| 1 | Taking down cement plaster on wall / ceilng surfaces including racking out joints, hacking for key scrubbing down with water etc to receive new plaster all as specified and as directed by the Engineer-in-Charge. Note :- The work shall be carried out in workshop building (curve roof) at 15 - 20 meter from ground level. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work. |
| 2 | Demolition of Brick work or stone masonary build in cement mortar complete all as specified and as directed by the Engineer-in-Charge. |
| 3 | M&L for Brickwork with Fly ash bricks (Old size), straight or curved on plan exc 6m mean radius, built in CM 1:6 all as specified and as directed by the Engineer-in-Charge. |
| 4 | M&L for rendering 10 mm thick on fair faces of brick work or concrete wall surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed by the Engineer-in-Charge. Note :- The work shall be carried out in building at 15 - 20 meter from ground level. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work. |
| 5 | M&L for rendering in CM 1:4, 15mm thick on external surfaces of concrete and brick masonry using water proofing compoundand finished the surfaces even and smooth without using extra cement all as specified and as directed by Engr-in-charge. (Note:- WPC measured and paid seperately.WPC will be mixed as per manufacturer\"s instructions). Note :- The work shall be carried out in building at 15 - 20 meter from ground level. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work. |
| 6 | Supply only integral water proofing compound. All as specified |
| 7 | M&L for rendering 5mm thick on fair faces of brick work or concrete ceiling surfaces in CM 1:3 finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. Note :- The work shall be carried out in building at 15 - 20 meter from ground level. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work. |
| 8 | M&L for preparation of new decorated surfaces and applying two coat of distemper over 3 mm thick wall care putty on walls all as specified and directed by Engineer in charge. Note :- The work shall be carried out in building at 15 - 20 meter from ground level. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work. |
| 9 | M&L for preparation of new plastered surfaces and applying three coat of white wash on ceilingall as specified and as directed by Engineer in charge. Note :- The work shall be carried out in building at 15 - 20 meter from ground level. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work. |
| 10 | M&L for preparation of new plastered surfaces of wall and applying two coats of exterior weather coat paintincluding one coat primer all as specified and directed by Engineer in charge. Note :- The work shall be carried out in building at 15 - 20 meter from ground level. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work. |
| 11 | M&L for preparation of old surfaces of walls and applying two coat of exterior weather coat paint complete all as specified and as directed by the Engineer-in-Charge. Note :- The work shall be carried out in building at 15 - 20 meter from ground level. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work. |
| 12 | M&L for preparing old wall surfaces and applying two coat of oil bound distemperall as specified and directed by Engr -in- Charge. Note :- The work shall be carried out in building at 15-20 meter from ground level.b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work. |
| 13 | M&L for preparing old wall surfaces and applying one coat of oil bound distemper all as specified and directed by Engr -in- Charge. Note :- The work shall be carried out in building at 15 - 20 meter from ground level. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work. |
| 14 | M&L for preparation of old decorated surfaces and applying one coat of white wash on walls all as specified and as directed by Engineer in charge. |
| 15 | M&L for preparation of old decorated surfaces and applying one coat of white wash on ceiling all as specified and directed by Engineer in charge.Note :- The work shall be carried out in building at 15 - 20 meter from ground level. b) The rate quoted shall included necessary ladder, safety equipments / accessories required for the work. |
| 16 | M&L for applying 3mm thick internal wall care putty complete all as specified and as directed by the Engineer-in-Charge. |
| 17 | M&L for preparation of old wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and asdirected by Engineer in charge. |
| 18 | M&L for preparation of old painted steel surfaces of any descriptionover 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed by Engineer in charge. |
| 19 | M&L for preparation of old surfaces onwalls and applying two coats ofcement base paint complete all as specified and asdirected. |
| 20 | M&L for preparation of old surfaces onwalls and applying one coats ofcement base paint complete all as specified and as directed. |
| 21 | M&L forwriting letters or figures (Block Roman or Indian) n.exc 30 cm height with using synthetic enamel paint (1st quality) all as specified and as directed by the Engineer-in-Charge. |
| 22 | M&L forwriting stops, commas, short lines, dashes, hyphens, brackets with synthetic enamel paint ( 1st quality) all as specified and directed by the Engineer-in-Charge. |
| 23 | Supply only Calcium hypo chlorite Granules packing size ne less than 45Kg , 65-95 concentration complete all as specifed and directed. |