| 1 | Wood work in posts, post plates, rafters, battens, truss members, purlins etc.fitted and fixed complete (excluding the cost of bolts, paints, but including the costof nails, screws etc.) (The quantum should be corrected upto three decimals) Sal Local |
| 2 | Ceiling with 12mm thick wooden planks fitted and fixed complete (excluding thesupporting framework) as per direction of the Engineer-in-charge.In Ground Floor b) Sishu / Champ / Badam / Gamar / Bhola / Mogra / Hallak |
| 3 | Rough dressed timber planks fitted and fixed with nut bolts excluding frameworkcomplete :In ground floor(i) 25mm thick planks Sal Local |
| 4 | Supplying, Fitting & Fixing Factory made P.V.C. door frame of size 50 mmx47mm with a wall thickness of 5 mm, made out of extruded 5 mm, PVC sheet mitercut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19mmx 19 mm M.S. Square tube of 19 gauge, weather seal to be provided throughout the frame. The door frame shall be fixed with the wall using 65/100 mm longM.S. Screws through the frame by using P.V.C fasteners. A minimum of 4 Nos ofscrews to be provided for each vertical member and minimum 2 Nos forhorizontal member etc. complete as per Manufacturer?s specification anddirection of Engineer-in-Charge. |
| 5 | Supplying, Fitting & Fixing 30 mm thick Factory made moulded Door shutter,wood free consisting of frame made out of 25 mm, M.S. tube, M.S. frame shallhave a coat of steel primer. The inner panel shall consist of 25 mm thick HighDensity EPS. With 2 mm thick termite proof, water proof and fire resistantmoulded PVC sheet with raised panel design in different plain and /or prelamcolours after routing the moulded design on one side & 2 mm plain and/ orprelam PVC sheet on other side of the EPS. The edge of Panel to be sealed withlipping of 10 mm wide P.V.C. sheet batten made by sticking 2 Nos P.V.C. rigidfoam sheet of 5 mm thickness using P.V.C. solvent cement and style sides 25 mm[5x5 mm] th. and 30 mm with PVC sheet fitted along M.S. tube for lock provisionand for lock height 5 mm thick PVC sheet [150 mmx100 mm] fixed with upper andlower face of inner side of EPS Panel etc. complete excluding hardwares asnecessary as per direction of Engineer-in-Charge and Manufacturer?sSpecification.In ground floor (b) Moulded door using 2 mm Prelam moulded PVC sheet on both side. |
| 6 | Wood work in door and window frame fitted and fixed in position completeincluding a protective coat of painting at the contact surface of the frameexluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum shouldbe correted upto three decimals). Sal Local |
| 7 | Glazed shutters of doors, windows, fan light, clerestory windows etc. as perdesign (with ordinary glass of 7.4kg./sq.m. 3mm. Thick) fitted with putty bed andteak wood bead and nails including fitting and fixing shutter in position butexcluding the cost of hinges and other fittings. cost of glass, putty, wooded beadsetc.will be paid separately.In ground floor. (ii) 35mm thick shutters. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. |
| 8 | Panel shutters of door and window, as per design (each panel consisting of singleplank without joint), including fitting and fixing the same in position butexcluding the cost of hinge and other fittings.In ground floor.(In case of non-supply of single plank, penal rate of reduction of 20% will bemade) (ii) 40mm thick shutters with 19mm thick panel of size 30 to 45 cm. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. |
| 9 | Z-batten shutters of door and window as per design havings tongued and groovehalf lap jointed as per direction of the Engineer-in-Charge including fitting andfixing shutter in position, but excluding the cost of hinges and other fittings inground floor. (A) Shutter with 25mm thick planks, 19mm thick battens. (iii) Sishu, Gamar, Champ, Badam, Bhola, Morga, Hallak |
| 10 | Anodised aluminium butt hinges of approved quality manufactured from extrudedsection conforming to I.S. specification (I.S. 205/66) and fitted and fixed withcadmium plated screws: (iv) 75 x 63 x 3.2mm |
| 11 | (vii) 100 x 75 x 4.0mm. |
| 12 | Anodised aluminium barrel / tower / socket bolt (full covered) of approvedmanufactured from extruded section conforming to I.S. 204/74 fitted and fixedwith cadmium plated screws: (v) 150mm long x 12mm dia. Bolt |
| 13 | (vi) 200mm long x 10mm dia. bolt. |
| 14 | Anodised aliminium D-type handle of approved quality manufactured fromextruded section conforming to I.S. specification (I.S. 230/72) fitted and fixedcomplete b) With round base: iii) 100 mm grip x 12 mm dia rod |
| 15 | b) With round base: v) 150 mm grip x 12 mm dia rod. |
| 16 | Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous& Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr\"s hardness > 5.0, Staining resistance:Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). |
| 17 | Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor. b) Area of each Granite slab 0.6 to 1.0 Square meter |
| 18 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with16mm dia rod with centre bolt and round fitting. c) 300mm long. |
| 19 | Priming one coat on timber or plastered surface with synthetic oilbound primer of approved quality including smoothening surfaces by sandpapering etc. |
| 20 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface :With super gloss (hi-gloss) - (ii) Two coats (white in shade). |
| 21 | With other than hi-gloss of approved quality. (iv) Two coats (with any shade except white) |
| 22 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receivedecorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly,complete as per manufacturer\"s specification and as per direction of the EIC.In Ground Floor:(a) One Coat |
| 23 | Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturer\"s specification and as per direction ofEngineer-in-Charge to be applied over acrylic primer as required. Therate includes cost of material, labour, scaffolding and all incidentalcharges but excluding the cost of primer.In Ground floor (Two Coat). b) Premium 100% Acrylic Emulsion |
| 24 | Copal varnish of approved quality including preparing surface : (ii) On old varnish surface including removing old varnish and exposingoriginal surface : (a) Two coat |
| 25 | Earth work in filling in foundation trenches or plinthwith good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (iv) With carried earth arranged by the contractor within a radius exceeding 5 km. but not exceeding 10 km. including cost of carried earth. |
| 26 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 27 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mmnominal size) excluding shuttering and reinforcement,if any, in ground flooras per relevant IS codes. b) River bazree |
| 28 | Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreouschina ware of approved make complete in position with necessary bolts,nuts etc. (a) With \"P\" trap (with vent) |
| 29 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete.(a) E.W.C. ii) Plastic (hallow type) white |
| 30 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 31 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make withnecessary fixing materials and clamps complete. i) Polythene Flush Pipe |
| 32 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm |
| 33 | Supplying, fitting and fixing towel rail with two brackets.(a) C.P. over brass(i) 25 mm dia. and 600 mm long |
| 34 | Supplying, fitting and fixing soap holder. (a) PTMT (Prayag or equivalent) |