Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-09-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-09-2024 |
| 2 | 30-08-2024 | Due Date Extended for tenders closing on 10-08-2024. | Admin Corrigendum Date Extend | 06-09-2024 |
| Sl. No. | Item Description |
| 1 | Taking down chowkats or frame n. exc. 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 2 | Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame,complete all as specified and directed. |
| 3 | Solid PVC frame having profile 60mm x 30mm , single rebate, made out of solid PVC foam with homogenous fine cellular structure having density not less than750Kg/ cum, smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metalCSK screws , complete all as specified and directed. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) |
| 4 | Factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site complete all as specified and directed. |
| 5 | Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-ChargeNOTE : Glass and ACP sheel willbe mesured and paid sepreately |
| 6 | Supply only 4mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty ( or beading )in square n.exc 0.5 Sqm in each panes complete all as specified and directed. |
| 7 | Supply only 3mm thick aluminium composite panel sheet (ACP) colour as approved by Engr In Charge all as specified and directed. |
| 8 | 5.5 mm thick bevelled edge mirror of selected quality fixed to wall with stainless steel spacer stud, standoff screws (min 6 Nos upto 1.00 Square metre), size of standoff screw shall be min 25 x 25 mm , complete all as specified and directed |
| 9 | Demolition of cement concrete (reinforced) of any description andin any position complete all as specified and directed. |
| 10 | Demolition of cement concrete, unreinforced of any description and in any positioncomplete all as specified and directed. |
| 11 | Plain cement concrete 1:7:12 type F-2 using 40mm graded brick coarse aggregate as in sunken floor filling and mass concrete complete all as specified & directed. |
| 12 | Water proofing treatment tosunken portion and adjoining walls of kitchen, WC, Bath & Toilet, etc complete all as specified as under:-(a) 15 mm plaster in cement mortar (1:3) mixed with water proofing compound as per manufacturer’s instructions after roughning and cleaning the surface. (b) Applying cement slurry to the surface @ 0.488 kg /Sq. m of cement mixed with Acrylic based polymer modified cementious composite compound @ 0.253 kg/Sq. m and allowing the surface to air cure for 4 hours. (c) Apply another layer of cement slurry @ 0.242 kg/Sq. m of cement mixed with Acrylic based polymer modified cementious composite compound @ 0.126 Kg/Sq. m and allowing the surface to air cure for 4 hours. (d) Curing the sunken portion with water minimum for 48 hours by ponding. (e)Applying 3mm thick APP membranne with bitumen by torch application to the treated sunken surface over a coat of primer as per manufacturers instructions. (f) Joints/Traps/WC/soil pipes shall be properly sealed with approved sealing compound . |
| 13 | Plain cement mortar 1:3:6 (type C-1 using 20mm graded aggregate), 75mm thick as in Plinth protection , finishing cement concrete even and smooth without using extra cement,all as specified. |
| 14 | Reinforced cement concrete 1:2:4(nominal mix,type B-1, using 20mm graded crushed stone aggregate) as in beams, cantilevers , bressumers, lintels over 1.5m span, all as specified and directed . |
| 15 | Material and labour for mild steel TMT bars 10mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge. |
| 16 | Mild steel TMT bars 5mm dia and over upto and including 10mm dia, cut to length, bent to shape required, including cranking, bendingspirally including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips as in stirrups, spacers and binders , all as specified. |
| 17 | Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished flat surfaces of concrete, all as specified. |
| 18 | Demolition of brick work built in cement mortar including all quoins, arches, pillar etc including disposal of demolished material n.exc 1.5 km complete all as specified and directed. |
| 19 | Brick work with sub class ‘B’ bricks ,old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 , complete all as specified & directed. |
| 20 | Brick work with sub class ‘B’ bricks ofold size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed. |
| 21 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish of the premisses, complete all as specified and directed. |
| 22 | Non skid ceramic coloured tiles7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick bedding layer in cement mortar 1:6, complete all as specified and directed. |
| 23 | Glazed ceramic coloured tiles of size350mmx450mmx7mm thick on vertical surface such as skirting, dado, risers to steps etc set &jointed in neat cementslurry and pointed inwhite or coloured cementto match the colour oftiles over and including 10mm thick backing coat in CM (1:4)all as specified and directed by Engineer-in-charge. |
| 24 | Vitrified ceramic tiles coloured first quality dark shade 8 to 10mm thick (square / rectangular) polished, area of each tiles n.exc 0.36 Square metre, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6complete all as specified and directed. |
| 25 | Coloured non skid porcelain tiles exterior grade 300x300x9-10mm thick heavy duty (Endura from Johnson or equivalent) as in floor, set and jointed in neat slurry and pointed in coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in cement mortar 1:6, complete all as specified and directed by Engineer-in-charge. |
| 26 | Green Marble work 18 to 20mm thick (table rubbed and polished) inflooring , steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade, over and including 15mm thick screed in cement mortar 1:6 complete all as specified and directed. |
| 27 | Providing & fixing hangers of 6 mm dia. G.I. (upto 1200mm length), adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat of 40 x 3 mm size, 60mm long and expansion hold fasteners of 12.5mm dia, 40mm long with and including anodised aluminium snapgrid of size 605mm x 605mm, framed work for false ceiling with and including 4mm thick nonasbestos fibre cement building boardsfixed in aluminium framework with screws, complete all as specified and directed |
| 28 | PVC sheet fillet 35mm wide, 5mm thick for wall paneling, complete all as specified and directed. |
| 29 | Hollow PVC wall lining, with necessary screws and drilling, PVCpanel 0.5mm thick each flap and both flap connected with ribs and overall thickness not less than 5mm design printed in 200 to 300mm wide pannels, fixed as in repaircomplete all as specified and as directed. |
| 30 | Providing 1.0mm to 1.5mm thick dune/ grit sand finish ready mixed product with natural stone granules / minerals in particle size of 400-600, 600-800, 1000-1200 micros consisting of excellent synthetic /acrylic binder anti cracking, anti foaming, anti fungal, anti rusting agents and applied directly over the cement plaster / stone surface over a coat of base coat including necessary steel scaffolding work, including removal of existing paint complete allor in patchesall as per manufacturer instructions complete all as specified and directed. |
| 31 | Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed. |
| 32 | Rendering 15mm thickon fair faces of brick worksurfaces, finished even and fairin cement mortar (1:4), complete all as specified. |
| 33 | Rendering 10mm thick in Cement and Sand mortar 1:6 over fair faces of brick/concrete surfaces ,finished even and smooth without using extra cement, complete all as specified and directed. |
| 34 | Rendering 5mm thick in cement mortar 1:3on fair faces of concrete surfaces as in ceilings , finished fair and smooth, complete all as specified and directed. |
| 35 | Two coats of white wash on wall surfaces including preparation of old surfaces complete all as specified and directed |
| 36 | Two coats of white wash on old decorated ceiling surfaces including preparation of old surfaces, complete all as specified and directed |
| 37 | Three coats of white washing on newwall surfaces including preparation of new surface complete all as specified and directed. |
| 38 | Three coats of white wash on ceiling surfaces including preparation of new plastered surfaces complete all as specified and directed |
| 39 | Preparation of newly plasteredwall surfaces and applying two coats of oil bound distemper over a coat of Chalk whiting on plastered surfaces, preparatory to distemperingcomplete, all as specified and directed. |
| 40 | Preparation of new plastered surfaces of walls and applying two coats of cement base paint (any colour) including all necessary scaffolding and safety arrangements, complete all as specified and directed. |
| 41 | Two coats of synthetic enameled painton steel and iron surfacesover 10 cm width or girth including preparation of new surfaces complete all as specified & directed. |
| 42 | Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed. |
| 43 | Steel water tubes, 15mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls (surface/ concealed), ceiling or laid in floors, inlcuding taking down old tubing complete all as specified and directed. |
| 44 | Steel water tubes, 20mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls (surface/ concealed), ceiling or laid in floors,inlcuding taking down old tubing complete all as specified and directed. |
| 45 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) for concealed pipe etc and making good, cutting not exceeding 10cm girth complete all as specified & directed by Engineer-in-charge. |
| 46 | Vitreous china counter top wash hand basin of size 440 x 470 x 130mm mounted on granite stone slab platform by cutting for couplingetc, fixed as in repair complete all as specified and directed. |
| 47 | 15mm bore pillar tap, fancy type,cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe, fixed as in repair, complete all as specified and directed. |
| 48 | Brass chromium plated bottle traps 32mm bore for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap fixed as in repairscomplete all as specified and directed. |
| 49 | Vitreous china wash downwater closet pedestal patern white with and including plastic seat cover back, closed pattern with flat bottom and cover and mild steel CP or aluminized hanging device, fixed as in repair complete all as specified. |
| 50 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect, fixed as in repair complete all as specified and directed. |
| 51 | Vitreous china squatting pan, “Orissa” pattern size 580mm x 440mm white, with integral foot rests(excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, set with cement concrete, complete all as specified & directed. |
| 52 | Vitreous China Urinal, Half stall type, white and including flushing cistern, flush pipe and waste pipe, fixed as in repair complete all as specified & directed |
| 53 | Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) fixed as in repair, complete all as specified & directed. |
| 54 | PVC(SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed with solvent laid in trenches or in floors, fixed as in repair complete all as specified and directed. |
| 55 | PVC(SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mmincluding nuts bolts etc, fixed as in repair complete all as specified and directed. |
| 56 | All as per serial item No 55 herein before but 75mm bore of pipes -ditto- |
| 57 | 110mm bore PVC (SWR) bend any radius fixed as in repair complete all as specified and directed. |
| 58 | 75mm bore PVC (SWR) bend any radius fixed as in repair complete all as specified and directed. |
| 59 | Supply and fixing 110mm bore PVC (SWR) junction single, (Single T) equal or unequal, fixed as in repair complete all as specified and directed. |
| 60 | Demolition and breaking up drain pipes (Salt glazed ware etc) internal dia of pipe 150mm set in cement mortar including PCC haunching complete all as specified and directed (excavation and earth work shall be measured and paid separately). |
| 61 | RCC pipes class NP2200mm dia bore, with collars, ISI marked, jointed with cement mortar, laid in trenches and tested including fittings of same grade complete all as specified and directed (excavation, earthworkand PCC shall be measured and paid for separately) |
| 62 | Plain cement concrete, type C-2, 1:3:6, using 40mm graded crushed stone aggregate as in bed to drain pipes of 200 mm bore pipe including packing under pipes and testedafter the pipe are laid, complete all as specified and directed. |
| 63 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. |
| 64 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified. |
| 65 | Galvanised mild steel wire cloth 0.56 mm nominal dia of wire & avg width of aperture 1.18 mm in fixed with tinned tacks, fixed as in repair complete all as specified and directed. |
| 66 | 3mm thick, sheet glassordinary quality and glazing with oil putty or beading in squares not exceeding 0.50 sqm in each panes complete all as specified & directed |
| 67 | Looking mirror of size 600mmx450mm of selected quality mounted on PVC frame and back fixed to wall with screw and rawl plugs, fixed as in repairs,complete all as specified and directed. |
| 68 | 2000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered hoisted and fixed in position, including tank nipple, PTMT float valve of 20 mm bore etc, fixed as in repairs complete all as specified and directed. |
| 69 | 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered hoisted and fixed in position, including tank nipple, PTMT float valve of 20 mm bore etc, fixed as in repairs complete all as specified and directed. |
| 70 | 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered hoisted and fixed in position, including tank nipple, PTMT float valve of 20 mm bore etc, fixed as in repairs complete all as specified and directed. |
| 71 | Disconnecting existing tanks, setting aside (or lowering if required) for repair, cleaning works etcand hoisting ifrequired reconnecting and refixing in position of capacity exc 500 ltrs but n.exc 1000 ltrs, complete all as specified & directed. |
| 72 | Bib taps brass, fancy type, with wall flange, chromium plated, cast copper alloy, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed. |
| 73 | Chromium plated, fancy type shower rose with swivel joints 125mm dia with arm and fixing to steel pipe 15mm bore, fixed as in repairs,complete all as specified and directed |
| 74 | Angular stop cock with wall flange, cast copper alloy, chromium plated, fancy type , screwed both ends for iron pipe or for unions, suitable for 15mm bore pipe,fixed as in repairs, complete all as specified and directed |
| 75 | Stop valve, cast copper alloy,screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 20mm bore pipe,complete all as specified and directed. |
| 76 | Stop valve (concealed type), chromium plated, fancy type, screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 15mm bore pipe,fixed as in repairs complete all as specified and directed. |
| 77 | 150mm aluminum anodized barrel tower bolts of extruded section, complete all as specified. |
| 78 | Aluminium alloy, anodized, sliding door bolts with hasp staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium, 150 mm long and dia of rod not less than 16 mm, ISI marked, complete all as specified. |
| 79 | 125 mm aluminium handles cast typecomplete all as specified and directed. |
| 80 | Aluminium alloy, anodized, sliding door bolts with hasp staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium, 250 mm long and dia of rod not less than 16 mm, ISI marked, complete all as specified. |
| 81 | 200 mm size aluminium , barrel tower bolt of extruded section and fixed complete all as specified and directed. |
| 82 | 150 mm aluminium handles cast typecomplete all as specified and directed. |
| 83 | Floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size),complete all as specified and directed. |
| 84 | Towel rail 600mm long ofPTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (minimum weight 190gms), fixed as in repair complete all as specified and directed. |
| 85 | PVC (SWR) floor trap 100mm bore, plain with grating incl jointing with solvent cement, fixed a in repair complete all as specified and directed. |
| 86 | PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including 32mm dia PVC long bend, set with concrete and making good to floor, fixed as in repair complete all as specified & directed. |
| 87 | 15mm dia PVC connection with PTMT nut,of length 450mm, fixed as in repair complete all as specified and directed. |
| 88 | 75 mm size butt hinges medium weight cold rolled mild steel complete, all as specified and directed. |
| 89 | 100 mm size butt hinges medium weight cold rolled mild steel complete, all as specified and directed. |
| 90 | Brass chromium plated soap dish (Single soap), fixed to plugs with chromium plated brass screws, fixed as in repairs complete all as specified and directed. |
| 91 | Granite stone slabs, 16 to 18mm thick,width and length as per site requirement, best qualitymachine cut andpolished to be fixed infloors,cooking plateform, tread, raiser of steps and vertical surfaces etc and jointed with gray cement slurry and pointed in white cement mixed with marble dust (1:2) with admixture of pigment to match the shade of slab, rubbing, cutting / rounding of edgesand corners where required with and including 15 mm thick screed bed in cement mortar 1:4, Complete all as specified and directed. |
| 92 | Kota Stone Slab flooring, 20-25mm thick, best quality over and including cement screed bed 15mm thick in cement mortar 1:6, laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab including cutting, rubbing, grinding and polishing (Mirror finish) complete all as specified and directed. |
| 93 | All as per serial item No 92 hereinbefore but on skirting / vertical surfaces laid over and including 10mm screed layer in cement mortar 1:3, cutting, rubbing, grinding and polishing complete, all as specified. |
| 94 | 100mm thick PCC 1:3:6 type C-1 (using 20m graded crushed stone aggregate) as insub base, finished fair and even without using extra cement, complete all as specified and directed. |
| 95 | Solid PVC board 22-25mm thick, interior grade white colour, fixed with screws as in kitchen cupboard, shutter,wrap free , impact resistant, fire resistant and smell freecomplete, all as specified and directed. |
| 96 | Continuous (piano) hinges, mild steel bright finish, width of flap when open30mm, fixed as in repair complete all as specified and directed. |
| 97 | PVC body magnetic shutter catcher for kitchen cup boards, fixed with standard steel screws, complete all as specified and directed. |
| 98 | Extruded aluminium alloy handles, fabricated type, 150mm long , all as specified. |
| 99 | 150mm long Aluminium anodised, barrel tower bolts of extruded section and fixed, all as specified and directed. |
| 100 | 40mm dia cupboard brass knob fixed with nut screw and washer fixed in any position, complete all as specified and directed. |
| 101 | 75mm hasp and staple,aluminium anodised, wire type, including bolt to hinge plate and fixed with screws, fixed as in repair complete all as specified and directed. |
| 102 | 25mm dia stainless steelcurtain rod including fixing fancy types brackets, stops, rollers etc., as in repairs complete all as specified and directed. |
| 103 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil, complete all as specified and directed. |
| 104 | 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. |
| 105 | Hard core of gauge of broken stone or boulders, not exc 63mm , deposited spread and lavelled in layers n.exc 15 cm thick, watered & rammed to a true surface ,complete all as specified. |
| 106 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 107 | Plain cement concrete type B-0, 1:2:4 using (2012.5 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. |
| 108 | Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. |
| 109 | Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed. |
| 110 | Wash hand basin, vitreous china, flat back , white ofsize600X480mm, MS angle bracket of suitable length and size complete all as specified and directed. |
| 111 | 32mm dia waste coupling / waste fitting of PTMT any colour high-pressure screwed for iron pipe and fixed (minimum weight 45 gms), fixed as in repaircomplete all as specified and directed. |
| 112 | 3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3.6kg/sqm andreinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS, over primer coat bonding material of blown bitumen 85/25 grade heated to working temperature of 180° C applied @1.2Kg/Sqm. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions and finished,complete all as specified & directed. |
| 113 | 15mm thick rendering in Cement and Sand mortar 1:4 over roof slab a finished even and fair mixed with water proofing compound, including dimantling of the existing roof slab / suken portion complete all as specified. (NOTE : WPC will be measrued and paid separately) |
| 114 | Roughening surface of old concrete floor by picking, seeping clean and washing down with water to remove dust etccomplete all as specified and directed. |
| 115 | Supply only integral water proofing compound (ISI Marked) complete all as specified & directed. |
| 116 | Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socketor power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete |
| 117 | Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. |
| 118 | All as per serial item 117 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed |
| 119 | All as per serial item 117 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed |
| 120 | All as per serial item 117 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 121 | Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. |
| 122 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. |
| 123 | Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. |
| 124 | Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. |
| 125 | Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. |
| 126 | Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. |
| 127 | Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB\"s ,MCB\"s etcand removing from site, Complete all as specified and directed . |
| 128 | Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . |
| 129 | MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed |
| 130 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 131 | MCB, SPN , 240 volt,40 to 63Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 132 | MCB DP240 volt, 32Amps, 10 KA , \"B\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 133 | MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 134 | LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable sizefixed as in repair complete all as specified and directed. |
| 135 | Slim LED lights fitting, 4 feet,1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. |
| 136 | Slim LED lights fitting, 2 feet,1x 10W, inverter rechargeable,220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. |
| 137 | Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. |
| 138 | Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)For the purpose of measurement, 2 single core of 6 sqmm and one single core earth cable of 6 sqmm cableshall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth |
| 139 | Exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with blades, frame and louvers complete all as specified and directed. |
| 140 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter |
| 141 | LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, as in repaircomplete all as specified and directed. |
| 142 | Fixing only exhaust fan in repair and connecting up to and including provision of 2 core single flexible cable for ceiling rose/ connector to fan including clean of blade / body cover etc complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy