Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-08-2024 | Due Date Extended for tenders closing on 10-08-2024. | Admin Corrigendum Date Extend | 06-09-2024 |
| Sl. No. | Item Description |
| 1 | Demolition of existing old tarfelt, waterproofing membrane, plaster of any description, any type, over RCC roof including any roof tiles, cement mortar screed, concrete screed of any thickness, roughening surfaces to receive plaster/screed etc including removing off debris from MoD land complete all as specified and directed. |
| 2 | Rendering 15mm thick on roof surfaces including parapet etc; in cement mortar (1:3), finished even and fair without using extra cement and mixed with water proofing compound as per manufacturer`s instructions, complete all as specified and directed.Note: Water proofing compound shall be measured and paid seprately as supply only. |
| 3 | Liquid water proofing compound conforming to IS 2645-1975 complete all as specified and directed. |
| 4 | Water proofing treatment to RCC roof slab including papapet as under:-(a) Ist Course:- Apply a coat of bituminous primer confirming to IS-3384 @ 0.40Kg/Sqm on prepared surfaces of plaster and after drying of primer, apply a coat of hot bitumin blown 85/25 grade bitumen confirming to IS [email protected] kg/sqm on plastered surfaces.(b) 2nd Course:- APP(Atactic Polypropyline) modified polymeric,membrane, 5 layered, 3mm thick weight not less than 3.0 kg/sqm with 160 grams/sqm non woven polyster made at centre core reinforced laid with 75mm side overlap and 150mm and overlap sealed and finished neat,all joints.(c) 3rd Course:- Apply a coat of bitumen blown 85/25 grade bitumen confirming to IS 1.2 kg/sqm over membrane and dusted with dry sand @0.50 to1kg/sqm over.Note:-Complete treatement shall be carried out by the applicator of the manufacturs only or through their authorised personal only |
| 5 | Water proofing treatment to RCC roof slab including papapet as under:-(a) Ist Course:- Apply a coat of bituminous primer confirming to IS-3384 @ 0.40Kg/Sqm on prepared surfaces of plaster and after drying of primer,apply a coat of hot bitumin blown 85/25 grade bitumen confirming to IS [email protected] kg/sqm on plastered surfaces.(b) 2nd Course:- APP(Atactic Polypropyline) modified polymeric,membrane,5 layered,3mm thick weight not less than 3.0 kg/sqm with 160 grams/sqm non woven polyster made at centre core reinforced laid with 75mm side overlap and 150mm and overlap sealed and finished neat,all joints.(c) 3rd Course:- Apply a coat of semi hot bitumein blown 85/25 confirming to IS-702 @1.2 Kg/Sqm over the membrane, applying two coats of Aluminium paint over a coat of primer all as per manufactures instructions. Note:-Complete treatement shall be carried out by the applicator of the manufacturs only or through their authorised personal only |
| 6 | Providing and laying of water proofing treatment to sunken portion including vertical portion by applying cement slurry mixed with acrylic based polymer modifed cementenious composite compound and including demolition and filling of sunken floor with & including PCC 1:5:10 type E2 (using 40mm graded crushed stone aggreate)(a) First layer of slurry of cement @0.488 kg/sqm mixed with acrylic based primer modified cementenious composite compound @0.253 kg/sqm.This layer allowed to air cure for 4 hours(b) Second layer of cement slurry @0.242 kg/sqm mixed with acrylic based polymer modified cementinious composite compound @0.125 kg/sqm.This layer allowed to air cure for 4 hours.(c) The slope shall be 1:20 towards the corner of outer wall and GI pipe of 50mm dia (Med Grade) be inserted at corner projecting out side 20cm.(d) 15mm thick plaster in cement mortar 1:3 mixed with WPC to be provided while concrete on green(e) Joints of trap /WC/Soil pipes shall be properly sealed with sealing compound.Note (i):-Concrete for sunken slabs shall be mixed with WPC as per manufactures instructions. Before carrying out water poofing treatmentthe sunken shall be tested with water for 48 hours for any leakage/dampness is seen in ceiling below,then treatment is again carried out to RCC slab and it is again tested before passing for next stage(ii) Only floor area shall be measured for payment purpose(iii) WPC shall be measured and paid separately |
| 7 | Screed bed or bedding layer of15mm thick in CM (1:4) for laying of floor finishes & finished the surface even and fair to receive concrete tileetc; complete all as specified and as directed. |
| 8 | Cement concrete tiles 25cm x 25cm x 22mm thick , machine pressed, set jointed and pointed in neat cement slurry in roof, and cut and polished with grey cement and no pigments complete complete all as specified and as directed. |
| 9 | PCC 1:2:4 type B1(using 20mm graded crushed stone aggregate) as in roof padding in roof slab for levelling course complete all as specified and directed. |
| 10 | Dismantling structural steel work including doors, gates but excluding framed truss etc.complete all as specified. |
| 11 | Dismantling old unserviceable asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified. |
| 12 | Dismantling old unserviceable Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified. |
| 13 | Dismandling timber scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, complete all as specified. |
| 14 | Stuctrual steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410(Gde-E250) quality\"A\", complete all as specified and as directed. |
| 15 | Mild steel framed work such as grills, gratings, etc; with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed. |
| 16 | Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 17 | Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 18 | Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. Providing Hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mmsize 60mm long and expansion hold fasteners 12.5mm dia. 40mm long,complete all as specified and as directed. |
| 19 | Non asbestos 4mm thick E-board (classic) of size 60cm x 60cm boards laid on GI snap grid for ceiling, complete all as specified and as directed. |
| 20 | Demolition of brick works or stone boulder masonary built in cement mortar including all quions and arches, pillars etc., but excluding ashlar facing dressed stone work and precast concrete articles, complete all as specified and as directed.. |
| 21 | Brick work with sub class \"B\" brick (using old size burnt bricks) straight or curved on plan exceeding 6mmean radius built in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified and as directed. |
| 22 | Brick work with sub class \"B\" brick (using old size burnt bicks) straight or curved on plan to any radius in half brick thick wall build in cement mortar (1:4), complete all as specified and as directed.. |
| 23 | Taking down cement plaster, on brick or stone wall etc including racking out joints for key scrubbing down with water etc to recive new plaster etc., complete all as specified and as directed. |
| 24 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removingserviceable tiles to storeand rubbish off the premises, complete all as specified and as directed. |
| 25 | Rendering 5mm thick in cement mortar (1:3) as in ceiling, finished the surface even & smooth without using extra cement, complete all as specified and as directed. |
| 26 | Rendering 15mm thick on fair faces of brick works or concrete surfaces of wallsin cement mortat (1:4)finished the surface even & smooth without using extra cement including mixing of WPC as per manufactures instructions, complete all as specified and as directed.Note:- WPC shall be measured and paid separately. |
| 27 | Rendering 15mm thick on other than fair faces of brick works of wallsin cement mortar (1:6)finished even & smooth w/o using extra cement, complete all as specified and as directed. |
| 28 | Preparation of newly palstered surfcaes of walls and applyingtwo coat of oil bound distemper over one coat of primer on plastered surfaces, complete all as specified and directed. |
| 29 | Preparation of newly plastered surfaces of ceiling and applyingthree coat of white washcomplete all as specified |
| 30 | Preparation old plastered surfaces of walls and applying two coat of oil bound distempercomplete all asdirected. |
| 31 | Preparation old plastered surfaces of ceiling and applyingtwo coat of white washcomplete all asdirected. |
| 32 | Preparation ofplastered or un plastered old surfaces of walls andapplying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, complete all as specified and as directed. |
| 33 | Preparation of new plastered surfaces of walls andapplying two or more coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, complete all as specified and as directed. |
| 34 | Demolition of cement concrete (unreinforced) in ground floors& paving not exceeding 15cm thick above or below GL, complete all as specified and as directed. |
| 35 | Demolition of cement concrete reinforced as in chajjas shelves,roof slab and cover slab etc., complete all as specified and as directed. |
| 36 | Roughening surfaces of old concrete floors by picking, sweeping clean and washing down with water to remove dust etc; with brushing neat cement slurry with 3 kg of cement per square meter, complete all as specified and as directed. |
| 37 | 20 to 25mm thick machine cut kota stone slab flooring of size not less than 53cmx53cm, laid and jointed with grey cement slurry and mixed with pigment to match the shade ofslab including rubbing and polishing with mirror cut polishing including 100mm wide marble border all around and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed. |
| 38 | All as Srl item No. 37 above but Kota stone in vertical surfaces such as riser of steps, skriting, dado and pillar etc; including 10 mm thick plaster in cement mortar 1:4 finished even and fair, complete all as specified. |
| 39 | Non skid coloured ceramic tiles 7 to 8mm (Square/rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc; (size of tiles 400x400mm) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shed of tiles including 15mm thick screed bed or bedding in cement mortar (1:4) complete all as specified and directed. |
| 40 | Non skid coloured ceramic tiles 7 to 8mm (Square/rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm in vertical surfaces such as skirtingetc (size of tiles 400x400mm) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shed of tiles including 15mm thick rendering as in cement mortar (1:4) complete all as specified and directed. |
| 41 | Ceramic coloured tiles as in vertical surfaces of size 450x300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade including 15 mm thick plaster in cement mortar 1:4 complete all as specified and directed. |
| 42 | Granite (of any type) slab, 20mm thick, machine cut bedded and jointed with grey cement slurry and jointed with white cement with addmixture of pigment including cutting and finishing including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 43 | PCC 1:2:4 type B-1 using 20mm graded stone aggregade, 50mm thick, as in plinth protection/paths etc laid in allternate bays system each bays n.exe 2.0 Sqm each and finishing even and fairon top without using extra cement with 6mm wide joints through out the thickness of plinth protection in concrete bays and in between the walling and plinth protection,filling the joints with mastic filling comprising one part of bitumen 85/25 or 96/10 grade 3 parts of sand (all by weight) complete all as specified. |
| 44 | 25mm thick PCC 1:2:4 type B-0, using 12.5mm graded crushed stone aggregate as in floor finished even and fair reciving tiles complete all as specified |
| 45 | Reparis to balcony/facia and soffit of chajjas etc by taking down old plaster any type and rendering 15mm thick in cement mortar 1:4 and hacking clearley the edges and corners smooth and rounded for new plastered area exceeding 30 sqcm in width or girth including preparation of surfaces and applying two coats exterior emulsion weather proof paint over one coat of primer incuding scaffolding work upto height of 7m complete all as specified and as directed. |
| 46 | RCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate as in Chajjas and Balcony/Landingetc; and similar work, complte all as specified. |
| 47 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc; rough finished surfaces of concrete flat, complete all as specified and as directed. |
| 48 | Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and as directed. |
| 49 | Reinforcement cement concrete 1:2:4, 20mm graded crushed stone aggregate as in slabs, supporetd on walls, beams and coloumns in floors, roofs, landings, balconies, canopies cantilever shelves and the like complete all as specified and as directed. |
| 50 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thic (horizontal or sloping) sides including supports,overhangs for fair finished surface of concrete flat, complete all as specified |
| 51 | Taking down chowkat or frames with shutterswithout taking off shutter from the frame not exceeding 1.5 Sqmeach and removing from site complete all as specified and directed. |
| 52 | Taking down chowkat or frames with shutterswithout taking off shutter from the frame exceeding 1.5 Sqm but n.exc 4.0 sqm each and removing from site complete all as specified and directed. |
| 53 | Mild steel framed work as in doors, gates or angle iron chowkats or other section with guest plates rails braces, hold fast,guard bars clamps etc Fe 410-W (GdeE- 250) A qualitycompetaall as specified and as directed. |
| 54 | Pressed steel frame of size 105 x 60mm for doors with one or more rebetas including necessary fixing lugs, hinges, lock strike plate etc including one coat of red oxide providing and providing mild steel bars 6mm dia threshold bar and including filling hollow portion of frame with PCC (1:3:6) type C-0 using 12.5mm graded crushed stone aggregate complete all as specified and as diretecd |
| 55 | Pressed steel frame of size 125x60mm for doors with one or more rebetas incl necessary fixing lugs, hinges, lock strike plate etc including one coat of red oxide providing and providing mild steel bars 6mm dia threshold bar and including filling hollow portion of framePCC (1:3:6) type C-0 using 12.5mm graded crushed stone aggregate complete all as specified and as diretecd |
| 56 | PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate for filling hold fast blocks including necessary form work, complete all as specified . |
| 57 | Solid PVC door frame of size 50mm x47mm, made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification, complete all as specified and as directed. |
| 58 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed. |
| 59 | 35mm thick flush door shutters ,solid core with particle board exterior grade as per IS 2022of 199 (part-I) Flush door shutter shall be internally lipped as per clause 8.55.2 of SSR 2009 part-I complete all as specified . |
| 60 | 35mm thick, Glazed and skeleton shutters, second class hard wood , open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats, complete all as specified and as directed. |
| 61 | 12mm thick, particle board as inshutters/shelves etc; interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixedto mild steelframe work with screws, complete all as specified and directed |
| 62 | 18/19mm thick, particle board as inshutters/shelves etc; interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixedtoframe work with screws,complete all as specified and directed |
| 63 | External teak wood lipping 6mm thick fixed with nails,complete all as specified and as directed. |
| 64 | 3mm thick, sheet glass ordinary quality and glazed with oil putty in squares not exceeding 0.5 Sqm in each pane, complete all as specified and as directed.. |
| 65 | 4mm thick, figured glass, pin head type and glazing with oil putty in squares not exceeding 0.5 sqm in each pane, complete all as specified and as directed. |
| 66 | Galvanized mild steel wire cloth 0.56mm nominal dia of wire and overage width of aperature 1.18mm, complete all as specified and as directed. |
| 67 | Butt hinge of size 100mm, medium weight, cold rolled mild steel complete all as specified. |
| 68 | Butt hinge of size 75mm, medium weight, rolled mild steel, fixed as in cupboardwelded with angle iron frame, complete all as directed. |
| 69 | Aluminium anodised barrel tower bolt of extruded section of size 150mm long, complete all as specified and as directed. |
| 70 | Aluminium anodised handle cast type of 100mm size (ISI marked) complete all as specified. |
| 71 | Aluminium alloy anodised, sliding door bolt with hasp and staple (bolt type) & fixng clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extruded section of size 300mm long, complete all as specified and as directed. |
| 72 | MS helical door spring 300mm long, ordinary rat tail pattern including roller plate,complete all as specified and as directed. |
| 73 | Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed bottom of door shutter of size 100mm long, complete all as specified and as directed. |
| 74 | Curtain rail 20mm dia stainless steel chromium plated fixed with stainless steel CP brackest including taking down old unserviceable curtain rod, fixed in repair, complete all as specified. |
| 75 | Factory made box type Steel window Glass and Glazed shutter (Double shutter) of size 79mm x39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron including box type hinges with steel handle and steel peg stay devotiled or welded including 2 No tower bolt of 100mm long and 10mm square bars MS grills including one coat red oxide primer complete all as specified and as shown on drawing No CEUZ/TD/1517/15 Sh No 1/3 to 3/3. |
| 76 | Factory made box type steel ventilators top hung shutter shutters glass and glazed shutter ((Double shutter)including guard bars, hinges, steel handle, tower bolt and steel peg stay,complete with or without glazing bars, devotiled or welded, including one coat of red oxide primer complete shown as drawing No CEUZ/TD/1517/15 Sh No 1/3 to 3/3 and as specified. |
| 77 | Preparation on newly or untreated steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 78 | Preparation newly or untreated wooden surfaces and applying two coats of sythentic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 79 | Vitreous China squatting pan \"Orisa Pattern\" of size 580x440mm, in any coloured with integral foot rest including lime mortor \"S\" trapincluding connection to trap and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor and complete taking down old one fixedin repairs,complete all as specified and directed. |
| 80 | PVC valve less symphonicaction type lowl level flushing cistern white 10 liter capacity with inlet, ball valve, manually operated with one PVC ball valve operated with horizantally plunger type including provision of PVC 32mm dia,flush pipe of required length and making connections complete fixed in repair,complete all as specified and as directed. |
| 81 | Vitreous china WHB (White) of size 550X400mm including waste fittings chromium plated brass, CP steel chain and rubber plug,procelain stopper ,and pair of CI brakets, waste pipe fixed in repair,complete all as specified and as directed. |
| 82 | Fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated,screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed 15mm bore, fixed in repair, complete all as directed. |
| 83 | PVC connection 15mm size,600mm long with PTMT nuts & bolts,complete all as directed. |
| 84 | Plate rack made of stainless steel 0.80mm thick overall size of 786mmx610mmx254mm complete all as directed. |
| 85 | Sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs washers including bedding in cement mortar (1:3) to drawf wall or including fixing contilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm complete all as specified specified and directed. |
| 86 | CP brass angle valves / stop cock (Weight not lessthan 0.40 kg of cast copper alloy (ISI Marked), CP fancy type screwed down high pressure with capstain head screwed both ends for iron pipes 15mm bore fixed in repairs,complete all as directed. |
| 87 | 15mm bore, CP brass bib cock, long body fancy type CP screwed down, screwed for iron pipe for brass ferrule, fixed in repairs,complete all as directed. |
| 88 | CP brass wall mixture for mixing hot and cold water screwed down including connecting legs & wall flanges for iron pipe of 15mm bore, fancy type, fixed in repairs,complete all as directed. |
| 89 | Sheet glass corner shelf assembly consisting of 5.5mm thick sheet glass shelf230mmx230mm size with chromium plated bracket guard, complete all as specified and as directed. |
| 90 | CP brass, towel rail 20mm dia, 60cm long including bracket fency type heavy weight as approved by Engineer-in-Charge |
| 91 | Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and as directed. |
| 92 | 600mm x 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood & fixed to wooden plugs with chromium plated beads screws & cup washeres,complete all as specified and as directed. |
| 93 | Bath cabinet of size 360mm x 450mm x 90mm deep with glass of size 320mm x 450mm x 3mm thick,complete all as specified and as directed. |
| 94 | Taking up or down steel tubing and connection and removing to store bore of pipe 15mm dia, complete allas directed. |
| 95 | Taking up or down steel tubing and connection and removing to store bore of pipe 20mm dia, complete allas directed. |
| 96 | 15mm bore, GI tubing medium grade with all fittings and fixed complete fixed to walls and ceiling and floor/roof complete all as specified. |
| 97 | 20mm bore, GI tubing medium grade with all fittings and fixed complete fixed to walls and ceiling and floor/roof complete all as specified. |
| 98 | Dismantling water tanks and removing to store capacity exceeding 250 ltrs and not exceeding 500 ltrs, complete all as specified and as directed. |
| 99 | Rotational moulded polythylene water storage tank double layered (Cylindrical vertical with closed top) 500 ltrs capacity (ISI marked) hoisted and fixed in position, complete all as specified and as directed. |
| 100 | Ball valve, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe20 mm dia (minimum weight 210 gms), complete all as specified and as directed. |
| 101 | Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe of bore 20mm, fixed in repair, complete all as specified and as directed. |
| 102 | Taking down drainage, eaves gutters and rainwater pipes (any size or pattern any position), including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed. |
| 103 | PVC (SWR) pipes, 110mm bore, single socketed in any length with rubber ring joints fixed to wall, complete all as specified and as directed. |
| 104 | PVC (SWR) pipes 110mm bore, single socketed in any length with rubber ring joints and laid in trenches/floors, complete all as specified and as directed. |
| 105 | PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to wall, complete all as specified and as directed. |
| 106 | PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints and laid in trenches/floors, complete all as specified and as directed. |
| 107 | PVC (SWR) bends any radius, 110mm bore of pipe, complete all as specified and as directed. |
| 108 | 110mm dia PVC (SWR) junctionsingle (single \"T\") equal or unequal, acces door complete all as specified and as directed. |
| 109 | PVC (SWR) branch piece any radius, 75mm bore of pipe, complete all as specified and as directed. |
| 110 | PVC (SWR) Junction,(single \"T\") equal or unequal ordinary or inverted with spigot or socket branch of 75mm bore complete all specified |
| 111 | PVC (SWR) branch piece, 75mm single (single Y) equal or un equal inverted in spigot or socket type all as specified and as directed. |
| 112 | PVC (SWR) vent cowl for 75mm bore pipe, complete all as specified and as directed. |
| 113 | 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified |
| 114 | Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of 100 mm bore of pipe, complete all as specified and as directed. |
| 115 | Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of 75 mm bore of pipe, complete all as specified and as directed. |
| 116 | PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate mixed with water proofing compound as per manufacturer`s instruction as in copings, roof kerb etc including weathering, slightly rounded or chamfered angles and throating etc; includign use of form work, completed all as specified and directed.Note: Water proofing compound shall be measured and paid seprately as supply only |
| 117 | Aluminium anodisedhasp and staple safety type 75mm long with mild steel hinges pin including bolts to hinge plate and fixed with screws, completed all as specified and directed. |
| 118 | Surface excavation not exceeding 30cm deep and average 15cm deep and getting out in hard dense soil, complete all as specified and directed. |
| 119 | Hardcore of guage not exceeding 63mm deposited spread and levelled in layers not exceeding 15cm thick, watered and rolled/rammed to a true surface, broken stone or boulders, complete all as specified and directed. |
| 120 | 100mm thick Plain Cement Concrete as insubbase type D2(1:4:8) using 40mm graded crushed stone aggregate, finished the surface even and fair complete all as specified and directed. |
| 121 | Machine Pressed precast concrete interlocking paver block with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade,laying over and including 25mm thick sand cushion including watering and ramming (Compacted) and joints filled with sand complete all as specified and directed. |
| 122 | PCC 1: 2:4 type B-0, using 12.5mm graded crushed stone aggregate as in edges of path etc; including weathering, slightly rounded or chamfered angles and throating etc; including use of form work, completed all as specified and directed. |
| 123 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed. |
| 124 | Demolition and breaking up drain pipes (Salt glazed ware,AC or Reinforced concrete) set in cement mortar of 150mm dia including bends complete all as specified. |
| 125 | Demolition of reinforced cement concrete of any description and in any position (reinforced cut as required to facilitate demolition), complete all as specified and as directed. |
| 126 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundationetc; or for shafts, wells, cesspits, manholes, pier holes etc; not exceeding 10sqm on plan and not exceeding 1.5m in depth and getting out in any type of soil,complete all as specified and as directed. |
| 127 | PCC 1:2:4 tpe B-0 using 12.5mm graded crushed stone aggregate as in coppings, in lintels upto 1.5m clear span, cills, steps; seismicand other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including use of form work, complete all as specified and as directed. |
| 128 | Concrete bed to drain pipes in 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in bed including packing under, and haunching against the sides of pipes after they are laid and tested for 150mm dia of pipe, complete all as specified and as directed. |
| 129 | RCC class NP-3 pipe of 150mm diadrain pipe laid in trenches and jointed all as specified and as directed. |
| 130 | Precast cement concrete 1:2:4 type B-1,using 20mm graded crushed stoneaggregate as in cover slab (for manhole etc), landing chullah hoods, chajjas, water troughs, mangers, sheleves and similar articles with plain faces complete set in cement mortar (1:4) including use of form work complete all as specified and directed. |
| 131 | Returning, filling in any type of soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and as directed. |
| 132 | Extra for forming fair finish to surfaces of external or internal rounded angles, exceeding 80mm but not exceeding 200mm girth (over 200mm girth to be measured as circular work) complete all as specified and as directed. |
| 133 | Excavating in post holes in any type ofsoil(or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, and removing the excavated material complete all as specified and as directed. |
| 134 | PCC 1:3:6 type C-2, using 40mm graded crushed stone aggregate in foundation, filling and mass concrete complete all as specified and directed. |
| 135 | Mild steel works for posts and struts in fencing,including cutting tops to shapes as directed drilling holes, including for wire etc., flat iron angle and plate filters (for securing wire mesh etc., incuding all necessary drilling, bolting or rivetting etc; and similar work confirming to Fe-290 Gde E-166,complete all as specified and directed. |
| 136 | Supply only Galvanixed steel wire chain link fencing of mesh of size 100x100mm (weight of wire not exceeding 4.0kg/sqm) complete all as specified and as directed. |
| 137 | Fixing only chain link fencing incuding line wires, any mesh, size type to any type of standard, rails straining bolts etc., including provision of binding wire and fixing with MS angle iron fencing posts complete all as specified and as directed. |
| 138 | 10mm dia MS screw bolts (Machine made) with hexoganal or square heads at one ends screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexoganal or square nuts not exceeding 5cm long, complete all as specified and as directed. |
| 139 | Preparation new or previously untreated steel surfaces of any description not exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a one coat of red oxide or zinc chrome, complete all as specified and as directed. |
| 140 | Mild steel round bars, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips(Fe-410 W,Gde-E250 quality or Fe-290,Gde-E-165), complete all as specified and as directed. |
| 141 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power socket) complete, incluing fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floor etc; complete all as specified and as directed. |
| 142 | Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLSH,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 20mm dia , medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green color, connected to common earth dolly complete all as specified and as directed. |
| 143 | Point wiring complete with 1.5 sqmm PVC insulated, FRLSHtype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. flush mountingSS box with top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved colouresandincluding 1.5 Sqmm PVC insulated multistranded FRLSHtype unsheathed (Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:-Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used same make/brand only. |
| 144 | One light/fan/bellpoint controlled by one switch |
| 145 | One socket outlet 05 Amps on the same board |
| 146 | One socket outlet 05 Amps on independent board |
| 147 | One light point controlled by two way switch |
| 148 | Point wiring complete with 2.5 sqmm PVC insulated, FRLSHtype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade (MMS) andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. modular metal flush box with top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved colouresandincluding 2.5 Sqmm PVC insulated multistranded FRLSHtype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:-Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used same make/brand only. |
| 149 | Ceiling rose, 3 terminal, PVC/Polycarbonate body body ISI marked complete all as specifiedand directed . |
| 150 | Modular type switch1way, 6 Amp1 module 240 volt complete all as specified and directed. |
| 151 | Modular type switch2 way, 6 Amp1 module 240 volt complete all as specified and directed. |
| 152 | Modular type Switch16 amps, single pole, 1 way, 1 module, 240 V, ISI marked complete all as specified and directed. |
| 153 | Modular type socket shuttered type 6 amps 2/3 pin combined 2 module 240 V AC ISI marked complete all as specified and directed. |
| 154 | Modular white cover plate with frame 1 module complete all as specified and directed. |
| 155 | Modular white cover plate with frame 2 module complete all as specified and directed. |
| 156 | Modular white cover plate with frame 3 module complete all as specified and directed. |
| 157 | Modular white cover plate with frame 4 module complete all as specified and directed. |
| 158 | Modular white cover plate with frame 6 module complete all as specified and directed. |
| 159 | Modular type socket 6A/16A 2/3 pin combined shuttered socket 2 module 240 V, AC ISI marked complete all as specified and directed. |
| 160 | Fan regulator, modular type electronic step, type 100watts, 2 modile 240volts AC ISI Marked complete all as specified and directed. |
| 161 | Call Bell, Ding dong AC, 230 volt, single pole complete all as specified and directed. |
| 162 | Modular Bell push 6 A, 1 module, 240 V, ISI Marked complete all as specified and directed. |
| 163 | Angle lamp holder, insulated body with back plate complete all asspecified and directed. |
| 164 | LED Lamp retrofit type 12 watt B22 base holder with polycarbonite body and heat sink type complete all as specified and directed. |
| 165 | Renewal of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as directed. |
| 166 | LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as directed. |
| 167 | LED lights fitting 1x 20W, 220V,LED batten surface mounting Genral purpose in Extruded Aluminium housingtube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 168 | LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as directed. |
| 169 | Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) incl taking down existing unserviceable fan and deposit with MES E/Mstore yard complete all as specified and directed. |
| 170 | Sheet steel enclosure for flush/surface mounting distribution board, factory made, protection class IP 36 suitable for mounting MCBs with 200 amps tinned copper bus bar, cable lugs, single pole & neutral 240 volt, 8 ways, double door complete all specified and directed. |
| 171 | MCB single pole & neutral 240 volt, 40 Amp to 63 Amp\"C \" series, 10KA repturing capacity complete all as directed. |
| 172 | MCB ingle pole, 240 volt, 6 to 32 Amp, \"C\" series, 10KA reptureing capacity complete all as directed. |
| 173 | Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size (45X 45X 45)cm, RCC cover 1:2:4 type B1 of size (45X45X6)cmcement mortar, excavation/earth work in any type of soil and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. |
| 174 | Supply, Installation, commissioning and testing Polycarbonate CPRI approved OEM made Meter Panel. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:Meter Panel type Wall Mounted type on Mounting Structure RAL 7016. The Meter Panel should be anti-acid, anti corrosive & Fully Transparent Door for meter Vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of his CPRI TEST REPORT IN POLYCARBONATE only also share panel assemble by OEM, channel partner or sister concerned assembly will not accepted. DEGREE OF INGRESS PROTECTION IP 65IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane and Enclousers makeHensel/Clipsal.The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. OneMain IncomerMCCB 125A TP 25KA Thermal /Magnetic Release with spreader link. MCCB/MCB Nos Operated by Flip Cover. Indicator Provided on each phase. Four Nos Single Phase Sub-Meters. Output supply by MCB DP 32Amp 4 Nos. Meter Enclosures & Enclosures Accessoriesas per RAL 7035. Ten Nos Terminal Blocks Provided for output Supply.Make- Hensel/Schneider/ L&T/ ABB. |
| 175 | Taking down exisitng unserviceable cable of size 16 sqmm, 4 core complete all as specified and directed. |
| 176 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm, 4 core including taking down old unserviceable cable, complete all asspecified and directed. |
| 177 | Double walled corrugated (DWC) pipe of size 50mm including snap fit coupler conforming to IS14930 (Pt-II)/IS 16205 Pt-II for protection of under ground cable complete all as specified and directed. |
| 178 | Taking up or down GI pipe including fitting fixture of pipe size 50mm dia bore complete all asdirected |
| 179 | Taking up or down GI pipe including fitting fixture of pipe size 25mm dia bore complete all asdirected |
| 180 | GI tubing 50mm dia, medium grade with all necessary GI fittings like bends, elbow, unions, tees, sockets, short pieces, plugs, hooks/clamps etc. as required at site and fixed on wall/ceiling or laid in floor or trenches, complete specified and directed |
| 181 | GI tubing 25mm dia, medium grade with all necessary GI fittings like bends, elbow, unions, tees, sockets, short pieces, plugs, hooks/clamps etc. as required at site and fixed on wall/ceiling, complete all as specified and directed |
| 182 | GI tubing 20mm dia, medium grade with all necessary GI fittings like bends, elbow, unions, tees, sockets, short pieces, plugs, hooks/clamps etc. as required at site and laid in trenches, complete all as specified and directed |
| 183 | Cutting the existing 50mm tubing and inserting new GI Tee of size 50mm x 50mm x 25mm dia and including necessary screwing threading, tail pieces, short pieces, jointing material etc complete all as specified and directed. |
| 184 | Cutting the existing 25mm tubing and inserting new GI Tee of size 25mm x 25mm x 20mm dia and including necessary screwing threading, tail pieces, short pieces, jointing material etc complete all as specified and directed. |
| 185 | Gun metal, globe or gate valves20mm borewith iron wheel head, screwed both ends from iron pipe and fixedcomplete all as specified and directed. |
| 186 | Deduction to be made from BOQfor Sch \"A\" Part - II (Schedule of credit) Amount of Rs. 8,89,198.00 during AOC.Note: Tenderers shall not quote for this schedule. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy