| 1 | Taking down cement plaster any description from roof slab, stone wall, brick wall parapets including raking out joints hacking for key and scrubbing down with water etc(for roof treatment) complete all as specified. |
| 2 | M&L rendering 15mm thick on Brick masonary in internal surfaces in CM 1:4 finished even and smooth without using extra cementcomplete all as specified and directed. |
| 3 | M&L for preparation of newly plastered surfaces and applying three coats of white wash on walls all as specified and directed. |
| 4 | M & L for complete removal ofexisting treatment of old plastered surfaces, preparation of wall and applying two coats of cement base paint complete all as specified and directed. |
| 5 | M&L complete removal of existing treatmentapplying two coat of Oil Bond distermper white or tinned over an coat of primer on walls, etc all as specified and directed. |
| 6 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness inclduding cover fillets.Complete all as specified and directed by Engr-in-charge. |
| 7 | S&F hangers 6mm dia G.I. (upto 1200mm length ) adjusting level, size of grid 605mm X605mm, fixed to roof slabs mean of ceilling cleats made out of GI flat 40X3mm size 60 mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. |
| 8 | S&F anodised aluminium snap grid frame work for suspended false ceiling ,size of grid 605mm X605mm complete all as specified. |
| 9 | S&F Non asbestos fiber cement building board 6mm thick ,fixed to aluminium or MS galvanised snap grid frame work with screw in ceiling complete all as specified. |
| 10 | M&L for 75mm thick cement concrete (1:3:6) type C1 (using 20 mm well graded stone aggregate) as in plinth protection, finishing cement concrete surfaces fair and even without using extra cement, laid in alternate panels, including forming joints at 2 mtr intervals and filled with bitumen mastics, complete all as specified and directed. |
| 11 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings. completeall as specified and directed by Engr-in-charge. |
| 12 | S & F for Pre- painted galvalume aluminum zinc coating GI based corrugatedsteel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified all as specified and directed. |
| 13 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof , ridge / valley gutter, fixed with self tapping screws as specified |
| 14 | M & L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint (first quality) complete all as specified and directed. |
| 15 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as spesified and directed. |
| 16 | S & F Mild steel work as inroof trusses (framed), Trussesd, purlins, rafter, crane grantries, rails and framings and heavy bracket framing (Beam,tee, angle, channel or flat sections) confrming to Fe 410-Wincluding welidng cleats,distance pieces etc.completeall as specified and directed by Engr-in-charge. |
| 17 | M & L for preparation of new steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint (first quality) over a coat of red oxide primer, complete all as specified and directed. |
| 18 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises |
| 19 | Demolition of cement concrete(unreinforced ) in ground floors and pavings not exceedidng 15cm thickness(below ;or aboved ground level) all as specified and directed. |
| 20 | M &L for 25 mm thick PCC 1:2:4 type B0 (Using 12.5mm gradedstone aggregate) as in sub base in floors complete all as specified and directed by Engr-in-charge |
| 21 | M&L for 10mm thick backing coat in cm 1 :4 for layingtiles on walls complete all as specified and directed by Engr-in-charge |
| 22 | S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but notexceeding 0.11 sqm, in floors etc, setand jointed in neat cement slurry and pointed in white or Coloured cement to match shade of the tilesincluding 15 mm thick screed bed or bedding layer of mortar for laying floor finishes in cm 1:4. Tiles shall be conferming to IS - 15622, 2006, Gp-B II with average water absorption between 3% to 6% length, width and straitness of sides +10% (Max daviation). Thickness +5% (Max daviation). Centre & Edge curvature warpage +.5% (Max daviation). Breaking strength 1000N (Minimum) and minimum 95% tiles shall be free from visible defect. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 23 | M&L Glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match. Tiles shall be confirming to IS - 15622, 2006, Gp-B II with average water absorption between 3% to 6% length, width and straitness of sides +10% (Max daviation). Thickness +5% (Max daviation). Centre & Edge curvature warpage +.5% (Max daviation). Breaking strength 1000N (Minimum) and minimum 95% tiles shall be free from visible defect. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 24 | M & L Vetrified Ceramic colour tiles light shade 10 mm thick(square/ rectagular) polished, area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm , in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer of mortar for laying floor finishes in cm 1:4 complete all as specified and directed. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 25 | Taking up or down 15mm bore steel water tubing & connections, including cleaning for refixing or offering credit as per schedule of credit all as directed. |
| 26 | All as per item No 25herein before but 20mm bore |
| 27 | S&F 15mm bore Galvanised steel tubes,\"medium grade\"with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engr In Charge.. |
| 28 | S&F 20mm bore Galvanised steel tubes,\"medium grade\"with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engr In Charge. |
| 29 | S&F in repair vitreous china wash basin , white , flat back, size 630x450mm excluding taps, waste chain and plug and porcelain stopper but including brackets , waste coupling , waste pipe complete all as specified and directed.Make-Cera |
| 30 | S&F in repairs for Vitreous China, pedestal patternwhiteincluding trap set with concrete includingSeat and cover,10ltrs low level fluslhing cistern with flush pipe complete all as specified and directed by engr-in-charge. |
| 31 | S&F in repair 10 ltr capacity PVC valveless , syphonic action type flushing cistern, low level, white, with inlet ball valve, float and handle including brackeet and 32mm dia flush pipe of polyethylene of low or high density for low level cistern complete all as specified and directed. |
| 32 | S&F in repair 15 mm dia pillar taps, cast copper alloy, with capstan heads, chromium plated fancy type , screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" woth long shanks and flynuts, screwed for iron pipe complete all as specified and directed. |
| 33 | S&F in repair 15mm fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down , screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 34 | S&F in repair 15mm dia stop valve chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for union complete all as specified and directed. |
| 35 | S&F 600mm x 450mm bevelled edge mirror or selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chroimium plated brass screws and cup washers complete all as specified and directed. |
| 36 | S&F inBrass chromium plated tubular towel rail, 20mm dia , D type 60cm long between flanges complete all as specified and directed. |
| 37 | S & Fin repairchromium plated shower rose 125mm size with or without swivel joint any size incl fixing to steel pipe or union complete all as specified and directed. |
| 38 | S & F in repair 20 mm dia., Aluminium alloy anodised curtain rails with brackets fixed in repair |
| 39 | S&F in repairs PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. |
| 40 | S&F in repairs PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and as directed. |
| 41 | M&L for 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm gradedstone aggregate) in sub base of flooring/ hard standing. |
| 42 | M&L For Machine cut kota stone slab flooring of size 550x550 mm and 18-20mm thick over and incl 20mm thickcement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 43 | M &L Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar including backing coat of 10mm thick cement mortar 1:3 and jointed as specified and directed. |
| 44 | M & L for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications |
| 45 | S&F Aluminium Partition wall of section as in frame size 63.5 X 38.1 x 2mm thick of make Jindal or Equivalent, incl 8mm thick Glass / 12mm thick prelaminated particle boardpaneling including MS Channel ( Size of paneln.exc 1.5 Sqm each ) and all necessary fittings all as approved by Engr in charge. |
| 46 | Taking down chowkats or frames with shutter(without taking off shutters from the frames) not exc 1.5 sqm each and removing from site complete all as sepcified and directed. |
| 47 | S&F in Powder coated aluminium sliding windowwith shutter styles 40mm x20 mm sheet thickness 1.2mm two shutter of glass and one shutter of wire mesh consisiting ofStainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, frame (chowkat) of window shall 91.80mmx31.75mmx1.2mm thick section (three track) with or without rebate including 5 mm thick tinted glass fixed with aluminium beads locking arrangement with each shutter all as directed by the Engineer-in-Charge.Note: Size of window shall be as per site requirement. |
| 48 | Taking down chowkhats or frames with shutters exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutters from the frame) complete all as specified & directed. |
| 49 | S&F aluminium colour powder coated anodised door and shutter or double leaf glazed/pre laminated board exterior quality partly glazed/pre laminated board exterior quality partly glazed panels fabricated including aluminium anodised beading rubber and packing materials and shall be drilling in existing wall and thrust bolt suitable size includingfixing of aluminium hingesof any description complete comprising the following:-(a) Aluminium colour anodised door frame section 101.60x44.45x1.93 mm fixed as per spd(b) Aluminium colour anodised verticle section inshutter 85x44.45x2 mm as per spd(c) Aluminium colour anodised top & style shutter section 95.25x44.45x2.00 mm as per spd (d) Aluminium clolour anodised handle 02 Nos in each shutter 200 mm long as spd(e) Aluminium clolour anodised middle lock rail/bottom rail section 150x44.x2.65mm cat No 20002 (f) Floor spring (g) Six lever mortice lock brass125 mm(h) 12mm thcik particle board (pre laminated both face) exterior grade ISI Marked(j) Tinted glass/plain glass (colour) 5mm thickNote :-glass or full panel shall beprovided as per direction of Engr-in-Charge |
| 50 | Taking down carefully copper/aluminium point wiring from existing points (light, fan, socket or power) alongwith compete fittings such as switches ,ceiling rose, pendent holder, sketch fitting & regulator etc. includingmaking good to the disturbed surfaces of wall, roofand floor etc. to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge. |
| 51 | Taking down unserviceable submain wiring and service cablealongwith batten /PVC conduits etc. and making good disturbed surfaces of walls/floors and match the existing surface all as directed at site. |
| 52 | Taking down unserviceable main switches, DBs with MCB SP/Isolators by unscrewing form board complete all as specified and directed by Engineer-in-Charge |
| 53 | M&L for point wiring using approved colour coding as per IS with using approved colour coding as per IS 1.5 Sqmm multistranded,1100 volt grade copper conductor cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulatedstranded copper conductor cable for continuous earthing in & incl PVC Casing Capeingwith accessories having ISI mark fixed on wall surfaces / ceilingincluding provision PCV Box on top for fixing switches sockets etc. all as specified for one light point/ fan /Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 54 | All as per Srl item No 4 here-in-before but controlled with one 3 pin socket outlet 5 Amp on same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 55 | All as per Srl item No 4 here-in-before but controlled with one 3 pin socket outlet 5 Amp onthe independent board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 56 | All as per Srl item No 4 here-in-before but controlled with one 3 pin socket outlet 15 Amp, independent board withcable 2.5 sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 57 | Supply and fixing ofswitch piano type 15 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 58 | Supply and fixing of socket outlet 3 pin 15 Amp 2-in-one230 Volt flush typecomplete all as specified and directed by Engineer -in-Charge. |
| 59 | Supply and fixing of socket outlet 3 pin 5 Amp 2-in-one230 Volt flush typecomplete all as specified and directed by Engineer -in-Charge. |
| 60 | Supply and fixing ofswitch piano type 5 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 61 | M&L Ceiling rose, 3 terminal with ISI markall as specified and directed by Engr-In-Charge. |
| 62 | Supply andfixing surface & wall mounted LED 20W tube light fitting 4 feet with high quality material and design, extruded aluminium housing enhances safety. High quality PC diffuser, reliable and robust housing structure, maximize the endurance over the life time slim integrated design, easy to install efficacy 125 limen/ watt all accessories as specified and directed by Engg-in-Charge. |
| 63 | Material and labour forlamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. |
| 64 | Supply andfixingLED lamp 9W energy saving upto 80%, BEE ratedwith all accessories all as specified and directed by Engg-in-Charge. |
| 65 | Supply & Fixing bulk head light with 10 W LED Lamp complete. |
| 66 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt,220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 67 | Supply and fixing ofsheet metal enclosure double door for DBs single pole and neutral for 8 way 240 volt complete all as specified and directed by Engineer-in-Charge. |
| 68 | Supply and fixing ofsheet metal enclosure double door for DBs single pole and neutral for 12 way 240 volt complete all as specified and directed by Engineer-in-Charge. Make Havells or equivalent |
| 69 | S&F MCBSPN 40 Amp,10 KA all as specified and directed by Engineer-in-Charge. |
| 70 | S&F MCB SP 6-32Amp, 10 KA curve \"B\". all as specified and directed by Engineer-in-Charge. |
| 71 | M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick burried directly in ground earth pit not less than 2.25 m below ground level connected to4 mm dia GI earth wire as earth lead by means of bolts,nuts,washers of Gl all as shown in electrical plate No 3 of SSR part I connected to earth test point including earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1 cover 40mm thick including 6 mm dia reinforcement and funnel watering pipe etc all as specified and directed.Note: On testing after completion if the desired resistance is not obtained the earthing shall be re-done at no extra cost. |
| 72 | S&F for submain wiring for circuit/submain wiring alongwith earth wire with the sizes 3x 10Sqmm of FR is PVC insulated copper conductor, single core cable in surface/ recessed including 20mm dia ms conduit complete all as specified and directed.Note:- 03 runs of 10sqmm cable shall be measured as 1 length. |
| 73 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm nominal cross section in service connections, complete all as specified and directed by Engineer-in-Charge. |
| 74 | Schedule of Credit |