| 1 | Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. |
| 2 | Supplying and filling in foundation, basement, etc with Crushed Stone sand filling in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 3 | Relaying of Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification. |
| 4 | Reconstruction of Brick work in cement mortar 1:5 (One cement and five sand) using using best quality II class Ground moulded chamber burnt bricks of size 9\" x 43/8\"x 2 3/4\"in for foundation andbasement and super structure,complying withstandard specification including curingetc complete as directed by the departmental officers. |
| 5 | For Foundation and Basement |
| 6 | Relaying of Plain Cement Concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. |
| 7 | Renewing and refixing by drilling holes and not by puching for Roofing with pre painted Galvalum sheet of0.47mm thick of best approved quality with required size with curved shape and white ridge sheet with necessary bolts and nuts bitumen washers, including cutting the sheet to the required size found necessary during execution etc., Complete complying with standard specifications. [The sheet should be got approved by the Engineer incharge before use on works] |
| 8 | Renewing the damaged 65mm dia GI pipe post for GI sheet roofing including labour charges for cutting, welding and fixing with MS flats (excluding cost of flat), etc., as directed by the departmental officers. |
| 9 | Renewing the damaged M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification. |
| 10 | Renewing the damaged GI pipe handrails for handicapped persons using 50mm dia GI pipe double handrail at a height of 800mm and 900mm from floor level with 25mm thick MS square rods as balusters embedded in the concrete and welded with pipe at 60cm centre to centre as shown in CA Job No. 9123 / 1 including cutting, welding, bending and fixing charges and applying one coat of red oxide primer for MS members as directed by the departmental officers |
| 11 | Renewing and refixing in position factory made Stainless Steel Flush Door Shutter 35mm thick using SS 304 Grade 1.6 mm thick, Stainless Sheets on both sides (Equivalent to IS 6911-04 Cr. 19, Ni 9) minimum 8-8.5% nickel and 18% chromium sourced from original stainless steel manufacturer with view panel size 30mm x 45mm made up of 6mm thick clear toughened glass fitted with double side adhesive tape and finished with dowconing silicon sealant, floor spring for each shutter, consealed tower bolt, suitable stainless steel locking arrangement and other necessary furniture fittings of approved quality. The vertical styles and other frame members and cross stiffeners shall be of same quality stainless steel box section of suitable size and thickness with proper core material as prescribed by the Departmental Officers. |
| 12 | Renewing and refixing in position aluminium anodised door with door shutter partly top 2/3 galzed and partly bottom 1/3 panelled and frame made out of box section 101.6x44.45x3.18mm thick at 2.319kg\m door shutter made out of box section 47.1x44.45x2.5mm at 1.202 kg\mfor vertical style and top, lock rail sections of size 50 x 44.45 x 2.50mm \"@ 1.292 Kg/m and bottom section 100.4x44.45x2.50mm at 1.974kg\m using clips of size 17.15x17.27x1.5mm at 0.176 kg\m with rubber beading, strike plate type handle ofsize 100x30x1.60mm at 0.988 kg\m on both sides, tower bolts, lock and top 2/3 portion with5.50 mm thick plain glass and bottom 1/3 portion with both side prelaminated board ( MDF ) 12mm thick for panel portion with one floor springs including cost of all materials labour power consumption required for fabrication, drilling holes in RCC columns floor slabs masonry wall wherever necessary with power drills to the required extent and make the same to original condition after fixing and as directed. All the aluminium sections are to be anodised with matt finish under electrically controlled condition in accordance with IS 1868-1962 for an average anodic flim thickness of 15 microns etc.,complete. The materials should be got approved by the Engineer incharge before use on works. The rate shall be inclusive of all materials labour for fixing transportation loading, unloading, and all other incidential charges. (Single Leaf Door) |
| 13 | Single Leaf Door |
| 14 | Renewing and refixing in position anodised aluminium natural colour matt finish sliding window in all floors with sliding arrangements and gutter arrangement so as to drain the water entering and made with extruded aluminium section of the sizes given below with necessary acessories such as rubber beading. best quality runner, lock, handle supplying and fixing 4mm thick plain glass including cost of all materials, labour power consumption required for fabrication, drilling holes in RCC column/ floor slab/masonry wall wherever necessary with power drills to the required extent and made same to original condition after fixing etc.,complete. The aluminium sections are to be anodized with matt finish under electrically controlled condition in accoradance with ISI 1868/1962 specification for an average anodic film thickness of not less than 15 microns All aluminium sections and furniture fittingsshould be got approved by the Engineer-in-charge before use on works. |
| 15 | Three Leaves |
| 16 | Gas Outlet Points: (Self sealing type - Single / DIN outlet pipe) with \"S\" type bracket made up of copper and the out let of non-interchangeable for other gas. The outlet points are brazed with brass bracket with self sealing valve (Stainless Steel) with all accessories and complete set and are covered by plastic cover duly colour coated as per specific gas and button cover etc., complete as directed by the Departmental Officers and as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. |
| 17 | Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection.The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V.The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. |
| 18 | 10mm OD 0.90mm thick copper pipe |
| 19 | 15mm OD 0.90mm Thick Copper Pipe |
| 20 | Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber \"O\" ring, tapion lap and etc.All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification. |
| 21 | 15mm Isolation Valve |
| 22 | Flow Meter made up of Brass with Humidifier Bottle Flow Meter should be back pressure compressed and should be accurate gas flow measurement with control range 0-13 litres per minute.It should meet strict permission and dumbling standard.The meter body should be made of brass materials.The humidifier bottle should be made of unbreakable polycorbonate material and auto cleavable at 134 degree centigrate.The rate includes flow meter and its accessories (silicon tube with mask). The cost of materials including transport, etc., complete as per standard specification and as directed by the Departmental Officer and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification. |
| 23 | Renewing the damaged flooring with plain ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 50mm thick. |
| 24 | Redadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 25 | Dadooing with printed design colour glazed tiles of size 300mm x 200mm x 6mm |
| 26 | Repainting two coats of old plastered wall surface with ready mixed plastic Interior emulsion paint of first class quality and of approved colour without primer including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 27 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 28 | SUB TOTAL |
| 29 | GST @ 18 % |