| 1 | Schedule\"A\" Part-I: B&R works |
| 2 | Roughening surfaces of old concrete floor by picking, sweeping clean & washing down with water to remove dust etc and brushing neat cement slurry at the rate of 3 kg per sqm complete all as specified and as directed. |
| 3 | M&L for non skid ceramic coloured tiles (Joint free)7 to 8 mm thick ( Square/rectanguler) area of each tile exc 0.18 Sqm but not exc 0.38 sqm in ist quality provided as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including cement screed bed 15mm thick in cement mortar 1:4 base complete all as specified and directed. |
| 4 | M&L for non skid coloured( joint free )ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18Sqm but n. exc. 0.38 Sqm, vertical surfaces, in skirting etc. set and jointed in neat cement slurry and pointed in whiter or coloured cement to match as in floor,including 10mm thick cement plaster in cement mortar 1:3 all as specified and directed. complete all as specified and directed. |
| 5 | Dismantling of AC sheet corrugated / Semi corrugated sheets in wall cladding or in roof covering complete all as specified and as directed |
| 6 | M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws complete all as specified and as directed |
| 7 | M&L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screwscomplete all as specified and as directed |
| 8 | Taking down chowkat with shutter/without taking off shutter from the frame exe not exc 1.50 Sqm each complete all as specified and directed. |
| 9 | S&F Powder coatedaluminium window sliding type three track (2 glazed & one gauze shutter ) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazingcleats, rubber packing , screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge and making good the surface complete all as specified . |
| 10 | M&L framed work such as grills, grating, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways railing framework of water tank and siliar work all as specified and as directed. |
| 11 | Applying two coats of synthetic enamel paint on steel & iron surfaces of any description, n exc 10cm width or girth when unconnected with other painting or when painted in different tint, including preparation of new surface & applying one coat of red oxide, zinc chrome |
| 12 | Supply & Fix in Repair 25mm dia mild steel chromium plated curtain rod fixing with brackets, stop, rollers complete all as specified and as directed. |
| 13 | Dismantling ceiling board(fibre pulp insulation) or insulation boards any thickness including cover fillets complete all as specified and as directed |
| 14 | M & L for preparation of new unplastered surfaces over ceiling and applyingtwo coats of oil bound distemer over a coat of primer on board complete all as specified and directed. |
| 15 | Material and labour for 4mm thick Asbestos cement plain building boards fixed to timber framework with screws complete all as specified and as directed. |
| 16 | Taking down chowkat with shutter/without taking off shutter from the frame exe 1.50 Sqm but n.exc 4.00 Sqm each complete all as specified and directed. |
| 17 | S & F 30 mm thick factory made flush door solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified |
| 18 | S&F for pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 125 x60 mm complete all as specified. |
| 19 | S&F for pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 105 x60 mm complete all as specified. |
| 20 | S&F 35mm thick 2nd class hard wood skeleton shutter open rebated & prepared to receive glass, gauge etc (with out sash bars) edges of framing plain,chamfered or rounded fitted with cut and mitred beads for securing glass, gauge etc complete all as specified and directed. |
| 21 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm with stainless steel wire staples complete all as specified and as directed |
| 22 | S&F 150mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and as directed. |
| 23 | S&F 200mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed. |
| 24 | S & F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy. |
| 25 | M&L for two coats of synthetic enamel paint over one coat of pink primer on wooden surfaces of any description, not otherwise described, over 10cm width or girth incl preparation of new surfaces complete as specified and directed. |
| 26 | Demolition of cement concrete(un Reinforced) of any description in any position not otherwise specifically provided for etc. complete all as specified and directed. |
| 27 | M & L 75mm thick PCC 1:3:6 type B-2 ( 40mm graded aggregate) thick as in Path & plinth protection& finishing the surface even & fair whtiout using extra cement complete all as specified and directed. |
| 28 | Taking down plaster on brick or stone wall, ceiling etc incl racking out joints hacking for keys scrubbing down with water etc complete all as specified and directed.etc. |
| 29 | M&L for external rendering 15 mm thick in CM 1:4 mixed with [email protected]/ bag by weight of cement on brick work or concrete surfaces of wall finished even and smooth complete all as specified .Note-WPC shall be measured and paid seperately. |
| 30 | Supply only Liquid water proofing compound |
| 31 | M & L 10mm thick rendering on other than fair faces of brick work or concrete surface in cm 1:6 to be finished as spcified by engr-in-charge. |
| 32 | M& L for 2mm thick Wall care putty on wall Surface incl preparation of new surface compete all as specified and as directed |
| 33 | M& L for 2mm thick Wall care putty on wall Surface incl complete removal of existing treatment and preparation of old surface compete all as specified and as directed |
| 34 | M & L two coat ofOil bound distemper over a coat of pimer complete all as specified and as directed |
| 35 | M& L for two coat of cement base paint on new plastered surface over a coat of primer including preparation of surface complete all as specified and as directed |
| 36 | M & Lfor one coat of cement base paint on old painted surface including preparation of surface complete all as speified. |
| 37 | M & L foFinishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) incl preparation of old surface complete all as speified. |
| 38 | Applying one coat of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of old painted surface. |
| 39 | Demolition of brick work built in cement mortar complete all as specified and as directed. |
| 40 | M&L Brick work with sub class B bricks straight or curved on plan exe 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed |
| 41 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)complete all as specified and directed. |
| 42 | M&L 25mm thick P.C.C (1:2:4) type B-1 using 20 mm graded stone aggregate as in floor finished rough complete all as specified and as directed. |
| 43 | Schedule\"A\" Part-I: E&M works |
| 44 | Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, Bell push, call bell, ceiling rose, sockets, switch sockets, regulator, lamp holder etc by unscrewing from board carefully and keep aside for schedule of credit to contactor including making good of the disturbed surfaces, all as specified and directed. |
| 45 | Material and labour for point wiring (surface type) with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, neutral and 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC conduit (medium grade) of adequate sizewith fittings and accessoriesas required at site including suitable size ofGI boxes of thickness not less than 0.8 mm thick and earth continuty conductor shall be connected to common earth and earth dolly for one light/fan point controlled by one wayswitch complete all as specified as directed.Note for item Nos. 43 to 46 : (i)Cost of cutting of wall, if any, for housing of GI box, ceiling rose, etc and also making good the disturbed surfaces are deemed to be included in unit rate.(ii) Cost of GI box of suitable size shall be deemed to be included in the qouted rate. |
| 46 | All as per item No 43 above but for one 3/5 pin 6 Amps socket outlet on the same board with other switches. |
| 47 | All as per item No 43 above but for one 3/5 pin 6 Amps socket outlet on the independent board. |
| 48 | Material and labour for point wiring (surface type) with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 2.5 sqmm (nominal area) for phase, neutral and 2.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC conduit (medium grade) of adequate sizewith fittings and accessoriesas required at site including suitable size ofGI boxes of thickness not less than 0.8 mm thick and earth continuty conductor shall be connected to common earth and earth dolly for one light/fan point controlled by one wayswitch complete all as specified as directed. |
| 49 | Material and labour for switch socket combination multi purpose 2 in 1, 5 Pin,5 and 15 Amps, flush type ISI marked complete all as specified and as directed. |
| 50 | Materials & labour for switch piano flush button 5/6 Amps single pole, 1 way 240 V ISI marked complete all as specified and as directed. |
| 51 | Material and labour for switch socket combination 5 Pin, 6 Amps flush type ISI markedcomplete all as specified and as directed |
| 52 | Materials and labour for socket out let 5 Pin, 6 Amps flush typecomplete all as specified and as directed. |
| 53 | Materials and labour for ceiling rose surface bakelite,PVC/poly 65 x 50mm, three terminals complete all as specified and as directed. |
| 54 | Materials and labour for electronic fan regulator (step rotary type), AC 240 voltcomplete all as specified and as directed. |
| 55 | Supply & fixing MCB DB (Double door) SPN, 8 way , 200 A rated IP-43,IK-09, sheet steel with bus bar, din rail, neutral link and earth bar(concealed in wall) including taking down old DB with fitting & fixtures all as specified and directed. |
| 56 | Supply andfix MCB single pole 6 to 32 amps, 240 volts, 10 KA, \"B\" series with all incoming / outgoing connections with proper size of lugs complete inculdingtaking down the old unserviceable one all as specified as directed. |
| 57 | Supply andfix MCB single pole & neutral 6 to 32 amps, 240 volts, 10 KA, \"C\" series with all incoming / outgoing connections with proper size of lugs complete inculdingtaking down the old unserviceable one all as specified as directed |
| 58 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete complete including taking down old unserceable light fitting all as specified and directed. |
| 59 | Material and labour for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtrs deep below GL) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (Light grade) and 20mm dia GI pipe (medium grade) for watering and connected to control switch as directed including necessary earthwork as in soft/loose soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:1.5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 100mm C/C both way and two Nos lifting handle made of 12mm dia TMT bar and set in cement mortar (1:4), funnel, wire mesh, char coal or coke and salt in alternate layer, testing, etc complete all as specified in electrical plate No 3 of SSR Part-I including taking down old earthing. |
| 60 | Material and labour for sub main wiring with two single core ,1100 V grade ,PVC insulated cable with Copper conducter FRLS unsheathed cable of size 4.0 sqmm drawn through & including PVC Casing -N- capping with 4.0 sqmm PVC insulated copper wire single core for continuous earthing after taking out old unservicable submain wiring complete all as directed. Note : Two run of 4.0 sqmm &one run of 4.0 sqmm of cable shall be measured as single run. |
| 61 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Including taking down old unserceable light fittingcomplete all as specified and as directed. |
| 62 | Materials and labour for lamp holder suitable for LED lamp 9 wattinsulated body with back plate for angle/batten fittings complete all as specified and as directed. |
| 63 | Taking down ceiling fans/ of any size and kept in store complete all as specified and directed. |
| 64 | Hanging/refixing ceiling fans of any sizecomplete all as specified and directed. |
| 65 | Excavation in trenches not exceeding 1.5 m width or n exc 10 sqm on plan andn.exe 1.5 m in depth for taking out/laying ofcable,foundation etcand getting out in soft/loose soil complete all as specified and as directed. |
| 66 | Returning and filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft / loose soil complete all as specified and as directed. |
| 67 | Removing surplus soil to a distance not exceeding 50 mtrsand depositing where directedincluding spreading, leveling at a level notexceeding 1.5 mtr from the starting point complete all as specified and as directed. |
| 68 | Supply, Laying,connecting,testing and commissioning of XLPE insulated and PVC sheathed ,armoured heavy duty UG cable with stranded alluminium conductors 10 sqmm x 2 core,1100 Volt grade, laid in trenches / surface / wall / roof / pole / through pipe including takingdown old u/s cable,compleate all as specified and as directed Note :- (i)Pipe and bricks for cableprotection and sand cushioning shall be measured and paid separately as per site . |
| 69 | Material and labour for sand cushioning with clean dry sand in trenches for cable protection complete all as specified and as directed.Note:- Punned depth shall only be measured and paid. |
| 70 | S & F bricks well burnt sub class ‘B’ bricks in trenches on cable as cable protection across the length of the cable (width wise) complete all as specified and as directed. |
| 71 | Supply and lay GI pipe 50 mm bore (dia) light grade in trenches/road/surface/pole/wall crossing for protection of cable with necessary fittings as required including takingdown old u/s GI pipe complete all as specified and as directed. |
| 72 | Cutting hard standing / road for laying of cable / protection pipe complete all as specified and as directed. |
| 73 | Material and labour for PCC (1:4:8) type D-2 (using 40mm graded aggregate) for filling and making good of disturbed surfaces of road/hard standing etc complete all as specified and as directed |
| 74 | NOTES :-1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.2.Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc, required for complete and proper execution of the work. Refer Schedule \"A\" notes for details. |