| Sl. No. | Item Description |
| 1 | Surface Excavation not exc. 30 Cm deep and ave. 15 Cm deep and getting out in Soft/Loose Soil, complete all as specified and as directed. |
| 2 | Excavation in trenches not exc. 1.5 Metre wide and not exc. 1.50 Metre in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exc. 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 3 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm as in Soft/Loose Soil, complete all as specified and as directed. |
| 4 | Removing excavated Material (Soil) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed. |
| 5 | M&L Hardcore of gauge not exc. 63 mm, broken stone aggregate deposited, spread and levelled in layers n exc. 15 Cm thick, watered and rammed to a True Surface, complete all as specified and as directed. |
| 6 | M&L Earth filling under floor or in foundations including watering and consolidation, spreading and levelling in layers n exc. 25cm thick complete all as specified and directed.Note- Additional earth if required shall be obtained from MOD land and rate of which shall deemed to be included in the quoted rate |
| 7 | M&L Plain Cement Concrete type D2 (1:4:8) using 40 mm graded aggregate as in Foundation, Filling and Mass Concrete, complete all as specified and as directed. |
| 8 | M&L Reinforced Cement Concrete (Design Mix) M-25 in Foundations including Rafts, Footings, Foundation Beams; Plinth Beams; bases for Columns, etc.; Basement Slabs, Under-reamed Piles and Mass Concrete, complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 9 | M&L Reinforced Cement Concrete (Design Mix) M-25 in Columns, Pillars, Piers, Posts and Struts, etc. complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 10 | M&L Reinforced Cement Concrete (Design Mix) M-25 (Using 20mm graded stone aggreagate) as in slab, shelves supported on walls beam & coloumns in floor roof including balconies, canopies, deck slabs & shelves complete all as specified and directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 11 | M&L Reinforced Cement Concrete (Design Mix) M-25 in Chajja, etc., complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 12 | M&L Reinforced Cement Concrete (Design Mix) M-25 in Roof Beams, Cantilevers, Bres-summers, Lintels over 1.50 Metre Span, complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 13 | M&L Formwork to Sides of Concrete Founda-tions, Footings, bases of Columns, Raft and Raft Beams, Sides and Soffits (if any) of foundation and plinth beams and similar work; Square, rectangular or polygonal, vertical or to batter, flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 14 | M&L Formwork toSoffits of suspend slab such as Roof slab, Floor slab, landings and similar works horizontal or sloping etc., not exceding 200mm thick ,flat rough finished surfaces of concrete, complete all as specified and as directed. |
| 15 | M&L Formwork to sides of Pillars, Posts, Struts, Piers, Columns and stanchions, flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 16 | M&L Formwork to Sides and Soffits of Floor or Roof Beams, Beam Haunchings, Girders, Bres-Summers, Lintels, Cantilevers, Shelves including supports, overhangs, etc. also splays between floors and beams, etc., flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 17 | M&L Formwork to edges of concrete flats , treads, breaks in floors, window cills, concrete ralings, openings in concrete walls, floors and roofs .exc 20 cm wide and sides of RCC/ PCC bands in walls , horizontal or sloping and similar workrough finishedconcrete surface complete all as specified and as directed. |
| 18 | M&L Formwork to Chajjas and Similar Items including edges, flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 19 | M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and bindingwith and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed. |
| 20 | M&L TMT Bars 8 mm dia , cut to length, bent to shape required including crank-ing, bending and bindingwith and including Mild Steel Wire (annealed) not less than 0.90 mm, as in stirrups spacers and binders complete all as specified and as directed. |
| 21 | M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed. |
| 22 | M&L Brick Work with Sub-Class ‘B’ Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed. |
| 23 | Demolition of lathing plaster including battens andplaster or chicken wire lathing etc complete all as specified and directed. |
| 24 | Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed. |
| 25 | M&L Rendering 15mm thick on brick wall or concrete surface consisting two layers, under layer of 10mm thick in CM (1:4) & top layer of 5mm thick in cement mortar 1:4 mixed with water proofing compound, finished even and smooth without using extra cement complete all as specified and directed. Note:- Water proofing compound shall be measured and paid saperately. |
| 26 | M&L Rendering15mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and fair without using Extra Cement complete all as specified and as directed. |
| 27 | M&L Rendering 5.0mm thick in Cement Mortar 1:3 on Concrete Surfaces of Ceiling, etc. finishing Plastered Surfaces Even and Smooth, without using Extra Cement. complete all as specified and as directed. |
| 28 | \"Supply only\" liquid water proofing compound (ISI marked) complete all as specified and directed. |
| 29 | M&L Cement Concrete type C2 (1:3:6) using 40mm graded aggregate 75mm thick in Sub-bases, finishing concrete surfaces fair and even, complete all as specified and as directed. |
| 30 | M&L Cement Concretetype C2(1:3:6) using 40mm graded crushed stone aggregate 75mm thick as in Plinth Protection, etc. laid in alternate Bays, finished Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. |
| 31 | M&L25mm thick damp proof course to horizontal or vertical surfaces in cement concrete 1:2:4, type B-0 using 12.5mm graded stone aggregate including necessary formworkcomplete all as specified and directed. |
| 32 | Dismantling floor, hearth or all tiling including cement mortar bedding (but not backing coat), removing serviceable tiles to store and rubbish off the premises,complete all as specified and directed. |
| 33 | M&LColoured non skid ceramics tiles 7 to 8mm thick (square/ rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors over and including 15mm thick screed bed/bedding layer in CM 1:6set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing floor complete all as specified and as directed. |
| 34 | M&L Non skid ceramics tiles 7 to 8mm thick (square/ rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layerin cement mortar (1:4) complete all as specified and as directed. |
| 35 | M&LVitrified Ceramic Tiles 10 mm thick (square/ rectangular) in Light Shade, Polished, Area of Each Tilenexc. 0.36 Sqm as in vertical surface such as Skirting, Dados, Risers to Steps etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles, complete over 15 mm thick backing layer cement mortar (1:6) complete all as specified and as directed. |
| 36 | M&L Vitrified Ceramic Tiles 10 mm thick (square/ rectangular) in Light Shade, Polished, Area of Each Tilenexc. 0.36 Sqm as in vertical surface such as Skirting, Dados, Risers to Steps etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles, complete over 10 mm thick backing layer cement mortar (1:4) complete all as specified and as directed. |
| 37 | M&L Chequered Cement Concrete Tiles 200 x 200x 25 mm thick, Set in Screed bed of 20mm thick in Cement Mortar 1:6 and Jointed and pointed in Neat Cement Slurry with Grey Cement as in Floor, etc., complete all as specified and as directed. |
| 38 | M&L Preparing old decorated Plaster Surfaces of Ceiling and applying One Coat of oil bounded distemper complete all as specified and as directed. |
| 39 | M&L Preparing new plastered surfaces of wall andapplying Two Coats of DistemperOil Emulsionover a coat of primer andapplied over 2mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 40 | M&L Complete removal of existing Treatment of old decorated Surfaces of Walls andapplying Two Coats of DistemperOil Emulsionover a coat of primer andapplied over 2mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 41 | M&LPreparing non asbestos fibre cement building board surfaces of ceiling and applying Two Coats of DistemperOil Emulsionover a coat ofprimer on ceillingcomplete all as specified and directed. |
| 42 | M&L Preparing new Surfaces of Walls and applying Two Coats of Cement Based Paintover a coat ofprimer complete all as specified and as directed. |
| 43 | M&L Preparing new plastered surfaces of Walls and applying Two Coats of Exterior Emulsion anti fungus Paint Weather Coat over a coat ofPrimer (as per Manufacturer’s instructions), andapplied over 3mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 44 | M&L Complete removal of old decorated surfaces and Finishing walls with Premium Acrylic Smooth exterior paint and applying Two Coats of Exterior Emulsion anti fungus Paint Weather Coat over a coat ofPrimer (as per Manufacturer’s instructions), andapplied over 3mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 45 | M&L Mild Steel Flat Iron 25 x 3 mm, as in Holdfast for Door, Window Frames or Chowkats etc., cut to length or drilled hole and fixed with Screw, etc., grade of Steel conforming to Fe-290 Gde E-165, complete all as specified and as directed. |
| 46 | M&L Plain Cement Concrete type B-1, (1:2:4) (20mm graded crushed stone aggregate) as in Coping bed plate,hold fast etc,block benching,channeling slightly rounded or chamfered angle and throating including form work and finishing all exposed faces of cement concrete complete all as specified and as directed. |
| 47 | S&F Steel window without glazing bars but with FI/Z section for fixing of gauze and steel handle, peg stay complete all as specified and directed. |
| 48 | S&F Steel window side hung shutters including boxtype hinges with steel handle and steel pegs stay complete with glazing bars complete all as specified and directed. |
| 49 | S&F Steel ventilatorwith top hung shuttersincludinghinges with steel handle and steel peg stay with glazeing barscomplete all as specified and directed. |
| 50 | S&F Sheet Glass 5.0mm thick ordinary quality glazing with Wooden Beads or Oil Putty in Square or Rectangular, not exc. 0.50 Sqm, complete all as specified and as directed. |
| 51 | S&F Figured Glass 3.0mm thick, Pin Head / frosted type and glazing with Wooden Beads or Oil Putty in Square or Rectangular, not exc. 0.50 Sqm, complete all as specified and as directed. |
| 52 | Taking down Chowkat or Frame with shutters (without taking off Shutter from the Frame) exc. 1.50 Sqm but not exc. 4.00 Sqm Each, complete all as specified and as directed. |
| 53 | Taking down and refixing of Shutters of anydescription exc 1sqmbut n. exc 2 sqm each in same opening with necessary hinges , screws complete all as specified and directed. |
| 54 | S & F PVC door with chowkhats frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supply & fixing in opening as per specification & drawing.complete all as specified and directed. |
| 55 | S & F Factory made solid panel pvc door shutter with chowkhats 30mmthick (style) consisting of frame made out of M.S.tubes for top & bottom rails.M.S.frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S.frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined to gether with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 56 | S&F Flush Shutters 35 mm thick, Solid Core Construction with Block Board Core and Plywood Face Panels, Commercial type on Both Sides, complete all as specified and as directed. |
| 57 | S/F 30mm thick glazed and skeleton shutters open rebated and prepared to receive glass gauge etc.Divided into squares with plain chamfered or rounded, rebated sash bars, sizes of the members of the shutters as specified in SSR Part I, section 8, clause 8.23(a).complete all as specified and as directed. |
| 58 | S/F Galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm fitted with tinned tacles or galvanised wire staplescomplete all as specified and as directed.NOTE: Cost of Second Class Hardwood Bead-ing shall deemed to be included against Glazed and Skeleton Shutter. |
| 59 | S&F 200 mm aluminium anodisedbarrel tower bolt, of extruded sectionand fixed in position complete all as specified and as directed. |
| 60 | S&F Aluminium alloy Handle 150mm long, Extruded Section, Fabricated type, anodized and fixed, complete all as specified and as directed. |
| 61 | S&F Mild Steel Butt Hinges, size of Hinges 100mm, medium weight, Cold Rolled and fixed, complete all as specified and as directed. |
| 62 | S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet,cast or extruded sections and fixing boltsand sliding bolts of extruded sections or cast aluminium alloy all as directed complete all as specified and as directed. |
| 63 | S&F Floor door stopper 14cm long of aluminium alloy bodyand tongue, anodised,with hard drawn steel spring,fixed in repairs in floor complete all as specified and as directed. |
| 64 | S&F in repair 300mm, ordinary rat tail rod pattern door springs including roller and roller plate complete all as specified and as directed. |
| 65 | S&F Mortice lock of brass offour levers ,vertical type, size 100 mm, complete all as specified and as directed. |
| 66 | M&L Preparing new Steel or Iron Surfaces of any description,exe 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red Oxide, Zinc Chrome Primer, complete all as specified and as directed. |
| 67 | M&L Preparing new Wood and Wood Based Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Pink Primer, complete all as specified and as directed. |
| 68 | M&L Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturer\"s instructions, complete all as specified and as directed :-(a) Preparing and cleaning of fully drysurface as per IS:3067-1966.(b)Applying bitumineous primer @ 0.30 litre per Sqm of surface (c) Applying coat of hot applied bitumen 85/25 @ 1.20 Kg/Sq m of surfaces Applying a layer of APP based Polymeric Membrance; 3.0mm thick (minimum) weighing 3.60 Kilogram per Square Metre (reinforced) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction.(d) Applying one coat of Aluminium Paint @ 0.10 Litre per Sqm over APP based Polymeric Membrane. |
| 69 | M&L 15 mm thick screed bed in cm 1:3 mixed with WPC as per manufactures instruction finished even and smooth over RCC roof slab without using extra cement complete all as specified and as directed.Note-WPC shall be measured seperately. |
| 70 | S&F Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back or Angle Back Type) with 32mm dia Brass Chromium Plated Waste Fitting, a pair of Cast Iron Brackets duly painted including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 including taking down/out unserviceable Wash Hand Basin and connected Items, complete all as specified and as directed. |
| 71 | S&F 600mmx450mm bevelled edge mirror of selected quality glass mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass, screws and cup washers complete all as specified and directed. |
| 72 | S&F Rotational Moulded Polyethylene (HDPE) Water Storage Tank 1000 Litre Capacity (Cylindrical Vertical with Closed Top), Black in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I including provision of 25mm x 100mm GI nippples with check nuts for inlet, outlet wash and overflow pipecomplete all as specified and as directed. |
| 73 | S&F PTMT Ball Valve 20mm dia having mini -mum weight 210 Grams, high pressure with epoxy coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe and fixed complete all as specified and as directed. |
| 74 | Supply and fixing 25 mm bore gate valve cast copper alloy screwed down high pressure with clutch handle screwed both ends for Iron pipe complete all as directed. |
| 75 | S&F20 mm Gun-metal, globe or gate valves, with iron wheel head, screwedboth ends for iron pipe and fixed complete all as specified and as directed. |
| 76 | S&F 15 mm Gun-metal, globe or gate valves, with iron wheel head, screwedboth ends for iron pipe and fixed complete all as specified and directed. |
| 77 | S&F Vitreous China White Squatting Pan ‘ORISSA’ Pattern, size 580x440mm with ‘P’ or ‘S’Trap, Integral Foot Rest, providing Joints between Flush Pipe and Socket of WC Pan including Flushing Cistern and Flush Pipe, fixing with and including provision of cement Concrete Bedding complete all as specified and as directed. |
| 78 | S&F Vitreous China Colour Wash down Water Closet Pan (Pedestal Pattern) with \"p\" or \"s\" trap front or back inletincluding fixing Bolts with and excluding 10 litre capacity low levelFlushing Cistern matching with water closet colour with inlet ball valve float handle and providing 32mm dia PVC flush pipe including plastic water closet seat with flat botton cover (coloured) fixed with mild steel chromium plated or aluminium hinging device and making good disturbed Surfaces in Cement Mortar 1:3 and fixedcomplete all as specified and as directed. |
| 79 | S&F White PVC Flushing Cistern 10 Litre capacity, Low Level Valve Less, Syphonic Action type with Inlet, Ball Valve, Float and Handleincluding Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 and fixed complete all as specified and as directed. |
| 80 | S&F Towel Rail 600mm long of chromium plated brass metal fixed with and including Chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed. |
| 81 | S&F in repairs 20 mm dia decorative curtain rods of MS conduit with polymer linning etc. with decorative side dome and brackets complete all as specified and directed. |
| 82 | S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed. |
| 83 | S&F 15mm AngleStop valves cast copper alloy,fancy typewithchromium platedfor iron pipe or for unions and fixed complete all as specified and directed. |
| 84 | S&FBib tap, chromium plated , fancy type, screwedfor ironpipeor brass ferrule , 15 mm bore and fixedcomplete all as specified and directed. |
| 85 | S&F Pillar taps, cast copper alloy , with capstan heads, fancy tupe, chromium plated , screweddown high pressure, with long screwedshanksand fly nuts, screwedfor iron pipe , andfixedcomplete all as specified and directed. |
| 86 | Supply and Laying Steel Water Tubing 15mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed. |
| 87 | Supply and Laying Steel Water Tubing 20mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed. |
| 88 | Supply and Laying Steel Water Tubing 25mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed. |
| 89 | S&F 75 mm dia PVC pipes single socketed in any length with rubber ring joints, laid in trenches/floors or fixed to wallcomplete all as specified and directed. |
| 90 | S&F 110 mm dia PVC pipes single socketed in any length with rubber ring joints, laid in trenches/floors or fixed to wallcomplete all as specified and directed. |
| 91 | S&F 75 mm dia PVC (SWR) bends any radius fixed in any position, complete all as specified and directed. |
| 92 | S&F 110 mm dia PVC (SWR) bends any radius fixed in any position, complete all as specified and directed. |
| 93 | M&L Supply, laying, jointing and testing salt glazed stone ware drain pipe, grade \"A\" 150mm bore (internal dia) laid in trenches on concrete bed to required slope jointed and tested complete all as specified and directed.Note:- Excavation/earth work and concrete bed shall be measured and paid for separately |
| 94 | M&L Plain cement Concrete 1:3:6 type C2(Using 40mm graded agg) for concrete bed to drain pipes of 150mm bore, under and haunching against the sides of pipes after they are laid and tested in complete all as specified and directed. |
| 95 | M&L Pressed steel frames for doors with one or more rebates size of frame 125 x 60 mm including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed.Note :-Pressed Steel Frame should be filled with PCC 1:3:6 Type C-0 (Using 12.50mm graded stone aggregate) and cost of PCC shall be deemed included in quoted rate |
| 96 | S&F Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 97 | S&F Powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 98 | M&L Sheet glass 5.5 mm thick plain ordinary quality and glazing withWooden Beads or Oil Putty in Square or Rectangular, exc 0.5 Sqm in each pane complete all as specified and as directed. |
| 99 | S&F 12 mm thick Prelaminated particle bard, interior grade, prelaminated oneside with decorative choice lamination & otherside balancing white lamination, fixed in aluminium frame workcomplete all as specified and directed. |
| 100 | Dismantlingof wall & ceiling Boards (fibre,pulp,insulation etc. ),or insulation board/slabs/ blankets ,any thickness, including cover fillets complete all as specified and directed. |
| 101 | M&L Aluminium powder coated snap gridfor false ceiling of size 600 mm x 600 mm x 4 mm thickto support the boards/files with aluminium anodised main \"T\" section 36mm x 25mm x 1.40mm, Cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides including hanging arrangements with 1.6mm dia GI wire and anodised adjuster complete all as specified and as directed. |
| 102 | M&L 4mm thick non asbestos fibre cement building board fixed/inserted to Aluminium frame work, as in ceiling complete all as specified and as directed. |
| 103 | Dismantling AC Corrugated Sheets as in Roofing including Ridge or Similar Pattern Roof Coverings, complete all as specified and as directed. |
| 104 | S&F Pre-painted colour galvalume aluminium zinc coating GI based corrugated steelsheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 105 | S&F Pre-painted colour galvalume aluminium zinc coating GI based plain steelsheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 106 | Dismantling Wrought Iron or Mild Steel Work, viz. MS Flat Iron (Wind Tie) and Similar Work including MS Bolts, Nuts, etc., complete all as specified and as directed. |
| 107 | M&L Framed Work such as Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed. |
| 108 | S&F Rolled mild steel sections as in main and cross beams,hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors,fixed with angle cleats or other connecting plates of Fe-410-W(Gde-E-250) quality-B complete all as specified and as directed. |
| 109 | S&F Rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-A complete all as specified and as directed. |
| 110 | M&L Framed work as in doors or gates of angles or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering running rails and guides) and hanging also fastening and fixing complete Fe 410 -w(Gde E-250) quality B) complete all as specified and as directed. |
| 111 | Dismantling Timber Scantlings, 40 Sqcm and over in Section, in any Position, as in Unframed Work, complete all as specified and as directed. |
| 112 | Taking down carefully aluminium/copper conductor point wiring (light,fan,socket or power) completeincluding fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing(except those to be reused shall be kept in safe custodyat the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified and as directed. |
| 113 | M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets,regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fanpoint controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.(ii) Cutting Chases pinning deemed to be included in quated rate |
| 114 | All as per item No. 113here-in-before but one 3 pin 5 ampsswitch socket commbination on the independent board with other switch complete all as specified and directed. |
| 115 | All as per item No. 113here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed. |
| 116 | S&F Switch piano, flush type, Single pole one way, 5/6 Amps 230/240 Volts, white/ivory finish complete all as specified and directed. |
| 117 | S&FSwitch socket combination multipurpose 2 in 1, 3 pin 6 Amps 230/240 volt flushtype complete all as specified and as directed. |
| 118 | S&FSocket outlet 3/5 pin, 6 Amps, 240 volt flushtype complete all as specified and as directed. |
| 119 | S&FCeiling rose, surface bakelite, 65 x 50 mm,three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed. |
| 120 | S&F Ceiling fan regulator electronic Stepped type, solid state, , 240 volts,complete all as specified and as directed. |
| 121 | S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittingscomplete all as specified and as directed. |
| 122 | M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 6.0 Sqmm as earth lead drawninto rigid non metalic PVC conduit of size 20 mm dia including all fittingscomplete all as specified and as directed.Note:- Two runsof 6 Sqmm conductor as main wireand one run of 6 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. |
| 123 | S&F Bldg security light fittings 25 watts, minimumm system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and as directed. |
| 124 | S&Fin repair 20 W LED light fitting wall mounted batten 4\"ft , extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 20 watt,6500K including necessary connection complete all as specified and directed. |
| 125 | S&F LED Bulb 15 Watt suitable for baten holder complete all as specified and directed. |
| 126 | S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed. |
| 127 | S&FEpoxy powder coated sheet metal enclosure for DBs, double door , Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed. |
| 128 | S&F in repairsMCB SP,6 to 32 Amps, \"C\" series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. |
| 129 | S&F in repairs MCB SPN 6-32 Amps,\"C\" series 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. |
| 130 | M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x 6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI \"lightgrade\" pipe from upper end of earth plate upto equipments,20 dia bore GI pipe \"light grade\" as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I,testing on completioncompleteall as specified and directed. |
| 131 | Taking down of AC ceiling fan of any sweep & any height and opening the fan and oiling, greasing andreplacementofunserviceable accessories and servicing, complete overhauling and re-assembling and testing complete for efficient functioning and hanging it back in position including provn of 0.5 Sqmm copper flexible twin twisted cable (length not exceeding 0.5 metre) from ceiling rose to fan completed all as directed by the Engr-in-Charge. |
| 132 | M&L for painting of ceiling fans upto 1400mm sweep carefully, dismantling fan blades and paint with one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc complete all specified and as directed. |
| 133 | S&F Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all specified and as directed. |
| 134 | S&F Ventilating exhaust fan300 mm sweep 230 volt AC complete with louver and all accessories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing arrangement to wall connected with twin core twisted flexible copper conductor (23/.0076) of suitable size complete all specified and as directed. |
| 135 | Supply, laying / fixing / connecting, testing and commissioning of10 Sqmm x 2 core LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as directed by the Engr-in-Charge for the following ratings Note:- (i) Excavation,sand cushioning,brick will be measured and paid separtely. |
| 136 | Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge.Note:- Thickness after punning down shall be measured for payment. |
| 137 | M&L for Brick Sub Class \"B\" locally available best quality laid in trenches with width equal to length of the bricks, above sand cushioning for cable protection completeall as specified and as directed. |
| 138 | S&F Pipes galvanized,50 mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement completeall as specified and as directed. Note 1:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. Note 2-Contractor\"s supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embossed with contractor\"s firm name while carrying out any activities in defence area for better check of security purpose.Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs) |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy