| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 2 | Demolishing nominal cement concrete 1:3:6 or richer mix manually/ by mechanical means including stacking of steel bars and disposal of unserviceable materials within 50metres lead as per direction of Engineer-in-charge. |
| 3 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :15 mm to 40 mm nominal bore |
| 4 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 5 | Dismantling existing rolling shutters made of MS Laths, interlocked and jointed at the end i/c shaft, bracket, side guides, springs, top cover, all other components etc complete with all lift and stacking at the disposal point with a lead upto 2 Km within ONGCNhava complex. |
| 6 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 150 mm dia pipe |
| 7 | Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material within all lifts and lead upto 1km (by mechanical means). |
| 8 | Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.Note : 1) Excess/less cement used than specified in this item is payable/recoverable separately.All works upto plinth level M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) |
| 9 | Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.Note : 1) Excess/less cement used than specified in this item is payable/recoverable separately.All works upto plinth levelM-10 grade plain cement concrete (cement content considere @ 220 kg/cum) |
| 10 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level; Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 14 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS: 4457,complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand).Acid and alkali resistant tile |
| 15 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. |
| 16 | Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 17 | 12 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand) |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Cold twisted bars |
| 19 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 20 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 21 | Extra for providing mechanical device chain and crank operation for operating rolling shutters Exceeding 16.80 sqm in area |
| 22 | Providing and fixing ball bearing for rolling shutters. |
| 23 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 24 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 25 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. Two or more coats on new work |
| 26 | Finishing walls with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 28 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete |
| 29 | Supplying and fixing C.I. cover without frame for manholes: 455 x 610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg |
| 30 | 52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound is mixed @ 2 litre per 50 kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete |
| 31 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors - 40 mm wide and 4 mm thick |
| 32 | Supply of dumper on hire charges inclusive of diesel, lube oil, cleaner, driver etc without labourers |
| 33 | Total Amount of Civil Works excl. taxes |
| 34 | Description of item |
| 35 | a) Design, Engineering, Manufacturing and Fabrication of PEB structure and its components like roofing ,wall cladding etc. complete including supply of all components viz. PEB structure, Turbo ventilators, Anchor bolts and connections, Main frame ,columns and rafters, purlins, Grit, Eave struts, bracings, Roof Sheeting & Wall Cladding, framed opening for doors & windows, fasteners, Paints and all other items required to erect the shed at site as per design done and got vetted from IIT Mumbai/ VJTI, Mumbai/ COE, Pune/ equivalent government institute including providing Design calculations, working drawings, Detailed Specifications, etc. as per scope of work, technical parameters and indicative shed layout given in the drawing. Golden parameters for designing the shed include the following: i) Size of the shed at G.L. would be 50mx37.5m and the height of shed shall be 8.0m at the ends with proper slope, however, the vertical sheet cladding shall drop 6.0 meter from the edge. ii) Structural provision for installation of Solar panels on roof with a uniform distributed load of 18kg/m2. iii) Structural provision for Electric Overhead Travelling crane (EOT) of 10T capacity @6.0m height from FFL.· Erection of PEB shed shall be carried out strictly as per design vetted by the institute as mentioned above.· Adequate factor of safety shall be considered for designing the structural components w.r.t golden parameters.· Appropriate codes may be followed. |
| 36 | b) Design & Engineering of PEB substructure as per the load calculations of PEB superstructure at S.No.(a) and the same shall be vetted from IIT Mumbai/ VJTI, Mumbai/ COE, Pune/ equivalent government institute including working drawings, detailed specifications, etc. as per requirement. |
| 37 | Total Amount of PEB Works excl. taxes |
| 38 | Details Of Items |
| 39 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 40 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 41 | Excavating hard murum / metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete. |
| 42 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 43 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 44 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 45 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 46 | Supplying High BayLED Light 200 Watt, 240 Volts, 50 Hz, IP 65, Luminaire System Efficacy - Lumen output - (Lumen::Watt)≥ 120 |
| 47 | Providing and erecting air circulator 600 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles A.C. supply, core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. |
| 48 | Supplying, erecting & terminating XLPE armoured cable 1100 V. 4 core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 49 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm |
| 50 | Supplying, erecting & terminating XLPE armoured cable 1100 V. 4 core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 51 | Supplying, erecting & terminating XLPE armoured cable 1100 V. 4 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 52 | Providing & erecting floor / wall mounting, MCCB panel board with door suitable for four pole incoming 250A, 4 ways four pole outgoing upto 100 A MCCB\"s on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCB\"S) |
| 53 | 4 pole MCCB,250A, 36KA |
| 54 | 4 pole MCCB, 125A, 36KA |
| 55 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 56 | 4 way (4 + 12), Double door |
| 57 | 8 way (4 + 24), Double door |
| 58 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 59 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral |
| 60 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required40 A |
| 61 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A |
| 62 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV /HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 63 | Supplying and erecting LED street light fitting suitable for above 70W- 75W lamp, including lamp, with PF > 0.95 classIP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG-ODF/FLS2 |
| 64 | Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 65 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 66 | Supplying & erecting FRP box of size 250 x 200 x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. CB-SB |
| 67 | Supplying, erecting & terminating XLPE armoured cable 1100 V. 4 core 4 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 68 | Total Amount of Shed No.1 incl. Civil, PEB & Electrical Works excl. Taxes |