| 1 | Demolition of Brickwork or stone/boulder masonry, laid in cement mortar for ashlars facings, dressed stonework, precast concrete articles and precast concrete block walling complete all as specified and directed by Eng-in-Charge. |
| 2 | M&L for precast cement concrete block masonry with solid block exc 10 cms in width made with PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) and set in cement mortar 1:6 complete all as specified and directed by Eng-in-Charge. |
| 3 | Rendering of 12 mm thick on fair faces of brick work or concrete surface in cement mortar 1:4 to be finished even and smooth using extra cementcomplete all as specified and directed by Eng-in-Charge. |
| 4 | Demolition Cement Concrete in ground floors and pavings n exc 15 cement mortar thickness (below or above ground level) complete all as specified and directed by Eng-in-Charge. |
| 5 | M&L Cement Concrete type B-1 (1:2:4) 20 mm graded crushed stone aggregate as copingin steps complete all as specified and directed by Eng-in-Charge. |
| 6 | Supplying and Fixing ‘APHONY GLOSS’ tiles made of Wood Fibre 1mm width cement composites (Non Magnesite bonded) covered with Acoustically Transparent Absorptive microfibres on the front side 20 mm thickwith an option of colours as per the choice of the Architect/ person in charge of size 600X1200 mm. Has excellent noise absorption of 0.9 NRC as per ISO: 354-1985 and ASTM 423-90 a, STC of 47 as per ASTM E-90/413 for 25mm, Density 400 Kg/ m3, meets stringent Fire Ratings ASTM D- 876 and BS:476 , weather resistance as per IS 3308, Thermal Conditivity result 45 w/m2/Kas per IS:3346-1980 with relative humidity of 90% RH at 60o Celcius (140o Farenhite) for 15 days No deterioration. Conforms to En 131682001 and are RoHS Complaint. To be installed with Aluminium H Profile on G.I studs 600x600mm centre to centre 2400mm X 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving ithigh strength, hot dipped galvanized steel with 120 GSM zinc coating specially designed for Acoustic vibration management and long life with a backing of50mm thick,1000 GSM absorb wool tested as per Fire Retardant ASTMD 635-1991/Insulation and IS 15061-2002 thermal conductivity test , W/mk , as per ASTM C 518 test result ( SC-6490) -0.03312for excellent results complete all as specified and directed by Eng-in-Charge. |
| 7 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets incl timber scantling framework complete all as specified and directed by Eng-in-Charge. |
| 8 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed by Eng-in-Charge. |
| 9 | Supply and fixing of Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Eng-in-Charge. |
| 10 | Supply and fixing ofPre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Eng-in-Charge. |
| 11 | Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socketor power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface etc. complete all as specified and directed by Eng-in-Charge. |
| 12 | Material and labourfor point wiring with 1.5 sqmm cable FRLSPVC insulated, unsheathed copper multistranded conductor, 1100 V grade of size 1.5sqmm including necessary termination board 1.5 Sqmm PVC insulated unsheathed FRLScopper conductor as earthingand connected to common earthing with PVCheavy duty casing caping/PVC conduit ISI marked as rquired at site along with all accessories and making good the disturbed surfaces of wall/ ceiling etcfor the following : - |
| 13 | One light point/ one fan point controlled by one 6 Amp switchcomplete all as specified and directed by Eng-in-Charge. |
| 14 | One 3 pin socket outlet, 6 Amp on independent boardcomplete all as specified and directed by Eng-in-Charge. |
| 15 | Supply and fixing in repair switch piano flush type single pole one way6 Ampscomplete all as specified and directed by Eng-in-Charge. |
| 16 | Supply and fixing in repair switch socket cobination 2 in 1, 6 amp flush typecomplete all as specified and directed by Eng-in-Charge. |
| 17 | Supply and fixingin repairCeiling rose3 plates flush type 6 Amps, 250 volts ACISI markedcomplete all as specified and directed by Eng-in-Charge. |
| 18 | All as per item No 12.00 above butfor point wiring for power point with 2.5 Sqmm FRLS PVC insulated unsheathed copper cable 1100 Volt grade drawn through and including PVC casing caping heavy dutyISI marked /heavy duty conduitISI marked as required at site alongwith accessories with 2.5 Sq mmFRLS PVC insulated unsheathed copper conductor cable as earthing and connected to common earthcomplete all as specified and directed by Eng-in-Charge. |
| 19 | Supply and fixing in repair switch socket combination switch socket outlet 3 pin, 16 amp flush typecomplete all as specified and directed by Eng-in-Charge. |
| 20 | Supply and fxing in repair wall mounted LED light fitting 1x20 watts AC decorative box type with driver holder including LED tube light , energy ef?cient type 4 feet long including neccessary conection prewired and making connection with 3 core copper flexible cable of appropriate size from ceilling rose complete all as specified and directed by Eng-in-Charge. |
| 21 | Supply and fixing in repair sheet metal enclosure SPN DB 02 way,single phase 240 volts double door with 200 amp rated bus bar complete all as specified and directed by Eng-in-Charge. |
| 22 | Supply and fixing in repair sheet metal enclosure SPN DB 08 way,single phase 240 volts double door with 200 amp rated bus barcomplete all as specified and directed by Eng-in-Charge. |
| 23 | Supply and fixing in repairfor Circuit breaker single pole, 6 to 32 Amp 240 volt C curve 10 KA, IP 20complete all as specified and directed incl taking down old one complete all as specified and directed by Eng-in-Charge. |
| 24 | M&L in repairfor Circuit breaker single pole & neutral240 volt C curve 10 KA 32/40 Amps capacity IP 20complete all as specified and directed including taking down old one complete all as specified and directed by Eng-in-Charge. |
| 25 | Supply and fixing of LED security light fitting 33/45 watts 230 volts AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Eng-in-Charge. |
| 26 | Supply and fixing in repair of exhaust fan , steel body AC single phase 230 volt of size 250/300 mm sweep mettalic body with blades and frame and louvers complete all as specified and directed by Eng-in-Charge. |
| 27 | Supply and fixing in repairtwo single core 6 sq mm for sub Main wiring with copper conductor multistranded PVC insulated and unsheathed 1100 Volts grade in and including PVC casing capping with fixing accessories including one run of 6 Sq mm copper conductor complete all as specified and directed by Eng-in-Charge. (Note - Two runs of 06 Sq mm cable, one run of 6 Sq mm earth cable and one run of PVC casing Capping shall be measured as one running meter) |
| 28 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 2 core complete all as specified and directed by Eng-in-Charge |
| 29 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc non exc 10 Sqm on plan and nexc 1.5 m in depthe and getting out for laying of cable / pole etc in hard/dense soil complete all as specified and directed by Eng-in-Charge. |
| 30 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed by Eng-in-Charge. |
| 31 | Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed by Eng-in-Charge. |
| 32 | M&L for dry sand cushioning to underground electric cable 8mm thick before laying of cable and 15cm thick after laying of cable laid in trenchescomplete all as specified and directed by Eng-in-Charge. |
| 33 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 flat of size 250mm x150mm x 40mm placed perpendicular of the cable complete all as specified and directed by Eng-in-Charge. |
| 34 | Material and labour earthing complete with galvanized steel earth plate 60 cm x 60cm x 6.0mm thick buried directly in ground vertically to a depth not less than2.25 mtr below ground level with top edge of the earth plate at a depth not less less than 1.5 mtr filled aroundwith 15 cm thick alternate layers of charcoal dust and salt and connected to earth leadwire 4mm dia (8 SWG) by means of bolt, nut and check nutsand washers of galvanized iron or steel and thimble and other ends of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm bore and watering pipe 20mm dia light grade with funnel and wiremesh, pcc 1:3:6 type C-1 in chambers RCC 1:2:4 type B-1 in pit cover reinforced with 8 mm dia deformed bars 15cm center to center both ways complete all as shown in electric plate No 3 of MES SSR Part Icomplete all as specified and directed by Eng-in-Charge. complete all as shown in electric plate No 3 of MES SSR Part I |
| 35 | Deduct Credit for Demolished/Dismantled material Rs (-) 53,014.00 (Minus) as listed in Schedule \"A\" Sec-II (Credit Schedule)Note :Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the \"Contract Sum\". |