| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth; for pipe/ cables/ poles/foundation/sewage line and getting out in hard/dense soil complete all as specified and directed.. |
| 2 | All as per serial item No 1 above but exceeding 1.5meter but not exceeding 3.00 mtr in depth complete all as specified and directed.. |
| 3 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick, in hard/dense soil complete all as specified and directed. |
| 4 | Removal of surplus soil of distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed.. |
| 5 | M & L for PCC (1:4:8) type D-2 (40 mm graded stone aggregate) Cement in foundations,filling and mass concrete completed. |
| 6 | M & L for PCC (1:2:4) type B-2 (40 mm graded stone aggregate) Cement concrete in surface channels and drains with WPC 3% by weight of cementcomplete all specified and directed |
| 7 | Supply only Integrated water proofing compound |
| 8 | M&L precast solid block masonry of block 1:2:4 type B-1 wall exceeding 10 cm in width and built in cement mortar 1:6 complete all as specified and directed. |
| 9 | Rendering 20mm thick on fair faces of brick work or concrete surface in cement plaster 1:4, with WPC 3% by weight of cementfinished even and smooth without using extra cement completed all as specified and directed. |
| 10 | M&L for Reinforcement cement concrete type B1 1:2:4 in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like |
| 11 | S&F of flatFormwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping |
| 12 | M&L for flat Formwork to faces of Baffle walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all specified and directed |
| 13 | M&L for Reinforcement cement concrete type B1 1:2:4 with CM 1:4 in cover slabs (for man holes etc.)with plain faces complete all specified and directed |
| 14 | M&L for Reinforcement cement concrete type B1 1:2:4 using 20mm graded aggregatein Walls, retaining walls, basementwalls, ballast walls and the like;any thickness; above top of footings; including attachedpilaster and buttresses |
| 15 | M&L for Mild steelTMT bars 6mm to 8mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips. |
| 16 | S&F in PVC (SWR) pipes single socketed 110mm dia in any length with rubber ring joints fixed to walls |
| 17 | S&F in rep PVC (SWR) bends any radius, bend 110mm dia with access door |
| 18 | S&F in rep PVC (SWR) junction single, (single T) equal or unequal with access door110mm dia. |
| 19 | S&F in rep PVC (SWR) pipes single socketed 75mm dia in any length with rubber ring joints fixed to walls |
| 20 | M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 21 | S&F Mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for Iron stepsFe-410-W (Gde.E-250) quality-A orFe 290 (Gde -E-165)complete all specified and directed. |
| 22 | Material and labour for providing PCC (1:3:6) type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of bore 110 mm on after they are laid and tested complete all as specified and directed.. |
| 23 | M&L for Loose filling with broken bricks of gauge 80 to 150 mm in soakage pits, soakage wells |
| 24 | S&F PVC Vent cowl of 110 mm dia complete all specified and directed |
| 25 | S&F PVC Vent cowl of 75 mm dia complete all specified and directed |
| 26 | Dismantling of plain or corrugated steel sheeting any gauge, thickness as in roof covering complete all as specified and directed |
| 27 | S & F 0.63 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 complete, all as specified and directed. |
| 28 | S & F 0.80 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed. |
| 29 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) exc 1.50 Sqm but n exc 4.0 Sqm each including iron mongeries complete all as specified and directed. |
| 30 | Taking down Shutters of any description exc 1.0 sq. m but n exc 2.0 sq. m each. |
| 31 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) not exc 1.50 Sqm each including iron mongeries complete all as specified and directed. |
| 32 | Supply and fix 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete, all as specified and directed. |
| 33 | S& F for 30mm thick 2nd class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats. |
| 34 | S&F2nd class HW 30mm thick Glazed and skeleton shutters,divided into squared, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats. |
| 35 | S&F Framed work such as grills, gratings, etc with ends of bars houldered or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters,water tank staging and similar work confirming to Fe 290-0 Gde E-165 complete all as specified and as directed. |
| 36 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples |
| 37 | Supply only sheet glass 4mm thick ordinary quality and glazing with oil putty in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed. |
| 38 | Supply and fix MS butt hinges medium weight, cold rolled 100mm size complete all as specified and directed. |
| 39 | Supply and fix MS butt hinges medium weight, cold rolled 75mm size complete all as specified and directed. |
| 40 | Supply & fix Aluminium anodisedbarrel tower bolt 100 mm long of extruded section etc complete all as specified and directed. |
| 41 | Supply & fix Aluminium anodisedbarrel tower bolt 150 mm long of extruded section etc complete all as specified and directed. |
| 42 | Supply & fix ExtrudedAluminium anodised alloy handles fabricated type 150mm long complete all as specified and directed. |
| 43 | Supply & fix ExtrudedAluminium anodised alloy handles fabricated type 100mm long complete all as specified and directed. |
| 44 | Supply & fix aluminium alloy, anodised, sliding door bolts 250mm size with hasp, staple (bolt type) and fixing clips of sheets , cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy andfixed etc complete all as specified and directed. |
| 45 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but notbacking), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 46 | M&L for 25mm thickCement concrete type B-1, 1:2:4 (20mm graded aggregate) as in sub-base, sub-floors, floors and pavings etc complete all as specified. |
| 47 | M&L for screed bed or bedding layer of 15mm thick in cement mortar 1:6 for laying floor tiles etc all as specified. |
| 48 | M&L for joint free Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exc 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. (Note: colour and pattern of tile will be decided by GE/ Engr-in-charge. Contractor will brought the tiles only after approval of colour and pattern by GE/Engr-in-charge). |
| 49 | Dismantling wall and ceiling boards of any description including cover fillets complete all as specified and directed. |
| 50 | Supply and fixed 6 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to walls surface etc complete all as specified and directed. |
| 51 | Supply and fixed 4 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to walls surface etc complete all as specified and directed. |
| 52 | M & L for providing 4mm thick \"E\" Board in ceiling with galvanised iron snap frame of \"T\" section 24 x 38 x 0.70 mm wall/ceiling angle 25x25x0.35mm thick and hanging with 4mm GI wire all fixed arrangement will be done as per manufacturer instruction incl two coat of oil bound distemper anirected.d one coat of white wash complete all as specified and directed |
| 53 | Material & labour for 2nd class hardwood plain fillets, square, rectangular or triangular in section, wrought, secured with nails having sectional area not exc. 3 sqcm complete all as specified and directed |
| 54 | Dismantling Timber scantling with framed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq cmin section , in any position all as specified and directed. |
| 55 | M& L for cleansawn Second class hard-wood scantlings with framed work all as specified and directed. |
| 56 | Material and labour fornewplywood and wood based materialsurfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 57 | Material and labour for newly steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 58 | Material and labour for preparation of old steel surfaces of any description not otherwise described over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 59 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for all as specified and directed. |
| 60 | Material and labour for providing cement concrete 1:3:6 type C-2 using 40mm graded aggregate ) in plinth walls or retaining walls,drain walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) |
| 61 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground levelr all as specified and directed. |
| 62 | M&L for 75mm thick PCC type C-2, 1:3:6 (using 40mm graded stone agg) as in plinth protection complete all as specified and directed. |
| 63 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces with CM 1:4 finished even and smooth with out using extra cement complete all as specified. |
| 64 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces with CM 1:6 complete all as specified. |
| 65 | M&L for preparingplastered or unplasterd newly surface of any description with three coat of white wash on walls surfaces. |
| 66 | M&L for preparingplastered or unplasterd old surface of any description with two coat of white wash on walls surfaces. |
| 67 | Taking down copper/aluminium point wiring (light, Bell, fan, socket or power) complete and removing material to store for keeping in safe custody or for taking credit and making good the disturbed surfaces of wall /ceiling so as to match with the existing finishes complete all as specified and as directed. |
| 68 | M&L for Point wiring One Lightpoint controlled by one switch 6/5 Amp with PVC insulated and unsheathed multistranded FRLS copper conductor single core 1.5 Sqmm (nominalarea) cable using approved colour code as per IS drawing in and incl PVC casing and capping (ISI Mark) with all accessories including providing PVC board heavy duty incl providing plastic laminated bakelite sheet top coveralongwith copper earth wire PVC insulated & unsheathed multistranded(FRLS) copper conductor cableof size 1.5 Sqmm as continous earth wire connected to common earth and earth dolly complete all as specified. |
| 69 | One 3 pin Socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 70 | All as per serial item No 1 above but One 3 pin 6/5 Amp socket outlet controlled by one switch indep board. |
| 71 | M&L for Point wiringof Power point contolled by one 15 Amp switch independent with PVC insulated and unsheathed multistranded FRLS copper conductor single core 4.0 Sqmm (nominalarea) cable using approved colour code as per IS drawing in and incl PVC casing and capping(ISI Mark) with all accessories including providing PVC board heavy duty incl providing plastic laminated bakelite sheet top cover alongwith copper earth wire PVC insulated & unsheathed multistranded(FRLS) copper conductor cableof size 4.0 Sqmm as continous earth wire connected to common earth and erth dolly complete all as specified and as directed. |
| 72 | S&F Switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Voltscomplete all as specified & directed. |
| 73 | S&F Switch Socket Combination 2 in 1, 3 pin, 6 Amp piano flush type (ISI marked),240 Volts complete all as specified & directed. |
| 74 | S&F Switch Socket Combination 2 in 1, 3 pin, 16/15 Amp piano flush type (ISI marked),240 Volts complete all as specified & directed. |
| 75 | S&F Ceiling rose, surface bakelite, 65mm x 50mm ,two to three terminals complete all as specified & directed. |
| 76 | S&F MCB DB CRCA sheet powder coated SPN 8 way double door factory made suitable for incorporating MCB as out going connecting incoming and outgoing cables complete including taking down unserviceable one all as specified and as directed. |
| 77 | S&F MCB SPN having braking capacity 10 KA. 35 to 60 Amp, 240 volts C curve complete all as specified and as directed. |
| 78 | S&F MCB single pole having braking capacity 10 KA, 6 to 32 Amps 240 voltscomplete all as specified and as directed. |
| 79 | S&F Square shaped recess/suspended mounted environment friendly new generation asthetically ultra modern with high brightness LEDs as light source LED Flat panel, 36 watt, 2\"x2\"size, complete with driver and all accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cablecomplete including taking down unserviceable one all as specified and directed. Make : Crompton Greaves Cat Part No LCTLRNE-36-FO-CDL/WW or equivalent in Philips/Bajaj/Havells |
| 80 | S&F Wall mounted Mirror light LED fitting,10/11/14 Watt, 2 Feet long incl integrated electronic driver including dismantling taking down unsv fitting any type complete all as specified and directed. |
| 81 | S&F environmental friendly, ultra modern, energy saving, surface mounted decorative hexagon LED bulk head 10Wincluding connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable including taking down unserviceable one complete all as specified and directed.Make : Crompton Greaves - Cat Part No LBHP-10-CDL or equivalent in Philips / Bajaj / Havells |
| 82 | M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below notmal ground level, connected to galvanised earth lead wire 4.0mm dia by means of suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1,precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI wire protection pipe 25mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and as directed. Note:- The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 25mm GI pipe (light grade) for watering 25mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made. |
| 83 | Supply, installation testing & commissioning of solar Hot water system (Flat Plate Collector) based on indirect transfering of heat, thermosyphon circulation, non pressurised system of capacity 500 LPD with suitable electric backup including accessories including a sensor required for autocut as per manufactre design, and recommendation complete all as specified and directed.Note:- Rate of solar includs cost of electric backup, stainless hotwater tank with puf insulation and aluinium cladding 22 SWG, gauges, meters and protection device complete necessary arrangements but does not include the cost of cold water tank, cold water piping and hot water piping |
| 84 | S&F 3 layer 40 mm dia PP-R polypropylene random copolymer pipes SDR 7.4 (PN 16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. |
| 85 | Description all as per item srl No 84 here-in-before but of size 32 mm outer dia -ditto- |
| 86 | Description all as per item srl No 84 here-in-before but of size 25 mm outer dia -ditto- |
| 87 | Supply and fix 40 mm bore outer dia PPR gave valve brass insert complete all as specified and directed. |
| 88 | Supply and fix 32 mm bore outer dia PPR gave valve brass insert complete all as specified and directed. |
| 89 | Supply and fix 25 mm bore outer dia PPR gave valve brass insert complete all as specified and directed. |
| 90 | S&F 20 mm bib tap cast copper alloy with crutch or butterfly handle, fancy type screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified & as directed by engr-in-charge. |
| 91 | M&L for Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting existing 40 mm PPR pipe and making fusion joint etc. |
| 92 | S&F PVC water storage tanks of 1000 ltrs capacity rotational moulded (3 layered cylindrical vertical with closed top) ISI marked hoisted and fixed in position complete all as specified and directed. |
| 93 | M&L for Ball brass valves, high pressure, with polythene float and flynut complete of PPR pipe of size 40 mm dia, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. |
| 94 | M&L for 100 mm thick PCC 1:4:8 type D2 (20 mm graded stone aggregate) as in sub base flooring complete all as specified & directed. |
| 95 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particalsin trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shallbe measured 18 cm after punning. |
| 96 | Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection , laid flatie length of cable cover shall be laid across the cable, complete casted with PCC 1:2:4 Type B1 using 20mm graded crushed stone aggregateall as specified and directed |
| 97 | Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed. |
| 98 | S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed cable with multistranded copper conductor 4 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipealong with 4 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 4 sqmm earth wire and 2 Run of 4 sqmm cable shall be measured as one run.) |
| 99 | Supply and fixing, metal clad socket out let with MCB SPN 20 Amp, 240 V including sheet metal enclosure complete fixed on flat iron 32x6 mm or 2nd class hard wood wooden board including complete electrical connection by proper size of copper lugs complete all as specified. |
| 100 | M&L for PCC 1:3:6 Type C2 for mass concrete with 40 mm gradede coarse agreegete complete all as specified and as directed. |
| 101 | Materialand labour for rendering 10 mm thick cement plaster in cement mortar (1:4) on old face of brick work or concrete surface on walls complete all as specified and directed. |