| 1 | Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 metres lead :15.12.2 Of area beyond 3 sq. metres |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 metres lead :15.12.1 Of area 3 sq. metres and below |
| 3 | Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge., in kime mortar Sl 15.7.3 |
| 4 | Earthwork in excavation by manual means(hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.50m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead up to 50m and for all lift , as per direction og engineer in charge. 2.6.1 All kinds of soil DSR-2023 |
| 5 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying. curng, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 5.33.1 Al works upto plinth level 5.33.1.2 Concrete of M30 grade withminimum cement content of 350 kg /cum DSR-2023 |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level inal shapes and sizes in :6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) DSR-2023 |
| 7 | Dismantling old Plaster or skirting racking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground with in 50m leadas per Ch 17, Sl 15.56 |
| 8 | Dismantling RCC work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 m leadd as per direction of engineer in charge.Ch 17, Sl 15.3 |
| 9 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying. curng, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 5.33.2 Al works above plinth level up to floor vth level5.33.2.2 Concrete of M30 grade withminimum cement content of 350 kg /cum DSR-2023 |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more DSR-2023 |
| 11 | Structural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete Sl 10.1 DSR 2023 |
| 12 | Painting Steel/wood work with Deluxe Multi Surface Paint togive an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture 13.48.3 |
| 13 | CEMENT PLASTER (IN FINE SAND)13.1 12 mm cement plaster of mix : 13.1.1 1:4 (1 cement: 4 fine sand)DSR-2023 |
| 14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.Ch 15, Sl 13.80 |
| 15 | Distempering with 1st quality acrylic distemper, having VOC (VolatileOrganic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats whereverrequired, to achieve even shade and colour. 13.81.1 Two coats |
| 16 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primerDSR 2023 |
| 17 | 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)DSR-2023 |
| 18 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction withframe of 1st class hard wood and well matched teak 3 ply veneeringwith vertical grains or cross bands and face veneers on both faces ofshutters.9.20.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 19 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm allomplete.9.51.2 With 12 mm mild steel U beading |
| 20 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) 4.1.5 |
| 21 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate |
| 22 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. |
| 23 | specified by the manufacturer) with water absorption less than 0.08%and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting thejoints with white cement and matching pigments etc., complete.11.41.2 Size of Tile 600x600 mm |
| 24 | Painting with oil type wood preservative of approved brand and manufacture: 13.97.1 Old work (one or more coats) |
| 25 | Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work.13.115 |
| 26 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : 17.13.2 Orissa pattern W.C. pan of size 580x440 mmDSR-2023 |
| 27 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required 17.5.4 Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern |
| 28 | Providing and fixing one piece construction white vitreous chinasquatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVCflush pipe for back and front flush with standard spreader pipes withfittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floorsetc. wherever required :17.6.2 Range of two squatting plates with 5 litre P.V.C.automatic flushing cistern |
| 29 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps 17.7.3 |
| 30 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.17.31 |
| 31 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.18.48DSR-2023 |
| 32 | Providing and fixing C.P. brass angle valve for basin mixer andgeyser points of approved quality conforming to IS:8931. 18.53.1 15 mm dia nominal boreDSR-2023 |
| 33 | Providing and fixing C.P. brass bib cock of approved qualityconforming to IS:8931 :18.49.1 15 mm dia nominal boreDSR-2023 |
| 34 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etcDSR-2023 18.8.115 mm nominal dia Pipes |
| 35 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etcDSR-2023 18.8.220 mm nominal dia Pipes |
| 36 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 18.52.1 15 mm nominal bore |
| 37 | Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.12.41.2 110 mm diameter |
| 38 | Providing and fixing unplasticised -PVC pipe clips of approved designto unplasticised - PVC rain water pipes by means of 50x50x50 mmhard wood plugs, screwed with M.S. screws of required length,including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete12.43.2 110mm |
| 39 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion. 12.42.5 Bend 87.5° 12.42.5.2 110 mm bend |
| 40 | Providing & fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge, External work CH 25mm diaSI 18.9.3 |
| 41 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ |
| 42 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical Specification Clause 401. |
| 43 | Providing and laying of interlocking concrete block pavementhaving thickness 80mm as per drawings and technicalspecification Clause 1504. (Exclusive G.S.B) |