Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-06-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 14-06-2024 |
| 2 | 31-05-2024 | Revised BOQ | BOQ | 07-06-2024 |
| Sl. No. | Item Description |
| 1 | Dismantling of Asbestos cement(corrugated, semi corrugated etc.) sheet in roof coverings complete all as specified and as directed. |
| 2 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 3 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 4 | Dismantling of wrought or mild steel work of any description such as in ladder work, bracing/supporting agle iron, roof top MS sheets, railings etc complete all as spcified and directed |
| 5 | S & F MS steel work in /rectangular trusses/angle and posts/purlin including special shaped washersetc., complete using but welded tubes confirming to IS 1161- 1979 graded St 240 withone shop coat of zinc chromate primer paint etc complete all as specified and directed. |
| 6 | M&L for Mild steel plates, chequered, 5mm thick Fe 410-W (Gde-E- 250) quality- A , cut in to shape and apply two coat synthetic enamel paint over a coat of primer all as specified and directed by Engineer-in-charge. |
| 7 | S & F mild steel screw bolts (machine made), diameter of neck 5 to 10 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5 cm but not exceeding 10 cm long complete all as specified and as directed. |
| 8 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 9 | M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed. |
| 10 | M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 25 mm thick finished even and fair complete all as specified and directed. |
| 11 | M&L Non-skid joint free coloured ceramic tiles (premium quality) 7 to 8mm thick (square/rectangular) area of each tile exceding 0.18sqmbut not exceeding 0.36 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 12 | M & L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed. |
| 13 | Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 14 | M&L coloured glazed ceramic tiles (premium quality) of size300x 200x7 or 350x250x7 mmor 450x350x7 mm thick, in vertical surfaces, skirting etc set and jointed in neat cement slurry and pointed in white cement mix with colouring pigment to match complete all as directed. |
| 15 | Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed. |
| 16 | Dismantling ceiling boards (Fibre/Pulp/Plywood) any thickness including cover fillets complete all as specified and directed. |
| 17 | M & L for anodised GI snap (Size of grid 605mm x 605mm ) frame work for false ceiling including GI wire 4mm thick as a suspender for GI snap grid framing all complete all as specified and as directed. |
| 18 | S&F 4 mm thick Non asbestos fibre cement building board decorative type( e-board)fixed in aluminium snap grid frame work with screws complete all as specified and directed. |
| 19 | Dismantling wooden fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section in unframed works, in any position complete all as specified and as directed. |
| 20 | M&L for 2nd class hard wood plain fillets ,square, rectangular or triangular in section ,clean sawn ,secured with nails or brads (sectional area exc13 sq.cm & n exc 25 sq.cm)as in studs of ceiling / sunshed./truss members complete all as specified and directed. |
| 21 | M&L for 2nd class hard wood plain fillets ,square, rectangular or triangular in section ,clean sawn ,secured with nails or brads (sectional area exc 6 sq.cm & n exc 13 sq.cm)as in studs of ceiling / sunshed./truss members complete all as specified and directed. |
| 22 | M&L for 2nd class hard wood plain fillets ,square, rectangular or triangular in section ,wrought ,secured with nails or bradsbut (sectional area exc 3 Sqcm &n exc 6 sq.cm) in filet complete all as specified and directed. |
| 23 | S&F wire netting of stainless steel wire 1.40 mm dia fixed with tinned tacks of stainless steel wire staples complete all as specified and directed. |
| 24 | S & F in repairs galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed. |
| 25 | S&F in repair Boarding, 40mm thick for 2nd class hard wood in scantling planed on both sides timber framed and fixed in ceiling complete all as specified and directed. |
| 26 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. |
| 27 | M & L for brick work with sub class \"B\" bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 28 | M & L for brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 29 | M & L rendering 5 mm thick in cement plaster in cement mortar (1:4) mixed with integral water proofing compound @3%by wt of cement over 10 mm thick backing coat in cm (1:4) on fair faces of brick work or concrete surface complete all as specified and directed.Note : water proofing compound shall be measured and paid separately). |
| 30 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 31 | Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed. |
| 32 | Taking down plastering on lathing (other than wire-netting), without removing lathing, in lime mortar (one side only measured in cases where both sides are plastered) complete all as specified and as directed. |
| 33 | Gl wire netting 0.90mm dia & 12mm mesh lathing to wood or metal studding, joists, etc. in walls. Ceilings, stanchions, beams, etc. including all laps, cutting & waste complete all as specified and directed. |
| 34 | Material and labour for plastering 10 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed. |
| 35 | Material and labour for plastering 10 mm thick on the other side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed. |
| 36 | Dismantalling of cement concrete (unreinforced) in ground floors and pavings not exceedings 15 cm thickness (below or above ground level), complete in all respect as specified and directed. |
| 37 | M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection/paving finish all as specified and as directed. |
| 38 | M & L for forming Construction joint 30 mm deep x 10 mm wide filled with sealing compound Grade \"A\" after priming the contact surfaces using suitable primer complete all as specified and as directed. |
| 39 | M&L Chequered cement concrete tiles 30 cm x 30cm x 25mm thick, set, jointed & pointed in neat cement slurry in floors with grey cement & pigment,glossy finished type over and including 15mm thick screed in CM(1:6)complete all as specified and directed. |
| 40 | M&L PCC in surface channels and drains type B1 (1:2:4) using 20 mm graded stone aggregate complete all as specified and directed. |
| 41 | M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed. |
| 42 | Add or deduct for each 25 mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed. |
| 43 | M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 44 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. |
| 45 | M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 46 | M&L for Granite (of any type)tile 20 mm thick machine cut ,bedded and jointed with gray cement slurry and pointed with white cement with admixiture of pigment to match the shade of granite stone indluding grindingand polishing complete all as specified and directed. |
| 47 | M & L for 20 mm thick Granite (of any type) tiles machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed. |
| 48 | M&L for 2 nd class hard wood scantling wrought finishedin any position 40 sq. cm & over in section including dismantling complete all as specified and directed. |
| 49 | Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed |
| 50 | Taking down chowkats or frames with shutters (without taking off shutter from the frames ) not exceeding 1.5 Sqm each complete all as specified and as directed |
| 51 | Taking down wooden door shutter area not exceeding 1.00 sqm each complete all as specified and as directed |
| 52 | Taking down wooden chowkhats or frames area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed |
| 53 | Taking down and refixing in same opening wooden door shutter area not exceeding 1.00 sqm each complete all as specified and as directed. |
| 54 | Taking down and refixing in same opening wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and as directed. |
| 55 | S &F second class hardwood plain,solid ,straight,chowkats and frames,wrought, framed rebated on the solid ,rounded or chamfered,put together with glue pinned at joints, complete in all respect as specified and directed. |
| 56 | S&F 2nd class Hardwood 35mm thick Glazed & skeleton shutters, open rebated & prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut & mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); to chowkats |
| 57 | Supplied and fixed 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete in all respect as specified and directed. |
| 58 | S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed. |
| 59 | S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed. |
| 60 | S&F Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheelcomplete all as specified and directed. |
| 61 | S&F Factory made single extruded WPC(Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp- ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge complete all as specified and directed.(M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ? Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed. |
| 62 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge complete all as specified and directed.(Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 63 | S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. |
| 64 | S & F 75 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. |
| 65 | S & F cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 66 | S & F aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 67 | S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. |
| 68 | S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. |
| 69 | S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 70 | Supply & fix sheet glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 71 | S&F in repair Aluminium anodised Brackets complete all as specified and directed. |
| 72 | S & F 20 mm dia harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed. |
| 73 | S & F floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 140 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 30 & 35 mm thickness of door shutter, fixed in floor complete all as specified and as directed. |
| 74 | Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. |
| 75 | Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. |
| 76 | Taking up or down 25 mm or 32 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. |
| 77 | Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 78 | Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 79 | Supplying & fixing to walls and ceilings or laid in floors 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 80 | Refixing 15 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed. |
| 81 | Refixing 20 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed. |
| 82 | Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., not exceeding 10 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed. |
| 83 | S & F stop valves of PTMT with long shank and cup (concealed type), any colour, high pressure, minimum weight 112 grams, screwed for steel tube for nominal size 20 mm complete all as specified and as directed. |
| 84 | S & F 15 mm nominal size, screw down bib taps, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed. |
| 85 | S & F 15 mm nominal size, screw down stop valves, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed. |
| 86 | S&F Chromium plated shower roses 125mm size of Std quality and approved make with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. |
| 87 | S & F aluminium anodised tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed. |
| 88 | S&F in repairs CP Soap dish complete all as specified and directed. |
| 89 | S & F PVC moulded 600 mm X 450 mm looking mirror of selected quality glass mounted on 6 mm thick commercial plywood & fixed to wooden plugs with chromium plated brass screws & cup washers complete all as specified and as directed. |
| 90 | S&F Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with brass chromium plated bracket guard and railing 60 cm long complete in all respect as specified and directed. |
| 91 | S&F Vitreous China wash basin, white, flat back, size 630x450mm (flat back or angle back type) including brackets, cutting for and pinning \"in brackets waste coupling, waste pipe, grating complete all as specified and directed. |
| 92 | S & F 15 mm nominal size, pillar taps, cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish complete all as specified and as directed. |
| 93 | S & F 32 mm nominal size, waste coupling of PTMT (half or full threaded), minimum weight 45 grams with including silicone sealant complete all as specified and as directed. |
| 94 | S & F vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 95 | S&F in repairWater Closet (squatt pattern) of vitruous china squatting pan of pattern \"ORRISA\" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cirstern and flush pipe) including connection to trap and flushing pipe anti syphon pipe etc complete including trap set in and incl concrete complete all as specified and directed. |
| 96 | S & F 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed. |
| 97 | S&F for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 98 | M & L for PVC connections 15 mm size with PTMT nuts of length 300/450 mm complete all as specified and as directed. |
| 99 | S&F Vitreous China Urinal, Half stall type, white (back or corner wall type) complete incl providing and fixing plugs beding urinal against wall in cm 1:2 security urinal plug with and incl 60mm long brass screws pointing around urinal back in cement fixing automatically flushing cistern with bracket, flush pipes grating and union for discharge pipe complete all as specified and directed. |
| 100 | S & F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (minimum weight 60 gms) complete all as specified and as directed. |
| 101 | S & F PVC (SWR), type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 110 mm dia, fixed to walls complete all as specified and as directed. |
| 102 | S & F PVC (SWR), type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed. |
| 103 | S & F PVC (SWR), type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 75 mm dia, fixed to walls complete all as specified and as directed. |
| 104 | S & F UPVC (SWR), type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed. |
| 105 | S & F UPVC (SWR) bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 106 | S & FUPVC (SWR) bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 107 | S & FPVC (SWR) vent cowl, 110 mm dia conforming to IS 14735: 1999 complete all as specified and as directed. |
| 108 | S & FPVC (SWR) vent cowl, 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 109 | S & FPVC (SWR) Tee(87.5°) single, 110 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed. |
| 110 | S & FPVC (SWR) Tee(87.5°) single, 75 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and as directed. |
| 111 | S & FPVC (SWR) Tee(87.5°) single, 110 mm dia with inspection door conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge. |
| 112 | Supply and fixed unplasticised PVC (SWR) Gully trap125/110 mm, setting and jointing with solvent cement complete in all respect as specified and directed.. |
| 113 | Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge. |
| 114 | M&L for PCC 1:3:6 type C1 as in concrete bed to drain pipe incl packing under haunching against the sides of pipes after they are laid and tested for 75/110mm dia pipe complete all as specified and directed. |
| 115 | M&L for preparation of new plastered or undecorated surfaces of wall/ceiling using wall care putty to fill the voids and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed. |
| 116 | M&L for applying one coat of cement based paint on old surface including preparation of surface complete all as specified incl Priming plastered and other surfaces with alkali resistant priming paint complete all as directed. |
| 117 | M & L for preparation of new plaster surface of walls etc and applying two coats of acrylic washable distemper over 1 mm thick wall care putty in two coats over a coat of primer (smooth bodied opaque finish surface) complete all as specified and directed |
| 118 | M & L for preparing of surfaces of walls by complete removal of existing treatment and applying two coats of acrylic washable distemper over wall care putty in two coats over a coat of primer (smooth bodied opaque finish surface) complete all as specified and directed. |
| 119 | M&L for Preparation of new plastered surfaces and applying two coats of OBD over a coat of alkali resistant primer complete all as specified and directed. |
| 120 | M&L for preparation of old decorated wood and wood based surface of any description not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint, complete in all respect as specified and directed by Engr-in-Charge. |
| 121 | M & L preparation of new surface & applying two coat of synthetic enamel paint to wooden surfaces exc 10 cm girth complete all as specified and directed. |
| 122 | Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge |
| 123 | Surface dressing not exceeding 15 cm deep in soft/ loose soil complete all as specified and as directed. |
| 124 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and getting out in soft/ loose soil complete all as specified and as directed. |
| 125 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 126 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 127 | M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 128 | M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 129 | M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge. |
| 130 | M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed. |
| 131 | M & L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. |
| 132 | M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 133 | M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 134 | M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 135 | M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 136 | M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 137 | M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. all as specified and as directed. |
| 138 | M&L Non-skid joint free coloured ceramic tiles (premium quality) 7 to 8mm thick (square/rectangular) area of each tile exceding 0.11sqmbut not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed. |
| 139 | S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed. |
| 140 | S & F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed. |
| 141 | S&F vitreous china urinal partition white of size 310 x 700 mm fixed to walls complete all as specified and as directed. |
| 142 | S&F ofstop/angle valves chromium plated, cast copper alloy with fancy type handles screwed down, screwed for iron pipe or for brass ferrule 15mm bore as in repair complete all as specified and directed. |
| 143 | S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed. |
| 144 | S & F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed by the Engineer-in-Charge. (MAKE : PRAYAG, Cat No: 152 or equivalent model in JEXON / POLYTUF / SHAKTI) |
| 145 | Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge. |
| 146 | Supplied and fixedFactory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete in all respect as specified and directed. |
| 147 | Factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/ Chowkhat of size 65 X 100mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face)& 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite / borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/ss dash fasteners of required dia and length complete as per direction of enineer-in-Charge (M.S. hold fast/lugs or SS dash fastener shall be paid for seperately)Note: For WPC solid door/windows frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 148 | Preparation of newly or previously untreated steel surface of any description not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge |
| 149 | Preparation of newly plastered surfaces on walls and applying two coats of white wash complete all as specified and as directed. |
| 150 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed. |
| 151 | M & L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 152 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 153 | M&L for point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cabel of 1100V grade drawn through PVC casing & capingminimum size 20 mmincluding accessories,fixed on surfaces of wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes 1.6 mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium screws for housing the switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cablefor earth continuity and connecting to common earth dollyincluding taking down old point wiringall as specified and directed by Engr-in-Charge. (a) One light point controlled by one switch |
| 154 | All as per item 153 above but for One 3 pin socket outlet 5 Amps on same board complete all as specified and as directed. |
| 155 | All as per item 153 above but for One 3 pin socket outlet 5 Amps on indpendent board complete all as specified and as directed. |
| 156 | Ditto all as per item No.153 above but with 2.50 sqmm single core multistranded copper conductor cable for 15 Amp socket outlet point on independent board. |
| 157 | Supply and fix switch piano flush type single pole, one way, 5/6 Amps complete all as specified and directed. |
| 158 | S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. |
| 159 | S&F switch piano flush type 15 amps single pole one waycomplete all as specified and directed by Engr-in Charge |
| 160 | S&F socket outlet 3 pin, 15 Amp, flush type complete all as specified and directed by Engr-in Charge |
| 161 | S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed. |
| 162 | S&F Electronic fan regulator dimmertype,450w , 250 voltcomplete all as specified and directed by Engr-in Charge |
| 163 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Five star rated with brushless direct current motor complete and old fan deposit to E/M yard complete all as specified and directed by Engr-in Charge |
| 164 | S&F lamp holder insulated body with back plate for batten fittings/angle holder as required and including taking down old damaged holder complete all as specified and directed by Engr-in Charge |
| 165 | S&F ofLED bulb 9 w highsutable for lamp holder complete completeall as specified and as directed by the Engineer-in-Charge. Make :Havells/CG/Philips /Wipro |
| 166 | Supply and fix 20Watts LED light fitting, basic all purpose surface and wall mounted LED batten 20Watts with aluminium housing and integrated electronic driver including 20W LED tube - 1No. fixed on surfaces of wall or ceiling including taking down the old fitting all as specified and as directed by the Engineer-in-Charge. Make :Havells/CG/Philips /Wipro |
| 167 | Supply and fix 45 Watts Environment friendly, new generation, aesthatically, ultra modern designed Recess mounting luminaire with high brightness SMD LEDs as light source suitable for Armstrong/Grid ceilingfixed to ceiling including taking down the old fitting all as specified and as directed by the Engineer-in-Charge. |
| 168 | Supply and fix 10 Watts environmental friendly, ultra moders, energy saving, surface mounted , decorative oval bulk headedge-lit LED luminaire comprising of high brighthess LEDsall as specified and as directed by the Engineer-in-Charge. |
| 169 | Taking down old damaged/broken sub main wiring of any size/capacity alongwith existing conduit pipe/casing and caping and removing the same from the site and making good the disturbed portion of the wall etc all as specified and directed by Engr-in-Charge. |
| 170 | S&F sub main wiringcomplete with two runs of 4 sqmmPVC insulatedunsheathed single core multistrand copper conductorcable of 1100 volts grade drawnthrough new non metalic rigid PVC casing capping onwall alongwith accessories fixed on walls/floors/ceilingwith one run of 4 sqmm PVC insulatedunsheathed copperconductorcable as earth continuity conductor all as specified and directed by Engr-in-Charge.Note:- Two runs of PVCinsulatedcable 4 sqmm+ one run 4 sqmmof earth wire and one run of casing/ capping including accessories shall be measured as one length. |
| 171 | S&F MCB distribution board made ofCRCA sheet, powder coatedpaint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 240volt 8 way MCB DB, SPN with 200 Amp rated bus bar shall conform to IP 38 protection incluidng taking down the old one all as specified and directed by Engr-in-Charge. |
| 172 | S&F MCB of rating 240 Volts,SPN 40 Amps including taking down the existing unserviceableall as specified and directed by Engr-in-Charge. |
| 173 | M & L for MCB SP 6-32 Amps, 240 volts , 10 kA ISI marked as per IS/IEC 60898-1 2002 , C -curve , IP 20 including taking out existing unserviceable complete all as specified and directed. |
| 174 | S & F and repair sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SP 20 Amps 240 volts complete all as specified and as directed. |
| 175 | Earthing complete with galvanisedsteel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5 below ground level connected to GI 4mm earth wire by means of bolts, nuts check nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15 mm bore light grade connected upto switch board incl 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No.3 of SSR Part I including dearth chamber of PCC 1:2:4 type B1 using 20mm grade aggregate with RCC cover slab 1:2:4 type B1, 40mm thick with 15mm dia MS bar 100mm C/C both ways and 6 MM dia MS hooks complete all as specified inlcuding testing on completion. |
| 176 | Supply & Lay underground XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning ofof size10sqmm 2 corecomplete all as specified and directed by Engr-in Charge . |
| 177 | Supply and fix exhaust fan, steel bodyAC single Phase. 230V of size 300mmsweep with, blades, and frame andlouvers complete and old unserviceable fan deposit to E/M yard complete all as specified and directed by Engr-in Charge . |
| 178 | Supply and fix electric Geyser, storage type steel body with steelinner tank and heating element upto2 KW capacity 25 litre,5 Starratedwith all accessories such as safety valve, thermostate,NRV, PVC connection pipeccomplete and old geyserdeposit to E/M yardcomplete all as specified Make -Havells/Bajaj/Crompton/Veenus |
| 179 | S&Fformodular 25 Amp motor starter AC switch with two modelwith socket 25 Ampincluding indication both red and green complete all as directed |
| 180 | Supply & Lay underground XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning ofof size16sqmm 2 corecomplete all as specified and directed by Engr-in Charge . |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail