Tender Document For Electrical Work Of Union Bank Of India Gda Taramandal Branch Gorakhpur => Limited; 1) SITC of 200Amp Kit kat Fuse unit 3nos with 200 Amp neutral link on wooden board (3 * 3) complete with connections . ( For Total Load ) No 1 2) ELECTRICAL PANEL Design, manufacture, providing, storing & installing in position, effecting proper connection, testing and commissioning of panel made of 14 SWG, CRCA sheet steel. It shall be dust and vermin proof. It shall have compartmentalized construction with bus bar chambers, cable alley, cable glands plate etc. as required, duly painted from inside as well outside. It shall have the following - In commer:-1No. 125 Amp.TPN SFU with HRC fuse -1set Busbar. 150 Amp., 3 phase, 4 strips, 415 volts, 50 Hz. copper busbars with colour coded PVC heat shrinkable sleeves. Instruments. Multi function Meter for Voltage, Ampere, Power factor, KWH, Data 1 No. Outgoing. 4Nos. 63 Amp. TP,16KA M CB (For LDB, PDB, UPS,and Spare Feeder) 32 Amp DP MCB -2Nos ( For Strong Room & Gloshine Board) SITC of 100 Amp 4Pole Off load Change over switch complete The design of panel should be got approved by the Architect before manufacturing. The job shall be completed, to the satisfaction of the Bank Engineer/Architect. No 1 4) UPS I/P, O/P AND DISTRIBUTION a) SITC of 4 WAY TPN DB D.Door as LDB & PDB complete with 2 No. 40 AMP TP 10KA MCB as incomer and 10 NOS. 6-32 AMP. SPMCB as outgoing. No 1 b) SITC of 40 Amp DP MCB 10KA in Matel incloser for UPS Input / output power supply complete in all respects as required. No 1 c) SITC of 12 WAY SPN DB D. Door as UPS power Destribution Board complete with 1No. 40 AMP DP 10KA MCB as incumer and 16nos 10Amp SP MCB 10KA for outings. No 1 5) LIGHT & Fan RAW POWER & AC Power Distribution Boards a) SITC of 4 WAY TPN DB D.Door as LDB & PDB complete with 1 No. 40 AMP TP 10KA MCB as incomer and 12NOS. 6-32 AMP. SPMCB as outgoing. No 2 b) SITC of 4 WAY Horziintal TPN DB D. Door as PDB complete with 1 No. 63 AMP TP 10KA MCB as incomer and 18NOS. 16 AMP. SPMCB as outgoing. No 1 6) CABLES a) SITC of 3.5 Core 50 Sq.mm Aluminium Armoured Cable (From Main Power supply sorce to 200Amp Kit Kat Fuse Units to Change over Switch to Main power control Panel complete with end termination and all respect as required. Mtr. 33 b) SITC of 4X6.0 +1X 4.0Sq.mm Copper submain wire (Panel to LDB,PDB, UPS input Power supply ) in required dia pvc conduit complete in all respect as required. Mtr. 28 c) SITC of 4X10.0 +1X4 Sq.mm Copper sub main wire (Kit kat Fuse Unit to AC DB, in required dia pvc conduit complete in all respect as required. Mtr. 12 d) SITC of 2X6.0 +1X2.5 Sq.mm Copper wire ( UPS output MCB to UPS DB, ) in required dia pvc conduit complete in all respect as required. Mtr. 40 7) EARTHING a) Preparation and commissioning of earth terminal PIP technology GEL type 80mm dia 3000mm long earth electrod complete in all respect as per Indian Electrical code of practice.( 1No for Main Neutral Earthing, + 1No for Main Panel, LDB, PDB, AC DB body Earthing + 1No for UPS & UPS DB body Earthing + 1No for UPS output Neutral Earthing.) Nos 3 b) SITC of 10 Sqmm PVC insulated Copper Earth Wire from Earth terminal to load point in required dia pvc conduit complete in all respect as required. Mtr. 78 8) UPS POINT a) Supply & Installation of point wiring for premary UPS or stabilized power plug points on workstations / table for computers using 3 X1.5 Sq.mm copper conductor multi starnd FRLSH PVC sheathed flexible wire pulled through floor raceways/conduit and taken upto table top using PVC rigid or flexible conduits run within wooden/metal partitions. Each point consisting of 2 nos of 10A and 1No 16Amp, 2/3 pin sockets & 1 No., 16A Modular Switch , wired together forming one point. The earth wire of green color only. Nos 10 9) RAW POWER POINT a) Supply & Installation of point wiring for Premary Raw power plug points on workstations / table for computers using 2 X2.5 +1X X2.5 Sq.mm copper conductor FRLSH PVC sheathed flexible wire pulled through floor raceways and taken upto table top using PVC rigid or flexible conduits run within wooden/metal partitions. Each point consisting of 1 nos of 6A , 2/3/5 pin sockets & 1 No., 16A Switch Modular , wired together forming one point. The earth wire of green color only. Nos 10 10) AC POWER POINT a) Supply & Installation of point wiring for AC power plug points using 2 X4.0 +1X2.5 Sq.mm copper conductor FRLSH PVC sheathed flexible wire pulled through PVC rigid or flexible conduits run within wooden/metal partitions. Each point consisting of 1 no 20/25 Amp matalic plug and socket DB with 20/25 Amp 10KA SP MCB wired together forming one point complete in all respect as required. The earth wire of green color only (For 1/1.5 Tr , Window / Split AC). No. 3 11) LIGHT/FAN POINT Supply & Installation of concealed point wiring using 600v grade 1.5 Sq.mm copper conductor PVC insulated wires (with proper R,Y,B color code ) pulled through PVC conduits laid concealed over false ceiling including 2 Nos. 2.5 sqmm circuit wires from the relevant DB and also including 2.5 sqmm green color copper earth wire and switch plate, switches, etc. as approved by the Banks Engineer/Architect. a) Primary light points including the cost of 10A modular switch Nos. 19 b) Secondary light points looped from the above point Nos. 8 c) Ceiling Fan Point complete with electronic regulator Nos. 0 d) Wall Fan Point along with 10AMP switch Nos. 11 e) Exhaust Fan Point along with 10 AMP switch Nos. 2 f) Call bell point along with switch Nos. 1 g) 10Amp Switch socket in switch board Nos. 8 12) DATA CABLING & POINT a) SITC of Computer data outlet point UTP CAT-6e in PVC conduits/Raceways. The rate shall include termination at both ends.complete with information outlet with plate & suface Box at individual Tables complete in all respect as required. Nos. 8 b) Supplying and fixing of 2 mtr long crimped patch cord Nos. 8 c) SITC of Computer Data Rack 9U D. Link make complete with Wire manager, Power supply card .Hardwere etc and all respects as required Nos. 1 d) SITC of 24 Port Patch Panel D. Link make complete in all respects as required Nos. 1 13) VOICE NETWORKING d) SITC of 2RJ11 Telephone socket out let with plate and box complete with 2Pair telephone cable in pvc conduit, complete in all respect as required Nos. 3 14) FIXTURES a) SITC of of Square light fitting (2X2) LED 36 Watt Complete in all respect as required Nos. 8 b) SITC of of Down lighter fittingLED 12 Watt Complete in all respect as required Nos. 8 c) SITC of LEDTube Light 20Watt Complete in all respect as required Nos. 2 d) SITC of 9Watt LED Bulb with Holser complete as required Nos. 2 e) SITC of Wall Mounted Fan 450 mm sweep metel body Complete in all respect as required Nos. 11 f) SITC of 1200mm sweep Ceiling Fan Complete in all respect as required Nos. 0 g) SITC of Exhaust Fan Metal body (12) Complete in all respect as required Nos. 2 h) SITC of Call Bell.Complete in all respect as required Nos. 1