Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Estimate For Charging Station and Washing Ramp |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond thebuilding area and stacking and spreading as directed, dewatering, preparing the bedfor the foundation and necessary back filling, ramming, watering including shoring andstrutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means |
| 3 | Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means |
| 4 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete |
| 5 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 6 | Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite / quartzite / gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 7 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compa finishing the formed surfaces with cement mortar 1:3 of sufficient min thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 8 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs anddrawings or as directed including steel centering, formwork, cover blocks, laying /pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fineaggregate (Crushed sand VSI Grade) |
| 9 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 10 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameter for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, stair , newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 11 | Providing and laying in situ / ready mix M-20 cement concrete of trap /granite /quartzite/gneiss metal for approach slab / Rigid pavement including compacting, finishing, curingetc. complete. (excluding reinforcement) (with reversible drum type mixer/ concretebatch mix plant (pan mixer) with SCADA with fine agreegates of requiredspecifications (Natural sand / VSI sand finely washed etc ), cement 6.40 bags/cumt) |
| 12 | Providing and laying Cast in situ/Ready Mixcement concrete in M20 of trap/ granite/ quartzite/gneiss metal for steps including steel centering, formwork,laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 13 | Royalty Charges |
| 14 | Quality Control Charges |
| 15 | Estimate for Warehouse Building |
| 16 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 17 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineerincharge inlayersof15cm to20cmincludingwateringandcompactionetc. complete. |
| 18 | Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting,rougheningthemifspecialfinishistobeprovided,finishingunevenand honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered bygunnybag,plastic,tarpaulinetc.(Woodencenteringwillnotbeallowed.),withfully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) |
| 19 | Providing and laying in situ /Ready Mixcement concreteM-20of trap / granite /quartzite/ gneiss metalforR.C.C.work infoundationslikeraft,stripfoundations,grillageand footingsofR.C.C.columnsandsteelstanchions etc.includingbailingoutwater, Steel centeringformwork,laying/pumpingcoverblocks,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) |
| 20 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirectedincludingsteelcentering,formwork,coverblocks,laying/pumping, compactionandrougheningthesurfaceifspecialfinishistobeprovidedandcuringetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 21 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 22 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 23 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.chajjaasperdetaileddesignanddrawingsincludingsteelcentering,formwork,coverblocks, laying/pumping,compactingand rougheningthesurfaceif specialfinishistobeprovidedandcuring complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLC with SCADAenabled reversible DrumType mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) |
| 24 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns,canopies,staircase,newels, chajjas,lintelspardis,copings,fins,archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 25 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposedfaces, raking out joints on exposedfaces and watering etc. Complete. |
| 26 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete |
| 27 | Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 withoutneeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. |
| 28 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positionsincludingbasecoatof15mmthickincementmortar1:4usingwaterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoatroughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurfacebytakingoutgrainsandcuringforfourteendays scaffolding etc.complete. |
| 29 | Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. |
| 30 | Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour tonew plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. |
| 31 | Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S. 15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. |
| 32 | Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia bars 3 Nos. And strips @250 mm c/c and fixing in wall with 6 Nos. of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 125 mm |
| 33 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. |
| 34 | Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware footrests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. |
| 35 | Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jetandfittingincludingcuttingandmakinggoodtothewallsandfloorstestingetc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) |
| 36 | Providing and fixing coloured glazed earthenware Wash Hand Basin of 55cm x 40 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. |
| 37 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats,curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/-including ponding test etc. complete. |
| 38 | Providing and constructing masonry drain including excavation soling P.C.C. brick work IInd Class in C.M. 1:6 (0.23 mm thick) cement plaster 20mm thick in C.M. 1:4 with cement finish 1:5 mm thick brick bat filling hand broken with R.C.C. cover 3” thick size (1:15 m x 0.6m and as per instructions of site in charge etc. complete. Rate analysis enclosed. |
| 39 | Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. |
| 40 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. |
| 41 | Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 42 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 43 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 44 | Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. |
| 45 | Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint) |
| 46 | Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. |
| 47 | Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. |
| 48 | Compressive strength of C.C.Cube ( set of 3 ) for footing ,column,Beams ,Lintle,Slab.etc. |
| 49 | Water Absortion (set of 5 Bricks),Compressive Strength (set of 5 Bricks),Efflorescence (set of 5 Bricks) for Brick Masonry |
| 50 | Steel Bar Testing set of 3 Bar |
| 51 | Royalty Charges |
| 52 | Estimate For Compound Wall |
| 53 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 54 | Providing and laying in situ / ready mix cement concrete of M10 proportion with trap/ granite/ quartzite/ gneiss metal in foundation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer)) with SCADA with Natural / VSI standard Artificial Sand) |
| 55 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 56 | Providing and laying in situ/Ready Mixcement concreteM-20of trap / granite /quartzite/ gneissmetal for R.C.C. workin foundations like raft, strip foundations, grillage andfootings of R.C.C. columns and steel stanchionsetc. including bailing out water, formwork, laying/pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand |
| 57 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand |
| 58 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand |
| 59 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 60 | Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) |
| 61 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 62 | Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kg/Smt |
| 63 | Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc.Complete |
| 64 | Add For Royalty Charges + surcharge + DMFF |
| 65 | Add For Quality Control Testing Charges |
| 66 | Estimate For Bituminous Road |
| 67 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness |
| 68 | Excavation for roadway in hard murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m.and spreading for embankment or stacking as directed |
| 69 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadamspecification including spreading in uniform thickness, hand packing to proper grade and camber, applyingand brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate,watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I(Using Screening Type A (13.2) mm Aggregate) |
| 70 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadamspecification including spreading in uniform thickness, hand packing to proper grade and camber, applyingand brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate,watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II(Using Screening Type B (11.2 mm) Aggregate) |
| 71 | Providing and constructing 50 mm. thick Modified Penetration Macadam (MPM) road surface including allmataerials, preparing the existing road surface, spreading 40mm. stone metal layers 100% crusher brokenmetal with conical crusher plant heating and spraying the bitumen of specified grade @ 1.75 kg/sqm,spreading 12mm.size chips compacting with static roller having weight 8 to 10 MT. to achive the desireddegree of compaction as per Technical Specification Clause 506 etc. complete. Including picking of existingWBM surface.(VG-30 bulk bitumen rates are considered to arrive at rates) |
| 72 | BITUMINOUS MACADAM: Proving and laying bituminous macadam using crushed aggregates of Grading1, premixed with bituminous binder, transported to site with VTS , laid over a previously prepared surface,finished to the required grade, level, alignment, and rolling to achieve the desired compaction for 80/100mm compacted thickness with 3.3 % using specified grade of Bitumen. -- USING Batch mix type hot mix plantwith SCADA, Sensor Paver, vibratory roller.(VG-30 bulk bitumen rates are considered to arrive at rates) |
| 73 | BITUMINOUS CONCRETE:--Providing and laying bituminous concrete using crushed aggregate of grading1, premixed with bituminous binder @5.40% by weight of total mix and filler, transported at site with VTS,laid over a previously prepared surface, finished to the required grade ,level, alignment, and rolling to achievethe desired density for 50mm compacted thickness with drum mix plant with SCADA, Sensor paver and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen of specified grade with stone dust filler. (VG-30 bulk bitumen rates are considered to arrive at rates) |
| 74 | Quality Control Charges |
| 75 | Estimate For Concrete Platform For Parking Area |
| 76 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. |
| 77 | Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils. |
| 78 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader / Paver on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- By Mix in Place Method and Grading - I Material |
| 79 | Providing and laying in situ / ready mix cement concrete of M-10 proportion with trap/ granite/ quartzite/ gneiss metal in foundation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with SCADA with fine agreegates of required specifications (Natural sand / VSI sand finely washed etc ) |
| 80 | Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete. |
| 81 | Providing and laying in-situ M40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a Tilting type Concrete Mixer as per approved mix design, admixtures, spreading, laying compacting and finished in a continuous operation without paver machine, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. |
| 82 | Providing and fixing in position TMT FE 500, 32 mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete. |
| 83 | Providing and fixing in position TMT FE 500, tie bars precoated with anticorrosive epoxy paint of 12 mm dia. 70 cms.long and at 30.00 cm. C/C and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete |
| 84 | Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. |
| 85 | Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc.complete. |
| 86 | Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (appraox. 25% larger than the initial 3 m One Metric Tonneo 4 mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealentis applied and applying primer. (A) Contraction and longitudinal joints (15 mm. deep x 8 mm.wide) |
| 87 | Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 88 | Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honey combed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 89 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 90 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 91 | Providing and laying Rough Shahabad Stone Flooring 25mm to 30mm thick and of required width in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaningetc. complete. |
| 92 | Providing and laying in situ/readymix M-20 cement concrete of trap/granite/quartzite/gneissmetal for approachslab/Rigidpavement including compacting,finishing,curingetc.complete.(excluding reinforcement) (with reversible drumty pemixer/concrete batch mixplant (panmixer) with SCADA with fine agreegates of required specifications (Naturalsand/VSIsandfinelywashedetc),cement6.40 bags/cumt) |
| 93 | Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor,Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge |
| 94 | Add For Royalty Charges+ Surcharge +DMFF For Sand |
| 95 | Add For Quality Control Testing Charges |
| 96 | Add For Quality Control Testing Charges |
| 97 | 1 % Insurance |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail