Tender For Provision Of Klp (Ph-Iii Of Iii Phase) Under Ge (East) Agra.; 1 Sch A Part-I (Building Work)Note :This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5. 2 Total amount of Sch A Part II (Site clearance, Excavation and Earth work) 3 Total amount of Sch A Part III (Internal Water Supply) 4 Total amount of Sch A Part IV (Internal Electrification) 5 Total amount of Sch A Part V (Road, Path and Haed Standing) 6 Total amount of Sch A Part VI (Area Drainage) 7 Total amount of Sch A Part VII (Sewage Disposal) 8 Total amount of Sch A Part VIII (Rain Water Harvesting) 9 Total amount of Sch A Part IX (External Water Supply) 10 Total amount of Sch A Part X (External Electrification) 11 Total amount of Sch A Part XI (Conduit And Wiring For Tele/TV) 12 Total amount of Sch A Part XII (Lightening Protection) 13 Total amount of Sch A Part XIII (Earthing for Over Head Crane (EOT)) 14 Total amount of Sch A Part XIV (Dismantling/Demolition) 15 Sch A Part - XV(Miscellaneous Items)Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as Rs 0.00 under col.5 siginifies this fact only. 16 INTERNAL WATER SUPPLYS&F for two way Angle cock/ stop valve, fancy type, chromium plated, ISI marked with crutch or butterfly handle, screwed down, screwed for iron pipe and fixed to 15mm bore pipeand fixed complete all as specified and as directed. 17 S&F for 3 in 1 , CP wall mixture for mixing hot and cold water with overhead shower arrangement screwed down for iron pipe and and fixed for 15mm bore pipecomplete all as specified and as directed. 18 S&F Shower rose, brass, chromium plated 125 mm size with or without swivel joints, any size, including 450mm longh CP Shower arm fixing to steel pipe or union complete all as specified and directed. 19 S&F for health faucet with 1.50 m long cord,chromium plated suitable for 15mm dia pipe including fixing of brackets complete all as specified and as directed. 20 INTERNAL ELECTRIFICATIONM&L for point wiring complete forOne light/Fan/Exhaust fan/Bell pointcontrolled by one switch with PVC insulated and unsheathed FRLSH cable 1.5 sqmm (nominal area), ISI marked,multi stranded copperconductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , MS conduit in roof/floors, factory made pressed steelconcealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm PVC ,FRLSH cableinsulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories and complete all as specified and directed.Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost. 21 M&L for point wiring complete for One light pointcontrolled by two2-way switches with PVC insulated and unsheathed FRLSH cable1.5 sqmm (nominal area), ISI marked,multi stranded copperconductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , MS conduit in roof/floors, factory made pressed steelconcealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm PVC ,FRLSH cableinsulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories and all as specified and directed.complete .Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost. 22 M&L for point wiring complete for One 5 pin 5 Amp switch socket out let point on an independent board with PVC insulated and unsheathed FRLSH cable2.5 sqmm (nominal area), ISI marked,multi stranded copperconductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , MS conduit in roof/floors, factory made pressed steelconcealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 2.5 Sqmm PVC ,FRLSH cableinsulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories complete for max four nos socket outlets all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost. 23 M&L for point wiring complete with PVC insulated and unsheathed, FRLScable 2.5 sqmm (nominal area), ISI marked, stranded copperconductor single core including ISI marked 20mm dia PVC conduit concealed in wall and MS conduit in roof/floor slab & ceiling, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cablePVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all for max two nos socket outlets all as specified and directed. Note :- In case of roof/ceiling, heavy duty pipe shall be used without any extra cost. 24 S&F switch flush type 5/6 Amps single pole two way complete all as specified and dierected. 25 Supply and fix PVC / polycarbonate angle type holder suitable for LED Bulb & including LED bulb 9Watt, B22 AC 220V complete all as specified and dierected. 26 S&F LED batten Tube light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSIBin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed. 27 S&F LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSIBin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed. 28 S&F LED Building security light fitting with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <25 W (25/30W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 25/32 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed. 29 Supply and fix LED high bay light 120watt , 5000K/6500K , IP-65, IK-08, CRI >80, surge protection 4kv, driver efficiency >93% suitable for AC 220V 50 Hz, efficacy 125lm/watt optionally for DALI dimming for even further saving with toughned glass and mounting accessories, in built driver circular, square or retangular shape duly electrical connection with proper size of coppet wire complete all as specified. 30 Supply and fixingBLDC type Ceiling fan 1200 mm sweep five star rated single phase 230V AC, Min 220 CFMwith fan remote , five star rating and ISI marked alongwith steel down rod and connecting up the fan to ceiling roseincluding PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceilingfan motor not less than 0.5 mtr long for connection complete all as specified.Note:- Necessary Fan hook deemed to be included in item rate. 31 Supply and fixingExhaust Fan high quality mettalic body, resistant to colour change 300 mm sweep five star rated, 900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipefrom celling rose to exhaust fan motorcomplete all as specified and directed. 32 Supply and fixingExhaust Fan high quality mettalic body, resistant to colour change 450 mm sweep five star rated, min 900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipefrom celling rose to exhaust fan motorcomplete all as specified and directed.(for hanger only) 33 Supply and fixingAir Circulator Fan 600 mm sweep five star rated, 1400 RPM heavy duty metal body wall mounted type with bracket, aerodynamically designed & balanced blade 3 nos having double ball bearing ZZ (permanent lubricated) for longer life and minimum noise level, with approved colourcomplete including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipefrom celling rose to exhaust fan motorcomplete all as specified and directed. 34 S & F sheet metal enclosure single pole and neutral with two pin (for AC point) with earth terminal complete incl one no MCB SP 20/25 amp 10KA complete all as specified and directed. 35 S&F MCCB 4 pole 415 V AC 50 Hz fixed type 125 -160 amps with breaking capacity 16 KA complete all as specified and directed. 36 S&F MCB TPN 63 amp 4 P 415 V AC 50 Hz fixed type 63 amps with breaking capacity 10 KA complete complete all as specified and directed. 37 S&F MCCB VTPN DBdouble door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCBand with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed. 38 S&F MCCB TPN DBdouble door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCBand with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed.. 39 Supply and fixingMCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCBand with enclosure blank plates for unused way suitable for 4 wayall as specified and directed . 40 Supply and fixingMCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCBand with enclosure blank plates for unused way suitable for 8 way all as specified and directed . 41 Supply and fixingMCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCBand with enclosure blank plates for unused way suitable for 12 way ISI marked all as specified and directed . 42 S&F MCB SPN 32/40 Amps B series,10 KA 240 Volts ,AC ISI marked all as specified and directed . 43 S&F MCB 6-32 Amps single pole,240V/415 V, B Series, 50 Hz ,ACwith breaking capacity 10 KA , complete all as specified and directed. 44 M&L submain wiring with two single core 4 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 25 mm dia medium grade ISI marked concealed in wallsurface / ceiling for sub main connection including 4 sqmm FRLSH one single corePVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- Two single core 4 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit. 45 M&L submain wiring with two single core 6 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wallsurface / ceiling for sub main connection including one 6 sqmm FRLSH one single core PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- Two single core 6 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit. 46 M&L submain wiring with four single core 6 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 32mm dia mediumgrade concealed in wallsurface / ceiling for sub main connection including one 6 sqmm single core FRLSH PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- four single core 6 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit. 47 M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. belowground level connecting to galvanised earth lead wire 4.0 mm diaas earth lead upto 7.5 meters long connected by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe medium grade, 15 mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 40 x 40 x 3mm fixingwith 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt,20/ 40mm dia, medium grade, GI pipe as protection to GI wire 4.0 mm as main earthing lead from earth electrode to main TPN MCCBs DB/MCB DB/ test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing and testing complete all as specified and directed . 48 Taking down old U/S service connection/sub main wiring of any description of aluminium/copper conductor including batten/conduit/suspension wire etc and making good disturbed surface to match the existing surface. 49 Taking down old U/S DB with MCBs/Main switches/MCB SP/SPN of any description and in any position. 50 Taking down old U/S light fitting of any type and size complete all as directed 51 Taking down old U/S service wire of any type and size complete all as directed 52 ROAD, PATH AND HARD STANINGM&L for preparation of road surface and applying thermoplastic reflective paint for marking of minimum 2mm thick single coat as a centre line or edge line etc. road marking of painting lines, dashes,arrows,letters etc on roads pavement and the like exc 10cm wide with road marking paint,white or golden yellow etc complete all as per manufacture instruction and specified and directed 53 S&Fin repair 60 cm dia 2.5 thick and over convex mirror fixed with6.75 feet longpole with coping of size 30 cm x 30 cm x45 cm size including50x50x6mm thick size T- Section including earth work and cement concrete 1:2:4 Type B-1 (using 20mm graded stone aggregate)and all necessary fitting and fixures to fix the convex mirror complete all as specified and directed. 