| 1 | Providing and placing in position 100 mm thick factory made machine batched and machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100 mm c/c on both ways, neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick, 100 mm wide MS sheet duly painted over priming coat, reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc including cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. |
| 2 | Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved qualityEHD-35 of circular shape 560 mm internal dia. |
| 3 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :i) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 6 | Providing and fixing in position precast R.C.C. manhole cover of required shape and approved quality HD-20 of circular shape 560 mm interna dia. |
| 7 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 8 | Brick work with non-modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in:Cement mortar 1:6 (1 cement: 6 Coarse sand) |
| 9 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1cement:6 fine sand) |
| 10 | Cement plaster in fine sand of 12 mm cement plaster of mix 1:6(1 cement:6 fine sand) |
| 11 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000×450×50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to125 mm c/c, including providing edge binding with M.S. flats of size 50 mm × 1.6 mm complete, all as per direction of Engineer-in-charge. |
| 12 | Disposal of building rubbish /malba /similar unserviceable, dismantled or wastw materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge,beyond 50 m initial lead, for all leads including all lifts involved . |
| 13 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar |
| 14 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm). |
| 15 | Renewal of old putty of glass panes (length) . |
| 16 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 17 | Finishing walls with water proofing cement paint of required shade :Old work (one or more coats @ 2.20 kg/10 sqm) complete. |
| 18 | Finishing walls with water proofing cement paint of required shade : New Work (Two or more Coat applied @3.84kg/10 sqm) |
| 19 | White washing with lime to give an even shade :Old work (one or more coats) . |
| 20 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work. |
| 21 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 22 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift upto 1.5 m. All kinds of soil. |
| 23 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 24 | Providing and fixing PTMT urinal cock of approved quality and colour 15 mm nominal bore, 80 mm long.42 mm high and 30 mm wide with BSP female threads weighing not less than 48 gms. |
| 25 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete semi rigid pipe 32 mm dia. |
| 26 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti -microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass headed polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.External work: PN-16 pipe,20mm OD (SDR-7.4) |
| 27 | Providing and fixing on wall face un-plasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter |