |
| 18 | S&F in replacement LED flood light 300 watt 230 V AC outdoor type with assembly box of 300/350W and thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete including taking down old halogen flood light fiiting complete all as specifed and directed. |
| 19 | M&L for painting of steel tubular LT poles including removing rusted particles and painting with two coats of synthetic enamel aluminium paint including cross arms,supports, clamps,etc and providing different colour strip upto height 1.5 mtr from from coping including writing pole no complete all as specifed and directed.Note:Colour of paint for stripsand no of stripswill be approved by Engr-in Charge. |
| 20 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts and wasters,clamps,welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide primer and two coats ofaluminum paint incl dismantling and taking down old unserviceable complete all as specified and directed. |
| 21 | S & F in replacement of Automatic street light control with infrared sensor based NATURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) Three phase load of 5 KW for automation of street lights.Nature Switch operation should be based on Natural light Lux level.Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs.VMS should have adjustable over & under Voltage trip level and protection against phase loss, Neutral loss & Phase reverse incl Power contactors (3 nos of capacity 16 amps per phase each) and incoming (3 nos of capacity 20 amps each)- outgoing MCB(3 nos of capacity 20 amps each)& main load circuit wiring (Copper) of minimum 10 sqmm. The sensor , VSM, Power contactor, MCBs incl connected items should be enclosed in a Pole/wall mountable enclosure made of rust proof, electric shock proof,termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e. sensor & VMS By-Pass option) complete all as specified and directed. |
| 22 | S&F in replacement post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete including taking down old unserviceable light fitting complete all as specifed and directed. |
| 23 | S&F in replacement of LED bollard with IP 65 protection and 10/11 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete includingnut bolts, washer complete all as specified and directed. |
| 24 | S&F Joist, channel, angle, or tee sections, fixed independently with welding, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of Fe-410W (Gde E-250) quality-B, against worn out channel, angle iron etc., complete all as specifed and directed. |
| 25 | S&F in replacement 12 watt All in One solar street light luminare (Led light 12 watt, solar panel 60 watt, Li-Po4 battery 12V 12Ah) incl taking down old unser and complete fixing and connection complete all as specifed and directed. |
| 26 | S&F in replacement 12 watt Semi-integrated solar street light luminare (Led light 12 watt, Li-Po4 battery 12V 12Ah) incl taking down old unser and complete fixing and connection complete all as specifed and directed. |
| 27 | S&F in replacement 12V 12 AH lithium ion battery incl taking down old unser and complete fixing and connection complete all as specifed and directed. |
| 28 | S&F in replacement 12 watt led driver for solar street light incl taking down old unser and complete fixing and connection complete all as specifed and directed. |
| 29 | S&F in replacement LED panel for solar street light incl taking down old unser and complete fixing and connection complete all as specifed and directed. |
| 30 | S&F in replacement of unserviceable medium grade GI pipe 80 mm, complete all as specified and directed. |
| 31 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) or road cutting complete all as specified and directed. |
| 32 | M&L for PCC 1:4:8, type D-2, using 40 mm graded crushed stone aggregate as in filling demolished surface or as leveling course or in foundation or under tiles or in any required work and make surface clear, complete all as specified and directed. |
| 33 | S & F in replacement of street light bracket made out of GI pipe note less than 25mm bore light grade suitable for fixing LED street light approx length not less than 1.20 mtr bent to shape, complete all as specified and directed. |
| 34 | M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common saltin alternate layersof 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0mm dia at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through GI pipe for protection of earth lead wireincl PCC earth pit 1:3:6, type C-2 with CI frame andRCC cover all as shown in electrical Plate No 3 on SSR Part-Iincluding testing and dismantling ,taking down old unser earthing, complete all as specifed and directed.Note:(i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, earth lead protection pipe of dia 20 mm, water pipe of dia 20 mm complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate. |
| 35 | All as per Srl item No 34.00 above but for galvanised iron strip 32×6mm as earthing lead, complete all as specifed and directed. |
| 36 | M&L for dismantling the solar water heating system of 1500 ltrs capacity completely by replacing worn out/deteriorated accessories of solar water heater including reassembling, necessary connection and installing/ testing complete all as specifed and directed. Note- Accessories will be measured & paid separately as supply only. |
| 37 | All as per Srl item No 36.00 above but of capacity 500 LPD, complete all as specifed and directed. |
| 38 | M&L for De-scaling, cleaning of hot water tanks including heat collector, pipes etc with suitable agents of solar heating system of capacity 100ltrs complete all as specifed and directed. |
| 39 | Supply only for mixing of anti freezing agent Propylene glycol complete all as specifed and directed. |
| 40 | M&L for toughened sun glass of collector, thickness as per existing suitable size for 100 Ltr capacity solar water heater panel, complete all as specifed and directed. |
| 41 | M&L for hose pipe including thread clamps at both ends of suitable length as required on site suiable upto 32mm bore GI pipe including nut bolts as required on site, complete all as specifed and directed. |
| 42 | M&L for electric heater 3 KW rating, single phase, 240 volts, complete all as specifed and directed. |
| 43 | S&F against replacement of Flat plate solar collector 100ltrs or as per existing size, complete all as specifed and directed. |
| 44 | S&F in repair to flat plate solar collector including brazing of leaked copper tubes complete all as specifed and directed. |
| 45 | S&F in replacement cladding on existing pipe by replacing with insulation Rockwool 2\" thick, aluminium sheet of 26 gauge and steel screws as per existing complete all as specified and directed. |
| 46 | S & F in replacement (makeup) steel tank of 5 ltr capacity for solar water heating system complete all as specifed and directed. |
| 47 | S&F in repair of stainless steel hot water tank of 1500 ltr capacity for solar water heating system against leakage with welding complete all as specified and directed. |
| 48 | All as per Srl item No 47.00 above but of capacity 500 LPD, complete all as specifed and directed. |
| 49 | S&F in replacement air termination single pointed copper rod 12 mm dia and 300 mm long with necessary fixing arrangement on roof incl dismantling and taking down old broken air termination complete all as specified and directed. |
| 50 | S&F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors & fixed to porcelain insulator on wall for down conductor incl dismantling and taking down old unsv strip complete all as specified and directed |
| 51 | Repair and refixing of aluminium strip with saddle complete all as specified and directed. Note: Rate of misc items for refixing deemed to be incl in quoted rates. |
| 52 | Repair and refixing of termination rod complete all as specified and directed.Note: Rate of misc items for refixing deemed to be incl in quoted rates. |