54 SEWAGEDISPOSAL Construction of RCC Septic tank conventional typefor 50 users designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole opening with cover connection etc complete with effective depth of 1.5 m and overall depth of 3 m complete all as specified and directed. 55 Construction of RCC Septic tank conventional typefor 100 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole opening with cover connection etc complete with effective depth of 1.5 m and overall depth of 3 m complete all as specified and directed. 56 Construction of RCC Septic tank conventional typefor 150 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole opening with cover connection etc complete with effective depth of 1.5 m and overall depth of 3 m complete all as specified and directed. 57 Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 m dia x 3.00 m effective depth complete all as specified and directed. 58 Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40 m dia x 3.00 m effective depth complete all as specified and directed. 59 Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3 m dia x 3.00 m effective depth complete all as specified and directed. 60 Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3 m dia x 4.50 m effective depth complete all as specified and directed. 61 RAINWATER HARVESTINGSupply and filling 100mm to 200mm sixe boulder for recharge pit from Lal gun quarry complete all as specified and directed. 62 Supply and filling 40mm to 63mm sixe boulder for recharge pit from Lal gun quarry complete all as specified and directed. 63 Supply and filling coarse sand for recharge pit coplete all as specified and directed. 64 M & L pea Gravel packingof size06 to 10mm for trailbore of size to be designed by the contractor natural shape brought direct from river bed and packing around the casing pipe to entire depth upto ground level complete all as specified and directed. 65 S&F 100mm bore PVC U type air bend coplete all as specified and directed. 66 Drilling bore well of 200mm dia upto 60mtr dedpth in any type of soil for lowering to the PVC pipe complete all as specified and directed. 67 M&L plain PVC Pipe, 100 mm dia bore as per IS 12818 including lowering and jointing complete all as specified and directed. 68 M&L PVC slotted 110mm bore single socketed (6mtr lenth) of pressure 6 kg/sqcm and lower to boreas per IS 12818 including all fitting complete all as specified and directed. 69 S&F PVC bail plug for 110mm outer dia complete all as specified and directed. 70 S&F PVC well cap for 110mm outer dia complete all as specified and directed. 71 Development of bore well by air compressor having capacity 450/150 CFM/PSI complete all as specified and directed. 72 S&F PVC pipe 160mm outer dia , single socketed of pressure 6 kg/sqcm in any length with rubber ring joints laid in trenches or in floor including all fitting completeall as specified and directed. 73 S&F stainless steel sheet for screen chamber of thickness 16 gauge with rounded punched holes of 15 mm dia and area of each screen chamber not exceeding1.00 Sqm fixed with angle grooves and removeable with one end (top end) having additional thickness for holding for cleaning purpose complete all as specified and directed. 74 S&F stainless steel grating to cover the PVC pipe 110 mm outer dia with made of 8 mm dia SS bar(grade 504) with coller and aperture 50mm centre to centrecomplete all as specified and directed. 75 S&F for 150mm PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors with cement concrete bed of PCC (1:4:8) type D-2 using 40mm graded stone aggregate complete all as specified and directed. 76 S&F for 200mm PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors with cement concrete bed of PCC (1:4:8) type D-2 using 40mm graded stone aggregate complete all as specified and directed. 77 EXTERNAL WATER SUPPLY Supply, laying and jointing of ductile iron pipes with spigot and socket ends suitable for push on rubber tightened joint centrifugally cast, class(K-7), Inner side cement lining and outer side metallic zinc/black bitumen coating and any length , laid in trenches of 150 mm bore pipe including push on rubber (EODM) ring with ISI marked complete all as specified and directed. Note : (i) Please note cost of rubber tightened joints to be included in the above quoted rate. (ii) Excavation and earth work shall be masured and paid under respective schedule 78 Supply, laying and jointing of ductile iron pipes with spigot and socket ends suitable for push on rubber tightened joint centrifugally cast, class(K-7), Inner side cement lining and outer side metallic zinc/black bitumen coating and any length , laid in trenches of 100 mm bore pipe including push on rubber (EODM) ring with ISI marked complete all as specified and directed. Note : (i) Please note cost of rubber tightened joints to be included in the above quoted rate. (ii) Excavation and earth work shall be masured and paid under respective schedule 79 Supply and fixing of 150mm cast iron air release valve with drilled flanged ends, pressure rating (PN-1) and tamper proof with two air outlets with nuts, bolts and washer and conforming to IS-14845 complete all as specified and directed. 80 Supply and fixing of 100mm cast iron air release valve with drilled flanged ends, pressure rating (PN-1) and tamper proof with two air outlets with nuts, bolts and washer and conforming to IS-14845 complete all as specified and directed. 81 Supply and fix Sluice valve 150mm bore both ends flanged class PN 1.0 with stainless steel spindle and 01 No hand wheel including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer of suitable size necessary including testing complete all as specified and directed. 82 Supply and fix Sluice valve 80mm bore both ends flanged class PN 1.0 with stainless steel spindle and 01 No hand wheel including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer of suitable size necessary including testing complete all as specified and directed. 83 Supply and fix Sluice valve 50mm bore both ends flanged class PN 1.0 with stainless steel spindle and 01 No hand wheel including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer of suitable size necessary including testing complete all as specified and directed. 84 Taking up or down 80mm bore GI water tubing and connection for re-routing from trenches/floor etc complete all as specified and directed. 85 Laying only old GI water tubing 80mm bore in trenches/ floor including new GI fitting as directed.Note: GI water tubing obtained from items here-in-before. 86 Construction of fly ash brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work,100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4)on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed. 87 EXTERNAL ELECTRIC SUPPLY :Supply, Installation, Testing and commissioning of transformer outdoor type step down transformer 11 kV/0.433 kV energy efficient, plint mounted,AC 3 phase 50 Hz, 100 KVA capacity, core type copper wound, on HV & LV coil immerse, naturally cooled, Oil Natural-Air Natural (ONAN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-II with neutral brought out on secondary side (LV) and having 7 step tapping at +/ 2.5% of each step (+5% to 10%) on HV side to be charged by means of hand operated OFF load tap change gear, the maximum temperature rise should not exceeds 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on and ambient temp of 40 degree celcius the transformer shall be in accordance with IS-1180 (Part-I) 2014 latest amendment No 1,2,3 & 4 (Level-2) including cable terminationbox for transformer connection both HV and LV side and comprises of the following : -(a)One cable end termnation box on HT/LT (both side) consisting of suitable Nos of porcelain bushing with copper rods complete with nuts, bolts and washers. (b)Oil conservator with filter type drain valve and oil level gauge. (c)De-hydration breather wih filter fill of dehydrating agent (Silica gel). (d)Explosive vent, thermometer pocket on tank cover, oil drain filter valve, lifting lugs / hoks, oil filer hole with cap / plug with connection plate complte, air release valve plug and four Nos plain cast steel detchable roller. (e)One No. 100 mm, dial type thermometer, vapour pressure type having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator. (f)Two earthing terminal on tank cover to faciliate fixing of 50 X 6 mm galvanized iron eart strip for earthing of body.Note : PCC foundation of size 2.5 mtr x 2.5 mtr x 1.5 mtr heightshould be as per TD-699 Sheet 1/1 related TD drgs, fencing and gate around the transformer area.Cost of PCC fdn and fencing included in the quoted rates) 88 Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 of 11 mtr long, all as specified and shown on drawings including the followings:-(a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base.(e)Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block.(f) Painting of coping shall be cement base paint complete all as directed.(g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed.Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately. 89 M&L for drilling suitable dia horizontal bore holes for insertion/ laying of upto 110mm bore HDPE pipe of any description below/under existing road surfaces/apron /floors etc with using mechanical and / or manual devices as required at site including making good the disturbed surfaces to match with the existing strata after laying pipes complete all as specified and directed. NOTE :(i)Pipes shall be laid minimum 60 cm below/under existing road surfaces/ apron /floors etc. (ii) Equipment,tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor without any extra cost to the Govt. 90 Supply ,installation, testing and commissioningof canopy headed HT 11K volt grade, 3 phase , AC, 50 cycle, feeder pillar box, factory made CPRI approved and as per IS-61439 outdoor pedestal type double door, IP 65 protection with incoming and outgoing cable entry glands fabricated out of 3.15 mm thick CRCAsheet with powder coatedpaintingin side and outside of approved shade ,locking arrangementwith 02 Nos 19mm dia lock of make Godrej with keys, two earthy terminal suitable cable gland for all incoming and outgoing cable grouting of feeder pillar box 30 cm above ground level by providing 90 cm long angle iron of size 50x50x6 mm welded on all the four comers embedded in PCC (1:2:4) using 20 mm graded stone agg upto 30 CM deep and 45 CM above from normal ground levelcomplete all as specified and directedincl the following components:-(a) The panel will be havingaluminium bus bar of size 50x10mm duly insulated with heat shrinkable sleeves with porcelain HT long post insulator 11 KV, Complete all as specified and directed. 91 Supply and laying HDPE pipe double wall medium class, ISI Marked corrugated as in cable protection pipe of outer dia 110 mm including all fittings complete all as specified and directed. 92 Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 of 9 mtr long, all as specified and shown on drawings including the followings:-(a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base.(e)Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block.(f) Painting of coping shall be cement base paint complete all as directed.(g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed.Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately. 93 Material and labour Cable Route indicator ISI marked showing MES HT U/G 11KVsize 1m height X 60cm wide X 10cm thick tapered on top)and route of cable with arrow (Embossed or engraved) made of RCC 1:2:4type B-0 (using 12.5 mm graded stone aggregate) 50 mm thick reinforced with 8 mm dia TMT bar at the rate of 100 mm centre to centre in suitable shape and size 60 cm x 30 cm x 50 mm thickfixed in PCC block 1:2:4 type B-2 (using 40mm graded aggregate) (size of block 30cmx 30x15cm)of 30 cm below ground level and 30cm above ground to show clear indication of cable including painting the complete slab with red paint and marking the engraved/embosed letters/arrow with white paint complete all as directed.Note :-Quoted rate shall be deemed to included the cost of excavation, returning, filling and removal of excavated earth upto a distance of not exceeding 30 mtr complete. 94 Material and labour Cable Route indicator ISI markedshowing MES LT U/G 1.1KVsize 1m height X 60cm wide X 10cm thick tapered on top)and route of cable with arrow (Embossed or engraved) made of RCC 1:2:4type B-0 (using 12.5 mm graded stone aggregate) 50 mm thick reinforced with 8 mm dia TMT bar at the rate of 100 mm centre to centre in suitable shape and size 60 cm x 30 cm x 50 mm thickfixed in PCC block 1:2:4 type B-2 (using 40mm graded aggregate) (size of block 30cmx 30x15cm)of 30 cm below ground level and 30cm above ground to show clear indication of cable including painting the complete slab with red paint and marking the engraved/embosed letters/arrow with white paint complete all as directed.Note :-Quoted rate shall be deemed to included the cost of excavation, returning, filling and removal of excavated earth upto a distance of not exceeding 30 mtr complete. 95 Supply and fixing LED street light fitting 70 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection,fixed to pole or wall of building with and including suitableBracket made out of40 mm dia GIlightgrade pipe, 1.20 m long bent to shape by cutting & weldingas required & directed and fixed withtwo Nos of FI clamps 50x6 mm to be tightened with suitable size of bolts, nut and washers and including painted withtwo coat of aluminium paint over a coat of red oxide primer, and including connecting the fittingto electric sourcewith & including twin twisted copper flexible wire of size 1.5 sqmm three core with suitable size flexible PVC conduitincluding all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. 96 Supply and fix junction/looping box polycarbonate alongwith clamps complete,pole mounted right hinged looping box of size 155 x 210 x 92 with MCB SP 6 Amp capacity, copper bus bar-4 Nos fixed on ebonite insulator suitable capacity for 3 phase and neutral complete with necessary MS clamp made of 25 x3 mm MS flat, bolts, Nuts, washers etc for fixing to steel tubular /rail pole includingall accessories.complete all as specified and directed. 97 Supply and fix street light timer switchwith voltage mounting device enclcosed in SMC Enclosure for automatic and manual switching of street light based on LUX level of natural light , The sensor along with suitable power contactor MCB support terminal shell be housed in enclosure complete made out of anti rust/ shock proof/ termite proof/ confirming to IP 54 suitable for 5-8 KW (40 Amp) load compete allas specified and directed. 98 Supply and fix, New generation, IP 65 LED post-top lantern 40 W, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. 230 watt volts, AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, Clear Cover offers bright illumination for different applicationscomplete all as specified and as directed. 99 Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel strip 32x6 mm as earth lead soldered and rivetedto earth plate by means of nuts, bolts, check nuts & washers, of galvanizediron or steelwith connected to test point and testing on completion including 40 mm pipemedium grade for earth leadprotection from earth point to earth plate, including provnadequate quantity of charcoal dust mixed with35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth platewith 20mm bore GI Pipe medium grade for watering,GI check nut, funnel and wire meshwith and includingall necessary excavation& earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor. 100 Supply, install, testand commissioning of Outdoor cubical type LT feeder pillar box, factory made, dust and vermin proof, double door (front and back openable by keyy from both side fancy locks), cubical and duly fully compartmentalized and separation from each control switchgear, 415 volts, AC, 50 Hz, IP-54, fabricated with 3.15 mm thick CRCA sheet for outer side and 2mm thick inside complete with and including mounted on angle iron frame stand of size 50 x 50 x 6 mm thick 50 cm long leg, grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate), spray painted inside and outside, having seven tank treatment process for powder coating, enclosed bus bar chamber with aluminium bus bar (04 Nos)of rating not less than 1.5 times of incomming , mounted on PVC insulators, electric connection complete withfrom MCCB to main bus bar, cable glands, thimble complete with and including openable shutters butt hinged, locking arrangement including PCC work, excavation & earth work complete and comprising supply and fixforfollowing etc complete all as specified and as directed:- Incoming : (a) Aluminium busbar chamber comprising 4 Nos strip PVC insulatedwith current capacity 400 Ampwith stand heat shrinkable sleeking alongwith shrouds for joints, PVC sheathed with colour coding(b)Incommer MCCB, 4 polehaving current ratings 200 Amps, AC 415 Volts, withIcu= 25 KA ,Ics = 100% ofIcu,with thermal magnetic release, complete with spreader links-Qty - 01 No(c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A,Outgoing :(a)MCCB, 4 polehaving current ratings 100 Amps, AC 415 Volts, withIcu=16 KA, Ics = 100% ofIcu, with thermal magnetic release,complete with spreader links- Qty -02 Nos(b)MCB, DP 6 Amp, C Curve,240 volts, 10 KA - Qty - 01 No 101 Supply, install, testand commissioning of Outdoor cubical type LT feeder pillar box, factory made, dust and vermin proof, double door (front and back openable by key from both side fancy locks), cubical and duly fully compartmentalized and separation from each control switchgear, 415 volts, AC, 50 Hz, IP-54, fabricated with 3.15 mm thick CRCA sheet for outer side and 2mm thick inside complete with and including mounted on angle iron frame stand of size 50 x 50 x 6 mm thick 50 cm long leg, grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate), spray painted inside and outside, having seven tank treatment process for powder coating, enclosed bus bar chamber with aluminium bus bar (04 Nos)of rating not less than 1.5 times of incomming , mounted on PVC insulators, electric connection complete withfrom MCCB to main bus bar, cable glands, thimble complete with and including openable shutters butt hinged, locking arrangement including PCC work, excavation & earth work complete and comprising supply and fixforfollowing etc complete all as specified and as directed:-Incoming : (a) Aluminium busbarchamber comprising 4 Nos strip PVC insulated with current capacity 600 Ampwith stand heat shrinkable sleeking alongwith shrouds for joints, PVC sheathed with colour coding(b)Incommer MCCB, 4 polehaving current ratings 320 Amps, AC 415 Volts, withIcu= 25 KA ,Ics = 100% ofIcu,with thermal magnetic release, complete with spreader links-Qty - 01 No(c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A,Outgoing :(a)MCCB, 4 polehaving current ratings 100 Amps, AC 415 Volts, withIcu=16 KA, Ics = 100% ofIcu, with thermal magnetic release,complete with spreader links- Qty -05 Nos(b)MCB, DP 6 Amp, C Curve,240 volts, 10 KA - Qty - 01 No 102 Supply, install, testand commissioning of Outdoor cubical type LT feeder pillar box, factory made, dust and vermin proof, double door (front and back openable by key from both side fancy locks), cubical and duly fully compartmentalized and separation from each control switchgear, 415 volts, AC, 50 Hz, IP-54, fabricated with 3.15 mm thick CRCA sheet for outer side and 2mm thick inside complete with and including mounted on angle iron frame stand of size 50 x 50 x 6 mm thick 50 cm long leg, grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate), spray painted inside and outside, having seven tank treatment process for powder coating, enclosed bus bar chamber with aluminium bus bar (04 Nos)of rating not less than 1.5 times of incomming , mounted on PVC insulators, electric connection complete withfrom MCCB to main bus bar, cable glands, thimble complete with and including openable shutters butt hinged, locking arrangement including PCC work, excavation & earth work complete and comprising supply and fixforfollowing etc complete all as specified and as directed:-Incoming : (a) Aluminium busbarchamber comprising 4 Nos strips PVC insulatedwith current capacity 400 Ampwith stand heat shrinkable sleeking alongwith shrouds for joints, PVC sheathed with colour coding(b)Incommer MCCB, 4 polehaving current ratings 200 Amps, AC 415 Volts, withIcu= 25 KA ,Ics = 100% ofIcu,with thermal magnetic release, complete with spreader links-Qty - 01 No(c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A,Outgoing :(a)MCCB, 4 polehaving current ratings 63 Amps, AC 415 Volts, withIcu=16 KA, Ics = 100% ofIcu, with thermal magnetic release,complete with spreader links- Qty -02 Nos(b)MCCB, 4 polehaving current ratings 32 Amps, AC 415 Volts, withIcu=16 KA, Ics = 100% ofIcu, with thermal magnetic release,complete with spreader links- Qty -03 Nos (c)MCB, DP 6 Amp, C Curve,240 volts, 10 KA - Qty - 01 No 103 CONDUIT AND WIRING FOR TELE/TVM&L for point wiring with telephone cable copper conductor FRLSH, Two pair, 0.50 sqmm, P.V.C. insulated and sheathed , anti termite, colour coded twisted pairs and rip cord, Double outlet The length of telephone cable upto 07 meter length or less as per site condition.Complete all as specified and directed. Note : PVC Conduit should be measured seperately in respective items 104 M&L for point wiring with Coaxial cable copper conductor FRLSH, P.V.C. insulated and sheathed , anti termite, colour coded twisted pairs and rip cord, Double outlet The length of coaxial cable upto 07 meter length or less as per site condition.Complete all as specified and directed.Note : PVC Conduit should be measured seperately in respective items 105 Supply and fixing modular telephone jack RJ-11, ISI marked white colour fixed in 1 M box fitted in Robust designed assembly plates smug fit on the wall, Dust Free Glossy Finish including pressed GI concealed terminal boxes not less than 1.6 mm thick, inner plate and outer cover, finger proof terminals with captive screws having front fixing & removing features without removing plates complete all as specified. 106 Supply , installation, testing & commissioning of single phase two wire, 240 volts,10-60Amps, accuracy class1.0 with transparent polycorbonate box BIS makin, single source Pre-payment meter, having dual facility of meter reading with hand held meter reading instrument including customer interface unit and having ABC code and inbuilt control switch for disconnection facilities with telephone wire drawing concealed PVC conduit medium grade of suitable size complete all as specified and directed. 107 Supply and fixing modular TV socket (RG-06), ISI marked, white colour fixed in 1 M box, fitted in Robust designed assembly plates smug fit on the wall, Dust Free Glossy Finish including of pressed GI concealed terminal boxes not less than 1.6 mm thick, inner plate and outer cover, all conforming to IS 3854 :1997 with finger proof terminals with captive screws having front fixing & removing features without removing plates complete all as specified. 108 LIGHTENING PROTECTION Materials and labour as in replacement for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel strip 32x6 mm as earth lead soldered and rivetedto earth plate by means of nuts, bolts, check nuts & washers, of galvanizediron or steelwith connected to test point and testing on completion including 40 mm GI pipe medium grade for earth leadprotection from earth point to earth plate, including provnadequate quantity of charcoal dust mixed with35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth platewith 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire meshwith and includingall necessary excavation& earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor. 109 OVER HEAD CRANE(EOT)Design, Supply, installation, testing and commissioning ofelectrically operated, overhead traveling (EOT) cranes of capacity 25 Ton, conforming to IS : 3177 (latest revision), with span of 15 mtrs (approx), height oflift 10-12 mtrs (approx), travel length 30.00 mtrs (approx), suitable for operation on 415 Volts, 3 Phase, 4 wires, 50 HZ supply, double girder box type, with necessary steel supporting structures with Hoist speed4mtrs / min, cross travel speed 5 mtrs / min, long travel speed 5 mtrs / min with VVVF drive alongwith motor of suitable capacity with control panel, power and controlling cables, confirming to relevant IS, controlled by pendent push button station and radio remote control switch of operation, with and including steel rope of suitable size dia , operation system hoist / cross travel/ long travel / electrically operated with pendent DSLof shrouded copper bus bar with wireless remote control system type complete all as specified and directed as per Annexure A to item No 15.94 of BOQ. Note:- (i) The design calculation of crane with relevant drg has to be got vetted from IIT / Govt. NIT and approved by CWE before fabricating of crane.(ii)Supply and fix gantry girder at the building bracket to be provided by the bidder as per direction of manufacturer of crane. Cost of fixing arrangement and supply of gantry gireder deemed to be included in quoted rates. 110 Designing, supplying, installing, testing and commissioning of hoist electrically operated Chain hoist of capacity 1 tons including control panel etc for Lift of 12.0 to 16 Mtrs, Class & duty - Class-II/Medium, Hoisting Motor TEFC of 960 RPM, Hoisting speed 4.0 Mtr/min approx, including hoisting break and hoisting limit switch, Fiber core wire rope confirming to IS: 2266 of suitable size complete all as specified and directed.Note :-(i) Hoist will be mounted on bottom cord of the truss/roof and all necessary clamping arrangement for mounting of EOT hoist will be provided by the bidder and cost is deemed to be included in the quoted rate.(ii) The design calculation of Hoist with relevant drg(the fixing arrangement to truss will be provided by OEM) has to be got vetted fromIIT/Govt. NIT and approved by CWE before fabricating of Hoist.(iii) Hoist operation shall be with pendant control with pendant of die cast or hard unbreakable plastic having push button for up & down movement on /off switches and stay put emergency stop switch. Pendant shall be hanged with chrome plated steel chain covered with sleeves.Note:- Input power supply shall be 415 ± 3% Hz, 3 Phase AC at main control board fitted with bldg and further electric cable connection for hoists shall be provided with suitable size of electric cable. Cost shall be deemed to be including in quoted rates. 111 Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel strip 25x4 mm as earth lead soldered and rivetedto earth plate by means of nuts, bolts, check nuts & washers, of galvanizediron or steelwith connected to test point and testing on completion including 32mm GI light grade pipe for earth leadprotection from earth point to earth plate, including provnadequate quantity of charcoal dust mixed with35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth platewith 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire meshwith and includingall necessary excavation& earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor. 112 REFRIGERATOR/DEEPFREEZER/WATER COOLER :Supply & fixing for Refrigerator with in-built stabilizer of capacity 310 liter ,230 volt, AC, 50 Hz , electric driven, single phase, frost free, smart inverter operation andas per latest BEE 5 star rated complete all as specified and directed. 113 Supply and fixing of metal Top Deep Freezer single phase 240 volt, 50 Hz of capacity 320 Ltr, BEE 5 Star ratings, double door, complete all as specified and directed. star rated, complete all as specified and directed. 114 Supply, installation, testing & commissioning of Water cooler fully Stainless steel(SS 304 grade), electric driven single phase 230 volt, 50 Hz having storage capacity 80 Ltrs & and nominal cooling capacity 40 Ltrs per hour, 100% copper cooling , as per latest versionincluding connection by means of water pipe line, inlet and outlet, PVC pipe connection with brass coupling, nuts at both ends and other necessary fittings including necessary electric connection with and including plug top 15 Amps from voltage stabilizer to water cooler complete all as specified and directed. 115 Supply and fixing ofheavy duty desert cooler PVC body,3-side high efficiency honeycomb pads with dust filters for pure healthy air, Robust weather resistant body for long life, Digital touchscreen & full function remote, Powerful 3 speed fan and empty water-tank alarm, Easily removable and cleanable cooling pads. Fully closable horizontal louvers, Float valve for auto water filling and lockable heavy-duty wheels, 110 m³/hr air delivery low power consumption - 185 watts, storage capacity of tank should not be less than 75 litrescomplete all as specified and directed. 116 Supply and fixing Voltage stabilizer for automatic operation, single phase naturallyair cooled indoor type & designed for input variation between 170 V to 270 V with outputvoltage stabilized at 230 V with accuracy of + 2.5 % and capacity 1 KVA complete all as specified and directed. Note for REFRIGERATOR/DEEPFREEZER/WATER COOLER Items(a)Minimum warranty 2 years on product, 10 years on compressor & 5 years condensor .(b)Item mfg date should not be older than 06 Months from installation date.(c)All items must have a permanent type vinyl sticker on outer body bearing following details and quoted rate are deemed to inclusive cost of sticker.(i)Machine Srl No._____________ (ii)MES No______________ (iii)Date set to work.____________(iv)PRB Page No ______________.(v) Location__________________(vi) CA No.________________________ 117 DG SET & VOLTAGE STABILIZERSupply, installation, commissioningand testing (load trail) of Diesel Engine driven Generating setof capacity 100 KVA as per IS -4722 with AMF panel (Auto mains failure ) recommended by DG set manufacturer , type 415 Volt 3 phase 4 wire system complete with relay panel for automatic starting on mains failure control panel having metersand floor mounted including acoustic enclosure canopy to ensure pollution free complying with all latest CPCB IV norms for pollution and noise with specificationas per Annexure B to item No 16.02 of BOQ . 118 Supply, Installation, commissioning & Testing of automatic out door type servo controlled voltage stablizer of capacity 100 KVA, Three phase,IP 55 Protection, 50 Hz Naturally Oil cooled type BIS certified,unbalanced type, copper wound, metallic body duly power coated with lifting hooks, digital display, relay free smooth and silent operation with 1stfilling of Transformer oil up to level, stablizer shall conform to BIS 9815 Pat 1-1994 and having specifidation as per Annexure A to item No 16.03 of BOQ . 119 FLOOD LIGHT AND HIGHWAY LIGHT FOR HANGERSupply and fixing LED flood light 70 watt, 230 V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with electronic driver and lamp and average life of flood light should not be less than 50000 hours, including clamps, nut, bots, ETC,complete all as specified and directed. Note : The contractor shall submit two years of warranty of LED light fittings from the manufacturer alongwith Purchase Voucher 120 M&L for Submain wiring with two single core FRLSH 2.5 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wallsurface / ceiling for sub main connection includingFRLSH 2.5 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and con-nection to earth dolly complete all as specified. (for connection to flood light and Higbay light)Note:- Two single core FRLSH 2.5 sqmm copper conductor, one run PVC conduit and one run of FRLSH 2.5 sqmm earth wire shall be considered & measured as one unit.In case of roof/ceiling, Stove enamelled conduit shall be used without any extra cost. 121 Supply and fixing MCB SPN 32 Amp rating 240V, 10KA C curve and current carrying ca-pacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 122 Supply and fixing MCB SP 6 to 32 Amp rating 240V, 10KA C curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 123 Supply and fixing MCB TPN Isolator 100 Amp rating 415V, 10KA C curve and current carrying ca-pacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.