Tender For Special Repair To External Electric Supply, Ug Cable And Connected Items Alongwith Sanctioned Minor Work At Karu Area Under Ge 860 Ews, Leh-Ladakh

Military Engineer Services-MES has published Tender For Special Repair To External Electric Supply, Ug Cable And Connected Items Alongwith Sanctioned Minor Work At Karu Area Under Ge 860 Ews. Submission Date for this Tender is 08-06-2024. Electrical Products Tenders in Leh Ladakh. Bidders can get complete Tender details and download the document.




Tender Notice

43411559
Tender For Special Repair To External Electric Supply, Ug Cable And Connected Items Alongwith Sanctioned Minor Work At Karu Area Under Ge 860 Ews
Open Tender
Indian
Ladakh
Leh
08-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Special Repair To External Electric Supply, Ug Cable And Connected Items Alongwith Sanctioned Minor Work At Karu Area Under Ge 860 Ews

Key Value

Document Fees
INR 500 /-
EMD
INR 81220.0 /-
Tender Value
INR 40.61 Lakhs /-

Attachment

FileName File Description File Size
Tender2.pdf Tender Document 0 KB
Tender1.pdf Tender Document 0 KB
BOQ_732729.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB
ece1d8b6-e90a-4b6c-a396-e504fcb98098.html Tender Notice 0 KB
Tender3.pdf Tender Document 0 KB

BOQ Items

Name of Work: SPECIAL REPAIR TO EXTERNAL ELECTRIC SUPPLY, UG CABLE AND CONNECTED ITEMS ALONGWITH SANCTIONED MINOR WORK AT KARU AREA UNDER GE 860 EWS
Sl. No. Item Description
1Excavation in trenches in hard / dense soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for laying of cables & foundation of poles, stay assembly, complete all as specified and directed by Engr-in-Charge.
2Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge.
3Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge.
4Taking out old unserviceable/serviceableun-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge. Note:- Serviceable un-reinforced concrete PCC cablecover kept in safe custody for reuse at site and unserviceable un-reinforced concrete PCC cable cover through in low lying area.
5Laying only old reinforced PCC cable cover of any size as retrieved from serial item No. 4.00 here in before complete allas directed by Engineer-in-Charge.
6M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
7M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge. Note: Punned thickness shall be measured and paid.
8S&F of galvanized iron pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wallincluding painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be deemed to included in the item rate qouted.
9Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by Engr-in-Charge.
10Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade 185 sq mm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as specified and directed by Engr-in-Charge. Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and PCC cable cover protection will be measured and paid separately under respective items.
11Description all as Srl item No. 10.00 here in before but for cable size of 150 sqmm 3.5 core.
12Description all as Srl item No. 10.00 here in before but for cable size of 120 sqmm 3.5 core.
13Description all as Srl item No. 10.00 here in before but for cable size of 70 sqmm 3.5 core.
14Description all as Srl item No. 10.00 here in before but for cable size of 50 sqmm 3.5 core.
15Description all as Srl item No. 10.00 here-in-before but for cable size of 35 sqmm 3.5 core.
16Description all as Srl item No. 10.00 here-in-before but for cable size of 25 sqmm 4 core.
17Description all as Srl item No. 10.00 here-in-before but for cable size of 16 sqmm 4 core.
18Description all as Srl item No. 10.00 here-in-before but for cable size of 16 sqmm 2 core.
19Description all as Srl item No. 10.00 here-in-before but for cable size of 10 sqmm 2 core.
20Taking out old UNSV LT panel board / Junction box of any size complete all as specified and directed by Engr-in-Charge.
21Supply, installation, testing and commissioning of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron framecomplete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall begrouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 400 Amps, 415 Volt, AC, 50 KA = 01 No (I/C) (b) MCCB 4 pole, 160 Amps, 415 Volt, AC, 25 KA = 02 Nos (O/G) (c) MCCB 4 pole, 100 Amps, 415 Volt, AC,25 KA = 02 Nos(O/G) (d) MCB SPN 63 Amps, 230 Volts = 10 Nos(O/G) (d)Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485Make : L&T (e)Phase indicating lamp = 03 Nos (R, Y, B)
22(f)Aluminium bus bar of capacity 600 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four
23Notes : 1. Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge. 2. Panel drawing shall be got approved from the GE before placing order.
24Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron framecomplete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall begrouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 250 Amps, 415 Volt, AC, 50 KA = 01 No (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC,25 KA= 01 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC,25 KA= 03 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G) (e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485Make : L&T
25(f)Phase indicating lamp = 03 Nos (R, Y, B) (g)Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four
26Notes : 1. Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge. 2. Panel drawing shall be got approved from the GE before placing order.
27Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron framecomplete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall begrouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 160 Amps, 415 Volt, AC ,50 KA = 01 No (I/C) (b) MCCB 4 pole, 63 Amps, 415 Volt, AC,25 KA= 02 Nos (O/G) (c) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G)
28(d)Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four
29Notes : 1. Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge. 2. Panel drawing shall be got approved from the GE before placing order.
30Supply, installation, testing and commissioning, in replacement,Junction box, cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick,complete with openable shutters in front and rear having proper locking arrangement includingincluding 04 Nos legs made out of angle iron of suitable size and height of each leg shall begrouted in PCC andaluminium busbar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge.
31Earthing complete withgalvanized steel earth plate electrode 60 cmx 60 cm x 6 mm thick buried directlyin ground (earth pit notless than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level,connecting to theGalvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron andsteelearth wire protected by provision of GI lightgrade pipe40 mmbore including provision of concrete pitmade from PCC ( 1:2:4) type B-1 (using20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angleiron40 x 40 x 6 mm and handle of 6 mmdia MS barmade to shape, GI light grade 20 mmbore pipefor watering perforated atbottom, 1.50metre long placed on top edge of earth plate, common salt &charcoalfilling, withfixing arrangement , funnel, wire mesh and earthwork in hard/dense soil, returning filling in and removal of surplus soilto a distance notexceeding50 metres, all as perelectrical plate No 5 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
32Supply, installation, commissioning of Glass Top Deep Freezer single phase 240 volt, 50 Hz of capacity 500 Ltr, Corrosion resistance Body, Eco friendly CFC Free, robust construction meant for heavy duty use with lock and key, including Heavy duty castor wheel at bottom complete all as specified anddirected by Engineer-in-Charge.
33Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA complete all as specified and as directed by Engineer-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail