Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for all kinds of soil. |
| 2 | Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. |
| 3 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. for all kinds of soil. |
| 4 | Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 5 | Providing and laying in position cement concrete of grade 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level : |
| 6 | Providing and laying in position cement concrete of grade1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level : |
| 7 | Providing and laying in position cement concrete of grade 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level : |
| 8 | Providing and laying cement concrete 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. |
| 9 | Providing and fixing up to floor five level precast cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. |
| 10 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 11 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer\"s specification. |
| 12 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 13 | Providing and laying in positiongrade 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 14 | Providing and laying in positiongrade 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 15 | Reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 16 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ) |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for Spiral staircases (including landing) |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form for Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 26 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 27 | Edges of slabs and breaks in floors and walls Above 20 cm wide |
| 28 | Cornices and mouldings |
| 29 | Centering and shuttering including strutting, propping etc. and removal of form for Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like |
| 30 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges |
| 31 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 32 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 33 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 34 | Mild steel and Medium Tensile steel bars for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 35 | Mild steel and Medium Tensile steel bars for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 36 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). |
| 37 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 38 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 39 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 40 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) |
| 41 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 42 | Providing and fixing 18 mm thick Granite stone slab of colour black, Cherry/Ruby red gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels (for Area of slab upto 0.50 sqm) |
| 43 | Providing and fixing 18 mm thick Granite stone slab of colour black, Cherry/Ruby red gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels (Area of slab over 0.50 sqm) |
| 44 | Providing and fixing 18 mm thick Granite stone slab of all colour and texture except black, Cherry/Ruby redgang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels (Area of slab upto 0.50 sqm) |
| 45 | Providing and fixing 18 mm thick Granite stone slab of all colour and texture except black, Cherry/Ruby redgang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels (Area of slab over 0.50 sqm) |
| 46 | Providing edge moulding to 18 mm thick Granite workcounters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 47 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 48 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 49 | Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : |
| 50 | Providing and fixing 4mm thick coir veneer board, ISI marked IS : 14842, plain lining with necessary screws, priming coat on unexposed surface etc., complete. |
| 51 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 52 | Providing Second class teak wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 53 | Providing Sal wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 54 | Providing Kiln seasoned and chemically treated hollock woodwork in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 55 | Providing and fixing 2nd class teak wood size 50x12 mm moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 56 | Providing and fixing 2nd class teak wood size 50 x 20 mm moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 57 | Providing and fixing Kiln seasoned and chemically treated hollock wood size 50 x 12 mm moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 58 | Providing and fixingKiln seasoned and chemically treated hollock wood size 50 x 20 mm moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 59 | Providing and fixing Second class teak wood panelled or panelled and glazed 35 mm thick shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) |
| 60 | Providing and fixing Second class teak wood panelled or panelled and glazed 30 mm thick shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) |
| 61 | Providing and fixing Kiln seasoned selected planks of sheesham woodpanelled or panelled and glazed 35 mm thick shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) |
| 62 | Providing and fixing Kiln seasoned selected planks of sheesham woodpanelled or panelled and glazed 30mm thick shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) |
| 63 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 64 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 65 | Providing and fixing35mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Second class teak wood) |
| 66 | Providing and fixing30mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Second class teak wood) |
| 67 | Providing and fixing35mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Kiln seasoned and chemically treated hollock wood) |
| 68 | Providing and fixing30mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Kiln seasoned and chemically treated hollock wood) |
| 69 | Providing and fixing35mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Kiln seasoned selected planks of sheesham wood) |
| 70 | Providing and fixing30mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Kiln seasoned selected planks of sheesham wood) |
| 71 | Providing and fixing30mm thick Panelled or panelled & glazed shutters for cup board using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws) |
| 72 | Providing and fixing30mm thick Panelled or panelled & glazed shutters for cup board using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws) |
| 73 | Providing and fixing30mm thick Glazed shutters for cup board using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Second class teak wood including ISI marked anodized aluminium butt hinges with necessary screws) |
| 74 | Providing and fixing30mm thick Glazed shutters for cup board using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws) |
| 75 | Providing and fixing ISI marked 35mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including ISI marked Stainless Steel butt hinges with necessary screws) |
| 76 | Providing and fixing ISI marked 30mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including ISI marked Stainless Steel butt hinges with necessary screws) |
| 77 | Providing and fixing ISI marked 25mm thick flush doorshutters (for cupboard) conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws) |
| 78 | Providing and fixing ISI marked 35mm thick flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including ISI marked Stainless Steel butt hinges with necessary screws) |
| 79 | Providing and fixing ISI marked 30mm thick flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including ISI marked Stainless Steel butt hinges with necessary screws) |
| 80 | Providing and fixing ISI marked 25mm thick flush door shutters (for cupboard) conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws) |
| 81 | Extra for Providing and fixing flush doors with On one side only decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) |
| 82 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 83 | Extra if louvers (not exceeding 0.2 sqm) are provided in Decorative type door flush door shutters (overall area of door shutters to be measured). |
| 84 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 85 | Providing and fixing 30mm thick Second class teak wood wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws (with ISI marked M.S. pressed butt hinges bright finished of required size) |
| 86 | Providing and fixing 30mm thick Kiln seasoned and chemically treated hollock wood wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws (with ISI marked M.S. pressed butt hinges bright finished of required size) |
| 87 | Providing and fixing 30mm thickKiln seasoned selected class of sheesham wood wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws (with ISI marked M.S. pressed butt hinges bright finished of required size) |
| 88 | Providing and fixing 30mm thick Second class teak wood wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws (With ISI marked stainless steel butt hinges of required size) |
| 89 | Providing and fixing 30mm thick Kiln seasoned and chemically treated hollock wood wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws (With ISI marked stainless steel butt hinges of required size) |
| 90 | Providing and fixing 30mm thick Kiln seasoned selected class of sheesham wood wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws (With ISI marked stainless steel butt hinges of required size) |
| 91 | Providing and fixing 12mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws andPVC sleeves etc., wherever necessary complete : |
| 92 | Providing and fixing 20mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws andPVC sleeves etc., wherever necessary complete : |
| 93 | Providing and fixing 25mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws andPVC sleeves etc., wherever necessary complete : |
| 94 | Providing and fixing 20mm dia (heavy type) nickel plated M.S. pipe curtain rods with nickel plated brackets : |
| 95 | Providing and fixing 25mm dia (heavy type) nickel plated M.S. pipe curtain rods with nickel plated brackets : |
| 96 | Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. |
| 97 | Providing and fixing 125x65x2.12 mm ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) |
| 98 | Providing and fixing 100x58x1.90 mmISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) |
| 99 | Providing and fixing 75x47x1.70 mmISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) |
| 100 | Providing and fixing 50x37x1.50 mmISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) |
| 101 | Providing and fixing 150x125x27x2.80 mm ISI markedIS: 1341 oxidised M.S. pressed Parliamentary hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 102 | Providing and fixing 125x125x27x2.80 mm ISI markedIS: 1341 oxidised M.S. pressed Parliamentary hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 103 | Providing and fixing 100x125x27x2.80 mm ISI markedIS: 1341 oxidised M.S. pressed Parliamentary hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 104 | Providing and fixing 75x100x20x2.24 mm ISI markedIS: 1341 oxidised M.S. pressed Parliamentary hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 105 | Providing and fixing 150 mm ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 106 | Providing and fixing 125 mm ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 107 | Providing and fixing 100 mm ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 108 | Providing and fixing150 mm ISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 109 | Providing and fixing125 mmISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 110 | Providing and fixing100 mmISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 111 | Providing Overall width 35 mm M.S. Piano hinges ISI marked IS : 3818 finished with nickel chromium plating grade 1 as per IS: 1068 and fixing with necessary screws etc., complete. |
| 112 | Providing Overall width 50 mm M.S. Piano hinges ISI marked IS : 3818 finished with nickel chromium plating grade 1 as per IS: 1068 and fixing with necessary screws etc., complete. |
| 113 | Providing Overall width 60 mm M.S. Piano hinges ISI marked IS : 3818 finished with nickel chromium plating grade 1 as per IS: 1068 and fixing with necessary screws etc., complete. |
| 114 | Providing and fixing 300x16 mm ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) |
| 115 | Providing and fixing 250x16 mm ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) |
| 116 | Providing and 250x10 mm fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 117 | Providing and 200x10 mm fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 118 | Providing and 150x10 mm fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 119 | Providing and 100x10 mm fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 120 | Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete (Copper oxidised as per IS 1378). |
| 121 | Providing and fixing 300x20x6 mm ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete (Copper oxidised as per IS 1378) |
| 122 | Providing and fixing 250x20x6 mm ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete (Copper oxidised as per IS 1378) |
| 123 | Providing and fixing 125 mm ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 124 | Providing and fixing 100 mm ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 125 | Providing and fixing 75 mm ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 126 | Providing and fixing 150 mm oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 127 | Providing and fixing 115 mm oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 128 | Providing and fixing 90 mm oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 129 | Providing and fixing 300 mm (weighing not less than 330 grams) oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 130 | Providing and fixing 250 mm (weighing not less than 280 grams) oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 131 | Providing and fixing 200 mm (weighing not less than 240grams) oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 132 | Providing and fixing 125x64x1.90 mm IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
| 133 | Providing and fixing 100X58X1.90 mm IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
| 134 | Providing and fixing 75x47x1.80 mm IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
| 135 | Providing and fixing 50x37x1.50 mm IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
| 136 | Providing and fixing 125x64x2.50 mm IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : |
| 137 | Providing and fixing 100x60x2.50 mm IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : |
| 138 | Providing and fixing 75x50x2.50 mmIS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : |
| 139 | Providing and fixing 300x16x5 mm bright finished brass door latch with necessary screws etc. complete : |
| 140 | Providing and fixing 250x16x5 mm bright finished brass door latch with necessary screws etc. complete : |
| 141 | Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 142 | Providing and fixing bright finished brass night latch of approved quality including necessary screws etc. complete. |
| 143 | Providing and fixing 125mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. |
| 144 | Providing and fixing 100mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. |
| 145 | Providing and fixing 75mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. |
| 146 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 147 | Providing and fixing Triple strip vertical type magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. |
| 148 | Providing and fixing Double strip (horizontal type) magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. |
| 149 | Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer- in-charge. |
| 150 | Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately) |
| 151 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge (Extruded section profile size 48x40 mm) |
| 152 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge (Extruded section profile size 42x50 mm) |
| 153 | Providing and fixing 12 mm thick Fire retardant plywood conforming to IS: 5509 panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. |
| 154 | Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge |
| 155 | Providing and fixing cup board shutters with 25 mm thickWith decorative veneering on one side and commercial veneering on other side particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge. |
| 156 | Providing and fixing cup board shutters with 25 mm thickWith non decorative veneering on both sides particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge. |
| 157 | Providing and fixing aluminum U beading of required size to Pre-laminated/flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge. |
| 158 | Providing and fixing 200 x 19 x 1.9 mm stainless steel (SS-304 grade) friction hinges to the side/top hung uPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge. |
| 159 | Providing and fixing 250 x 19 x 1.9 mm stainless steel (SS-304 grade) friction hinges to the side/top hung uPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge. |
| 160 | Providing and fixing 300 x 19 x 1.9 mm stainless steel (SS-304 grade) friction hinges to the side/top hung uPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge. |
| 161 | Providing and fixing 350 x 19 x 1.9 mm stainless steel (SS-304 grade) friction hinges to the side/top hung uPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge. |
| 162 | Providing and fixing 400 x 19 x 1.9 mm stainless steel (SS-304 grade) friction hinges to the side/top hung uPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge. |
| 163 | Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete. |
| 164 | Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screws etc. complete. |
| 165 | Providing and fixing steel roller for uPVC sliding window with necessary screws etc. complete. |
| 166 | Providing and fixing steel roller for uPVC sliding door with necessary screws etc. complete. |
| 167 | Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. complete. |
| 168 | Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). |
| 169 | Providing and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge. |
| 170 | Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately) |
| 171 | Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc.complete as per direction of Engineer-in-charge. |
| 172 | Providing and fixing 200 mm stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. |
| 173 | Providing and fixing 2mm thick 16 to 19mm wide PVC edge binding tape of approved quality for cupboard/wardrobe shutters including necessary synthetic resin hot pressed to edges on binding machine etc. complete as per directions of Engineer- in-charge. |
| 174 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 175 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 176 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 177 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.(Using M.S. angels 40x40x6 mm for diagonal braces) |
| 178 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.(Using flats 30x6mm for diagonal braces and central cross piece) |
| 179 | Fixingwith 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. |
| 180 | Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 181 | Extra for providing and fixing steel beading of size 10 x 10 x 1.6 mm (box type), approved shape and section with screws instead of glazing clips and metal sash putty, in steel doors, windows, ventilators and composite units. |
| 182 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 183 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 184 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar with 1:6 (1cement : 6 coarse sand) including filling the joints with same mortar, with common burnt clay non modular bricks: |
| 185 | Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. |
| 186 | 40 mm thick with 20 mm nominal size stone aggregate Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 187 | 18 mm thick Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. |
| 188 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 189 | Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. |
| 190 | 25 mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 191 | Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm. |
| 192 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. |
| 193 | Crazy ceramic tile flooring, with under layer 12 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6 mm , mixing fibre @ 125 grams per 50 kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per 50 kg of cement, all complete as per direction of Engineer-in-charge. |
| 194 | Grouting the joints of flooring tiles Size of Tile 600x600 mmhaving joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 195 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 196 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 197 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. |
| 198 | Providing and laying vitrified floor tiles Size 600x600 mm(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. |
| 199 | Providing and laying Vitrified tiles in different sizes600x600 mm(thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 200 | Providing and laying flamed finish Granite stone flooring Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalentin required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : |
| 201 | Providing and laying Polished Granite stone flooring colour of Black, Cherry/Ruby Red or equivalent in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 202 | Providing and laying Polished Granite stone flooring Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red colour of Black, Cherry/Ruby Red or equivalent in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 203 | Providing 1 mm thick with zinc coating not less than 275 gm/ m² corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 204 | Providing .63 mm thick with zinc coating not less than 275 gm/m² ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. |
| 205 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 206 | Providing & fixing 0.56 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloyIS designation31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). |
| 207 | Providing and fixing Precoated/mill finish aluminium Ridges plain (500- 600mm) of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : |
| 208 | Providing 10 mm thick plaster of Paris (gypsum anhydrous) Curved surfaces ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): |
| 209 | 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 210 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 211 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 212 | 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) |
| 213 | 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 214 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 215 | Neat cement punning. |
| 216 | Distempering with 1st quality acrylic distemper (ready mixed) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : |
| 217 | Finishing walls for New work (Two or more coats applied @ 3.84 kg/10 sqm) with water proofing cement paint of required shade : |
| 218 | Finishing walls for New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) with Acrylic Smooth exterior paint of required shade : |
| 219 | Finishing walls for New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. |
| 220 | With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood |
| 221 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 222 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) |
| 223 | Painting (two or more coats) on 100mm diameter rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. |
| 224 | Painting (two or more coats) on 150mm diameter rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. |
| 225 | Painting Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 226 | Polishing on New wood work with ready mixed wax polish of approved brand and manufacture : |
| 227 | Lettering with black Japan paint of approved brand and manufacture |
| 228 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 229 | Distempering for Old work (one or more coats) with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour |
| 230 | Applying priming coats with water thinnable cement primer on wall surface having VOC content less than 50 grams/litre of approved brand and manufacture. |
| 231 | 6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge. |
| 232 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 233 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 234 | Polishing on Old wood work with ready made wax polish of approved brand and manufacture : |
| 235 | Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. |
| 236 | Finishing walls for Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface with Acrylic Smooth exterior paint of required shade : |
| 237 | Repairs to plaster of thickness 12 mm to 20 mm With cement mortar 1:4 (1 cement : 4 fine sand) in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 238 | Fixing Door chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 239 | Fixing Window chowkhats chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 240 | Fixing Clerestory window chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 241 | Fixing chowkhat in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on Each vertical member of door chowkhat and 2 nos on Each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener. |
| 242 | Making the opening For door/ window/ clerestory window in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. |
| 243 | Renewing Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) with putty and nails wherever necessary including racking out the old putty: |
| 244 | Renewing Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) with putty and nails wherever necessary including racking out the old putty: |
| 245 | Renewal of old putty of glass panes (length) |
| 246 | Refixing old glass panes with putty and nails |
| 247 | Fixing old glass panes with wooden fillets (excluding cost of fillets) |
| 248 | Renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer. |
| 249 | Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. |
| 250 | Providing and fixing 20 mm diameter. brass curtain rods ofwall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. |
| 251 | Providing and fixing 25 mm diameter. brass curtain rods ofwall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. |
| 252 | Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows. |
| 253 | Providing and fixing 150mm bright finished brass single acting spring hinges with necessary brass screws etc. complete : |
| 254 | Providing and fixing 125mm bright finished brass single acting spring hinges with necessary brass screws etc. complete : |
| 255 | Providing and fixing 100mm bright finished brass single acting spring hinges with necessary brass screws etc. complete : |
| 256 | Providing and fixing 150 mm bright finished brass double acting spring hinges with necessary brass screws etc. complete : |
| 257 | Providing and fixing 125 mm bright finished brass double acting spring hinges with necessary brass screws etc. complete : |
| 258 | Providing and fixing 100 mm bright finished brass double acting spring hinges with necessary brass screws etc. complete : |
| 259 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete |
| 260 | Providing and fixing 300 mm bright finished brass hard drawn hooks and eyes : |
| 261 | Providing and fixing 250 mm bright finished brass hard drawn hooks and eyes : |
| 262 | Providing and fixing 200 mm bright finished brass hard drawn hooks and eyes : |
| 263 | Providing and fixing 150 mm bright finished brass hard drawn hooks and eyes : |
| 264 | Providing and fixing 100 mm bright finished brass hard drawn hooks and eyes : |
| 265 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of Engineer-In-Charge. |
| 266 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 267 | Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consistfollowing operations:-(i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and otherdeposits.(ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. |
| 268 | Disconnecting damaged overhead/terrace PVC water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. |
| 269 | Providing & fixing Orissa pattern W.C Pan of size 580x440 mm White vitreous china water closet squatting pan (Indian type) along with\"S\" or \"P\" trap including dismantling of old WC seat and \"S\" or \"P\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. |
| 270 | DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. |
| 271 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 Metres lead) as per direction of Engineer-in-Charge.(a) Internal Work- Exposed on wall |
| 272 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 273 | Providing and laying in situ seven course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). |
| 274 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 Metres lead as per direction of Engineer- in-charge. |
| 275 | Demolishing Nominal cementconcrete 1:3:6 or richer mix (i/c equivalent design mix manually/ by mechanical means including disposal of material within 50 Metres lead as per direction of Engineer - in - charge. |
| 276 | Demolishing Nominal cementconcrete 1:4:8 or leaner mix (i/c equivalent design mix manually/ by mechanical means including disposal of material within 50 Metres lead as per direction of Engineer - in - charge. |
| 277 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 Metres lead as per direction of Engineer - in- charge. |
| 278 | Demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 Metres lead as per direction of Engineer-in-charge. |
| 279 | Removing mortar from bricks in From brick work in cement mortar and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): |
| 280 | Dismantling doors, windows and clerestory windows (steel or wood) shutter Of area 3 sq. Metres and below including chowkhats, architrave, holdfasts etc. complete and stacking within 50 Metres lead : |
| 281 | Dismantling doors, windows and clerestory windows (steel or wood) shutter Of area beyond 3 sq. Metres including chowkhats, architrave, holdfasts etc. complete and stacking within 50 Metres lead : |
| 282 | Taking out doors, windows and clerestory window shutters (steel or wood) Of area 3 sq. Metres and belowincluding stacking within 50 Metres lead : |
| 283 | Taking out doors, windows and clerestory window shutters (steel or wood) Of area beyond 3 sq. Metres including stacking within 50 Metres lead : |
| 284 | Dismantling For thickness of tiles 10 mm to 25 mmwork in floors and roofs laid in cement mortar including stacking material within 50 Metres lead. |
| 285 | Dismantling For thickness of tiles above 25 mm and up to 40 mmwork in floors and roofs laid in cement mortar including stacking material within 50 Metres lead. |
| 286 | Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 Metres lead : |
| 287 | Dismantling G.S. Sheetroofingincludingridges,hips,valleysandguttersetc., and stacking the material within 50 Metres lead of: |
| 288 | Dismantling Asbestos Cement sheetroofingincludingridges,hips,valleysandguttersetc., and stacking the material within 50 Metres lead of: |
| 289 | Dismantling tiled roofing with battens, boarding etc. complete includingstackingofserviceablematerialanddisposalofunserviceable material within 50 Metres lead. |
| 290 | Dismantlingbarbedwireorflexiblewireropeinfencingincludingmaking rolls and stacking within 50 Metres lead. |
| 291 | Dismantling40 mm thick precast concrete orstone slabsin walls, partition walls etc. including stacking within 50 Metres lead : |
| 292 | Dismantling40 mm to 75mmthick precast concrete orstone slabsin walls, partition walls etc. including stacking within 50 Metres lead : |
| 293 | Dismantling cement asbestos or other hard board ceiling or partition wallsincludingstackingofserviceablematerialsanddisposalof unserviceable materials within 50 Metres lead. |
| 294 | Dismantling of flushing cistern of all types(C.I./PVC/Vitrious China) includingstackingofusefulmaterialsnearthesiteanddisposalofunserviceable materials within 50 Metres lead. |
| 295 | Dismantling of 120 x 120 cm (outside to outside) cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 Metres lead : |
| 296 | Dismantling of 210 x 120 cm (outside to outside) cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 Metres lead : |
| 297 | Dismantling of320 x 120 cm (outside to outside) cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 Metres lead : |
| 298 | Dismantling old plaster or skirting raking out joints and cleaning the surfaceforplasterincludingdisposalofrubbishtothedumping ground within 50 Metres lead. |
| 299 | Dismantlingaluminium/Gypsumpartitions,doors,windows,fixed glazing and false ceiling including disposal of unserviceable material andstackingofserviceablematerialwithin50metersleadas directed by Engineer-in-charge. |
| 300 | Dismantling of flexible pavement (bituminous courses) by mechanical meansanddisposalofdismantledmaterialuptoaleadof1 kiloMetre, as per direction of Engineer-in-charge. |
| 301 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping groundorasapprovedbyEngineer-in-charge,beyond50minitial lead, for all leads including all lifts involved. |
| 302 | Cuttingroadandmakinggoodthesameincludingsupplyofextra quantities of materials i.e. aggregate, moorum screening, red bajri and labour (required.bituminous portion) |
| 303 | Paintingroadsurfacemarking for New work (Two or more coats) withadequatenosofcoatstogive uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning thesurfaceofalldirt,scales,oil,greaseandforeignmaterialetc. complete. |
| 304 | Paintingroadsurfacemarking for Old work (One or more coats) withadequatenosofcoatstogive uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning thesurfaceofalldirt,scales,oil,greaseandforeignmaterialetc. complete. |
| 305 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 Metre openable length ( total length 90 m), having 50 nos rounds per 6 Metre length, upto 3 m height of wall with existing angle iron \"Y\" shaped placed2.4m or3.00 mapart and with9horizontalR.B.T.reinforcedbarbedwire,studtiedwithG.I. staples and G.I. clips to retain horizontal, including necessary bolts orG.I.barbedwiretiedtoangleiron,allcompleteasperdirectionof Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52mmthick)andweight43.478gm/Metre(costofM.S.angle,C.C. blocks shall be paid separately) |
| 306 | Taking out existing CC interlocking paver blocks from footpath/ central verge,includingremovalofrubbishetc.,disposalofunserviceable materialtothedumpingground,forwhichpaymentshallbemade separately and stackingof serviceable materialwithin 50Metre lead as per direction of Engineer-in-Charge. |
| 307 | Layingoldcementcocreteinterlockingpaverblocksofanydesign/ shapelaidinrequiredline,level,curvature,colourandpatternover and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer- in-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 308 | Providingandlayingtactiletile(forvisionimpairedpersonsasper standards) of size 300x300x9.8mm having with water absorption less than0.5%andconformingtoIS:15622ofapprovedmakeinall colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4(1cement:4coarsesand)inallshapes&patternsincluding groutingthejointswithwhitecementmixedwithmatchingpigments etc. complete as per direction of Engineer-in-Charge. |
| 309 | Providing and laying 80mmthickC.C.paverblockofM-35gradewith approved colour design and pattern.factory made chamfered edge Cement Concrete paverblocksinfootpath,parks,lawns,drivewaysorlighttraffic parkingetc,ofrequiredstrength,thickness&size/shape,madeby tablevibratorymethodusingPUmould,laidinrequiredcolour& patternover50mmthickcompactedbedof sand,compactingand properembedding/layingofinterlockingpaverblocksintothesand beddinglayerthroughvibratorycompactionbyusingplatevibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. completeall as per direction of Engineer-in-Charge. |
| 310 | Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work,includingcostofcentering,shuttering,reinforcementof8mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neatcementpunningonfinishedsurface,properlyencasedonall edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads&lift,handlingatsiteetc.allcompleteasperdirectionof Engineer-in-Charge. |
| 311 | Providing andfixingWhiteVitreouschinaOrissapatternW.C.panofsize 580x440 mm with integral type foot rests waterclosetsquatting pan(Indian typeW.C. pan)with100mmsandcastIronPorStrap,10litrelowlevel whiteP.V.C.flushingcistern,includingflushpipe,withmanually controlleddevice(handlelever)conformingtoIS:7231,withall fittingsandfixturescomplete,includingcuttingandmakinggood the walls and floors wherever required: |
| 312 | Providing and fixing W.C. pan with ISI marked white solid plastic seat and lid white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard makeandmosquitoproofcouplingofapprovedmunicipaldesign complete,includingpaintingoffittingsandbrackets,cuttingand making good the walls and floors wherever required : |
| 313 | Providingandfixing Oneurinalbasinwith5litrewhiteP.V.C.automaticflushing cistern whitevitreouschinaflatbackorwallcorner typelippedfronturinalbasinof430x260x350mmand 340x410x265 mm sizes respectively with automatic flushing cistern withstandardflushpipeandC.P.brassspreaderswithbrass unions and G.I clamps complete, including painting of fittings and brackets,cuttingandmakinggoodthewallsandfloorswhereverrequired : |
| 314 | ProvidingandfixingWhiteVitreousChinaWashbasinsize550x400mm with a pair of 15 mm C.P. brass pillar taps washbasinwithC.I.brackets,15mmC.P. brasspillartaps,32mmC.P.brasswasteofstandardpattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 315 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brasssingleholebasinmixerofapprovedqualityandmake, including painting of fittings and brackets, cutting and making goodthe walls wherever required:- (a)White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 316 | Providingandfixingwhitevitreouschinapedestalforwashbasin completelyrecessedatthebackforthereceptionofpipesand fittings. |
| 317 | Providing and fixing 610x510 mm bowl depth 200 mm Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required (Kitchen sink without drain board) |
| 318 | Providing and fixing 610x460 mm bowl depth 200 mm Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required (Kitchen sink without drain board) |
| 319 | Providing and fixing 470x420 mm bowl depth 178 mmStainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required (Kitchen sink without drain board) |
| 320 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 Metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 321 | Providing and fixing 10 litre capacity - White P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 322 | Providing and fixing 10 litre (full flush) capacity-white controlled flush, low level cistern made of vitreous china with all fittings complete. |
| 323 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 324 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 325 | Providing and fixing15 mm nominal dia CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. |
| 326 | Providingandfixing 32mm diaFlexible pipe P.V.C.wastepipeforsinkorwashbasin including P.V.C. waste fittings complete. |
| 327 | Providingandfixing 40mm diaFlexible pipe P.V.C.wastepipeforsinkorwashbasin including P.V.C. waste fittings complete. |
| 328 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 329 | Providingandfixinginposition25mmdiametermosquitoproofcoupling of approved municipal design. |
| 330 | Providing and fixing 600x450 mm beveled edge mirror of superior glass(ofapprovedquality)completewith6mmthickhardboard ground fixed to wooden cleats with C.P. brass screws and washerscomplete. |
| 331 | Providing andfixing Circular shape 450 mm dia mirrorofsuperiorglass(ofapprovedquality)andofrequiredshapeandsizewithplasticmouldedframeof approved make and shade with 6 mm thick hard board backing : |
| 332 | Providing andfixing Rectangular shape 453x357 mmmirrorofsuperiorglass(ofapprovedquality)andofrequiredshapeandsizewithplasticmouldedframeof approved make and shade with 6 mm thick hard board backing : |
| 333 | Providing andfixing Oval shape 450x350 mm (outer dimensions) mirrorofsuperiorglass(ofapprovedquality) andofrequiredshapeandsizewithplasticmouldedframeof approved make and shade with 6 mm thick hard board backing : |
| 334 | Providing andfixing Rectangular shape 1500x450 mmmirrorofsuperiorglass(ofapprovedquality) andofrequiredshapeandsizewithplasticmouldedframeof approved make and shade with 6 mm thick hard board backing : |
| 335 | Providing andfixing 600x120x5 mmglass shelfwith edges round off, supported on anodised aluminium angle frame with C.P. brass bracketsandguardrailcompletefixedwith40mmlongscrews, rawl plugs etc., complete. |
| 336 | Providing and fixing C.P. brass toilet paper holder : |
| 337 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 338 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 339 | Providing and fixing PTMT 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 340 | Providing and fixing PTMT 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 341 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. |
| 342 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2\" BSP thread and shapes, weighing not less than 60 gms. |
| 343 | Providing and fixing 15 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work - Exposed on wall) |
| 344 | Providing and fixing 20 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work - Exposed on wall) |
| 345 | Providing and fixing 25 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work - Exposed on wall) |
| 346 | Providing and fixing 15 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work) |
| 347 | Providing and fixing 20 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work) |
| 348 | Providing and fixing 25 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work) |
| 349 | Providing and fixing 15 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) |
| 350 | Providing and fixing 20 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) |
| 351 | Providing and fixing 25mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) |
| 352 | Providing and fixing 32mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) |
| 353 | Providing and fixing 40mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) |
| 354 | Providing and fixing 50mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) |
| 355 | Providing and fixing 15 mm dia nominal bore G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.(Internal work - Exposed on wall) |
| 356 | Providing and fixing 20 mm dia nominal bore G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.(Internal work - Exposed on wall) |
| 357 | Providing and fixing 25 mm dia nominal bore G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.(Internal work - Exposed on wall) |
| 358 | Providing and fixing 15 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc.(External work) |
| 359 | Providing and fixing 20 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc.(External work) |
| 360 | Providing and fixing 25 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc.(External work) |
| 361 | Providing and fixing 32 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc.(External work) |
| 362 | Providing and fixing 40 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc.(External work) |
| 363 | Providing and fixing 50 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc.(External work) |
| 364 | Providing and fixing 25 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 365 | Providing and fixing 20 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 366 | Providing and fixing 32 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 367 | Providing and fixing 15 mm nominal bore ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 368 | Providing and fixing 20 mm nominal bore ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 369 | Providing and fixing 15mm norminal bore 45 cm length uplasticised PVC connection pipe with brass unions : |
| 370 | Providing and fixing 20mm norminal bore 45 cm length uplasticised PVC connection pipe with brass unions : |
| 371 | Providing and fixing 100 mm diameter C.P. brass shower rose with 15 or 20 mm inlet : |
| 372 | Providing and fixing 150 mm diameter C.P. brass shower rose with 15 or 20 mm inlet : |
| 373 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 374 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 375 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 376 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 377 | Providing and fixing 15mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 378 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 379 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 380 | Providing & fixing 15 mm nominal bore chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. |
| 381 | Making soak pit 2.5 m diameter 3.0 Metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. (With common burnt clay F.P.S. (non modular) bricks of class designation 7.5) |
| 382 | Providing and fixing Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) :(For fixed portion) |
| 383 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) :(For fixed portion) |
| 384 | Providing and fixing Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) :(For fixed portion) |
| 385 | Providing and fixing glazing With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 386 | Providing and fixing glazing With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 387 | Providing and fixing glazing With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 388 | Providing and fixing With stainless steel cover plate minimum 1.25 mm thicknessdouble action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. |
| 389 | Providing and fixing With brass cover plate minimum 1.25 mm thicknessdouble action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. |
| 390 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) |
| 391 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. (For the purpose of measurement the entire treated surface will be measured.) |
| 392 | Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or / and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square Metre of area respectively, second and fourth courses of roofing felt type 2 grade II (glass fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per sqm including preparation of surface but excluding grading, complete. |
| 393 | Providingand applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 394 | Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer(dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. |
| 395 | Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. |
| 396 | Providing and fixing With15mmthick fullyperforatedsquare/buttedgelightweightcalcium silicate panels/ tiles in position wall panelling at all heights with integral densified calcium silicatepanels/tilesofsize595x595mm,havingNRC(NoiseReductioncoefficient)of0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistanceof 100%,thermalconductivity<0.043W/mK asperASTM518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mmthickpressedsection(galvanizing@120gramspersqmincludingbothsides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor andceilingchannel sectionofsize50x32mfixedtothefloorandsoffitat600mm centersusing12mmdia,50mmlongwedgetypeexpandedzincalloy dashfastnerwith 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finallycalcium silicate non combustible panels/tiles are to bescrew fixed withselftapping panheadnickel coatedmild steelscrewsofsize13x3.2mmon tothisgridleavingan evengroove of1 mm betweenthepanels. The joints betweenthepanelsaretobedulyjointedandfinishedusingrecommendedjointing calcium silicate based compound and fiber joint tape roll 50mm wide(90 Metre )roll and twocoatsofprimersuitableforpanellingaspermanufacturer\"sspecificationasper direction of Engineer-in-Charge all complete. |
| 397 | Providing and fixing With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6 mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%,LightReflectance≥85%,ThermalConductivityk=0.052-0.057w/mK,Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T- Grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm)comprisingofmainTrunnersof15x32mmoflength3000mm,crossTofsize 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length600mm toform gridmoduleofsize 600x600mm suspendedfrom ceiling using galvanizedmildsteelitem(galvanised@80gsm)50mmlong8mmouterdiameterM-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L- shapeleveladjusterofsize85x25x2mm,spacedat1200mmcentretocentrealong main‘T’.Thesystemshouldrestonperipherywalls/partitionswiththehelpofGI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wallS.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carriedoutasperspecifications,drawingsandasperdirectionsoftheengineer-in- charge. |
| 398 | Providingandfixingharddrawnsteelwirefabricofsize75x25mmmeshorother suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of \"L\" shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge. |
| 399 | FillingofjointsbetweenRCCplinthbeam/floorslabandwallpanelofexternalwalls, toilet / bath room / wet areas walls on all floor and parapet wall over roof slab, stair case headroomatthetimeoferectionofGFRGpanelswithGroutRW/equivalentsealant compound after the erection of panelbeforethe infill of concrete in panel cavities and fine finish. This applies for all horizontal and vertical joints between GFRG wall and slab panels. |
| 400 | WaterproofingtreatmentofVerticaljoints(ofexternalsideandinternalside)between doorframe,window&ventilatorframes(onallfoursides)ofouterwalloverthe Zycosil/equivalent & Zycoprime/equivalent solution already applied (before the installation of door / window / ventilator frames in position) and fine finish with Grout RW/equivalent. |
| 401 | WaterproofingtreatmentofRCCsunshadewith Zycosil/equivalentwaterproofing Solution(1litreofZycosil/equivalent&20litresofwaterstirredfirst&2litresof Zycoprime/equivalent addedandstirred (total23litres))till itmeetsthesaturationlevel and testing as per RILEM or bywater drops test in which water drops do not absorb but drops remain or rolls. |
| 402 | In-filling / sealing of joint between RCC lintel cum sunshade and wall (on external side) in all floors by pushing in Grout RW/equivalentin paste form and coving 20 mm x 20 mm after applying a coat of Zycosil/equivalent & zycoprime/equivalent solution before cement plastering of top, bottom and sides of RCC sunshade. |
| 403 | Concreteworkwith40mmgaugebrickballastobtainedfrombreaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in CSI no. 5.01 includingcost of all labour, materials, T&P etc required for proper completion of work. |
| 404 | Brickworkinfoundation&plinthwitholddismantled bricks(suppliedby departmentfreeofcost)andcoarsesand mortarin1:6includingsupply ofallothermaterials,labour,removingmortar&cleaningofold&usedbricks,T&P etc complete. |
| 405 | Removal of cement mortar from dismantled bricks and stacking in countable position at place as directed by the Engineer in charge, includingcostofalllabourandT&Prequiredforpropercompletionofwork. |
| 406 | Supply and filling brick bat in soak pit including all labour,material and T&Petc complete. (for 01 soak pit) |
| 407 | Supplying & fixing 24 gauge annodized aluminium sheet of approved qualityincludingcutting,wastageandfixingthesameoverthewooden door shutters with nails with all material, labour and T&P |
| 408 | Providingandfixinginplaceafullheightstoragecabinet600mmdeep made with19 mm thick ISI marked plyborad, allinterior surfaces to finishedwithpastingof0.8mmthickmicaandallexteriorsurfacestobe finshed with pasting of 1 mm thick mica of texture and colour as approved byEngineerinChargeincludingalllabour,T&P,otheritemslike(butnot limitedto)fevicol,nailsscrews,higes,sliders,doorhandles,multipurpose lockofgodrejorequivalentrateetc.requiredforpropercompletionof works,tobemeasuredintermsoffrontareaonly. |
| 409 | Providingandfixinginplaceafullheightstoragecabinet450mmdeep made with19 mm thick ISI marked plyborad, allinterior surfaces to finishedwithpastingof0.8mmthickmicaandallexteriorsurfacestobe finshed with pasting of 1 mm thick mica of texture and colour as approved byEngineerinChargeincludingalllabour,T&P,otheritemslike(butnot limitedto)fevicol,nailsscrews,higes,sliders,doorhandles,multipurpose lockofgodrejorequivalentrateetc.requiredforpropercompletionof works, to be measured interms of front area only. |
| 410 | ProvidingandfixingfullheightPartitionwith02NOS12mmthickISI marked ply board, all surfaces to finished withf 1 mm thick mica of texture andcolourasapprovedbyEngineerinChargeandfixedinpolishedteak woodincludingalllabour,T&P,otheritemslike (butnot limitedto) fevicol, nailsscrews,hinges,sliders,doorhandles,multipurposelockofgodrejor equivalent rate etc. required for proper completion of works, to be measured interms of front area only |
| 411 | Providingandfixing12mmthickframelesstoughenedglassdoorshutter ofapprovedbrandandmanufacture,includingprovidingandfixingtop& bottom pivot & double acting hydraulic floor spring type fixing arrangement ,Doorhandle,lockandstopperetcandmakingnecessaryholesetc.for fixingrequireddoorfittings,allcompleteasperdirectionofEngineer-in- charge |
| 412 | Mild Steel or Iron work in heavy sizes such as trusses built up gates, door frames, record, racks roof work gates etc. wrought torequired form includingholesrivettingorweldingwherenecessary andalsofixingin properpositionandalignmentbutwhensteelistobeprovidedbythedepartment. |
| 413 | Supply and fixing 6mm thick polycarbonate multiwall sheet ,fixing in position with J or U bolts 10 mm. dia with G.I. Limpet & bitumen washers including supply of all materials, labour,wastage. and T&P etc. required for proper completion of the work. |
| 414 | Engraving lines in the plaster of the outer face wall verticallyand horizontally to display the surface as stone facing asdirected by the engineer in charge including labour and T&P etc.required for proper completion of the work (Add for extra labour and T&P etc. required for proper completion of the work (Add for extra labour to all items of plaster). |
| 415 | Providing (12x15) mm section groove in plasterincluding all material, labour andT&P etc. required for proper completion of the work. |
| 416 | 2.5 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC |
| 417 | As in item No. 12.04 above but 4.0 cm thickfloor in 1:1.5:3 concrete with out base concrete. |
| 418 | Painting letters & number over cable trench cover or other places with the help of stencils including painting of base of 150 mm. dia of one coat of primer and two coats of superior quality synthetic enamel paint size of letter to be 60 mm. x 10 mm. including cost of all materials labour and T&P etc. required for proper completion of the work including placing of Trench covers in required position |
| 419 | Dismantling ofdry B.O.E. Floor and proper stacking of dismantled bricks as per direction of E/C. up to 60 m lead. |
| 420 | Dismantling and re-laying of dry B.O.E. floor including cost of all labour and T&P required forproper completion of work.(labour rates only) |
| 421 | Pre-Construction anti-termite treatment, by creating a barrier under and around the columns pits, foundation trenches, under floors, junctions of Walls &floors, around the external periMetre of building, expansion joints, surrounding of pipes and conduits etc. (Plinth area of the building at ground floor only shall be measured as per I.S. 6313 (Part II 1981))with Eldrine emulsifiable 0.2% concentration or any other approved material such as Heptachlore or chlordance will be used. The consumption of emulsion shall be (i) Foundation and masonary @ 5 Ltrs/Sqm, (ii) Back fills in immediate contact of foundation@ 7.5 Ltrs. / Sqm, (iii) Top surface of Plinth filling @ 5 Ltrs / Sqm, ( iv) Junction of walls & floors @ 7.5 Ltrs / Sqm, (v) Soil along external periMetre of building @ 7.5 Ltrs / Sqm (vi) under apron of the building @ 5 Ltrs. /Sqm. The rates includes cost of all materials, labour, equipments, T&P complete. |
| 422 | Cleaning panes of glass with spirit of caustic soda including supply of all materials,labour and T&P etc.required for proper completion of the work. |
| 423 | Cleaning of septic tank including disposal of waste out side the UPPCL area as per direction of the Engineer-in-charge including cost of all labour,T&P etc.required for proper completion of the work. |
| 424 | Cleaning and opening of chocked W.C./ bath / kithchen pipe line including opening and refixing of chamber cover including washing etc. complete.(Analysis based on NBO - 11 25.020. |
| 425 | S/laying chicken mesh of (20 mm.)hexagonal heavy quality over roofs of joints of roof as per direction of the Engineer - in - charge. |
| 426 | Cleaning of existing pipe line of different dia. ranging from 4\" to 2\" dia. including digging trenches and refilling, opening of pipes, cleaning of pipes, cutting, threading, if required fixing and including making good the road, wall etc as directed by the engineer I/C. |
| 427 | Cleaning of existing water pipe line of different dia up to 2\" dia including digging trenches and refilling,opening and cleaning of pipes,cutting,threading,if required fixing and including making good the road and wall etc. as directed by the Engineer in charge. |
| 428 | Cleaning of R.C.C. over head tank up to capacity of one lac. Liters and chlorinating with blEaching power mixed to water as per direction of Engineer - in - charge complete. |
| 429 | Supply and mixing blEaching powder in over head tank as required or as directed by Engineer - in - charge. |
| 430 | Attending to petty maintenance service like plumbingservice,welder service, mansion service and carpenter servicerequired as below. (Job attending by one no. Plumber/welder/mason /carpenter with oneno. helper per hour or part of an hour.) |
| 431 | Cleaning and sweeping of roof of residence as and when requiredincluding uprooting of rank vegetation and disposal of thegarbage upto 50 M. |
| 432 | Providing and fixing of 200 mm dia PVC pipe of 6 Kg/sqcm with special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. |
| 433 | Providing and fixing of 150 mm dia PVC pipeof 6 Kg/sqcmwith special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. |
| 434 | Providing and laying 75 mm Dia. SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. |
| 435 | Providing and laying 90 mm Dia. SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. |
| 436 | Providing and laying 110 mm Dia. SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. |
| 437 | Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. |