Tender For Repair And Maintenance Of Govt Buildings At 10 Nos Bops Choura Fwd Ii, Choura Base, K P Jattan, Kamaljit, Boharwadala, Chanduwadala, Rosse, Momanpur, Metla, Sadhanwali Of 27 Bn Bsf Under Shq Bsf Gurdaspur For Cfy 2024 Sh Electrical Instal, Gurdaspur-Punjab

Border Security Force-BSF has published Tender For Repair And Maintenance Of Govt Buildings At 10 Nos Bops Choura Fwd Ii, Choura Base, K P Jattan, Kamaljit, Boharwadala, Chanduwadala, Rosse, Momanpur, Metla, Sadhanwali Of 27 Bn Bsf Under Shq Bsf Gurdaspur For Cfy 2024 Sh Electrical Instal. Submission Date for this Tender is 27-05-2024. Building Repair Tenders in Gurdaspur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43414643
Tender For Repair And Maintenance Of Govt Buildings At 10 Nos Bops Choura Fwd Ii, Choura Base, K P Jattan, Kamaljit, Boharwadala, Chanduwadala, Rosse, Momanpur, Metla, Sadhanwali Of 27 Bn Bsf Under Shq Bsf Gurdaspur For Cfy 2024 Sh Electrical Instal
Open Tender
Indian
Punjab
Gurdaspur
27-05-2024

Tender Details

Repair And Maintenance Of Govt Buildings At 10 Nos Bops Choura Fwd Ii, Choura Base, K P Jattan, Kamaljit, Boharwadala, Chanduwadala, Rosse, Momanpur, Metla, Sadhanwali Of 27 Bn Bsf Under Shq Bsf Gurdaspur For Cfy 2024 Sh Electrical Installat

Key Value

Document Fees
Refer document
EMD
INR 5000.0 /-
Tender Value
INR 2.50 Lakhs /-

BOQ Items

Name of Work: Repair and Maintenance of Govt. buildings at 10 nos BOP"s Choura Fwd. II, Choura Base, K P Jattan, Kamaljit, Boharwadala, Chanduwadala, Rosse, Momanpur, Metla, Sadhanwali of 27 BN BSF under SHQ BSF Gurdaspur for CFY 2024-25. (SH- Electrical Installation)
Sl. No. Item Description
1Rewiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable and 1.5 sq.mm FRLS PVC insulated copperconductor single core cable as earth wire in existing urface/ recessed steel/PVC conduit including dismantling as required. Group B
2Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm
3Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm
5Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
6Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 75 mm X 75 mm X 60 mm deep
7Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch
8Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet
9Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 A switch
10Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet
11Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
12Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
13Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
14Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
15Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 A, 35 KA,TPMCCB
16Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 6 way , Double door
17Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
18Supplying and fixing Fan regulator of anchor make of steeped type including providing and fixing & making connections etc. as required of Make Havells/Bajaj/ Anchor/ Philips
19Providing and fixing of 20 Watt LED batten lighting fixture directly on ceiling/ wall, including connection, testing and dimentling the exsting complete etc. as required. Make - Havells or equivalent model and specification in Philips/Bajaj.
20Supplying and fixing of 230 mm Metal body Ventillation exhaust Fan suitable for single phase, 50 Hz, 230 volts, AC supply in existing wall including connection, testing etc as required. Make-Havells /Compton/ Orient/ Bajaj
21Providing and fixing of electric storage water heater of 25 ltr of 2 KWi/c fasteners with nut, bolts and washers including with connection, testing commissioning etc as required. Required. Make - Havells (Troica) or equivalent inBajaj/Rcold/Crompton/Jaquar
22Providing and fixing of 35 watt LED street light LED made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection, 42 mm dia X 0.85 Mtr long GI pipe brakcet for mounting on the pole/wall including bending the pipe to the required shape, flat iron clamps with nut, bolts and washers, painting with connection, testing commissioning etc as required. Make Havells (ENDURA SUNDOWN) equivalent model and specification in Philips/Bajaj.
23Providing and fixing of 50 watt LED Flood lightmade for energy saving, long life die-cast aluminium IP66 directly on the surface/wall including making connection, testing commissioning etc as required. Make Havells equivalent model and specification in Philips/Bajaj.
24Providing and laying of 3.5 x 35 sqmmone number PVC insulated and PVC sheathed / armoured XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Make- Havells/Polycab/KEI
25Providing and laying of 2 x 25 sqmmone number PVC insulated and PVC sheathed / armoured XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Make- Havells/Polycab/KEI
26Providing and laying of 2 x 25 sqmmone number PVC insulated and PVC sheathed / armoured XLPE power cable of 1.1 KV grade of following size in open laying as required. Make- Havells/Polycab/KEI
27SITC of outdoor type (front side open) totally enclosed feeder piller of size 450 mm400 mm x 250 mm depth with 900 mm long MS angle size 40 mm x 40 mm x 5 mm (four legs) fabricated with 02 mm thick MS sheet locking arrangement, pre-paint treatment with gre powder coated paint and 4 strip 200 Amp aluminium bus bar i/c installation by cement concrete and masonar bricks build foundation etc. as required.