| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 2 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 3 | Brick masonry with F.P.S. bricks of class designation 75 infoundation and plinth with bricks Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 4 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
| 5 | Providing and laying in position specified grade ofcement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. Supply & Stacking good earth at site complete including loading unloading & transporation etc. Good soil of Earth |
| 7 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 8 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 9 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Columns, pillars, posts and struts etc. |
| 10 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 11 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix Add extra for providing richer mixes respectively at all floor levels Providing M-25 grade concrete by usingcement as per codal provision instead ofM-20 grade design mix. |
| 12 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 13 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 14 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Partly fixed and partly openable [ fixed area not to exceed 33%] |
| 15 | Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint Extra for double leaf shutters. |
| 16 | Providing and fixing Square bars or other flat welded to window, ventilatiors etc. |
| 17 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 18 | 6 mm cement plaster to ceiling of mix 1:3 (1 cement :3 corse sand) |
| 19 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 12mm thick. |
| 20 | External Plaster -Plaster On New Surface On Walls In Cement Sand Mortar 1:6 IncludingRacking Of Joint Etc. Complete Fine Finished. 20 mm thick |
| 21 | Making grooves as per design in plaster 10mm to 20mm wide |
| 22 | Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm |
| 23 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm |
| 24 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). |
| 25 | Grading roof for water proofing treatment withwater proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 26 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 27 | Providing & laying Chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of C.M. 1:4 : Ordinary cement without any pigment. Add extra for non slipping 9-12 mm ironite topping tiles |
| 28 | Providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. |
| 29 | Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete |
| 30 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer. |
| 31 | Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. On new work |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on New Work |
| 33 | Lettering with black Japan paint of approved brand and manufacture. |
| 34 | P&F rigid 110 mm dia pvc pipe class IInd (4kg./cm2) approved quality make including jointing the pipe with solvent cement rubber rim & lubricant . |
| 35 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:Bend 87.50, 110mm dia |
| 36 | Precast terrazzo tiles of approved make 20mm thick with marble chips of size upto 6mm in skirting & risers, treads of steps and dados 12mm thick cement plaster 1:3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of : Dark shade using ordinary cement. |
| 37 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. Short point (up to 3 mtr.) |
| 38 | Medium point (up to 6 mtr.) |
| 39 | Long point(up to 10 mtr..) |
| 40 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. On board |
| 41 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 25 mm |
| 42 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 43 | P & F 1.00mm thickM.S. Recessed concealed box,round of size 150 mm dia, depth 100 mmcomplete as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 44 | Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 1200 mm sweep BEE 3 Star |
| 45 | Providing & Fixing of IS 11037:1984markednon modular socket size flush type 180 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 5 step fan regulator 2 Module |
| 46 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Single pole MCB (With B/C curve tripping Characteristics).6 A to 32 A rating |
| 47 | Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 10.0 sqmm |
| 48 | Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . Down Road |
| 49 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 1170mm(+/-10%) LED batten with min. lumen output 2200 lm |
| 50 | Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted complete with din rail making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. Suitable for Six / Eight module for MCB/ RCCB |
| 51 | Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. Double pole isolator 63 A rating |
| 52 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 53 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 54 | Brick work with common burnt clay F.P.S. (Non Modular) bricks of class designation 7.5 infoundation and plinth with Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 55 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
| 56 | Providing and laying in position specified grade ofcement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 57 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. Supply & Stacking good earth at site complete including loading unloading & transporation etc. |
| 58 | Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 59 | Half brick masonry with Non modularflyash brick conforming to IS: 12894 :2002of class designation 10.0 in Superstructure , above plinth level upto floor fivelevel. Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 60 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 61 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 62 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (\"Original producers\" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 63 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 64 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable) |
| 65 | Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 66 | 6 mm cement plaster to ceiling of mix 1:3 (1 cement :3 corse sand) |
| 67 | Internal Plaster--Plaster On New Surface On Walls In Cement Sand Mortar 1:6 IncludingRacking Of Joint Etc. Complete Fine Finished. 12mm Thick |
| 68 | External Plaster -Plaster On New Surface On Walls In Cement Sand Mortar 1:6 IncludingRacking Of Joint Etc. Complete Fine Finished. 20 mm thick |
| 69 | Dry brick on edge flooring in required pattern with bricks of class designation 75 on a bed of 12 mm mud mortar including filling joints with River sandcomplete. |
| 70 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). |
| 71 | Providing & laying Chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of C.M. 1:4 : Dark shade using ordinary cement. Add extra for non slipping 9-12 mm ironite topping tiles |
| 72 | Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) |
| 73 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 74 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 75 | Grading roof for water proofing treatment withwater proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 76 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 77 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer. |
| 78 | Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect including scaffolding and safety provision New Work |
| 79 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on New Work |
| 80 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)20mm nominal outer dia pipes |
| 81 | 25 mm nominal outer dia pipes |
| 82 | P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: SIZE 530*410MM |
| 83 | Providing & Fixing premium qulaity WVC Urinal with PVC waste pipe, dome couplings, concealed iron brackets or screws etc. completeMini stallsize 455*385*350 mm. |
| 84 | P & F WVC wash basin (1st quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (IS : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make,25 mm G.I. waste pipe complete including cutting & making good the wall.: 450 x 300 mm |
| 85 | P&FFlushCock / FlushValve (IS :9758Mark)forWCofapproved quality make :(-do-) concealed 25mm nominal bore. |
| 86 | P & F Bib Cock (IS : 8931 Mark) superior quality of approved make.C.P. Brass 400 gm, 15 mm nominal bore. |
| 87 | P & F Inlet connection (Angle Valves) Superior quality of approved make C.P. Intel connection 15 mmbrass(IS : 8931) |
| 88 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia |
| 89 | P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556mark). Of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall:PVC with PVC bend and superior internal fittings as per IS :7231 |
| 90 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5110mm dia |
| 91 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant Plain floor trap 110 mm dia |
| 92 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant P-Trap 110 mm dia |
| 93 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant Vent Cowel 110 mm dia |
| 94 | S/F RCCmain hole covers with frame of approved make (Light Duty) Size 450x450 mm |
| 95 | P/F Grating of Approved quality Stainiese Steet sheet size 125 mm dia |
| 96 | Construction of Soakage well in alltypes of soil of approved drawing , top 90 cm portion in 450 mm thick with cement mortar 1:6 80 mm stone slab coveringjointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C. flooring earthwork etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 Mtr.inner dia 90 cm & 10 to 12 m deep |
| 97 | Construction of Chamber in all types of soil with 300 mm thick masnory in CM. 1 : 6, 100 mm thick C.C. 1 : 5 : 10 in foundation , 20 mm thick inside plaster in Cm 1 : 6, finished with floating neat cement 50 mm thick M-15 grade C.C. flooring earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 Mtr.Inside size 450 x 450 mm depth upto 0.5 M & 5 Kg CI cover with frame. |
| 98 | P & F Ball Cock (IS : 1703 Mark) with Rod & P.V.C. Ball complete.Brass wt. 300 gm, 15 mm |
| 99 | P & F 15 mm dia connection pipe of approved quality make PVC Pipes with nuts 450 mm. |
| 100 | P & F Stop cock (IS:8931 Mark),Superior quality and of approved mark: Brass 400 gm. 15 mm nominal bore |
| 101 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)15 mm |
| 102 | 32mm nominal outer dia pipes |
| 103 | P & F PVC Storage Tank ISI Marked ( IS: 12701) indicating the BIS license No. of approved make with cover, 25mm dia 1 M long G.I. overflow pipe & 25 cm longwash out pipe with plug & socket including making connection etc. complete of approved design 500 litres capacity |
| 104 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 105 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 106 | Brick work with common burnt clay F.P.S. (Non Modular) bricks of class designation 7.5 infoundation and plinth with Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 107 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
| 108 | Providing and laying in position specified grade ofcement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 109 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. Supply & Stacking good earth at site complete including loading unloading & transporation etc. |
| 110 | Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 111 | Half brick masonry with Non modularflyash brick conforming to IS: 12894 :2002of class designation 10.0 in Superstructure , above plinth level upto floor fivelevel. Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 112 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 113 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 114 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (\"Original producers\" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 115 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 116 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable) |
| 117 | Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 118 | 6 mm cement plaster to ceiling of mix 1:3 (1 cement :3 corse sand) |
| 119 | Internal Plaster--Plaster On New Surface On Walls In Cement Sand Mortar 1:6 IncludingRacking Of Joint Etc. Complete Fine Finished. 12mm Thick |
| 120 | External Plaster -Plaster On New Surface On Walls In Cement Sand Mortar 1:6 IncludingRacking Of Joint Etc. Complete Fine Finished. 20 mm thick |
| 121 | Dry brick on edge flooring in required pattern with bricks of class designation 75 on a bed of 12 mm mud mortar including filling joints with River sandcomplete. |
| 122 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). |
| 123 | Providing & laying Chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of C.M. 1:4 : Dark shade using ordinary cement. Add extra for non slipping 9-12 mm ironite topping tiles |
| 124 | Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) |
| 125 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 126 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 127 | Grading roof for water proofing treatment withwater proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 128 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 129 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer. |
| 130 | Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect including scaffolding and safety provision New Work |
| 131 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on New Work |
| 132 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)20mm nominal outer dia pipes |
| 133 | 25 mm nominal outer dia pipes |
| 134 | P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: SIZE 530*410MM |
| 135 | P & F Europeantype white glazed vitreous china 1st quality W.C. (IS : 2556 Mark) including cutting and making good the wall and floor |
| 136 | P & F WVC wash basin (1st quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (IS : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make,25 mm G.I. waste pipe complete including cutting & making good the wall.: 450 x 300 mm |
| 137 | P&FFlushCock / FlushValve (IS :9758Mark)forWCofapproved quality make :(-do-) concealed 25mm nominal bore. |
| 138 | P & F Bib Cock (IS : 8931 Mark) superior quality of approved make.C.P. Brass 400 gm, 15 mm nominal bore. |
| 139 | P & F Inlet connection (Angle Valves) Superior quality of approved make C.P. Intel connection 15 mmbrass(IS : 8931) |
| 140 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia |
| 141 | P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556mark). Of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall:PVC with PVC bend and superior internal fittings as per IS :7231 |
| 142 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5110mm dia |
| 143 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant Plain floor trap 110 mm dia |
| 144 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant P-Trap 110 mm dia |
| 145 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant Vent Cowel 110 mm dia |
| 146 | S/F RCCmain hole covers with frame of approved make (Light Duty) Size 450x450 mm |
| 147 | P/F Grating of Approved quality Stainiese Steet sheet size 125 mm dia |
| 148 | Construction of Soakage well in alltypes of soil of approved drawing , top 90 cm portion in 450 mm thick with cement mortar 1:6 80 mm stone slab coveringjointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C. flooring earthwork etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 Mtr.inner dia 90 cm & 10 to 12 m deep |
| 149 | Construction of Chamber in all types of soil with 300 mm thick masnory in CM. 1 : 6, 100 mm thick C.C. 1 : 5 : 10 in foundation , 20 mm thick inside plaster in Cm 1 : 6, finished with floating neat cement 50 mm thick M-15 grade C.C. flooring earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 Mtr.Inside size 450 x 450 mm depth upto 0.5 M & 5 Kg CI cover with frame. |
| 150 | P & F Ball Cock (IS : 1703 Mark) with Rod & P.V.C. Ball complete.Brass wt. 300 gm, 15 mm |
| 151 | P & F 15 mm dia connection pipe of approved quality make PVC Pipes with nuts 450 mm. |
| 152 | P & F Stop cock (IS:8931 Mark),Superior quality and of approved mark: Brass 400 gm. 15 mm nominal bore |
| 153 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)15 mm |
| 154 | 32mm nominal outer dia pipes |
| 155 | P & F PVC Storage Tank ISI Marked ( IS: 12701) indicating the BIS license No. of approved make with cover, 25mm dia 1 M long G.I. overflow pipe & 25 cm longwash out pipe with plug & socket including making connection etc. complete of approved design 500 litres capacity |
| 156 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils |
| 157 | PCC in foundation :Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:3:6(1 cement:3 Coarse sand :6 graded stone aggregate 20 mm nominal size). |
| 158 | Brick masonry with F.P.S. bricks of class designation 75 infoundation and plinth with bricks Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 159 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 160 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five evel for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 161 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 162 | External Plaster : Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished 20 mm thick |
| 163 | Grading roof for water proofing treatment withwater proffing compound: Cement concrete 1: 2: 4 (1 cement: 2 Course sand: 4 Greded stone aggregate 20 mm nominal size) |
| 164 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. |
| 165 | Exterior finishing :- Finishing walls with acrylic smooth exterior paint of required shade including all scaffolding. New work (two or more coat applied @1.67/ ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm.) |
| 166 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc omplete 75mm thick with 20mm thick nominal size aggregate. |
| 167 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils |
| 168 | PCC in foundation :Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8(1 cement:4 Coarse sand :8 graded stone aggregate 40 mm nominal size). |
| 169 | PCC in foundation :Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:3:6(1 cement:3 Coarse sand :6 graded stone aggregate 20 mm nominal size). |
| 170 | Brick masonry with F.P.S. bricks of class designation 75 infoundation and plinth with bricks |
| 171 | External Plaster : Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished 20 mm thick |
| 172 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 173 | Lettering with black Japan paint of approved brand and manufacture. |
| 174 | Wall painting with Royal Play paint with various types of designs as approved of approved brand and manufacture to give an even shade including all scaffalding. Two or more coats on New work including reparation of base with primer, putty lippy etc. Complete in all respect |