Tender For Special Repair To Roof Treatment And Toilet Of Bldg No P-106 Of Bde Hq At Raiwala Mil Stn, raiwala-Uttarakhand

Military Engineer Services-MES has published Tender For Special Repair To Roof Treatment And Toilet Of Bldg No P-106 Of Bde Hq At Raiwala Mil Stn. Submission Date for this Tender is 14-06-2024. Shed Construction Tenders in raiwala Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

43413766
Corrigendum : Tender For Special Repair To Roof Treatment And Toilet Of Bldg No P-106 Of Bde Hq At Raiwala Mil Stn
Open Tender
Indian
Uttarakhand
raiwala
14-06-2024

Tender Details

Special Repair To Roof Treatment And Toilet Of Bldg No P-106 Of Bde Hq At Raiwala Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Jun-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-06-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 48214.0 /-
Tender Value
INR 24.10 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR TO ROOF TREATMENT AND TOILET OF BLDG NO P-106 OF BDE HQ AT RAIWALA MIL STN
Sl. No. Item Description
1Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exc 1.5 Sqm eachall as directed.
2Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exc 1.5 Sqm butnot exceeding 4.0 Sqm each.all as directed.
3Refixing of shutters in same opening of any descrption after easing and adjusting n exc 1.50Sqm each all as directed.
4Refixing of shutters in same opening of any descrption after easing and adjustingexc 1.00Sqm but n exc 2.00 Sqm each all as directed..
5S&F MS Fastner of size 200 to 250mm for fixing wooden door / window frame and like in postion all as specified and directed.
6S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
7S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
8M&L for 30mm thick Factory made solid WPC (Wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including S.S wire mesh shall be fixed with 15x15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density of the shall be as per manufacture instruction complete all as specified and complete all as specified and directed.
9S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as directed. Note- S S Butt hing measured and paid separately at relevant item
10S&F factory made 30 mm thick 100% solid WPC window glazed shutter / wire mesh shutter 95 mm x35mm thick. Made from WPC material with density not less than 800 kg/cum. All four corner are fusion welded & screwed with 8 x 50mm self-screws for additional strength. After joining all 4 corner clear space to be paneled with 5mm thick glass / S S mosquito mesh after glazing of inside of shutter 10 x 12mm pvc “L” shape bead to be nailed or sticked with shutter. Provided 2 Nos SS hinges of 100 mm, 1 Nos aluminium handle of 100 mm ,2 Nos aluminium tower bolt of 100mm and 01 peg stay for each shutter (Glazed and Gauzed) incl factory made 100 % solid WPC window frame 125 mm x 65 mm double rebated frame & mullion 125 x 80mm. made from WPC (Single extruded process) material comparising of virgin PVC polymer of K value 57-60 (suspension grade), calcium carbonate and natural fibers (Wood powder/ rice husk/wheat husk) and nontoxic additives fabricated with meter joints after applying PVC solvent cement & screwed with fully body treated star headed screws having minimum frame desity not less than 800 kg / cum, having good screw holding capacity (screw withdrawal strength of (min 990N). Minimum compressive strength of 58 N/mm2. Modulus of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water / mosquito proof & fire retardant & fixed in position with S S dash fasteners / hold fast of required dia and length. Window shall be provided with MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat including painting with countersunk holes at both vertical ends. Gap between the bars should not be more than 125mm. All as per specification drawing as directed. Note - (i) Glazed and Gauzed shutter both are deemed in this quoted rate (ii) Glass pane, wire mesh and grill are deemed in this quoted rate
11S&F for stainless steel barrel tower bolt of200 mm lengthofextruded section (ISI Marked). Complete all as specified and directed
12S& F for stainless steel barrel tower bolt of300 mm lengthofextruded section (ISI Marked). Complete all as specified and directed
13S&F forstainless steel handles,fabricated type, anodised 200 mm long,(ISI Marked)all as specified and directed.
14S&F for stainlees steel sliding door bolt of 300mm long, with hasp, staple (bolt type) complete all as specified and directed.
15S&F Stainlessnon megnetic steel butt hinges of size 100mm.(ISI Marked) complete all as specified and directed.
16S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm.complete all as specified and directed.
17S&F 300mm mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and directed.
18S&F in repairs S S peg set, 150 mm complete all as specified and directed.
19Dismantlingfloor hearth or wall tiling including cement mortar bedding (but not backing), removingand rubbish off the premises from MoD all as specified and directed.
