}

Bids Are Invited For 1 300014081 Sap- Elbow (Ptfe Lined) Size: 6 Dia, 90 Degree End Connections: Flanged, Flat Faced. Fixed Flange On One Side & Swivel (Loose) Flange On Other Side Elbow: Astm A234 Wpb Elbow Dimensions: As Per Ansi B16.9 Flange, Mumbai-Maharashtra

Department Of Fertilizers has published Bids Are Invited For 1 300014081 Sap- Elbow (Ptfe Lined) Size: 6 Dia, 90 Degree End Connections: Flanged, Flat Faced. Fixed Flange On One Side & Swivel (Loose) Flange On Other Side Elbow: Astm A234 Wpb Elbow Dimensions: As Per Ansi B16.9 Flange. Submission Date for this Tender is 14-08-2024. Tape Supply Tenders in Mumbai Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

44697965
Bids Are Invited For 1 300014081 Sap- Elbow (Ptfe Lined) Size: 6 Dia, 90 Degree End Connections: Flanged, Flat Faced. Fixed Flange On One Side & Swivel (Loose) Flange On Other Side Elbow: Astm A234 Wpb Elbow Dimensions: As Per Ansi B16.9 Flange
Tender
Indian
Maharashtra
Mumbai
14-08-2024

Tender Details

Bids Are Invited For 1 300014081 SAP- ELBOW (PTFE LINED) SIZE: 6 DIA, 90 DEGREE END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE & SWIVEL (LOOSE) FLANGE ON OTHER SIDE ELBOW: ASTM A234 WPB ELBOW DIMENSIONS: AS PER ANSI B16.9 FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. ELBOW CENTRE: 203 MM LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA : ASTM D -1457 TYPE III. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT . NOTE : 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES ( HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY.2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 2 PIECES 2 300089596 SAP- PIPE (PTFE LINED) SIZE: 6 (150 NB) END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE & SWIVEL (LOOSE) FLANGE ON OTHER SIDE PIPE:ASTM A-106 GR B SCH 40 PIPE LENGTH FACE TO FACE = 200 MM FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA : ASTM D -1457 TYPE III. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT NOTE : 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES ( HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY.2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 6 PIECES 3 300089597 SAP- PIPE (PTFE LINED) SIZE: 6 (150 NB) END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE & SWIVEL (LOOSE) FLANGE ON OTHER SIDE PIPE:ASTM A-106 GR B SCH 40 PIPE LENGTH FACE TO FACE = 1000 MM FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA : ASTM D -1457 TYPE III. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT NOTE : 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES ( HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY.2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 2 PIECES 4 300089598 PIPE 6IN DIA PTFE LINED. FLANGE TO FLANGE DISTANCE AFTER LINING 2000 MM PIPE MATERIAL : ASTM A 106 GR.B SCH 40 FLANGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. ONE SIDE FIX & OTHER SIDE LOOSE FLANGE LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS : 3 MM MINIMUM.FITTING : ASTM A234 WPB. PTFE/ PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 2 PIECES 5 300089599 SAP- PIPE (PTFE LINED) SIZE: 6 (150 NB) END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE & SWIVEL (LOOSE) FLANGE ON OTHER SIDE PIPE:ASTM A-106 GR B SCH 40 PIPE LENGTH FACE TO FACE = 500 MM FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA : ASTM D -1457 TYPE III. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT 4 PIECES NOTE : 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES ( HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY.2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 6 300089609 TEE EQUAL 6 X6 X6 IN PFA LINED(PERFLUORO ALKOXY) WITH FLAT FACED FIXED FNGES. FLANGE TO FLANGE DISTANCE FOR 6IN FLANGES AFTER LINING 406 MM . FLNGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS : 3 MM MINIMUM. FITTING : ASTM A234 WPB. PTFE/ PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 4 PIECES 7 300089614 ELBOW 90 DEGREE 4IN DIA PTFE LINED WITH FLAT FACED FIXED FLANGES. CENTERTO CENTER DISTANCE AFTER LINING 165 MM. FLANGE MATERIAL: AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING: PTFE / PFA LINING AS PER ASTM F- 1545-95. LINING THICKNESS: 3 MM MINIMUM. FITTING: ASTM A234 WPB. PTFE/ PFA: ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 4 PIECES 8 300089620 M.S. TEFLON LINED CONCENTRIC REDUCER. SIZE : 6X4 IN FLANGE TO FLANGE DISANCE AFTER LINING 230 MM FLANGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS : 3 MM MINIMUM. FITTING : ASTM A234 WPB. PTFE/ PFA : ASTM D - 1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 4 PIECES 9 300095664 SAP-BLIND FLANGE 6 DIA PFA LINED. FLANGE MATERIAL: AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 3 PIECES 10 300095665 SAP-BLIND FLANGE 4 DIA PFA LINED. FLANGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. PFA: ASTM D - 1457 TYPE III.TESTS: 15 KV SPARK TEST OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 3 PIECES 11 300095666 SAP-BLIND FLANGE 3 DIA PFA LINED. FLANGE MATERIAL: AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. PFA : ASTM D -1457 TYPE III.TESTS :15 KV SPARK TEST OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 3 PIECES 12 300095758 SAP-PIPE 4 DIA PTFE LINED. FLANGE TO FLANGE DISTANCE AFTER LINING 200 MM.PIPE MATERIAL: ASTM A 106 GR.B SCH 40.FLANGE MATERIAL: AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. ONE SIDE FIX & OTHER SIDE LOOSE FLANGE. LINING : PFA LINING AS PER ASTM F- 1545-95. LINING THICKNESS : 3 MM MINIMUM.FITTING : ASTM A234 WPB. PFA: ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST & 10 KG/CM2 HYDROTEST OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 10 PIECES 13 300089621 M.S. TEFLON LINED CONCENTRIC REDUCER. SIZE : 4X3 IN FLANGE TO FLANGE DISANCE AFTER LINING 180 MM FLANGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS : 3 MM MINIMUM. FITTING : ASTM A234 WPB. PTFE/ PFA : ASTM D - 1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 10 PIECES 14 300095759 FLANGED TEFLON LINED PIPE,SIZE: 4 NB x 500 LONG, TEFLON LINING THICKNESS: 3 MM MINIMUM, MOC: PIPE: ASTM A-106 GR B SCH 40 , FLANGE : ASTM A-105 B, 150 PSI , ANSI B 16.5 FLAT FACE, TEFLON LINING: ASTM F423-75, PRODUCT STANDARD: PS33-70,PAINTING: EXTERNAL SUFACES EPOXY PAINT WITH 40 MICRON PRIMER FOLLOWED BY 40 MICRON FINISH PAINT. PARTY SHALL SUBMIT TEST REPORTS/ CERTIFICATES (MINIMUM HYDROSTATIC ,ELECTROSTATIC TEST, MECHANICAL PROPERTYS OF LINING MATERIAL, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES), ALONG WITH THE SUPPLY. PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… 10 PIECES HSN CODE:……………………………………………………………………………………………… 15 300095760 FLANGED TEFLON LINED PIPE,SIZE: 4 NB x 1000 LONG, TEFLON LINING THICKNESS: 3 MM MINIMUM, MOC: PIPE: ASTM A-106 GR B SCH 40 , FLANGE : ASTM A-105 B, 150 PSI , ANSI B 16.5 FLAT FACE, TEFLON LINING: ASTM F423-75, PRODUCT STANDARD: PS33-70,PAINTING: EXTERNAL SUFACES EPOXY PAINT WITH 40 MICRON PRIMER FOLLOWED BY 40 MICRON FINISH PAINT. PARTY SHALL SUBMIT TEST REPORTS/ CERTIFICATES (MINIMUM HYDROSTATIC,ELECTROSTATIC TEST, MECHANICAL PROPERTYS OF LINING MATERIAL, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES), ALONG WITH THE SUPPLY. PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 10 PIECES 16 300095761 SAP-TEE EQUAL 4X4X4 PFA LINED(PERFLUORO ALKOXY) WITH FLAT FACED FIXED FLANGES. FLANGE TO FLANGE DISTANCE FOR 4 FLANGES AFTER LINING 330 MM . FLANGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS : 3 MM MINIMUM. FITTING : ASTM A234 WPB. PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 6 PIECES 17 300095762 SAP-ELBOW 90 DEGREE 4 DIA PTFE LINED WITH FLAT FACED FIXED FLANGES. CENTER TO CENTER DISTANCE AFTER LINING 165 MM. FLANGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PFA LINING AS PER ASTM F- 1545-95. LINING THICKNESS : 3 MM MINIMUM. FITTING : ASTM A234 WPB. PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 6 PIECES 18 300095763 SAP-REDUCING ELBOW 90 DEGREE 6/4” DIA PFA LINED WITH FLAT FACED FIXED FLANGES. CENTER TO CENTER DISTANCE AFTER LINING 203 MM FLANGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PFA LINING AS PER ASTM F- 1545- 95.LINING THICKNESS : 3 MM MINIMUM. FITTING : ASTM A234 WPB. PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST OFFERED MAKE:…………………………………………………………………………………… 6 PIECES HSN CODE:……………………………………………………………………………………………… 19 300095764 SAP- CONCENTRIC REDUCER (PTFE LINED) SIZE: 6 x 4 DIA, END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE & SWIVEL (LOOSE) FLANGE ON OTHER SIDE REDUCER: MATERIAL ASTM A234 WPB REDUCER DIMENSIONS: AS PER ANSI B16.9 FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. FACE TO FACE LENGTH AFTER LINING : 230 MM LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA : ASTM D -1457 TYPE III. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT NOTE : 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES ( HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY.2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 6 PIECES 20 300095765 SAP-ELBOW 90 DEGREE 6IN DIA PFA LINED WITH FLAT FACED FIXED FLANGES. CENTERTO CENTER DISTANCE AFTER LINING 203 MM. FLANGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS : 3 MM MINIMUM. FITTING : ASTM A234 WPB. PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 6 PIECES 21 300095766 SAP-ELBOW 90 DEGREE 8IN DIA PFA LINED WITH FLAT FACED FIXED FLANGES. CENTER TO CENTER DISTANCE AFTER LINING 229 MM. FLANGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS : 3 MM MINIMUM. FITTING : ASTM A234 WPB. PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 6 PIECES 22 300089604 FLANGED TEFLON LINED PIPE,SIZE: 3 NB x 1000 LONG, TEFLON LINING THICKNESS: 3 MM MINIMUM, MOC: PIPE: ASTM A-106 GR B SCH 40 , FLANGE : ASTM A-105 B, 150 PSI , ANSI B 16.5 FLAT FACE, TEFLON LINING: ASTM F423-75, PRODUCT STANDARD: PS33-70,PAINTING: EXTERNAL SUFACES 6 PIECES EPOXY PAINT WITH 40 MICRON PRIMER FOLLOWED BY 40 MICRON FINISH PAINT. PARTY SHALL SUBMIT TEST REPORTS/ CERTIFICATES (MINIMUM HYDROSTATIC ,ELECTROSTATIC TEST, MECHANICAL PROPERTYS OF LINING MATERIAL, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES), ALONG WITH THE SUPPLY. PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 23 300014088 FLANGED TEFLON LINED PIPE,SIZE: 3 NB x 500 LONG, TEFLON LINING THICKNESS: 3 MM MINIMUM, MOC: PIPE: ASTM A-106 GR B SCH 40 , FLANGE : ASTM A-105 B, 150 PSI , ANSI B 16.5 FLAT FACE, TEFLON LINING: ASTM F423-75, PRODUCT STANDARD: PS33-70,PAINTING: EXTERNAL SUFACES EPOXY PAINT WITH 40 MICRON PRIMER FOLLOWED BY 40 MICRON FINISH PAINT. PARTY SHALL SUBMIT TEST REPORTS/ CERTIFICATES (MINIMUM HYDROSTATIC,ELECTROSTATIC TEST, MECHANICAL PROPERTYS OF LINING MATERIAL, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES), ALONG WITH THE SUPPLY. PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 6 PIECES 24 300116792 FLANGED TEFLON LINED PIPE,SIZE: 4 NB x 1500 LONG, TEFLON LINING THICKNESS: 3 MM MINIMUM, MOC: PIPE: ASTM A-106 GR B SCH 40 , FLANGE : ASTM A-105 B, 150 PSI , ANSI B 16.5 FLAT FACE, TEFLON LINING: ASTM F423-75, PRODUCT STANDARD: PS33-70,PAINTING: EXTERNAL SUFACES EPOXY PAINT WITH 40 MICRON PRIMER FOLLOWED BY 40 MICRON FINISH PAINT. PARTY SHALL SUBMIT TEST REPORTS/ CERTIFICATES (MINIMUM HYDROSTATIC,ELECTROSTATIC TEST, MECHANICAL PROPERTYS OF LINING MATERIAL, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES), ALONG WITH THE SUPPLY. PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 6 PIECES 25 300116793 FLANGED TEFLON LINED PIPE,SIZE: 4 NB x 2000 LONG, TEFLON LINING THICKNESS: 3 MM MINIMUM, MOC: PIPE: ASTM A-106 GR B SCH 40 , FLANGE : ASTM A-105 B, 150 PSI , ANSI B 16.5 FLAT FACE, TEFLON LINING: ASTM F423-75, PRODUCT STANDARD: PS33-70,PAINTING: EXTERNAL SUFACES EPOXY PAINT WITH 40 MICRON PRIMER FOLLOWED BY 40 MICRON FINISH PAINT. PARTY SHALL SUBMIT TEST REPORTS/ CERTIFICATES (MINIMUM HYDROSTATIC,ELECTROSTATIC TEST, MECHANICAL PROPERTYS OF LINING MATERIAL, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES), ALONG WITH THE SUPPLY. PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 4 PIECES 26 300116794 FLANGED TEFLON LINED PIPE,SIZE: 4 NB x 2500 LONG, TEFLON LINING THICKNESS: 3 MM MINIMUM, MOC: PIPE: ASTM A-106 GR B SCH 40 , FLANGE : ASTM A-105 B,150 PSI,ANSI B 16.5 FLAT FACE, TEFLON LINING: ASTM F-423- 75, PRODUCT STANDARD: PS33-70,PAINTING: EXTERNAL SUFACES EPOXY PAINT WITH 40 MICRON PRIMER FOLLOWED BY 40 MICRON FINISH PAINT. PARTY SHALL SUBMIT TEST REPORTS/ CERTIFICATES (MINIMUM HYDROSTATIC,ELECTROSTATIC TEST, MECHANICAL PROPERTYS OF LINING MATERIAL, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES), ALONG WITH THE SUPPLY. PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 2 PIECES 27 300014089 FLANGED TEFLON LINED ELBOW,SIZE: 3 x SCH 40, 90 DEGREE,TEFLON LINING THICKNESS: 3MM MINIMUM, MOC: ELBOW: FABRICATED CARBON STEEL ASTM A 234 WITH ELBOW CENTRE 5.5 INCH, FLANGE : ASTM A-105 B, 150 PSI, ANSI B 16.5 FLAT FACE, TEFLON LINING: ASTM F-423-75 ,PRODUCT STANDARD: PS33- 70,PAINTING: EXTERNAL SUFACES EPOXY PAINT WITH 40 MICRON PRIMER FOLLOWED BY 40 MICRON FINISH PAINT. PARTY SHALL SUBMIT THE TEST REPORTS/ CERTIFICATES (MINIMUM HYDROSTATIC, ELECTROSTATIC TEST, MECHANICAL PROPERTYS OF LINING MATERIAL, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES), ALONG WITH THE SUPPLY. PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… 6 PIECES 28 300014090 FLANGED TEFLON LINED EQUAL TEE,SIZE: 3 x SCH 40, 90 DEGREE,TEFLON LINING THICKNESS: 3MM MINIMUM, MOC: TEE: FABRICATED CARBON STEEL ASTM A 234 WITH CENTRE AND HEIGHT OF TEE 4.5 INCH, FLANGE : ASTM A-105 B, 150 PSI, ANSI B 16.5 FLAT FACE, TEFLON LINING: ASTM F-423-75 ,PRODUCT STANDARD: PS33-70,PAINTING: EXTERNAL SUFACES EPOXY PAINT WITH 40 MICRON PRIMER FOLLOWED BY 40 MICRON FINISH PAINT. PARTY SHALL SUBMIT THE TEST REPORTS/ CERTIFICATES (MINIMUM HYDROSTATIC, ELECTROSTATIC TEST, MECHANICAL PROPERTYS OF LINING MATERIAL, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES), ALONG WITH THE SUPPLY. PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING. OFFERED MAKE:…………………………………………………………………………………… HSN CODE:……………………………………………………………………………………………… Total Quantity : 149

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail