| 1 | S.H. Civil Work : |
| 2 | Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 metres including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres Loose/Soft Soil |
| 3 | Filling in plinth with sandy soil under floors including watering ramming, consolidating and dressing complete. |
| 4 | Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering |
| 5 | a) 1:4:8(1 cement : 4 coarse sand :8 graded stone aggregate 40 mm nominal size) |
| 6 | b)1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up to floor five level excluding cost of centering,shuttering, finishing and reinforcement: 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with : 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 10 | Reinforcement for R.C.C. work i/c bending ,binding and placing complete. Tor Steel |
| 11 | 2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement: 4 coarse sand) |
| 12 | Half brick masonry 2nd class (local 1st class) in cement mortar 1:4(1 cement: 4 coarse sand) in superstructure. |
| 13 | Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide zinc chrome primer conforming to IS:2074-1979) welded and bolted including special shape washer etc. complete. (a) Electric resistant welded tube (Conforming to IS:1611-1979) |
| 14 | Steel work welded in built up sections, framed work in cutting, hoisting, fitting in position & priming coat of red lead paint . In gratings, framed guard bars, ladders, railings, brackets and similar works. |
| 15 | Supplying and fixing welded steel wire fabric to wood or steel members in partition etc. a) Weight exceeding 2 kg/sqm but not exceeding 3 kg/sqm |
| 16 | Trapzoidal Pre-painted Profile Sheet roofing of approved brand DYNA Roof or equivalent with selt drilling screws of 68 mm long Xylon coated screws with PVC washer & caps complete, exclding the coat of purlinsr & trusses.Pre painted Galvalume Sheet (PPGL)i) Profile sheet 0.50 mm/4.2 kgs/sqm |
| 17 | Trapzoidal Pre-painted Profile Sheet for RidgesGutter or Valley 610 mm wide of approved brand DYNA Roof or equivalent fixed with selt drilling screws of 68 mm long Xylon coated screws with PVC washer & caps completed, exclding the coat of purlins rafter & trusses.Pre painted Galvalume Sheet (PPGL)i) Profile sheet 0.50 mm/4.2 kgs/sqm |
| 18 | Providing and fixing 20mm plank as eave board with :- (b) Tolhao/Uchan wood |
| 19 | 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. |
| 20 | Painting (two or more coats) with synthetic enamel paint of approved quality of black or chocolate colour on wood work to give an even shade. |
| 21 | Distempering (two or more coats) with oil bound washable distemper of approved quality on new work i/c priming coat to give an even shade. |
| 22 | 75 mm cement concrete flooring 1:2:4 (1 cement: 2 coarse sand:4 stone aggregate 20 mm & down gauge) finished with a floating coat of neat cement. |
| 23 | S.H : Electrical Works |
| 24 | Wiring for light point / Fan point / Exhaust Fan point / Call bell point with 1.5 mm2 FR PVC insutated copper conductor single core cable in PVCcasing & capping with modular type switch, modular plate suitable size,G.I-box and earthing the point with 1.5 mm2 FR PVC insulated copper conductor single core cable etc. as reqd. |
| 25 | 2. Group B |
| 26 | Wiring forPower Plug point with 2 x 4mm2FR PVC insutatedcopper conductor single core cable in PVC casing & capping along with 1 no. 4 mm2FR PVC insulated copper conductor single core cable for loop earthingetc. as reqd. |
| 27 | Supply and drawing the following size ofPVC insulated Al. conductor single core cable in existingPVC casing & capping etc. as reqd |
| 28 | 2.2 x 1.5 mm2 |
| 29 | 7.2 x 2.5 mm2 |
| 30 | 12.2 x 4 mm 2 |
| 31 | Wiring for circuit / Sub - main wiring along with wire with ( the following size of ) PVC insulated Al. conductor single core cable in PVC cassing & capping etc. as reqd. |
| 32 | 5.2 x 10 mm2 + 1 x 10 mm2 earth wire |
| 33 | S/F 152.4 mm x 203.2 mm ( 6\" x 8\") PVC board |
| 34 | S/F square box 12 mm to 32 mm |
| 35 | S/F brass batten/ angle holder i/c connectio etc. as reqd. |
| 36 | Supply & Fixing( followingpiano type switch / socket) on the existing switch box / cover i/c connection etc. as reqd. |
| 37 | 1. 5 / 6 amps switch |
| 38 | 4. 3 pin 5/6 amps socket outlet |
| 39 | S/F PVC box of size 203mm x 178mm ( Nominal size) ( 6\" x 8\") PVC board on surface incuding P/F 6 pin 15/16 amp socket outlet and 15/16 amp piano type switch, connection etc. as reqd. |
| 40 | S/F 56 \" sweep (1400 mm) A.C ceiling fan complete with down rod, canopy, 3 (three ) blades but without regulator etc. as reqd. ( Make Bajaj / Usha or similar ) |
| 41 | Supplying & Fixing stepped type electronic Fan Regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as reqd. |
| 42 | S/F 3 pin 5 amp ceiling rose on the existing junction box / wooden block i/c connection etc. as reqd. |
| 43 | Providing and Fixings ( following capacity TP & N ) dis-connector fuse switch unit inside the existing cubical panel board with ISI marks HRC fuses including drilling holes in the cubical panel board, making connection as reqd. |
| 44 | 2. 63 amp TP & N |
| 45 | S/F Bus bar chamber with 4 strips bus bar of length 300 mm suitable for 63 amp capacity complete with all accessories i/c connection, earthing the body etc. as reqd. |
| 46 | S/F ( following way), single / double pole and neutral, sheet steel MCB distribution board, 240 V on surface / recessed complete with tinned copper bus bar neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphatized and powder painted including earthing etc. as reqd. ( but without MCB / RCCB / Isolator) |
| 47 | 3. 8 way single door |
| 48 | Supplying and fixing 5 amp to 32 amp rating 230 V \"B\" series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection, testing and commissioning etc. as reqd. |
| 49 | 1.Single Pole |
| 50 | S/F ( following rating) double pole 240 V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd. |
| 51 | 2.63 amp |
| 52 | S/F 23 W CFL. Lamp |
| 53 | Earthing with copper plate 600 mm x 600 mm x 6 mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) as reqd. |
| 54 | Extra for using salt and charcoal for G.I or copper plate earth electrode as reqd. |
| 55 | P/F 25mm x 5mm copper strip in 40 mm dia G.I pipe from earth electrode as reqd. |
| 56 | S/L 8 SWG copper wire on surface or in recessed for loop earthing along with existing surface / recessed conduit wiring/ sub main wiring / cable as reqd. |
| 57 | Supplying of KirloskarKDS 312 3.0 HP CIIMS single phase Monobloc Pump set i/c GST |
| 58 | Supplying of Kirloskar portable 5 KVA diesel generator i/c GST and delivery Charge( Velgeneratoe ,com) |