Bids Are Invited For Cssd Consumables -1 SAL THERMOSEAL TAPE 24mm*50mtrs CREPE PAPER WITH NATURAL RUBBER ADHESIVE. FOR MEDICAL USE ONLY. SHOULD SUSTAIN TEMPERATURE OF 134˚C IN A AUTOCLAVE. SHOULD NOT LEAVE THE ADHESIVE BEHIND AFTER STERILIZATION 2 SAL AUTOCLAVE TAPES 18mm*50mtrs IT SHOULD BE MADE OF SATURATED CREPE PAPER WITH COLOUR CHANGING PROPERTIES AT A TEMPERATURE 1210 C/ 1340 C. (5) ADHESIVE SHOULD BE NON TOXIC. (6) THE INK SHOULD NOT CONTAIN LEAD AND HEAVY METAL 3 CREPE PAPER GREEN 60cm*60cm SHOULD COMPLY WITH EN 868-1&2 STANDARD. COMPATIBILITY WITH STEAM AND EO STERILIZATION PROCESS. RECYCLE, ECO FRIENDLY AND SHOULD BE ACCEPTED BY ANY WASTE MANAGEMENT. IT SHOULD BE OF 60GSM AND SHOULD BE MOISTURE ABSORPTION CAPACITY. COLOR – GREEN. COMPLAINS WITH THE ISO 11607 & 868 STANDARDS. 4 CREPE PAPER GREEN 90cm*90cm SHOULD COMPLY WITH EN 868-1&2 STANDARD. COMPATIBILITY WITH STEAM AND EO STERILIZATION PROCESS. RECYCLE, ECO FRIENDLY AND SHOULD BE ACCEPTED BY ANY WASTE MANAGEMENT. IT SHOULD BE OF 60GSM AND SHOULD BE MOISTURE ABSORPTION CAPACITY. COLOR – GREEN. COMPLAINS WITH THE ISO 11607 & 868 STANDARDS. 5 CREPE PAPER GREEN 120cm*120cm SHOULD COMPLY WITH EN 868-1&2 STANDARD. COMPATIBILITY WITH STEAM AND EO, FORM, IRRAD STERILIZATION PROCESS. RECYCLE, ECO FRIENDLY AND SHOULD BE ACCEPTED BY ANY WASTE MANAGEMENT. IT SHOULD BE OF 60GSM AND SHOULD BE MOISTURE ABSORPTION CAPACITY. COLOR – GREEN. COMPLAINS WITH THE ISO 11607 & 868 STANDARDS. 6 35 GSM NON WOVEN 60cm*60cm COMPLY WITH EN 868 – 2. COMPLY WITH THE ESSENTIAL REQUIREMENT 93/42/EEC DIRECTIVE AND MUST BE CE MARKED. BACTERIAL BARRIER. REPELLENT FLUID, MUST BE STRONG, LOWERING THE RISK OF PUNCTURING OR TEARING DURING WRAPPING, TRANSPORT. CAN BE STERILIZED IN STEAM, EO, FORMALDEHYDE AND VH2O2. COLOR- GREEN. IT SHOULD BE OF 35GSM DOES NOT CONTAIN NATURAL FIBERS (CELLULOSE) OR SYNTHETIC BINDER. SHOULD BE 100% POLYPROPYLENE AND TREATED TO RESIST STATIC CHANGE BUILD UP. 7 35 GSM NON WOVEN 90cm*90cm COMPLY WITH EN 868 – 2. COMPLY WITH THE ESSENTIAL REQUIREMENT 93/42/EEC DIRECTIVE AND MUST BE CE MARKED. BACTERIAL BARRIER. REPELLENT FLUID, MUST BE STRONG, LOWERING THE RISK OF PUNCTURING OR TEARING DURING WRAPPING, TRANSPORT. CAN BE STERILIZED IN STEAM, EO, FORMALDEHYDE AND VH2O2. COLOR- GREEN. IT SHOULD BE OF 35GSM DOES NOT CONTAIN NATURAL FIBERS (CELLULOSE) OR SYNTHETIC BINDER. SHOULD BE 100% POLYPROPYLENE AND TREATED TO RESIST STATIC CHANGE BUILD UP. 8 35 GSM NON WOVEN 120CM*120CM COMPLY WITH EN 868 – 2. COMPLY WITH THE ESSENTIAL REQUIREMENT 93/42/EEC DIRECTIVE AND MUST BE CE MARKED. BACTERIAL BARRIER. REPELLENT FLUID, MUST BE STRONG, LOWERING THE RISK OF PUNCTURING OR TEARING DURING WRAPPING, TRANSPORT. CAN BE STERILIZED IN STEAM, EO, FORMALDEHYDE AND VH2O2. COLOR- GREEN. IT SHOULD BE OF 35GSM DOES NOT CONTAIN NATURAL FIBERS (CELLULOSE) OR SYNTHETIC BINDER. SHOULD BE 100% POLYPROPYLENE AND TREATED TO RESIST STATIC CHANGE BUILD UP. 9 SAL STERILIZATION REELS GREEN 10cm*200mtrs EO AND STEAM INDICATOR SHOULD BE LOCATED IN THE SEAL AREA. POVIDINE IODINE SHOULD NOT PASS THROUGH THE PAPER SIDE. SHOULD COMPLY TO STANDARDS EN ISO 11140-1 , EN ISO 868-3,5 AND 6.PAPER AND PLASTIC AS PER EN ISO STANDARDS. LEAKAGE TEST METHOD→ ASTMF-1929-98. BIOBURDEN EN ISO 11607. LOT NO, DATE OF MANUFACTURING AND DATE OF EXPIRY MUST BE PRINT INTERNALLY. A MEDICAL GRADE 60GSM PAPER CONFIRMING EN 868-3. SIZE OF THE REEL SHOULD BE PRINT ON PLASTIC SIDE. 10 SAL STERILIZATION REELS GREEN 20cm*200mtrs EO AND STEAM INDICATOR SHOULD BE LOCATED IN THE SEAL AREA. POVIDINE IODINE SHOULD NOT PASS THROUGH THE PAPER SIDE. SHOULD COMPLY TO STANDARDS EN ISO 11140-1 , EN ISO 868-3,5 AND 6.PAPER AND PLASTIC AS PER EN ISO STANDARDS. LEAKAGE TEST METHOD→ ASTMF-1929-98. BIOBURDEN EN ISO 11607. LOT NO, DATE OF MANUFACTURING AND DATE OF EXPIRY MUST BE PRINT INTERNALLY. A MEDICAL GRADE 60GSM PAPER CONFIRMING EN 868-3. SIZE OF THE REEL SHOULD BE PRINT ON PLASTIC SIDE. 11 SAL STERILIZATION REELS GREEN 40cm*200mtrs EO AND STEAM INDICATOR SHOULD BE LOCATED IN THE SEAL AREA.POVIDINE IODINE SHOULD NOT PASS THROUGH THE PAPER SIDE.SHOULD COMPLY TO STANDARDS EN ISO 11140-1 , EN ISO 868-3,5 AND 6.PAPER AND PLASTIC AS PER EN ISO STANDARDS. LEAKAGE TEST METHOD→ ASTMF-1929-98. BIOBURDEN EN ISO 11607. 12 INSTANT BIOLOGICAL INDICATOR STEAM SELF CONTAINED BIOLOGICAL AMPOULE SHOULD CONTAIN BACILLUS STEAROTHERMOPHILUS WITH THE POPULATION OF 10^5 CFU AND TYPE 5 CHEMICAL INDICATOR INSIDE THE AMPOULE FOR INSTANT RELEASE SHOULD COMPLY TO STANDARD EN ISO- 11138-1+3 AND TYPE 5 TO EN ISO- 11140-1 13 3 LINE LABEL STEAM (C-S-L-1-DA-R-ECO) THREE LINE LABEL WITH STEAM INDICATOR DOCUMENTATION TO BE USED IN LABELING GUN.SHOULD BE LEAD FREE.THREE LINE LABEL DOUBLE ADHESIVE WITH ALPHA NUMERIC AND NUMERIC LETTERS IMPRINTED WITH CLASS-1 AS PER EN ISO 11140 -1.THE INDICATORS SHOULD NOT CHANGE COLOR IN DRY HEAT AT 140 °C FOR 30 MINUTES AS PER EN-11140 14 BOWIE DICK SIMULTATION TEST(C-S-BDS-SV1) TYPE 2 CHEMICAL INDICATOR WITH ADHESIVE SHOULD PASS THE DRY HEAT TEST AS PER EN-ISO-11140, COLOUR SHOULD NOT CHANGE TO END RESULT IN DRY HEAT, AIR REMOVAL TEST ACCORDING TO EN 285 (7KG) OR AAMI/ANSI/ST79 (4KG TEST) AND VALIDATED ACCORDING TO THE TEST METHOD OF ISO 11140-1+5 FOR STEAM STERILISATION 15 BATCH MONITORING STRIPS STEAM TYPE 2 CHEMICAL INDICATOR TO BE USED IN METAL PCD ACCORDING TO EN ISO - 11140-1 AND LAB REPORT EN ISO 17025 INDICATORS SHOULD HAVE ADHESIVE FOR DOCUMENTATION AND SHOULD NOT CHANGE COLOUR IN DRY HEAT AS PER EN ISO -11140 16 SAL TYVEK ROLL 10cm*70cm REAL WITH H2O2 INDICATOR TO MONITOR PLASMA STERILIZATION. COMPLY WITH EN 868-5 AND ISO 11607. FREE FROM LEAD AND HEAVY METALS. LOT NO, DATE OF MANUFACTURING AND DATE OF EXPIRY MUST BE PRINT INTERNALLY. SIZE OF THE REEL SHOULD BE PRINT ON PLASTIC SIDE 17 SAL TYVEK ROLL 40cm*70cm STERILIZATION. COMPLY WITH EN 868-5 AND ISO 11607. FREE FROM LEAD AND HEAVY METALS. LOT NO, DATE OF MANUFACTURING AND DATE OF EXPIRY MUST BE PRINT INTERNALLY. SIZE OF THE REEL SHOULD BE PRINT ON PLASTIC SIDE 18 SAL TYVEK ROLL 20cm*70cm REAL WITH H2O2 INDICATOR TO MONITOR PLASMA STERILIZATION. COMPLY WITH EN 868-5 AND ISO 11607. FREE FROM LEAD AND HEAVY METALS. LOT NO, DATE OF MANUFACTURING AND DATE OF EXPIRY MUST BE PRINT INTERNALLY. SIZE OF THE REEL SHOULD BE PRINT ON PLASTIC SIDE 19 LIQUIZIME 1 GALLON LOW FOAM MULTI ENZYME SOLUTION .MILD ALKALINE.PH = 9- 10.5,SHOULD WORK IN HARD, SOFT AND COLD WATER. BIODEGRADABLE, ECO FRIENDLY .SHUD FIT IN WD AND WORK IN ULTRASONIC.NO ECOTOXICITY CE CERTIFIED 20 PREMIXSLIP AEROSOL 410 ml NON STICKY, NON TOXIC SILICON FREE AND WATER SOLUBLE MINERAL OIL LUBRICANT. PREVENT RUST, STAINING AND SPOTTING. STEAM PENETRABLE, STEAM AND EO STERILIZABLE. NO ECOTOXICITY, BIO DEGRADABLE COMPOSITE OF BUTANE/ PROPANE 21 ENDOZYME AW PLUS W/A P.A. 1GALLON NEUTRAL PH, NON - ABRASIVE, FREE RINSING 100% BIODEGRADABLE. BEGINS DISSOLVING AND DIGESTING FATS, BLOOD, PROTEINS AND OTHER CONTAMINANTS ON CONTACT 22 SURGISTAIN 1 GALLON (1) IT SHOULD BE MILD ACID SOLUTION TO REMOVE STAINS, SPOTS AND RUST FROM STAINLESS STEEL INSTRUMENTS. (2) CAN BE USED FOR WD AND ULTRA SONIC CLEANER. (3) IT SHOULD BE NON-CORROSIVE WITH CE/ISO AS APPLICABLE. (4) FREE RINSING, NON-AEROSOL AND ENVIRONMENTALLY SAFE. (5) WATER SOLUABLE AND NOT FLAMMABLE. (6) CHEMICAL CONTAIN PHOSPHORIC ACID OF PH>2 23 F.A.C.T.S 650ML 1) IT SHOULD REMOVE ALL RUST, STAINS AND CORROSION FROM WALLS OF AUTOCLAVES AND FROM STAINLESS STEEL CARTS AND TRAYS. (2) IT SHOULD BE NON-CORROSIVE HAVING CE/ISO AS APPLICABLE. (3) FREE RINSING AND LEAVES NO RESIDUE. (4) NO FLAMMABILITY AND TOXICITY PROPERTIES. (5) IT SHOULD BE MILD ACIDIC IN NATURE. (6) IT CONTAIN PHOSPHORIC ACID OF PH >1 24 SAL PLASMA TAPES 18MM*50MTRS MADE UP OF SPECIAL PLASTIC WITH NON TOXIC ADHESIVE. THE INDICATOR TAPE CHANGES COLOURS FROM BLUE TO PINK WHEN EXPOSE TO VH2 O2 INK DOES NOT CONTAIN LEAD AND HEAVY METALS. FDA/ISO AS APPLICABLE 25 PACKAGE MONITORING INDICATORS(B-S-MBP-I-10-5) STEAM TYPE 5 INDICATOR FOR STEAM PROCESS. SHOULD EXPLICITY FULFILL THE CRITERIA OF EN ISO - 11140 - 1. SHOULD NOT CHANGE COLOR IN DRY HEAT TEST @ 140 DEGREES FOR 30 MINUTES 26 3 LINE LABEL HYDROGEN PEROXIDE (C-V-L-1-DA-R) THREE LINE LABEL WITH PLASMA INDICATOR DOCUMENTATION TO BE USED IN LABELING GUN. SHOULD BE LEAD FREE. THREE LINE LABEL DOUBLE ADHESIVE WITH ALPHA NUMERIC AND NUMERIC LETTERS IMPRINTED WITH CLASS-1 AS PER EN ISO 11140 -1. 27 BATCH MONITORING STRIPS PLASMA(C-V-PM-2) CLASS-2 CHEMICAL INDICATOR TO MONITOR PLASMA STERILIZATION COMPATIBLE TO THE STAINLESS STEEL HELIX PCD AS PER EN 1422. SHOULD BE LEAD FREE. SHOULD BE WITH ADHESIVE FOR EASY DOCUMENTATION 28 PACKAGE MONITORING INDICATORS PLASMA(C-V-P-SV6) INDICATOR ACCORDING TO EN ISO 11140 – 1 TYPE 4 INDICATOR TO CHECK HYDROGEN PEROXIDE PENETRATION. SHOULD BE LEAD FREE WITH ADHESIVE FOR EASY DOCUMENTATION SHOULD MONITOR 2 MIN DEFINE TIME AND CONCENTRATION. 29 BIOLOGICAL INDICATOR PLASMA(B-V-G-MBP-10-6) SELF CONTAINED BIOLOGICAL INDICATOR FOR HYDROGEN PEROXIDE STERILISATION SHOULD HAVE GEOB.STEAROTHERMOPHILUS WITH POPULATION 10^6 CFU ON GLASS FIBRE CARRIER 30 CLEANING MONITORING INDICATORS(W-CPI-G) CHEMICAL INDICATOR TO MONITOR CLEANING PROCESS FOR WASHER DISINFECTOR, ULTRASONIC MACHINE AND MANUAL.WASHING.NON TOXIC, SHOULD BE DISSOLVED WITH MOST OF THE CLEANING AGENT.SELF ADHESIVE FOR EASY DOCUMENTATION.INDICATOR SHOULD BE VALIDATED AGAINST TEST SOIL ACCORDING TO 15883-5INDICATOR SHOULD BE COMPACTABLE TO THE CLEANING PROCEDURE FOR HOLLOW INSTRUMENTS AND HOLLOW PCD.TYPE SOIL FOR REMOVAL SHOULD BE BLUE/YELLOW 31 TRAY LINERS- 535mm*330mm HIGH ABSORBENCY AND RAPID DISPERSION. FIT SNUGLY ON BOTTOM OF THE CONTAINER OR TRAY. LATEX FREE, 72GSM MATERIAL SHOULD BE MADE FROM PURE CELLULOSE EFG WOOD PULP, MANUFACTURED WITH LOW CHLORIDE AND SULFATE CONTENT AND FREE OPTICAL DYES. PROVIDE PROTECTION OF DELICATE AND SHARP INSTRUMENTS. STEAM AND EO STERILIZABLE. SHOULD TOLERATE UP TO 1370C IN STEAM STERILIZATION. COMPLY WITH ESSENTIAL REQUIREMENTS OF THE MEDICAL DEVICES EC93/42- 2007/47/EC-CLASS-1 32 SAL INSTRUMENTS BRUSHES HARD AND SOFT MULTI BRISLE NYLON BRUSHES. SHOULD BE AUTOCLAVEABLE. SINGLE AND DOUBLE SIDES. 33 Sterrad Nx Cassette HSN code 380894 Hydrogen Peroxide Cassettes with leak proof indicator for STERRAD NX Machine, can be store at room tempreture. Total Quantity : 55708