| 1 | SCHEDULE ‘A’ PART - I (Constuction of Sentry Post) |
| 2 | Construction of Sentry Post (G+I) with RCC Columns, MS Truss with PPGI Sheet Roofing, Brick walls, PCC flooring, Plinth Protection with drain, Doors and Windows, Internal Electrifications, Duble Bunk Bed etc complete as per shown in Drawing (Drawing No. 6SECT/ENGR/42, Sheet No. 1/2 and 2/2) and as per direction of Engineer - in - Charge. |
| 3 | SCHEDULE ‘A’ PART - II (FOOTPATH) |
| 4 | Earth work in surfaceexcavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed in all kind of soil. |
| 5 | Providing and laying 63 mm to 45 mm size stone agg and compacting stone agg. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering, all work up to plinth 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 7 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with Ordinary cement without any pigment |
| 8 | Finishing walls with Premium Acrylic Smooth exterior paint on new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)with Silicone additives of required shade. |
| 9 | SCHEDULE ‘A’ PART - III (External Electrification) |
| 10 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core as per direction of Engineer - in - Charge. |
| 11 | Supply & fixingLED Flood light 120 W IP 65 to existing poles including bracket, nut bolts etc complete as per direction of Engineer - in - Charge. |
| 12 | Supply and fixing Steel TubularSwaged Poles type 410 SP-22 (8.5 meter long) complete with CI base plate and finial including earth cutting for foundation, cement concrete with 1:3:6 ( 1 Cement : 3 Coarse sand : 6 stone aggregates of 20mm nominal size) and form work etc complete as per direction of Engineer - in - Charge. |
| 13 | Supplying and fixing32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 14 | Supplying and fixing 6 ways, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |