Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-07-2024 | Corrigendum | Technical Bid | 20-07-2024 |
| Sl. No. | Item Description |
| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means.Bd.A.1 Page No. 259, Lift upto 1.50m |
| 2 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means.Bd.A.1 Page One Number 259 |
| 3 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.As directed by Engineer in charge. |
| 4 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)Bd. E. 1 Page No. 287 |
| 5 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/quartzite/gneissmetalforR.C.C.workinfoundationslike raft,strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water,Steel centering,formwork,coverblocks,laying/pumping, compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.F.3 Page One Number 298 and B.7, Page One Number38 |
| 6 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite /quartzite/gneissmetalforR.C.C.columnsasperdetaileddesignsanddrawingsoras directedincludingsteelcentering,formwork,coverblocks,laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smoothand even surface or roughening if special finish is to be providedand curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.F.5 Page One Number 300 and B-7,Page No 38.GROUND FLOOR |
| 7 | FIRST FLOOR |
| 8 | SECOND FLOOR |
| 9 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-25oftrap/granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcementandstructuralsteel).withfullyautomaticmicroprocessorbasedPLCwith SCADAenabledreversibleDrumTypemixer/concreteBatchmixplant(Panmixer)etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.F.6 Page One Number 300 and B.7, Page One Number38,GROUND FLOOR |
| 10 | FIRST FLOOR |
| 11 | SECOND FLOOR |
| 12 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. BDG- 2 and 5 |
| 13 | Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (To be executed with prior approval of Superintending Engineer)Bd.A.13 Page No. 264 |
| 14 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineer inchargein layers of 15 cmto 20 cm including watering and compaction etc. complete. Bd.A.11 Page No. 263 |
| 15 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.F.8 Page No. 302 and B.7, Page No.38, GROUND FLOOR |
| 16 | FIRST FLOOR |
| 17 | SECOND FLOOR |
| 18 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-25oftrap/quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawingsorasdirectedincludingsteelcentering,plywood/steelformwork,steelprops, laying/pumping,compaction,finishing unevenandhoneycombedsurface withC.M.1:3of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade)Bd. F. 13 Page No. 305 /I.S. 456 (2000),GROUND FLOOR |
| 19 | FIRST FLOOR |
| 20 | SECOND FLOOR |
| 21 | Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting androughening the surface ifspecial finish is to be provided and curing complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSCADA enabledreversibleDrum Typemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate (Crushed sand VSI Grade)Bd.F.9 Page One Number 303 and B.7, Page One Number38,GROUND FLOOR |
| 22 | FIRST FLOOR |
| 23 | SECOND FLOOR |
| 24 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-25oftrap/granite/ quartzite/gneissmetalforR.C.C.pardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete.(Excludingreinforcementandstructuralsteel).with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Bd.F.11 Page No. 304 and B.7, Page No. 38,GROUND FLOOR |
| 25 | FIRST FLOOR |
| 26 | SECOND FLOOR |
| 27 | Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.E. 3/Page No. 288/I.S. 456 (2000),GROUND FLOOR |
| 28 | FIRST FLOOR |
| 29 | SECOND FLOOR |
| 30 | Providing and laying in situ / ready mix controlled grade of M20 of trap /granite /quartzite /gneiss metal for RCC works in cut off walls / curtain walls including necessary scaffolding, centering, compacting by vibrator, finishing and curing etc. complete. (with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer)with fine agreegates of required specifications ( VSI sand finely washed etc ), excluding reinforcement) As directed by Engineer in charge. |
| 31 | Providing and laying in situ / ready mix M-20 cement concrete of trap /granite /quartzite /gneiss metal for approach slab / Rigid pavement including compacting, finishing, curing etc. complete. (excluding reinforcement) (with reversible drum type mixer/ concrete batch mix plant (pan mixer)with SCADA with fine agreegates of required specifications (Natural sand / VSI sand finely washed etc ), cement 6.40 bags/cumt)CD.15 Page.No. 168 and B.7. Page No. 38 |
| 32 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water,Steel centering,formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADAenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc. Bd.E.4 Page No. 289 and B-7, Page No.38 |
| 33 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete..Bd.F.17, Page No. 306,GROUND FLOOR |
| 34 | FIRST FLOOR |
| 35 | SECOND FLOOR |
| 36 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete. As director by engineer incharge and BDG- 2 and 5,GROUND FLOOR |
| 37 | FIRST FLOOR |
| 38 | SECOND FLOOR |
| 39 | Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Bd. G. 7 Page 316, GROUND FLOOR |
| 40 | FIRST FLOOR |
| 41 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.Cmembersandbrickwork,ofapprovedqualityincludingfixing meshinpositionby necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. As directed by Engineer in Charge: GROUND FLOOR |
| 42 | FIRST FLOOR |
| 43 | SECOND FLOOR |
| 44 | Providing Water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make (such as Master Seal 550/ brush bond / RoffSupercrete / Webercrete / Monobond /Perma shield / Hypercrate / Master Crete M 81) and Cement in 1 : 2 proportion ( 1 litre polymer : 2 Kg. Cement) to a neatly cleaned and dust free concrete surface and upto 300 mm. over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protective mechanical cover water proof plaster 20 mm thick after sufficient curing apply IPS 40 mm to 75 mm. thick cement concrete of 1:2:3 proportion using coarse aggregate of 10 MSA and water proofing compound of approved make and polypropylene fibres @ 125 gm per bag of cement making groovr 3 to 4 mm wide & 10 mm deepin concrete, in pannels of 3m/4m or as per site condition & filling the joints with poly sulphide sealant after curing including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry, as directed and ponding the surface as directed etc.complete ; covering 10 years guarantee against leakproofness on court Fee stamp paper of Rs 100/-GROUND FLOOR |
| 45 | FIRST FLOOR |
| 46 | SECOND FLOOR |
| 47 | ProvidingandapplyingTextureplasterwithfinishingwithtexturematerial ofapproved makein 3 to 4 millimeterthickness on previously plastered surface, including Plaster Groove 6mmthicknessorTapeGrooves35to45mmthicknessorasrequired,inallposition including preparing the surface, scaffolding etc. complete. As directed by Engineer in charge. GROUND FLOOR |
| 48 | FIRST FLOOR |
| 49 | SECOND FLOOR |
| 50 | Providing internal cement plaster 20mm thick in two coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. Bd.L.4 Page No. 368,GROUND FLOOR |
| 51 | FIRST FLOOR |
| 52 | SECOND FLOOR |
| 53 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Bd. L.2 Page No. 368, GROUND FLOOR |
| 54 | FIRST FLOOR |
| 55 | SECOND FLOOR |
| 56 | Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.Bd.L.1 Page No. 367, GROUND FLOOR |
| 57 | FIRST FLOOR |
| 58 | SECOND FLOOR |
| 59 | Providing and Fixing of Mineral Fibre SuspendedCeiling System with Bioguard(Bevelled Tegular)EDGETILESWITH 15mmExposedGRID.ThetilesshouldhaveHumidity Resistance (RH) of99%, LightReflectance 90%,Thermal Conductivityk =0.052-0.057 w/m K,ColourWhite,FirePerformanceUKClass0/Class1(BS476Part6and7), in module size of 600x600 x 16mm with Anti Microbial coating on the face of the tile, suitable forGreenBuildingapplication,withRecycledcontentof34%.Thetileshallbelaidon precoated G.I. channel onXL2 Clip havinga web height of 32 mm32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner and 1200mmCrossTeeswithawebheightof32mmandaloadcarryingcapacityof7.7 Kilograms/M2 and pull out strength of 100Kilograms. . The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension systemThe Tile and Grid system used together should carry a 10 year warranty. products approved at GRIHA and BS 476 etc. complete. BDR 38.46, Ground Floor |
| 60 | FIRST FLOOR |
| 61 | METAL FALSE CEILING WITHOUT SUSPENSION SUPPORT FROM TRUE CEILING: Providing & fixing horizontal level suspended metal ceilings comprising of Metalworks F-H 600 Hook-on corridor system manufactured by Armstrong Ceiling Solutions with Rectangular panels made of 0.7mm thick Galvanised Steel (GI) of 120gsm, post coated to Global White colour, suitable for Interior applications and architectural finishes, double grid concealed system and butt joint panels. The panel width shall be 300mm, length ranging from 1500mm to 2660mm. General Specifications:Entire system to be designed for Interior applications, and concealed Grid, Butt joint panels. Panel Specifications: Material: The F-H 600 rectangular Hook-on panels to be made of galvanized steel (GI) of minimum 120gsm hot dipped galvanization (both sides included) as per IS 277 (2003), zero or minimum spangled, in minimum base material thickness of 0.7mm as per in IS:513 (1994). Dimensions: The panel Length varies between 1500mm to 2660mm, panel Width shall be 300mm. The dimensional tolerances for length shall be ±1.0m up to 1000mm L; ±1.5mm between 1001 to 2000mm L; ±2.0mm between 2001 to 3000mm L. The dimensional tolerances for width shall be ±0.5m up to 300mm W. Dimensional Tolerances for panel Thickness / panel width / panel length - to be measured in accordance with TAIM standards. Edge detail: the panels shall ha+A3ve Square Edge, with a 3mm(W) x 8mm(H) black foam gasket glued at the edges, typically on one long and one short side. All adjacent panels shall touch each other forming a butt joint and concealed grid visuals. Upturns: The short side of the panel shall have vertical upturns of minimum 30mm (H) and shall be bent appropriately bent as per the manufacturer’s specifications for providing hook-on ends. The long side shall have inside horizontal bends of 5-15mm for rigidity and vertical upturns of 40mm (for length ranging from 1251-2660mm). Surface Finish: Plain: The panels shall be in plain unperforated finish (without any acoustical backing / felt). Colour and finishes: The panel surface shall be electrostatically powder coated (post coat) on visible side after mechanical production, using RoHS compliant powder, to achieve coating thickness ranging from 60-80µ and architectural quality finish. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017, 250 hours of condensation test (as per DIN 50017 or DIN EN ISO 6270-1 Norms), UV resistance of 500 hours and 50% gloss retention (as per ASTM G 154 UVB-313 Norms). The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E (∆e) <1 measured using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523.The colour / shade to be Global White (Polyester for Interior) as approved by the Architect or Engineer-in-charge. Surface Protection: The visible panel surface shall be protected using a guard film made of LDPE of 50µ thickness, having appropriate surface adhesion (or tackiness) corresponding to surface gloss level. Light reflectance: The panel shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98. Flatness and Sag limit: Panels shall be flattened by precision leveller to minimize sag to less than Length/400mm. The difference between the two diagonal dimensions of the panel to be less than 1mm. The sag to be measured at the center in accordance with TAIM standards. Access and Plenum space: The panels to be Fully Accessible, with system height of 98mm, and would require a plenum height of a minimum 450mm clear space from bare ceiling / rigid structure for installation. Packaging: The Panels shall be packed in wooden crates of appropriate dimensions based on panel sizes. The wooden planks for rates shall have thickness of approx.15mm, width of around 4” and gap between two planks around 3”. Crates to have layer separators of 1” x 2” dimensions to prohibit load transfer on bottom panels, and the crates lifting to be 2way or 4way. The bottom of crates shall be completely closed, and the panels kept inside shall have cushioning of corrugated sheets or other appropriate material. |
| 62 | Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) 51.235 |
| 63 | Supplying and fixing of 6mm thick Exterior Compact Laminate or High Pressure Laminate of approved colour by approving authority with UV resistant Decorative colour paper on both side typically made out of multiple layers of craft papers and then impregnated with thermosetting phenolic resins, on top of it melamine treated barrier paper and decorative paper and wear layer on both the sides saturated with melamine resins and then covered with UV resistant acrylic resin layer which makes it extremely durable and weather resistant compressed together onextremely high pressure and hardened with electron beam curing to get the total desired thickness of 6mm matching European standard specification as per EN 438 -part 6, protected with 60 Micron protective peel-off film on both side which in no case leave any adhesive mark over the panel surface after it is peeled off. Fixing of the same to be done on a supporting frame of 50 mm X 5 mm X 3 mm powder coated aluminium box section to be spaced horizontally and vertically in 600mm X 600mm grid and fixed to building structure as per design through 50mmX50mmX mm 5 mm MS angle bracket prefixed to masonry slab or columns with Hilti make anchor fastener along with all related hardware and fixtures. The panel should then be fixed on the Aluminium section with the help of pure polyester exterior grade colour coating rivets as per architectural drawings or as directed by Engineer-in-charge. Each panel should be riveted on substructure maintaining a gap of 6mm on all the sides between each Panel for Air circulation and expansion and contraction as per installation specifications provided by the manufacturer. The cost shall include all expenses related to storage, material handling, lifting, freight, labour, scaffolding etc as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) 51.236 |
| 64 | Brick work in gauged arches in superstructer above plinth level in up to floor 5 level in C.M. (1:3) Including centring and suttering complete for spain up to 6 M with common burnt ply fps ( Non Moudulal) brick of class designation 7.5 also including pointing with cement mortor 1: 3 for brick work scaffloding curing sbr polymer mix morter and two coat of calist silrepelland for water proofing ; |
| 65 | Brick work in gauged arches in superstructer above plinth level in up to floor 5 level in C.M. (1:3) Including centring and suttering complete for spain above 6 M with common burnt ply fps ( Non Moudulal) brick of class designation 7.5 also including pointing with cement mortor 1: 3 for brick work scaffloding curing sbr polymer mix morter and two coat of calist silrepelland for water proofing |
| 66 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete also including pointing with cement mortor 1:3 for brick workscaffloding curing sbr polymer mix morter and two coat of calist silrepelland for water proofing |
| 67 | providing &appylingflex stone wall stamping texture with stone clour on all exposed face of wall of brick , concertre surface making conner &champerining as per requriment&requriedspecfiction filling in joints / grove with approved quality of addessive inculding all material labour ,transportation ,scaffolding &as per dricted by enginner in chage /Architect etc complete |
| 68 | Providing patti/ band 100 mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. As directed by Engineer in charge. GROUND FLOOR |
| 69 | FIRST FLOOR |
| 70 | SECOND FLOOR |
| 71 | Providingand applyingtwocoatsof exterioracraylicemulsion paintconfirmingto corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces includingcleaning,preparingtheplastersurface,applyingprimercoat,scaffoldingif necessary , and watering the surface for two days etc complete.GROUND FLOOR |
| 72 | FIRST FLOOR |
| 73 | SECOND FLOOR |
| 74 | Providing and applying Royale Luxury Emulsion of approved make on internal wall surface asdetailedbelowScrappingforsurfacewithemerypaperandwipecleanforarea. wall primer withbrushby adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dryfor 6 to8 hoursAfter applying acrylic wall putty with appropriate prpportion of water of allow to dry for period of4to6hoursofactivity.Scrappingwithemerypaper andwipecleanApplying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45%or 65 to 70 % by roller. (With prior approval of S.E.) As directed by Engineer in charge.GROUND FLOOR |
| 75 | FIRST FLOOR |
| 76 | SECOND FLOOR |
| 77 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade withfullmoulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaningetc. complete.Bd. M.22 B/Page No. 390,GROUND FLOOR |
| 78 | FIRST FLOOR |
| 79 | SECOND FLOOR |
| 80 | Providing and laying vitrified matt fininsh tileshaving size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring. Bd.M.12 Page No. 385, GROUND FLOOR |
| 81 | FIRST FLOOR |
| 82 | Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete. GROUND FLOOR |
| 83 | FIRST FLOOR |
| 84 | SECOND FLOOR |
| 85 | Providing and laying Antiskid Ceramic tiles of approved qualityof size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.Bd. M-12 page No. 385, GROUND FLOOR |
| 86 | FIRST FLOOR |
| 87 | Providing and laying ceramic tiles ofhaving size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Bd.M.13 Page No. 386.GROUND FLOOR |
| 88 | FIRST FLOOR |
| 89 | Providing and laying chequered tiles of approved qualityof size 30 cm x 30 cm, confirming tocorrespondingI.S.forflooringinrequiredpositionlaidonabedof1:4cementmortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Bd. M-12 page One Number 385, GROUND FLOOR |
| 90 | Providing and fixing black kadappa stone as shelves 25mm. thick machine polished, extending the polish upto 20 cm width on lowerside, rounding corners, laying in position jointing with bedding cement mortar 1:4 proportion curing etc etc. complete.Bd.M.29 Page No. 391,GROUND FLOOR |
| 91 | FIRST FLOOR |
| 92 | Providing and preparing kitchen otta up to 75 cm width,made up from 30 mm thick and 75 cm high vertical support for kadppa at 1 m. c/c of 25 mm thick both side polished kadappa middle shelf and bottom of 20 mm thick one side polished kadappa with facia patti of 20 x 50 mm kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaningetc. complete. Bd.M.35C / Page No. 393, GROUND FLOOR |
| 93 | FIRST FLOOR |
| 94 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete, As directed by Engineer in charge,FIRST FLOOR |
| 95 | Providing and fixing Country cut teak wood double or single leaf second class fully panelled door shutter with 35mm thick style and rail with 25 mm thick panels with openable fan light as per detaileddrawings. Excluding the door frame 60mm x 100mm stainless steel fixtures andfasteningandfinishingthewoodworkwithoilpainting3coats.(Excludingthedoor frame) BD-T-7 and 8 Page One Number 481-82,FIRST FLOOR |
| 96 | Providingandfixingsingleleafpanelleddoorshutterwithoutfanlightandshutter35mm thick as per drawing consisting of T.W. top rail size 100mm x 35 mm and bottom and lock rail 200mm x 35mm insert panel 12 mm thick commercial ply faced T.W. particle board with phenolformaldehydesyntheticresin(GenerallyconfirmingtoISI3097)excludingframe, including stainless steel fixtures fastening and T.W. beading at junction of panels inserts and as instructed by the Engineer in charge including 3 coats of oil painting etc. complete.GROUND FLOOR |
| 97 | FIRST FLOOR |
| 98 | Providingandfixinginposition,Doubleshutteredaluminiumextrudedpowdercoated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75mm ,3.18mm thickandshuttercomprising ofpowder coatedsection having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottompanels etc. , I.S.I. mark , heavy duty, Hydraulic floorspringof 150Kilogramcapacity , having heavy duty concealedlock, necessary beading, glazing clips, PVCgaskets,250mmlengthaluminiumtowerbolts,150mmdia.padhandle,etc.asper detaileddesignanddrawingorasdirectedbyengineerinchargeincludingallmaterials, labours, and equipment etc.completeAs directed by Engineer in charge.GROUND FLOOR |
| 99 | FIRST FLOOR |
| 100 | Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc As directed by Engineer in charge. GROUND FLOOR |
| 101 | FIRST FLOOR |
| 102 | Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with boxAs directed by Engineer in charge.GROUND FLOOR |
| 103 | FIRST FLOOR |
| 104 | SECOND FLOOR |
| 105 | Providing and fixing in position Mild steel fixed staggered ( Z Type ) Ventilator as per detailed drawing with hot deep zink coating including fabricating with Mild steel \"Z \"Section of size 20mm x 25 mm and 3 mm thick at weight 1.42 Kg/Rmt,with stainless steel mosquito net of 304 Grade,4 mm thick float glass ?as directed by Engineer In charge including necessary welding, grinding, two coats of oil paint etc.complete. GROUND FLOOR |
| 106 | FIRST FLOOR |
| 107 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.Bd.U.1 Page No. 537,GROUND FLOOR |
| 108 | FIRST FLOOR |
| 109 | SECOND FLOOR |
| 110 | Full Height Partitions in Glass finish Providing and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powdercoated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 5mm thk. Non Toughened Glass on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing.GROUND FLOOR |
| 111 | FIRST FLOOR |
| 112 | ProvidingandfixinginpositionGypsum boardfalseceilingwith12.5mm thickGypsum boards, screwed/fixedtotheunderstructureofsuspendedG.I.Gridconstructedand suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum centertocenterdistanceof600milimetreperimeterchannelandintermediatechannelsat maximumcentertocenterdistance1200milimetregalvanizedgridshouldbefixedto reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed inall respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.As directed by Engineer in charge.GROUND FLOOR |
| 113 | FIRST FLOOR |
| 114 | Providing and fixing orissa type colour glazed earthenware 625 x 450 mm. w.c. pan including trap, C.I. soil and vent pipe upto the out side face of wall including 100 mm. dia. C.I. plug, bend,15mm.thick10litrePVCflushingcisternwithallnecessarypipeconnectionetc. complete.As directed by Engineer in charge. GROUND FLOOR |
| 115 | FIRST FLOOR |
| 116 | Providing and fixing European type Colour glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 liter enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jetandfittingincludingcuttingandmakinggoodtothewallsandfloorstestingetc. complete.( prior approval of sample and brand by Ex. Engineer is necessary before use)As directed by Engineer in charge.GROUND FLOOR |
| 117 | FIRST FLOOR |
| 118 | Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providingT.W.gutties etc. complete Specfications, GROUND FLOOR |
| 119 | FIRST FLOOR |
| 120 | Providing and fixingWhite glazed with bottle trap earthenware Wash Hand Basin of 55x40 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete. BDV.-30Page No.616, GROUND FLOOR |
| 121 | FIRST FLOOR |
| 122 | Providingandfixingcolouredglazedearthenwarelippedflatback/cornertypeurinalwith PVC5litersflushingcisternwithfittings,capacitywithfittings,inletpipeandstoptap, brackets for fixing the cistern, P.V.C. flush pipe withfittings including lead soil pipe, lead trap and soil pipe connection up to the outside face of the wall.Bd.V.27 Page One Number 564,GROUND FLOOR |
| 123 | FIRST FLOOR |
| 124 | Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. As directed by Engineer in charge. GROUND FLOOR |
| 125 | FIRST FLOOR |
| 126 | Providing andfixing 10cm C.I.NahaniTrapincludingC.I.gratingbendandpiece ofC.I. pipe upto the outside face of the wall complete. Bd.V.32 Page One Number567, GROUND FLOOR |
| 127 | FIRST FLOOR |
| 128 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.BD.V 5 page 551,GROUND FLOOR |
| 129 | FIRST FLOOR |
| 130 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.BD.V 5 page551, GROUND FLOOR |
| 131 | FIRST FLOOR |
| 132 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. BD.V 5 page 551,GROUND FLOOR |
| 133 | FIRST FLOOR |
| 134 | Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Bd.V.8 Page No. 554, GROUND FLOOR |
| 135 | FIRST FLOOR |
| 136 | ProvidingandfixingC.P.pillarcocklongneckwithaeratorofapproedmakeincluding necessary sockets/union nut etc. complete.As directed by Engineer in charge, GROUND FLOOR |
| 137 | FIRST FLOOR |
| 138 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete.As directed by Engineer in charge, GROUND FLOOR |
| 139 | FIRST FLOOR |
| 140 | Providing and fixing C.P. sink cock with raised J\" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. completeAs directed by Engineer in charge, GROUND FLOOR |
| 141 | FIRST FLOOR |
| 142 | Providing and fixing H.D.P container one piece moulded water tank made out oflowdensitypolythylerandbuiltcorrugationincludingofdeliveryuptodestination hoisting andfixing of accessories such as inlet, outlet overflow of alltanks capacityabove 1000 to 20,000 litres As directed by engineer-in-charge.FIRST FLOOR |
| 143 | Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Bd.V.43, Page No. 574,GROUND FLOOR |
| 144 | Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Bd.V.43, Page No. 574, GROUND FLOOR |
| 145 | Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.As directed by Engineer in charge. GROUND FLOOR |
| 146 | FIRST FLOOR |
| 147 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper. As directed by Engineer in charge. GROUND FLOOR |
| 148 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent ofclorophyrifosper square metre of surface area covering ten years guarantee on bond paper. .As directed by Engineer in charge. GROUND FLOOR |
| 149 | Providing and laying perforated PVC 160 mm dia pipe in proper line,leveland slope including necessary material fitting etc. complete. As directed by Engineer in charge.GROUND FLOOR |
| 150 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.Bd.V.41, Page One Number 573,GROUND FLOOR |
| 151 | RWH - Recharge PitProviding andconstructing rechargepitof2.0m deepand1.0m diaofpre-castRCCrings with6.5\"diax25mdeepborewellatthefloorofrechargepitincludinginstallationof combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mmthicksidefillingaroundoutsideofRCCrings(annularspace)with40mmsize bouldersincludingfillingofrechargepitupto0.5mdepthwith25-75mmcleanwashed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.)includingnetlonmeshbetweeneachgravel/fineaggregate(naturalsand/crushedsand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation& backfilling as shownin the drawing.The rate shall be inclusive of alllabour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All materialshouldbeofapprovedmake.Allworkscompleteasperthedrawing,technical specification and direction of the Engineer in charge..As directed by Engineer in charge.GROUND FLOOR |
| 152 | ProvidingandfixingP.V.C.Rainwaterpipesof110mmouterdiameterandhavingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket withsolventcementandproperlyrestingtheshoeofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. As directed by Engineer Incharge. GROUND FLOOR |
| 153 | FIRST FLOOR |
| 154 | Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. As directed by Engineer in charge.GROUND FLOOR |
| 155 | FIRST FLOOR |
| 156 | Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. As directed by Engineer in charge. GROUND FLOOR |
| 157 | FIRST FLOOR |
| 158 | Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete.Bd.V. 12 Page No. 556,GROUND FLOOR |
| 159 | FIRST FLOOR |
| 160 | Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. Bd.V.46, Page No. 576,GROUND FLOOR |
| 161 | Providing and fixing during laying in RCC Slabrectangular 2 mm thickM.S. sheet fan hook box ofsize 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and painting to exposed surface.As directed by Engineer in charge.GROUND FLOOR |
| 162 | FIRST FLOOR |
| 163 | Providing and fixing 90 cm x 60 cm Granaite plate engraving 10 cm. height letter, figures including painting the lefters/figures with approved colour and shade complete. Bd.W.7 Page No.586,GROUND FLOOR |
| 164 | Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kilogram/sq.m of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaning etc. complete. (using 100% crushed sand)Bd. M-12 page Number 385,GROUND FLOOR |
| 165 | Providing and Fixing mat finish stainless steel (of 302 grade ) railing with toppipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) As directed by Engineer Incharge, GROUND FLOOR |
| 166 | FIRST FLOOR |
| 167 | SECOND FLOOR |
| 168 | Providing andfixing in positionUPVC ultra violet stabilized110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete.As directed by Engineer in charge.GROUND FLOOR |
| 169 | Providing and fixing M.S. grill door 24 Kilogram/ One Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc. GROUND FLOOR |
| 170 | SECOND FLOOR |
| 171 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, teesetc.asperdetaileddesignanddrawingsorasdirectedincludingcutting,fabricating, hoisting,erecting,fixinginpositionmakingriveted/bolted/weldedconnectionswithout connecting plates, braces etc. andincluding one coat of anticorrosive paint andover ittwo coats of oil painting of approved quality and shade etc. Bd.C.2 Page One Number 275, SECOND FLOOR, |
| 172 | Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 22 mm thick of 1200mm (min.) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional IR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with a continuous aluminium I Beam holding the base of the standing seam along the length of the panel & fixed with purlin with self-drilling hex head screws offering best stability with a pull-out load of min. 21000N (21KN) tested as per ISO 6892:1998 and IS 1608: 2005., as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.9 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineer in charge. Colour: As per approval The 22mm thick panels shall be used for a roofing height of upto 55 mtrs. SECOND FLOOR |
| 173 | Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. MORTH 801 GROUND FLOOR |
| 174 | Providingandfixing90cmx60cmMarbleplateengraving10cm.heightletter,figures including painting the lefters/figures with approved colour and shade complete.Bd.W.7 Page One Number586,GROUND FLOOR |