20M&L for Non- skid coloured ceramictiles of any design and pattern, 300X300X7 to 8 mm thick, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles.Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE(I) .complete all as specified and directed
21M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8 mmthick, as in dado etc incl 10 mm thick rendering in CM 1:4, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I) .complete all as specified and directed
22Demolition of lime concrete in floors and paving exe 15 cm thick above ground floor (sunken floor)including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any othet loose material andremoving the demolished material outside the MOD land complete all as specified and directed
23M&L for PCC 1:1.5:3 type A-0 (Using 12.5mm stone aggregate)as in concrete angle-fillets with a radiaus of 75-100mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners mixed withintegral water proofing compound as per manufactur direction ) Note :- integral water proofing compoundwill be measured and paid seperately.
24M&L for applying two coats of acrylic polymer modified cementitiousflexible waterproof coating on horizontal and vertical surface for sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge . Note : Ponding test after water proofingcoating willl be done for ponding for 48 Hrs .
25M&L for 15 mm thick protection plaster in CM (1:4) in floor and wall with polymer modified repair mortar (SBR Latex liquid polymer as per manufactur direction) complete all as specified and directed Note :- The rates of SBR quoted shall be deemed to be included for these items
26M&L for providing 40 mm dia GI pipe (medium grade) spout projecting at least 300 mm beyond outer face of wall or all as specified and directed
27M&L for cementconcrete 1:7:12 type F2 (using 40 mm graded stone aggregate)as in filling of sunken portion complete all as specified and directed complete all as specified and directed
28M&L for 30 mm thick PCC Type B-0, 1:2:4, (using 12.5 mm graded stone aggregate)as in floormixed with SBR Latex liquid polymer as per manufactur direction complete all as specified and directed Note :- The rates of SBR quoted shall deemed to be included for these items
29Dismantling of cast iron or reinforced concrete drain pipes up to 110mm dia , jointed in cement mortar and taking out of trenches if required all as directed..
30S&F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors alldirected .
31S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors all as specified and directed .
32S&F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.all as specified and directed
33S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls all as specified and directed
34S&F 75 mm bore PVC (SWR) bends of any radius all as specified and directed
35S&F 75 mm bore PVC (SWR) bends of any radius with access door all as specified and directed
36S&F 110 mm bore PVC (SWR) bends of any radiusall as specified and directed
37S & F 110 mm bore PVC (SWR) bends of any radius with access door all as specified and directed
38S & F PVC (SWR) reducers of size 110 mm x75 mm all as specified and directed
39S & F 75 mm bore PVC (SWR) junction single (Single `T") equal or unequal with access door all as specified and directed
40S & F 110 mm bore PVC (SWR) junction single (Single `T") equal or unequal with access door all as specified and directed
41S & F 75 mm bore PVC (SWR) Vent Cowl all as specified and directed
42S & F 75 mm bore PVC (SWR) Multi floor trap including jointing with solvent cement all as specified and directed
43S & F 110 mm bore PVC (SWR) P Trap all as specified and directed
44S & F 75 mm bore PVC (SWR) floor Trap, plain with grating inclding jointing with solvent cement all as specified and directed
45S&F stackclamps out of 40mmx 3 mm flat iron includingbolts and nuts and securing ends of stays to walls or roof with fastner for 100 mm pipe complete all as specified and directed.
46S&F stackclamps out of 40mmx 3 mm flat iron includingbolts and nuts and securing ends of stays to walls or roof with fastner for 100 mm pipe complete all as specified and directed.
47Demolition of Stone slabs and tiles of any description or thickness in floors, approns, kitchen plateform / shelvesetc.Complete all as specified and directed
48M& L for 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including ointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and directed
49Demolition of brick work built in cement mortar in any description and position complete all as directed.
50M&L for Brick work with sub-class `B" bricks, straight or curved on plan exc 6 M mean radius built in cement mortar (1:6) all as specified and directed
51M&L for Brick work with sub-class `B" bricks, straight or curved on plan exc 6 M mean radius built in cement mortar (1:6) except brick work all as specified and directed
52M&L for Brick work sub-class `B" bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar CM1:4 with old size bricks all as specified and directed
53Taking down cement plaster in any thickness from brick or stonewalls , ceiling, facia etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegetation etc outside complex (MOD land) complete all as directed.
54M&L for Rendering 15 mm thick on fair faces of brick work or concrete walls surfaces in CM (1:6) finishedeven & smooth withoutusing extra cementall as specified and directed
55M&L for preparation of new orplastered or unplastered andapplying two coat ofdistemper acrylic oil emulsion white or tinted over and incl of one coat of alkali resistance priming paint and 1mm thick wall care putty on wall surface complete all as specified and directed
56M&L forRendering 15 mm thick cement plaster on concrete solid block walls in two coats 1st coat of 10 mm in CM (1:4) & 2nd coat of 5mm in CM (1:4) mixed with integral water proofing compound finishedeven & smooth withoutusing extra cement. Note :- Integral water proofing liquid will be measured and paid seperately.
57Supply only Liquied water profing compound of approved make all as specified and directed
58M&L for preparation of new orplastered or unplasteredsurfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed
59M&L for complete removal of existing treatment by mechanised system on walls internal or external surfaces in any height complete all as specified and directed.
60M&L for preparation of old orplastered or unplastered and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces all as specified and directed
61M&L for preparation of old surface of ceiling plastered including cornices and pillasters etc andapplying one coat of white wash on ceilingall as specified and as directed. .
62Dismantaling RCC /PVC water tanks and S&F new rotational moulded polyethylene water storage tank 1000 liters capacity, double layer (ISI Marked) construction (cylindrical vertical closed top), hoisted & fixed in position includingS&F 20 mm diaballvalves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed.
63Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .
64Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia .
65M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugsor laid in floors complete all as specified and directed
66Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugsor laid in floors complete all as specified and directed
67M&L for cutting chases on brick or concrete surface for concealed water tubing or / similar work ofgirth n.exc 10cm including making good of disturbed surfaces with PCC (1:2:4), type B0 using 12.5 mm graded aggregate complete all as specified and directed.
68M&L for Mild steel galvanized steel tubing of 15 mm bore (ISI Marked) with screwed socket joints as in concealed pipe work ,medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugsor laid in floors complete all as specified and directed
69Demolition of cement concrete (reinforced) of any position not otherwise specifically provided for and including reinforcement required to facilitate demolition upto and including on the roof top/mumty/parapet/RCC chajjas/RCC water tank and removal of debris and rubbish out sideMoD land complete all as specified and directed.
70M&L for RCC (1:2:4), type B1 (using 20mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc.all as specified and directed
71M&L for Form work to soffits of suspended slabs such as roof slabs, floor slabs and similar worknot exc 200 mm thick,rough finished, flat surface of concrete all as specified and directed
72M&L for mild steel TMT bars10mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
73M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
74S&F in repairs 15 mm bore Stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated with long shank and cupscrewed down high pressure with crutch or butterfly handleor concealed screwed both ends for iron pipe or for unions.
75S&F in repairs Stop anglevalves, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type) of size 15mm bore, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed. .
76S&F in repairs 15 mm bore chromium plated bib taps long body, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and directed
77S&F in repairs 15mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly nuts, screwed for iron pipe all as specified and directed
78S&F in repairs towel Rail 600 mm long fixedwith and including Chromimum plated brass screws and wooden plastic cleats (Min weight 190 gms)
79S&F in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing tosteel pipe or union all as specified and directed
80S&Fin repair Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long all as specified and directed
81S&F in repair to glass corner shelfof size 300mm fixed with chromium plated brass brackets complete all as specified and directed.
82S&F in repair for PVC connections 15mm size with PTMT nuts of length 600 mm including waste fitting
83S&Ftable top Wash basins of size approximate470 x 380 x 130 mm, vitreous china including waste fitting but exclusive ofwaste pipecomplete all as specified and directed..
84S&F in repairs for Grating round 127 mm diachromoum plated all as specified and directed..
85S&F in repair to 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed..
86S&F in repairs PVC valveless, syphonic action type flushing cistern (Dual action ISI Marked), lowlevel , white, with inlet ball valve, float and handle including brackets and flush pipe suitable for IWC of polyethylene of low or high density or PVC 32 mm dia for low level cistern for 10 litres capacity of approved make complete all as specified and directed
87S&F in repairs Vitreous china Squatting pan , "Orissa pattern, size 580x440 mm white, with integral foot restexcluding flushing cistern and flush pipe including connection to trap, to flushing pipe, anti-syphonage pipe, etc complete including making good to floor .all as specified and directed..
88S&F in repairs Vitreous China Half stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement all as specified and directed..
89S&F Brass CP urinal spreader fixing with 15 mm dia pipe.all as specified and directed..
90S&F in repairs Vitreous China wash down water closet pan (Pedestal pattern) white complete incl seat and cover, flush pipe incl all joints complete all as specified and directed..
91S&F in repair S S Jet spray with 1.5 mtr braided tube complete all as specified and directed
92S&F in repairs 15 mm diaHealth Faucet with hose & hook (complete set) fixed to angle / stop cock all as specified and directed.
93S&Fin repairstoilet paper holder chromium plated fixed to wall with chromium plated (CP) brass screws all as specified and directed
94S&F in repair to chromium plated towel ring complete all as specified
95S&Fin repair 32 mm dia lowdensity polyethylene pipe (LDPE) of pressure rating @ 6Kg f per Cm Cm Square fixed to walls, ceilings or in floors etc.all as specified and directed
96Demolition of existing roof treatment i.e APP membrane incl cement screed, brick tiling incl mud mortar or lime concrete and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance, scales, oil or any other loose material and removing unserviceable material, outside of A 1 defence land complete all as specified and directed. The work will be measured only after stage passing by AGE (I). Note: - (a) The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . (b) The rates quoted shall deemed to be included for these items.all as specified and directed
97M&L for PCC ( 1:2:4), type B-0 (using 12.5 mm graded stone agg) mixed with Liquid intergal water proofing compoud as per manufacturer direction and finishing the surface even and smooth with out using extra cement as in roof paddingtreatement to receive roof treatment complete all as specified and directed. Note :- liquid water proofing compound will be measured and paid seperately.
98M&L for PCC (1:1.5:3), type A-0 (Using 12.5mm stone aggregate)as in concrete angle-fillets with a radiaus of 75mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging ) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners mixed withLiquid intergal water proofing compoud (as per manufactur direction ) all as specified and directed Note :- liquid water proofing compound will be measured and paid seperately.
99Supply onlyLiquid intergal water proofing compoud
100M&L forone coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared as per manufacturer direction) as to be used for bonding of new concrete/ mortar to old surface. Note :- (i) The work is required to be carried out at non-accessible roof for double storey . (ii)The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof .(iii) The rates quoted shall deemed to be included for these items.
101M&L for water proofing treatment to non-accessibleroof slabwith APP based modified polymeric membrane as per manufacturer’s instructionswith following course of description below :- (a)Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6 Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer"s instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (c) Applying two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance Note :-: 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only. 2. The work is required to be carried out at non-accessibleroof slab for double storeyed.The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.
102E/M PORTIONDismantling and taking down U/Spoint wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
103Dismantling and taking downu/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified & as directed.Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
104Dismantling and taking down old damaged existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc.complete all as specified
105M&L for Point Wiring for one light Point controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealedPVC conduit ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia medium grade(Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates Note:-If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
106All as per Item No 105 above but for One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size complete all as specified and directed.
107All as per item no 105but forOne 3pin/5pin 5/6 Amps socket out let onindependent board with other switches, with cables 1.5 sq mm size complete all as specified and directed .
108All as per item No 105 abovebut with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point.all as specified and directed
109S&F switch modular, one way 6 Amps, 1 module 240 volts, AC, ISI marked all as specified.
110S$F switch modular one way 16 Amps, 1 module, 240 vlts, AC, ISI marked all as specified.
111S&F modular socket, 6 A, 2/3 pin combined 2 module complete, ISI marked all as specified
112S&F modular socket, 6 A/16 A 2/3 pin combined 2 module compelte ISI marked all as specified
113S&F ceiling rose surface bakelite 65/25 mm dia having three terminals all as specified
114S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
115S&F new LED building security light 1 x 25 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit protection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing ofsuitable bracket, including making necessary electricconnection with 1.5 sqmm , 3 core, PVC insulated copperconductor cable 1100 Volt grade complete all as specified and as directed.
116S&F sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 6 way with 200 Amps rated bus bar all as specified and directed .
117S&F MCBSPN 10- 32Amp " B" Curve240 V AC 10 KA repturingcapacity all as specified.
118S&F MCBSP 6 to 32 Amp "B" curve 10 KA repturingcapacity complete all as specified.
119S&F sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade concealed in walland open PVC conduit in ceiling and beam as per existing along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected withmain earth dolly including cuttingchasesand making good disturbed portionall as specified and directed . Note: Three runs of phase, netural ,earth wire and one run ofPVC conduit measured as one RM or one length.
120S&F fresh air fan AC single phase 230/240 Volt of size 300 mm sweep, metallic body powder coated painted finish, Power consumption- 50 W, Air displacement -1290 Cum/Hr, RPM-900 complete with louvers including making whole and grouting of nut bolts etc and making good the disturbed surfaces of wallcomplete all as specified and directed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail