Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavation) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m - all kinds of soil. |
| 2 | Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50m - all kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m. |
| 4 | Extra for every additional lift of 1.5m or part there of in excavation / banking excavated or stacked materials - all kinds of soil. |
| 5 | Supplying and filling with gravel (excluding rock) in trenches , plinth, sides of foundations etc. In layers not exceeding 20 cm in depth consolidating each deposited layers by ramming and watering etc .complete including all lead and lift. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40mm nominal size) |
| 10 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacture\"s specification. |
| 11 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering , shuttering , finishing and reinforcement - All work upto plinth level 1:1.5:3 (1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 12 | Centering and shuttering including strutting , propping etc and removal of form for - foundations, footings, bases of columns etc for mass concrete |
| 13 | Centering and shuttering including strutting , propping etc and removal of form for - Walls (any thickness ) including attached pilasters , butteresses , plinth and string courses etc. |
| 14 | Centering and shuttering including strutting , propping etc and removal of form for - Suspended floors , roofs , landings , balconies and access platform |
| 15 | Centering and shuttering including strutting , propping etc and removal of form for - Lintels , beams , plinth beams , girders , bressumers and cantilevers. |
| 16 | Centering and shuttering including strutting , propping etc and removal of form for -Weather shade , Chajjas, corbels etc., including edges. |
| 17 | Providing , hoisting and fixing upto floor five level precast reinforced cement concrete in shelves including setting in cement mortar 1:3 (1 cement : 3 coarse sand) , cost of required centering , shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement , with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) |
| 18 | Providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning , fixing and finishing in cement mortar 1:3 ( 1 cement : 3 fine sand) etc. complete excluding plastering of the jambs, sills and soffits - 50mm thick. |
| 19 | Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (ISI BRAND OF APPROVED MAKE) Fe - 415 or more |
| 20 | Steel reinforcement for R.C.C.workincluding straightening , cutting , bending , placing in position and binding all complete above plinth level - Thermo - Mechanically Treated bars (ISI BRAND OF APPROVED MAKE) Fe - 415 or more. |
| 21 | Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 3.5 in foundation and plinth in - cement mortar 1:4 (1 cement : 4 coarse sand) |
| 22 | Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 3.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:4 ( 1 cement : 4 coarse sand). |
| 23 | Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 3.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 24 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundations and plinth in - cement mortar 1:4 (1 cement :4 coarse sand) |
| 25 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level upto floor V level - cement mortar 1:4 (1 cement : 4 coarse sand) |
| 26 | Providing and fixing M.S.grills of required pattern in frames of windows etc with M.S. flats , square or round bars etc. including priming coat with approved steel primer all complete - Fixed to steel windows by welding |
| 27 | Providing and fixing M.S.grills of required pattern in frames of windows etc with M.S. flats , square or round bars etc. including priming coat with approved steel primer all complete - Fixed to openings / wooden frames with rawl plugs screws etc |
| 28 | Providing and fixing ISI marked powder coating tower bolt black finish (Barrel type) with necessary screws etc.complete - 100x10mm |
| 29 | Providing and fixing of 65mm Godrej Navatal lock of 6 levers etc complete |
| 30 | Providing and fixing aluminium handles , ISI marked , anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade,with necessary screws etc, complete - 100 mm. |
| 31 | Providing and fixing factory made single extruded WPC (Wood Polymer composite) solid door / window / Ceosetory windows and Other frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 ( Suspension Grade) calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frames density of 750 kg / cum, screw withdrawal strength of 2200 N (Face) and1100 N (Edge), minimum compresssive strength of 58N/sq.mm, modulus of elasticity 900 N/sq.mm and resistance to spread of flame of class A category with property of being termite / borer proof, water / moisture proof and fire retardant and fixed in position of with M.S hold fast/lugs /SS dash fasteners of required dia and length complete as per direction of Engineer-in-charge (M.S hold fast/lugs or SS dash fastners shall be paid for separately) Note: For WPC solid door / window frames, minus 5mm tolerance in dimensions i.e. depth and width of profile shall be acceptable . Variation in profile dimension on plus side shall be acceptable but no extra payments on this account shall be made. - Frame size 45 x 70 mm. |
| 32 | Providing and fixing factory made singleextruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawl strength of 1800 N (Face) and 900 N (Edge), minimum compressive strength 50 N/sq.mm , modulus of elasticity 850 N/sq.mm and resistance to spread of flame of class A category with property of being temite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S.screws, all as per direction of Engineer-in- charge. (Note: Stainless steel butt hinges and necessary S.S.screws shall be paid separately) -30mm thick |
| 33 | Providing and fixing 1mm thick M.S.sheet door with frame of 40x40x6 mm angle iron and 3mm M.S.gusset plates at the junctions and corners , all necessary fittings complete, including applying a priming coat of approved steel primer - Using flats 30x6 mm for diagonal braces and central cross piece. |
| 34 | Steel work welded in built up sections / framed work , including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required – in gratings, frames, guard bar, ladder, railings, brackets,gates and similar works. |
| 35 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc .complete - 40mm thick with 20mm nominal size stone aggregate |
| 36 | Cement plaster skirting upto 30 cm height , with cement mortar 1:3 (1 cement : 3 coarse sand) , finished with a floating coat of neat cement - 18mm thick. |
| 37 | Providing and fixing glass strips in joints of terrazo / cement concrete floors - 40mm wide and 4mm thick. |
| 38 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) , of approved make (Jhonson / Asian / Somany / Nitco) in all colours, shades of size 300 x 450 mm as approved in skirting , risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement with pigment of matching shade complete – size 300x450 mm. |
| 39 | Providing and laying ceramic glazed floor tiles of size 300 x 300 mm (thickness to be specified by the manufacturer) , of commercial quality conforming to IS :15622, of approved make (Bell / Johnson / Regency / Somany / Naveen / Asian) in all colours, shades, except white , ivory, grey, fume red brown, laid on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand), including pointing the joints with white cement and matching pigments etc., complete |
| 40 | Providing and fixing PVC corner beading of required size to suit the thickness of the wall tile at the corner joints of dado works |
| 41 | Providing and laying fully vitrified floor tiles of size 600 x600 mm (thickeness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make (Nitco / Rak / Johnson / Asian ) in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) , including grouting the joints with white cement and matching pigments etc., complete - size of tile600x600mm - Commercial quality. |
| 42 | Providing and laying pressed clay tiles (as per approved pattern 18mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound , laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete |
| 43 | Lime concrete terracing on roofs of required thickness laid to fall with 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 lime putty : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with Parapet wall complete. |
| 44 | Making khurras 45x45cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20mm nominal size) over P.V.C. sheet 1m x1m x 400 micron , finished with 12 mm cement plaster 1:3 ( 1cement : 3 coarse sand) and a coat of neat cement , rounding the edges, making and finishing the outlet complete. |
| 45 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes – 110 mm diameter. |
| 46 | Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Single tee without door -110x110x110mm. |
| 47 | Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110 mm bend. |
| 48 | Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) - 110mm shoe. |
| 49 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and makinggood the wall etc., complete - 110mm |
| 50 | 12 mm cement plaster of mix 1:5 (1 cement : 5 fine sand) |
| 51 | Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster |
| 52 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:5 (1 cement : 5 fine sand) |
| 53 | 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand). |
| 54 | Finishing with deluxe multi surface paint system for interiors and exteriors using primer as per manufacture\"s specification - Two or more coats applied on walls @ 1.25 ltr / 10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm. |
| 55 | Painting with synthetic enamel paint of approved brand and manufacutre to give an even shade – Two or more coats on new work. |
| 56 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq.metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 metres lead – with cement mortar 1:4 (1 cement : 4fine sand) |
| 57 | Raking out joints in lime or cement mortar and preparing the surface for repointing or replastering, including disposal of rubbish to the dumping ground within 50 metres lead. |
| 58 | Flush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for flat tile bricks on top of mud phaska - with F.P.S. brick tiles. |
| 59 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 60 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade - One or more coats on old work. |
| 61 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead – nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). |
| 62 | Demolishing cement concrete manually / by mechanical means including disposal of unserviceable material within 50 metres lead.Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) |
| 63 | Demolishing R.C.C work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead. |
| 64 | Extra for scrapping , cleaning and straightening reinforcement from R.C.C. or R.B. work |
| 65 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - in cement mortar. |
| 66 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead - of area 3 sqm and below. |
| 67 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 metres span and 5 metres height including stacking the material within 50 metres lead – of sectional area 40 square centimetres and above |
| 68 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets ,welding etc.including dismembering and stacking within 50 metres lead |
| 69 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead - for thickness of tiles 10mm to 25mm. |
| 70 | Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 71 | Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead – thickness above 40mm upto 75mm. |
| 72 | Dismantling G.I.pipes (external work) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead- 15mm to 40mm nominal bore |
| 73 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 74 | Supplying fixing and commisioning of Suguna / Texmo / Sharp 2 HP monoblock pumpset slow speed single phase motor. The rate include the cost of pumpset , pumpset fixing in position and test run etc. complete |
| 75 | Acid cleaning for the existing Mosaic floors , glazed tiles work and removing the stains and decays to give a glassy look etc complete (The Acid used shall be 32% concentrated hydrochloric acid after taking on the precautionary measures). |
| 76 | Providing and fixing white vitreous china water closet squatting pan (Indian type) - Orissa pattern W.C.pan of size 580x440mm |
| 77 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors - 100mm inlet and 100mm outlet - sand cast iron S&S as per IS: 1729. |
| 78 | Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 20mm nominal outer dia pipes. |
| 79 | Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 25mm nominal outer dia pipes. |
| 80 | Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 32mm nominal outer dia pipes |
| 81 | Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 40mm nominal outer dia pipes. |
| 82 | Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings this included jointing of pipes & fittings with one step ASTM solvent cement , trenching refilling & testing of joints complete (External work) - 40 mm nominal outer dia pipes |
| 83 | Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 25mm nominal bore. |
| 84 | Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 32mm nominal bore |
| 85 | Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 40mm nominal bore. |
| 86 | Providing and fixing ball valve (brass) of approved quality , high or low pressure , with plastic floatscomplete - 20mm nominal bore. |
| 87 | Providing and fixing G.I.union in G.I.pipe including cutting and threading the pipe and making long screws etc. complete (New work) - 20 mm nominal bore |
| 88 | Providing and fixing G.I.union in G.I.pipe including cutting and threading the pipe and making long screws etc.complete (New work) - 25mm nominal bore |
| 89 | Providing and fixing G.I.union in G.I.pipe including cutting and threading the pipeand making long screws etc.complete (New work) - 32 mm nominal bore |
| 90 | Providing and fixing G.I.union in G.I.pipe including cutting and threading the pipe and making long screws etc.complete (New work) - 40 mm nominal bore. |
| 91 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked , with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank - Circular Tank. |
| 92 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931- 15 mm nominal bore |
| 93 | Providing and fixing PTMT bib cock of approved quality and colour - 15mm nominal bore, 90 mm long , weighing not less than 93 gms. |
| 94 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality - LD - 2.5 - rectangular shape 600x450 mm inernal dimensions |
| 95 | Providing and fixing on wall / column face unplasticed - PVC soil and waste pipes (type - B) conforming to IS : 13592- 1992 including jointing with seal ring conformation to IS : 5382 leaving 10mm gap for thermal expansion - single socked pipes -110mm diameter. |
| 96 | Providing and fixing on wall face / column face unplasticised - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735 – 1999 including jointing with seal ring conforming to IS :5382 leaving 10mm gap for thermal expansion - Single tee without door – 110 x110x110mm |
| 97 | Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 – 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend 110 mm. |
| 98 | Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 – 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend with door 110 mm. |
| 99 | Providing and fixing on wall / column face unplasticised - PVC soil and waste pipes (type B) conforming to IS :13592 – 1992 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single socketed pipes 75mm diameter. |
| 100 | Providing and fixing on wall / column face unplasticisd - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS :14735 -1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single tee with door - 75x75x75mm. |
| 101 | Providing and fixing on wall / column face unplasticisd - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS :14735 -1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Bend 75 mm. |
| 102 | Providing and fixing double scaffolding system (cup lock type ) on the exterior side of building / structure , upto 25 metre height, above ground level , including additional rows of scaffolding in steppedmanner as per requirement of site, made with 40mm dia M.S.tube, placed 1.5 metre centre to centre ,horizontal & vertical tubes joint with cup & lock system with M.S.Tubes, M.S.Tube Challis, M.S.Clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and / or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required , if feasible , for inspection of work at required locations with essential safety features for the workmen etc., complete. Note:(1) The elevational area of the scaffolding shall be measured for payment purpose.(2) The payment will be made once only for executtion of all items of such works |
| 103 | Chipping of unsound / weak concrete material from slabs , beams , columns etc. with manual Chisel and / or by standard power driven percussion type or of approved make including tapering of all edges , making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushesetc. and disposal of debris for all lead and lifts all complete - 50 mm average thickness. |
| 104 | Chipping of unsound / weak concrete material from slabs , beams , columns etc. with manual Chisel and / or by standard power driven percussion type or of approved make including tapering of all edges , making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete - 25 mm average thickness |
| 105 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams , lintels , columns and slabs to introduce steel bars for sunshades / balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement , all complete - Upto and including 12mm dia. |
| 106 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry , all complete – Bars upto 12mm diameter. |
| 107 | Cleaning of reinforcement from rust from the reinforcing bars to give it atotal rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry , all complete – Bars above 12mm diameter. |
| 108 | Providing , mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and complete in all respect - SBR Polymer ( @ 10% of cement weight ) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer. |
| 109 | Providing , mixing and applying SBR polymer (of approved make ) modified Cement mortar in proportion of 1:4 (1 cement : 4 graded coarse sand with polymer minimum 2% by wt.of cement used) as per specifications . Note: Measurement and Payment : The Pre-measurement of thickness shall be done just after the surface preparation is completed and payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and / or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N / Sqmm) - 25 mm average thickness in two layers. |
| 110 | Providing, mixing and applying SBR polymer (of approved make ) modified Cement mortar in proportion of 1:4 (1 cement : 4 graded coarse sand with polymer minimum 2% by wt.of cement used) as per specifications . Note: Measurement and Payment : The Pre-meaurement of thickness shall be done just after the surface preparation is completed and payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and / or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N / Sqmm) - 50 mm average thickness in two layers |
| 111 | Supply of Quarry rubbish including stacking to department gauge for premeasurement and spreading required thickness. |
| 112 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral stair cases upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse M sand : 3 graded stone aggregate 20mm nominal size) |
| 113 | Removing the existing cement paint / colour wash in the interior / exterior face using scrapping blade / wire brush and other proper tools upto floor five level to ensure the surface is free of loose particles, deposits, dusts etc., complete all as directed by the Engineer in charge. |
| 114 | Disposal of Moorum / building rubbish / similar unserviceable dismantled or waste material by mechanical transport including loading, transporting unloading within a lead of 10km for all lifts, complete all as per the directions of Engineer-in-charge. |
| 115 | Providing and fixing welded steel windows of standard rolled steel section, joints mitred and welded with 15x3 mm lugs, 10 cm long with steel lugs embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or wooden plugs and screws or with fixing clips or with fixing Bolts and nuts as required including fixing and welding of M.S. sheet of 1.20mm thick with M.S. flat beading welded around the panels welding of hinges, handles, tower bolts, hooks and eyes including the cost of applying a priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture etc. complete window side hung/top hung |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy