Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | B-44/1.8 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 2 | B-54/3.1.6 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 3 | B-69/6.1.6 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 4 | B-65 /5.2.2 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 5 | B-66/5.9 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry . |
| 6 | B-66/5.8.3 Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75 .Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 7 | B-99 /9.6.2 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge :Profile C |
| 8 | B-93 /8.13.2.1 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure \"A\"::Commercial Veneer both side.30 mm thick .Commercial Veneer both side |
| 9 | B-90 /8.4.2.3 Providing and fixing fully panelled/partly panelled/double leaf shutter frames for doors as per approved design and drawings with approved ordinary C.P./ oxidised steel fittings as per Annexure - \"A\" and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete : :30 mm thick Shesham wood grade I |
| 10 | B-59 /4.1 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 11 | B-59 /4.2 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix |
| 12 | B-59/4.3 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 13 | B-62 /4.13.2 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (\"Original producers\" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 14 | B-61 /4.9 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
| 15 | B-61 /4.10.2 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 16 | B-61/4.10.3 ---DO---Columns,pillars,posts&strutsetc. |
| 17 | B-83 /7.3.3 Providing and fixing Marble stone flooring table rubbed, 15-18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Keseriaji/ Abu Ambaji (Green Marble)Above 3601 Cm2 Slabs |
| 18 | B-132 / 11.18.2Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand):For area of each slab from 2001 to 5000 Sq.Cm. |
| 19 | B-86 /7.13 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 20 | B-86/7.12 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 21 | B-95 /8.25.2 Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete:20 mm |
| 22 | B-139/12.3.2 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. |
| 23 | B-139/12.3.3 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 12 mm thick. |
| 24 | B-139/12.2.3 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :(A)12 mm thick |
| 25 | B-104 /9.39 Providing and fixing of double leaf steel shutterfor cupboard, the frame is made of pressed steelISI section 80x25 mmx1.25 mm thickwith 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc completeincluding applying priming coat of approved steel primer of red oxide zinc chromate andspray painting in approved shade with decopaint of approved quality complete as per direction of Engineer In Charge |
| 26 | B-111 /10.22 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 27 | B-101 /9.19.3 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required ::Windows side hung /Ventilators top or centre hung (openable) |
| 28 | B-177 /16.11 S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. |
| 29 | B-102/9.27 Providing and fixing Square bars or other flat welded to window, ventilatiors etc. |
| 30 | B-101 /9.17 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 31 | B-98 /9.2 Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 32 | B-99/9.8 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 33 | B-98 /9.5 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 34 | B -142/12.23 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 35 | B-142/12.22.1Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete.New Plastered Surface (three or more coats) |
| 36 | B-107/10.17.1 Grading roof for water proofing treatment withwater proffing compound : Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 37 | B-146/12.46.1 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on New Work |
| 38 | B-144/12.37.1 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including priming coat with cement primer. |
| 39 | B-145 /12.42 Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). |
| 40 | B-103 /9.33 & 9.35 Add or deduct for over basic item Extra for using galvanized barbed wire instead of black barbed wire. |
| 41 | B-54/3.1.2 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost ofcentering and shuttering - All work up to plinth level. .M15 grade Nominal Mix1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). |
| 42 | B-55/3.3.1 Providing and fixing up to floor five level pre cast cement concrete string or lacing courses, copings, bed plates, anchor blocks, windows sills, shelves, louvers steps, staircases, etc. including carriage, hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surface, including all T & P, curing etc. complete: M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). |
| 43 | B-48 /1.25 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth,consolidating each deposited layer by ramming and wateringincluding lead upto 50 meter and with all lift. |
| 44 | B-50/ 1.35.3 Treatment of soil under existing floors using chemical emulsion @one litre per hole, 300 mm apart including drilling 12 mm diameterholes and plugging with cement mortar 1 : 2 (1 cement : 2 Coarsesand) to match the existing floor. With Chlorpyriphos/Lindane E.C.20% with 1% concentration. |
| 45 | B-69 / 6.3.4 Add extra for Random Rubble stone masonry with hard stone in : Wall upto 30 cm and less thickness. |
| 46 | B-63/4.19.3 Providing, hoisting and fixing up to floor five level precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6mmnominal size) reinforced with 1.6 mm dia Mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1 : 3 (1 cement : 3 fine sand ) etc complete as per approved design excluding plastering of jambs, sills and soffits . 30 MM THICK |
| 47 | B -92/8.6.8 Providing and fixing wood panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutter 25 mm to 40 mm thick :Wire gauge 24 gauge 14 mesh of IS 1568-1970 marked 85 gauge of dia 0.56 mm |
| 48 | S-217 /1.2.2 P & F Indian type white glazed vitreous china Ist quality W.C. orissa pan (IS:2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor : 580x440 mm. |
| 49 | S-217 /1.4P & F European type white glazed vitreous china Ist quality W.C. pan (IS:2556 Mark) with P or S trap including cutting and making good the wall and floor. |
| 50 | S-218 /1.7.2 P & F water closet Seat Covers with brass hinges complete : Solid PVC (ISI marked) grade-I White for EWC. |
| 51 | S-219/1.20.3 P & F Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall : PVC with PVC bend as per IS:7231. |
| 52 | S-221/1.36.3 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make 25 mm G.I. waste pipe complete including cutting & making good the wall : Size 550mm x 400mm |
| 53 | S-223 /1.45.1 P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge:Size 500x400 mm. |
| 54 | S-223 /1.47.4P&F towel rail or ring of approved quality /make: C.P. brass towel rail with brackets 600x20 mm |
| 55 | S-240/2.37.2(a)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall). (Internal work Exposed on wall) :20mm nominal size. |
| 56 | S-240 /2.37.3 (b) ____do_____25 mm nominal size. |
| 57 | S-240 /2.39.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (b) 25 mm dia nominal size |
| 58 | S-232 /2.7.3 P & F Bib Cock (IS:8931 Mark) Superior quality of approved make : (a) C.P. Brass bib cock, 15 mm nominal bore. |
| 59 | S-232 /2.7.4 (b) -do- Long body, 15 mm nominal bore weight not less than 690 gm.B628 |
| 60 | S-232 /2.8.5(b) -do- Concealed Stop Cock 15 mm. |
| 61 | S-247/3.16.3 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant.: 110 mm dia |
| 62 | S-257 /3.45.6_Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make:.__Door Bend 87.5 Dg. 110mm dia |
| 63 | S-236 /2.26.3P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: . 500 (liters capacity). |
| 64 | S-250 /3.19.1 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 m |
| 65 | S-251 /3.21.1 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.Inside size 300 X 300 mm depth upto 0.5 MCement cover with frame.. |
| 66 | S-224 /1.48.1P & F Grating of approved quality/make :Stainless Steel Grating125 mm Nominal dia. |
| 67 | S-252 /3.22.1 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 300 Cm. dia outside & 300 Cm. depth . |
| 68 | S-253 /3.27.1Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 gradeC.C floor &RCC slab covering with M15 grade c.c. floor,50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 200x100x130 cm.(for 10 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 8mm ϕ @15 cm c/c bothways including shuttering complete in all respect. |
| 69 | S-226 /1.59 P&F Jet spray for water closet with C.P. copper tube flange of approved make. |
| 70 | S-225 /1.55.3P & F Bath Shower of approved quality/make. : C.P. brass of Heavy & superior quality, revolving with adjustable key 150mm. |
| 71 | S-233 /2.12.1 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, C.P. Inlet connection 15 mm Brass (IS:8931 marked). |
| 72 | S-225 /1.54.1 P&F Shower arm 15mm dia of approved quality/ make.C.P. brass heavy & superior quality 150mm projection. |
| 73 | S-222/1.38.9.3P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : : Stainless steel kitchen sink - without drain board 24 x 18 x 8 Overall size20x16x8Bowl size |
| 74 | S-231 /2.6.1 P & F Pilllar Cocks (IS :8934 Mark) of superior quality and approved make: C.P. Pillar cock, 15 mm dia nominal bore |
| 75 | S-232 /2.7.2 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:P.V.C.heavy duty, 15mm nominal bore. |
| 76 | S-244 /3.4.1 Providing & fixing S.W. square mouth Gully trap `A` grade (ISI marked)of approved make & design in existing man-hole 100 X 100 MM |
| 77 | B)Add Extra if Square ,rectangular Hollow ,tubular sections are used or grill made by flats only (7.5%) |
| 78 | H-271/1.1.1Supply of dry manure including loading unloading,transportation & stacking at site..Farm yard manure(organic) |
| 79 | H-271/1.3.1 Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc.Good soil of earth |
| 80 | H-272 /1.4.5 Supply of insecticides & pesticides at store in dust/liquid formcomplete:Cholorophyriphos 20 Ec. |
| 81 | H-279/2.2 Digging pits in ordinary soil and refilling the same with the excavated earth mixed with manure in the ratio of 2:1 by volume ( 2parts of stacked volume of earth after reduction by 20% 1 part of stacked volume of manure after reduction by 8%) flooding wit |
| 82 | H-278 /2.1.1 Spreading of manure , good earth in required thickness (cost of manure and good earth to be separately ) |
| 83 | H-273/1.11.1 Supply of different varities of tree/shrubs/climbers according to height and age of the plant at side including loading/unloading & transportation etc.complete:Different flowering plants 900 mm to 1500 mm |
| 84 | H-273/1.11.3 Supply of different varities of tree/shrubs/climbers according to height and age of the plant at side including loading/unloading & transportation etc.complete Different varieties of climbers 900 mm to 1500 mm. |
| 85 | H-280/3.3 Planting of trees/Shurbs/hedge & climbers plants at desired distance in a row & watering |
| 86 | H-281/4.2 Maintenace of Plants by the contractor including of pits/bids watering preparation of Thavala Hoeing weeding etc. & application of insecticides etc. & security if the plant die during maintenance contractor has to replace same height plant at his own cost. |
| 87 | H-280/3.1.2 Laying of lawns including ploughing levelingbreaking of clods manuring and removal of stones etc. (cost of manure or extra good earth to be paid separately )maintenance of lawn foe 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost: In rows 7.5 Cms. apart in either direction. |
| 88 | H-272/1.6.2 Supply of different sized pots at site store including loading unloading & transportation etc. complete.. : Cement pot 350 mm size. |
| 89 | B-135/11.38.1 (c)Providing and laying ofpaver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement)M-30, 60 mm thick to be used in non traffic areas like building premises, monument premises, land scapes, public gardens/ park, domestic drives, paths and patios, Embankment slopes, sand stabilization Area etc.( As per table 1 ofIS 15658:2006 Category ‘C’not denated on any it’s faces like Hexagon, Rectangular, square shape as per IRC SP 63:2004 |
| 90 | B-104/9.38.3 Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 25 mmx 25 mm x 2.1 mm |
| 91 | R-11/3.5.(ii) Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. |
| 92 | R-14/3.15 ( ii) Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300-1 and 300-2 for subgrade construction as per MoRTH Specification Clause 305.3.4 |
| 93 | R-16/4.1 (B) (iii) Construction of granular sub-base by providing well graded material, spreading in uniform layerson prepared surface, mixing by manual mean method at OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per MoRTH Specification Clause 401.For Grading IIIMaterial |
| 94 | R-76/16.53.5 Supply & fixing of M-20 grade precast cement concrete Kerb or Dand upto 60 cm length over 20 mm thick base of cement mortar 1:6 including jointing earth work, painting & jointing with cement mortar 1:4 of size(20 x 25)/2 x 30 cm |
| 95 | R-28 / 6.1 Construction ofun-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavementof M-30 Grade, thickness as per design, over a prepared sub base, withcement or any other type as per Clause 1500.2.2 of MoRD Specification, coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate 31.5 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days,using curing compoundand water finishing to lines and grade as per drawingand MoRD Specification Clause 1500 including vaccum dewatering process with all required equipments |
| 96 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5sq.mmnominalsizeFRPVCinsulatedunsheathedflexiblecopper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathedflexiblecopperearthconductor1.1kVgrade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot DippedGalvanizedModularBoxwithearthterminal,10AModular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3wayconnector,screws, makingconnections,testingetc.asrequired. Forspecificationofcopper Conductor, PhenolicLaminatedsheet\"s& Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additionaltechnicalparametersofproduct/workreferAnnexure\"A\" attached with thisShort point (up to 3 mtr.)Code--1.1.1 |
| 97 | Medium Point Code-1.1.2 |
| 98 | Long PointCode-1.1.3 |
| 99 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFRPVCinsulatedunsheathedflexiblecopperconductor1.1kVgrade and1.5sq.mmnominalsizeFRPVCinsulatedunsheathedflexible copperearthconductor1.1kVgrade(IS:694) in recessedISImarked MMS(IS:9537P -III )PVC conduit&it\"sISI marked(IS:3419- 1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc.asrequired. Forspecificationofcopper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.On board.Code-1.3.1 |
| 100 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductorasperPWDspecificationforelectricalWorkswithISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should bemadefrom 99.90%puritycopper,class5strandinginacc.to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization,insulationPVCtypeA/C/D,flameretardantasperIS 10810-53,betteramperageratingasperIS:3961part5, inexistingsurfaceorrecessedPVC/MS conduit/casingcapping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.OEMMusthaveitsowninhouseNABLlabsetupforall testingfacilitiesforwires.Foradditionaltechnicalparametersof product / work refer Annexure \"A\" attached with this BSR 2 x 2.5 Sqm.Code-4.1.6 |
| 101 | 2 x 4.0 Sq.mmCode-4.1.11 |
| 102 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III)PVCconduitalongwith ISImarked(IS:3419-1988)accessoriesas required in recess including cuttingthewall,coveringconduitand making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR -20mmCode-1.4.1 |
| 103 | 25mm Code-1.4.2 |
| 104 | Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. Code-7.36 |
| 105 | Providing& FixingofISImarkedsurfacetype buzzer(IS:2268-1994) with CM/L no. printed including making connection testing etc. as required. All asperpreapprovedbyEngineerincharge. Foradditionaltechnical parametersofproducts/work ,refer Annexure\"A\"attachedwiththis Code-7.24 |
| 106 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR1170mm(+/-10%) LED batten with min. lumen output 2200 lm Code-17.1.1 |
| 107 | P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Code-5.9 |
| 108 | Providing & Fixing ofof ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 250 mm sweep. Code-15.13.3 |
| 109 | Supply & Fixing of phenolic laminated board of 6.4 mm thick for fresh air fan/exhaust fan up to size of 300 mm on existing window frame including cost of board, cutting of hole , Nut bolts etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Code-15.2 |
| 110 | Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) Code-15.7.3 |
| 111 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.6 A to 32 A rating Code-6.1.1.2 |
| 112 | Providing & Fixing of 240/415 V isolator ISI marked IS:13947- III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.Double pole isolator. 63 A rating. Code-6.2.1.2 |
| 113 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. Metal door (single phase) IK-09 and IP-43 with Metal end box. 8 Way (8+2) Code-6.10.1.3 |
| 114 | P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.4.8 mm thick. Code-5.5.2 |
| 115 | Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure \"A\" attacheded with this BSR.15 Watt Code-17.9.4 |
| 116 | Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR. Code-7.12 |
| 117 | Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .Code-7.13 |
| 118 | Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam freelid suitablefor safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensureto enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Code-14.2 |
| 119 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .10 SWG G.I. ( Hot Dipped ) Wire. Code-14.6.9 |
| 120 | Wiring of twin control light / Fan / Call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed/surface ISI marked ( IS:9537 P - II ) rigid steel conduit & it\"s ISI marked (IS:14768 P-II 2003) accessories, round tiles, 2 Nos Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 2 Nos 10A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, pvc bushes, check nuts, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. Short point (up to 03 mtr.).Code-2.2.1 |
| 121 | Providing & Fixing of IP65 IK08 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable with integral driver, system lumen efficacy ≥100 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. surge protection 4 KV. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Minimum lumen output 1000 lm.Code-17.6.1 |
| 122 | Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 6.0 sq.mm.Code-4.6.2 |
| 123 | P & F 1.2 mm thick G. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additionaltechnical parameters of product / work refer Annexure \"A\" attached with this BSR. 1.2 mm thick M. S. Sheet boxes . 1.2 mm thick M. S. Sheet boxesCode-5.1.1.4 |
| 124 | Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.5 step fan regulator 2 Module 360 dgree rotating. Code-7.21.1 |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail