| 1 | DISMANTLING : Textile coverings including frames (if any) and cover fillets (measured flat and not girthed).The debris to be deposited n exc 100m as directed by the EIC. |
| 2 | DISMANTLING : Demolitionof Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work.The debris to be deposited n exc 100m as directed by the EIC.. |
| 3 | DISMANTLING :Demolitionof Unreinforced cement concrete Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 4 | DISMANTLING :Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 5 | Cutting holes: Cutting holes into or through cement concrete slabs, chajjas, etc. Superficial area Nexc 100 sq.cm.reinforced cut through |
| 6 | Cutting holes:Cutting holes into or through brick walls in brick walls built, in cement mortar Superficial area Nexc 150 sq.cm. and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required |
| 7 | Removal of Spoil: Removing building materials etc. to a distance of 500m or under, beyond thelead included in the rates, includingloading, unloading and stacking at thedestination.For Aggregate(500cum ÷0.62 cum)= 806.45 Load Say 968 Load |
| 8 | P.C.C : Cutting channels, in PCC Parapet grooves or rebates n exc 15cm girth, and trimming surface |
| 9 | P.C.C : Providing PCC in ratio type-B0, 1:2:4 (12.5mm graded aggregate) in roof kerbs or mud stops, round or chamfered on edges, using coarse sand and approved quality cement as per specifications. The rates include for use of formwork (straight or curved). Complete in all respect as directed by EIC. |
| 10 | P.C.C : Supply of Liquid water proofing compound Requirement- 350ml per cum. (Material only) |
| 11 | P.C.C : Finishing cement concrete surface even and smooth using extra cement. M & L |
| 12 | CEMENT CONCRETE IN SUB-FLOORS, SUB-BASES, FLOORS AND PAVINGS, ETC.: Reinforced Cement concrete 100mm thick on floors type B- 2, 1:2:4 (40mm graded aggregate) |
| 13 | Finishing cement concrete surface even and smooth using extra cement. M & L |
| 14 | Reinforcement with TMT steel bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips |
| 15 | Taking down cement plaster or lime cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, any description. The debris to be deposited n exc 100m as directed by the EIC |
| 16 | PLASTERING : Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. Ordinary cement finish using ordinary cement. |
| 17 | PLASTERING : Rendering/ Plastering 12mm thick with Cement Morter 1:4 on fair faces of brick work or concrete surfaces The rates include for finishing the surface fair and even |
| 18 | WIRE CLOTH : Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples but 0.56mm nominal dia of wire and average width of aperture 1.18mm |
| 19 | SCAFFOLDING :Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/ structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. |
| 20 | BRICK WORK : Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radious built in thick walls built in cement mortar 1:6 |
| 21 | MS FRAME WORK : Supplying & fixing MS frame work confirming to Fe 410 -W (Gde- E- 250) quality- A. rate including notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up drilling the members for site connections; and fixing painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete. |
| 22 | MS frame workin Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. complete framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. fixing complete |
| 23 | Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 24 | Excavating over areas, n. exc 1.5 m deep and getting out in hard /dense soil. |
| 25 | RCC type B-1 1:2:4 , 20mm graded aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete |
| 26 | Painting: Weather Coat Paint: Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces.including Preparation of surface by Washing, rubbingdown and stopping of distempered andpainted surfaces. |
| 27 | DISTEMPER: Preparation of surface by Washing, rubbing down and stopping of distempered and painted surfaces.One coat Cement wash with Portland cement slurry to a smooth bodied opaque finish on newly plastered surfaceTwo coat Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. |
| 28 | DOWN TAKE PIPE (M&L):Supplying, laying, cutting, fitting & fixing of Down Take pipes in any length including weding, fixed to walls complete with suport, fitting bend, tees, flanges and all necessary accessories in any lenth laid inwall support. the joints of pipeline should be made water proof. M&L:300 mm dia |
| 29 | DOWN TAKE PIPE (M&L):Supplying, laying, cutting, fitting & fixing of Down Take pipes in any length including welding, fixed to walls complete with suport, fitting bend, tees, flanges and all necessary accessories in any lenth laid in wall support. the joints of pipeline should be made water proof. M&L: Nozzle 150 mm dia MS Pipe |