| 1 | Excavation in foundation in ordinary soil (Loam,Clayor Sand) including lift upto 1.50 m and lead upto 30m and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer In-charge upto a distance of 30m from the foundation trenches. |
| 2 | Providing and laying in position cement concrete 1:4:8 (1cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) of specified grade excluding the cost of centering and shuttering . All work up to plinth level. |
| 3 | Mild steel or iron work in plain work such as reinforced concrete or reinforced brick work (When not included in and an over all rates) brought to required shape as necessary including bending for proper completion of the work and excluding the supply of steel and its wastage Bend, hooks and authorized over lapping shall be measured upto floor to level. |
| 4 | RCC work providing and laying in position specified grade of reinforced cement concrete in raft foundation .including the cost of c/shuttering .finishing and excluding reinforcement all work up to plinth lvl in 1;1.5;3 (1 cement ;1.5 coarse sand ; 3 graded stone aggregate 20 mm nominal size) COLUMN FOOTING |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 6 | 12mm thick plaster with cement and fine sand of 1.25 finene modules in 1:2 over brick work minumum thickness not to be less than 1cm. Including supply of all materials, labour, tools & plants etc. required for proper cornpletion of the work. |
| 7 | Providing wall putty on new surface with approved quality material of Berger/J.K./Birla or similar make 2 coats. |
| 8 | Providing and fixing 18 mm thick granite (gang saw cut) mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqm |
| 9 | Providing and laying factory made chamfered edge cement concrete paver blocks (80mm thick M-40 grade) in footpath, park & lawns driveway or light & traffic parking etc. of required strength thickness and size/shape, made by table vibratory method using PU mould, laid in required color and pattern over 50mm thick compacted bad of coarse sand, compacting and prober embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size & pattern, finishing & sweeping extra sand, all complete as per manufacture specifications & direction of Engineer-in-Charge. |
| 10 | DESTEMPERING (two coat) with oil bound destemper of approved brand and manufacture and of required shede on undecorated wall surface to give and even shede over and including a priming coat with cement primer of approved brand and manufecture such as berger j&n shalimar asian paint after thoroughly brushing the surface free from ortar dropping and other foreign matters and also sand papered smooth including supply of all materials .labour .tocls & plants etc .required for proper completion of the work |
| 11 | DOORS SAL WOOD CHOWKHAT |
| 12 | SAND FILLING in plinth including supply of necessary quantity of local sand from a distance not exceeding 8 kms from the site of work and including watering dressing etc. required for proper completion of work |
| 13 | 2.50 cm thick DPC with cement and approved course sand 1.1/2 and including water proofing materials as approved by the engineer incharge in the proprortion as specified but the manufacture including supply of all material .labour T&P for proper completion of the work including proper curing and shuttering as necessary. |
| 14 | Providing and laying at or near ground level factory made kerb stone of m25 grade cement concrete in position to the required line level and curvature .jointed with cement morter 1;3 (1 cement 3 course sand ) including making joints eith or without grocves (thickness of joint except at sharp curve shall not to more than 5 mm). including making drainage opening wherever required complete atc.as per direction of engineer incharge (length of finished kerb edging shall be masured for payment) .(precast c.c.kerb stone shall be aroved by engineer incharge DSR 16.69 |
| 15 | supply and fixing of flush doors commercial quality conforming of I.S. 2202 part-1 (1983) including ISI marked oxidized iron fitting with screws, bolt hinges ,handles,siliding bolt ,door stopper and tower bolt etc. |
| 16 | providing and fixing glass panes with putty and glazing clips in steel doors, windows clerestory windows all complete with 4.0 mm thick panes. |
| 17 | dismentling cement concrete or brick or granolithic floors including base concrete and including stacking of dismentled materials as directed by the enginner incharge within a distance of 60 metre (200 feet) |
| 18 | Antitermite treatment of along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructureto a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos / Lindane E.C. 20% with 1 % concentration As per IS6313:2001 |
| 19 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 20 | GRASS |
| 21 | Fast Growth Summer Glow Plant, For Garden |
| 22 | Jasmine plants |
| 23 | Plumeria Plant (Champa) |
| 24 | Fragrant Rosy Gardenia |
| 25 | Gulmohar – Delonix Regia |
| 26 | SS Grill |
| 27 | Supply and fixing galvanized mosquitos proof heavy quality iron wire gauge or expended metal heavy quality over windows and including supply of C.P. Teakwood batten 8cmX1cm (3\"X3/8\")/flat iron 25mmX4mm and including supply of necessary screws all materials, labour, T&P etc. required for proper completion of work. |
| 28 | Providing and laying vitrified floor files in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matcheng pigments etc., complete. size of tile 600x600mm |
| 29 | Electrical Fixture (Tube lights, Fans, Fancy lights) as per type design |
| 30 | PLUMBING, RAIN WATER DROP PIPE ETC as per type design |