Tender For Various Work Regarding Jarjar Line, Pole, New Line Etc In Area Of Edd-I Hapur In Business Plan 2024-25, FOR VARIOUS WORKS REGARDING JARJAR POLE/PLINTH/ERECTION LINE ETC., AND OTHER ASSOCIATED WORKS (10 Nos. Works.), IN BUSINESS PLAN (2024-25), IN THE AREA OFEDD-I HAPUR, UNDER EDC., HAPUR., 1 FOR VARIOUS WORKS REGARDING JARJAR POLE/PLINTH/ERECTION LINE ETC., AND OTHER ASSOCIATED WORKS, IN BUSINESS PLAN (2024-25), IN THE AREA OFEDD-I HAPUR, UNDER EDC., HAPUR (Third party inspection of the quality of all works will be conducted by the department.) 2 Carriage of all petty material of estimate, from Electricity store center, Hapur to 33/11KV Sub-Station/site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. 3 Carriage of all cable/conductor of estimate from JE Store/CTR/ESC, Hapur to site of work, including loading & unloading at both ends,as per direction of site incharge. 4 Carriage of ST Pole 11/13 mtrs. Long from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. 5 Carriage of PCC Pole 8.5/9 mtrs. Long from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. 6 Carriage of new 11KV outgoing VCBs, from Electricity store center, Hapur to 33/11KV Sub-Station with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. 7 Carefully & safely shifting of 11KV outgoing VCB-04Nos., from outside to inside the switchgear room at the place of removed VCBs and erection/Installation of 11KV VCBs after fixing of anchor GI nuts & bolts of proper size for completion of energisation work by providing required fixing material, as per RESPO/Drawing Norms, and as per direction of site incharge. 8 Erection of double pole structure with all accessories on ST Pole 11 mtr. long, fabrication and fixing of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 KV Pin insulator with Pin,Disc Insulator with Disc fitting etc., as per RESPO Drawing/Norms by providing all clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts, and jumpering etc work, and as per direction of site incharge. 9 Erection of Tri- pole structure with all accessories on ST Pole 11 mtr. long, fabrication and fixing of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 KV Pin insulator with Pin,Disc Insulator with Disc fitting etc., as per RESPO Drawing/Norms by providing all clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts, and jumpering etc work, and as per direction of site incharge. 10 Erection of double pole structure with all accessories on PCC Pole 8.5 mtr. long, fabrication and fixing of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 KV Pin insulator with Pin,Disc Insulator with Disc fitting etc., as per RESPO Drawing/Norms by providing all clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts, and jumpering etc work, and as per direction of site incharge. 11 Erection & Fixing of STP Pole 13 mtr. longin 11 KV line after digging of suitable pits including fixing of requisite all accessories as per RESPO Drawing/Norms by providing F-Bracket and holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts., and as per direction of site incharge. 12 Erection & Fixing of STP Pole 11 mtr. longin 11 KV line after digging of suitable pits including fixing of requisite all accessories as per RESPO Drawing/Norms by providing F-Bracket and holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts., and as per direction of site incharge. 13 Erection & Fixing of PCC Pole 9 mtr. longin 11 KV line after digging of suitable pits including fixing of requisite all accessories as per RESPO Drawing/Norms by providing F-Bracket and holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts., and as per direction of site incharge. 14 Laying, Stringing and final sagging of ACSR Rabbit Conductor on existing feeder for double cirucuit on existing pole including all fixing required old/new material/accessories & providing all fixing materials/accessores, as per RESPO/Drawing/site requirement/ Norms and as per direction of site incharge. 15 Laying , Stringing and final sagging of ACSR Rabbit Conductor, as per RESPO/Drawing Norms and as per direction of site incharge. 16 Laying , Stringing and final sagging of ACSR Dog Conductor, as per RESPO/Drawing Norms and as per direction of site incharge. 17 Laying of 140mm O/D PN-4PE-80 PN-4 grade UV stabilized HDPE pipe as per IS of 6meter, for laying of undergroundCable as per RESPO/Norms, including cost of above HDPE pipe, as per direction of site incharge 18 Laying of 11KV XLPE Cable 3x185Sqmm, undergound trenchless (495x2=990 Double Circuit) into HDPE Pipe, spare cable shall be left in the loop shape at both ends as per RESPO/Norms and as per direction of site incharge 19 Laying of 11KV XLPE Cable 3x185Sqmm, undergound (1090x2=2180 Double Circuit) into HDPE Pipe, spare cable shall be left in the loop shape at both ends as per RESPO/Norms and as per direction of site incharge 20 Laying of 11KV XLPE Cable 3x185Sqmm, undergound (230x2=460 Double Circuit) into, spare cable shall be left in the loop shape at both ends as per RESPO/Norms and as per direction of site incharge 21 Laying of 11KV XLPE Cable 3x185Sqmm, overhead (475x2=950 Double Circuit) as per RESPO/Norms and as per direction of site incharge 22 Laying of 11KV XLPE Cable 3x185Sqmm, overhead (560x1=350 single Circuit) as per RESPO/Norms and as per direction of site incharge 23 Digging of earth and refling with road restoration Kaccha charge as per RESPO/Drawing Norms and as per direction of site incharge 24 Grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Drawing/Norms by providing all grouting material and stay clamp made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops., as per direction of site incharge. 25 Earthing of supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts., and as per direction of site incharge. 26 Grouting of ST/PCC supports in CC 1:4:8 (Cement, sand & 40mm brick ballast) Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials., and as per direction of site incharge. 27 Providing and installation of maintenance free multifaceted proactive and corrosion free chemical earthing electrod size 80mm x 3000mm complete with 50KG backfill compound with all required accessories for Body/neutral earthing of Transformers, including cost of M.S. earth strip for connection the earth strip will be welded to the earthing and neutral support, as per RESPO/Norms and as per direction of site incharge. 28 Making and filling of 11KV Cable Jointing Kit 3x300Sqmm, indoor type, after duly plumbing and taping of suitable XLPE Cable, providing, fixing and crimping of proper size good quality lugs, including cost of lugs and tape etc., as per RESPO Norms, and as per direction of site incharge. 29 Making and filling of 11KV Cable Jointing Kit 3x185Sqmm, indoor type, after duly plumbing and taping of suitable XLPE Cable, providing, fixing and crimping of proper size good quality lugs, including cost of lugs and tape etc., as per RESPO Norms, and as per direction of site incharge. 30 Making and filling of 11KV Cable Jointing Kit 3x185Sqmm, outdoor type, after duly plumbing and taping of suitable XLPE Cable, providing, fixing and crimping of proper size good quality lugs, including cost of lugs and tape etc., as per RESPO Norms, and as per direction of site incharge. 31 Providing & Fixing of G.I. pipe 6dia Class-B over XLPE cable before mounting the cable at double pole. The work includes fitting of clamps, sealing of top and bottom of pipe and one end of pipe is to be burried under earth about 500mm earch including mounting and clamping the cable on double pole structure and making connection with overhead line at both ends. 32 Dismantling work and carriage ofold and jarjar scrap STP from site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road. 33 Dismantling work and carriage ofold and jarjar scrap pcc pole from site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road. 34 Dismantling work and carriage ofold and jarjar scrap 11KV XLPE Cable 3x185Sqmm as per Estimate from site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road. 35 Jumpering and line energisation work properly as per RESPO/Norms and as per direction of site incharge.