Tender For Repair/ Rehabilitation, Roof Treatment And Roof Sheet Of Otm Accommodation In Sector B At Mil Stn Patiala Under Ge (South) Patiala, patiala-Punjab

Military Engineer Services-MES has published Tender For Repair/ Rehabilitation, Roof Treatment And Roof Sheet Of Otm Accommodation In Sector B At Mil Stn Patiala Under Ge (South) Patiala. Submission Date for this Tender is 07-06-2024. Shed Construction Tenders in patiala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43405582
Corrigendum : Tender For Repair/ Rehabilitation, Roof Treatment And Roof Sheet Of Otm Accommodation In Sector B At Mil Stn Patiala Under Ge (South) Patiala
Open Tender
Indian
Punjab
patiala
07-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair/ Rehabilitation, Roof Treatment And Roof Sheet Of Otm Accommodation In Sector B At Mil Stn Patiala Under Ge (South) Patiala

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-May-2024 Corrigendum Other 07-06-2024
2 28-May-2024 Corrigendum BOQ 07-06-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Tendernotice_1.pdf Tender Document 0 KB
c27918d3-ec1a-4184-9084-6f28808a9186.html Tender Notice 0 KB
BOQ_732529.xls Tender Document 0 KB
Tender15.pdf Tender Document 0 KB

BOQ Items

Name of Work: REPAIR/ REHABILITATION, ROOF TREATMENT AND ROOF SHEET OF OTM ACCN IN SECTOR ‘B’ AT MIL STN PATIALA UNDER GE (SOUTH) PATIALA
Sl. No. Item Description
1"Notes: (i) Please refer Schedule "A" Notes of tender documents.
2M&L for Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified and directed.
3M&L for Demolition of mud phuska on roof any thickness complete all as specified and directed.
4M&L for Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
5M&L for PCC 1:3:6, type B-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 25mm to maintain a slope of 1:100 ,complete all as specified and directed.
6M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
7M&L for Providing and laying3mm thick APP (Atactic Polyproplene Polymer) modifiedprefabricated five layer, weightnot less than 4.0 Kg/Sqm water proofingmembrane black finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer @ 0.40 ltr/sq.m by the samemembrane manufacturer ofdensity 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps Over the coat, 3mm th 5 layered APP membrane shall be laid using butane torch and sealling alljoints etc after the surface complete as per standard practice as per manufacturers instructions.The vital physical and chemical parameters of the membrane shall be as under - (i) Joint strength inlongitueinal and transverse direction at 23 degree C as 650/450N/5cms(ii) Tear strength in longitudinal and transverse direction as 300 / 250 N/.Softening point of membrane not less than 150 degreeC Cold flexibility upto 20 degree C when tested in accordance with ASTM (D05147) (iii) Thelaying of membrane shall be gotdone through the authorised applicator of manufacturer of membrane only, complete all as specified and directed.
8M&L for Plain Cement Concrete tiles 25cm x 25cm x 22-25mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished laid over 15mm thick screed bed in CM 1:4 complete all as specified and directed.
9S&F PVC(HDPE) SWR , 110 mm bore, single socketed in any length with rubber ring joints using solvent as per maunfacture instruction,fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts washing, nuts etc as in repairs after taking down existing damaged CI rain water pipe complete all as specified and directed. Note : Clamps will be measured and paid separately.
10S&F PVC (SWR) bends of any radius for 110mm bore complete all as specified and directed.
11M&L for taking down of existing pipe of any bore/material including bends and clamps and re-fixing the same after cleaning including jointing with cement joints in case of CI pipes or with rubber ring joints using solvent as per instructions also fixing of exisitng MS clamps complete all as specified and directed. Note : Any additional clamps fixed will be measured and paid separately.
12S&F for MS Clamps, Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay) and similar small articles conforming to Fe-290 Gde-E-165 all as specified and directed.
13S&F Dismantling plain or corrugated roof sheeting, any gauge, thickness/material, including nainital or similar pattern as on roof coverings complete all as specified and directed.
14S&F Pre-painted galvalume aluminum zinc coating GI based corrugated/semi corrugated steel sheet of 0.50mm thickness, minimum Tensile Strength 550 MPa, minimum weight 4.11 Kg/sq.m, of colour as approved as in roof covering/wall claddings, fixed with fasteners/self tapping screws as recommended by manufacturer complete all as specified and directed. Note : 1. Fixing of sheets will be done strictly according as per manufacurer"s instructions. 2. The rates for laps shall be deemed to be included in the quoted rate shall not be measured & paid separately.
15S&F Pre-painted galvalume aluminum zinc coating GI based corrugated/semi corrugated steel sheet of 0.45mm thickness, Min. Tensile Strength 550 MPa, of colour as approved as in crimp eave of size 1072mmx 1072mm, fixed with fasteners/self tapping screws as recommended by manufacturer complete all as specified and directed. Note : 1. Fixing of sheets will be done strictly according as per manufacurer"s instructions. 2. The rates for laps shall be deemed to be included in the quoted rate shall not be measured & paid separately.
16S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of min 0.45mm thickness, Min. Tensile Strength 550 MPa, of colour as approved as in ridge/gutter, fixed with fasteners/self tapping screws as recommended by manufacturer complete all as specified and directed. Note : 1. Fixing of sheets will be done strictly according as per manufacurer"s instructions. 2. The rates for laps shall be deemed to be included in the quoted rate shall not be measured & paid separately.
17S&F PCC 1:2:4 type B-0 (12.5mm graded stone agg.) as in roof kerbs or mud stops/ copings etc including weathering, slightly rounded or chamfered complete all as specified and directed.
18Taking down of PVCwater srorage tank ofof 300 to 500 ltrs capacity as located on terrace of the building complete all as specified and directed.
19S&F ISI marked doubled layered rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top / cover) 500 Ltrs capacity hoisted and fixed in position all as specified including 20 mm dia brass float valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm bore to connect GI tubing to PVC water tank complete all as specified and directed.
20Taking down of PVCwater srorage tank ofof 500 to 1000 ltrs capacity as located on terrace of the building complete all as specified and directed.
21S&F ISI marked doubled layered rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top / cover) 1000 Ltrs capacity hoisted and fixed in position all as specified including 20 mm dia brass float valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm bore to connect GI tubing to PVC water tank complete all as specified and directed.
22Labour for disconnecting existing tanks of any capacity upto 1000 Ltrs, setting aside (or lowering if required) for repairing, cleaning, etc. and hoisting if required reconnecting and S&F tank cover with nut & bolts and 20mm dia brass float valve, changing of chuk nuts,socketand re-fixing in position after cleaning the tank complete all as specified and directed.
23S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
24S&F 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
25S&F taking up or down existing steel tubing and connections, 20mm bore complete all as specified and directed.
26S&F 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and directed.
27S&F for Refixing 20mm bore GI steel water tubing medium grade fixed to walls complete all as specified and directed.
28S&F for Taking up or down existing steel tubing and connections, 25mm bore complete all as specified and directed.
29S&F 25mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and directed.
30S&F for Refixing 25mm bore GI steel water tubing medium grade fixed to walls complete all as specified and directed.
31S&F for demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed.
32M&L Brick work with sub class "B" bricks straight or curved on plan exceeding 6m mean raidus bulit in C:M 1:6 complete all as specified and directed.
33M&L for taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed.
34M&L for cement plastering 10mm thick in cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
35M&L for cement plastering 15mm thick in two layers in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer"s instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cementcomplete all as specified and directed. Note : WPC will be measured and paid separately.
36M&L for cement plastering 5mm thick in cemet mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
37M&L for Complete removal of existing treatment of any type/description from walls/RCC surfaces/ceiling/chajjas/roof projections etc with mechanical means/grinder complete all as specified and directed.
38M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order.
39M&L for applying 02 coats of interior emulsion paint (light shade) @ 10 sq.m/litre/2 coats by using roller/brush to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed.
40M&L for applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to ceiling surfaces over & including a coat of interior primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed.
41M&L for applying 02 coats of exterior emulsion paint (light shade) @ 5 sq.m/litre/2 coats by using roller/brush to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed.
42M&L for preparation of newly plastered surfaces of external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc and applying two coat of cement base paint @ 5 sq.m/kg/1 coat over & including a coat of exterior wall cement primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of cement based paint by using following brands of cement based paint and primer by brush or roller complete all as specified and directed.
43M&L for Dismantling MS works in any grade/ section/ position/ purlins/ rafters/ beams/ structures etc and the like works complete all as specified and directed.
44S&F MS hollow rectangular/square/circular tubes/pipes of YST 310 Grade as in frame work for roofs/rafters/purlins/chajjas/trusses/ columns/ struts etc and like similar items etc. complete all as specified and directed.
45S&F for plates/cleats/conn plates of Fe 410-W (Gde-E-250) quality A etc for frame work all as specified and directed.
46M&L for complete removal of existing treatment from steel and iron surfaces of any description including purlins/ rafters/ trusses/ columns/ struts etc and the like works n.exc 10cm in width or girth complete all as specified and directed.
47M&L for preparing steel and iron surfaces of any description including purlins/ rafters/ trusses/ columns/ struts etc and the like works n.exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
48S&F for dismantling Wall and false ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness/description, including cover fillets/frame work of any description complete all as specified and directed.
49S&F WPC/PVC Wall panelling of fluted/louvers/hollow sections/ of min. size 150 mm x 10 mm (colour/pattern as approved by AO) complete fixed in position in all respect including supply and fixing of all accessories like fasteners/screws/solvent etc complete all as specified and directed.
50S&F false ceiling of 12.5mm th gypsum board over and including concealed grid system complete fixed in all respect and all as per manufacturer"s instructions in one/two/three levels and making recess for light fittings as per pattern/design approved by AO and including supply and fixing of items all as specified as below :- Note : Thecomplete item shall be gotexecuted through the authorised applicator of manufacturer only all as specified and directed.
51S&F Suspended Plain Ceiling includes Perimeter Channel {Material-GI(IS513),YS-260Mpa,Finish- Galvanised 150GSM(IS27 )} is fixed along the perimeter of existing wall/ partition with the help of HILTI HPS - 1 (6x40) impact anchor, at 600mm centres.
52S&F Ceiling Angle {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is suspended by fixing it to the Gyproc® soffit cleat {GI(IS513)YS-260Mpa,Finish-Galvanised 150GSM(IS277) }. Soffit Cleat and Gyproc® Rawl Plug- Ø8x45mm {Material-IS 513 CR2 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} creating 1220mm x 1220mm grid.
53S&F Intermediate channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277) } is fixed to the Ceiling Angle with M6 x 12mm Hex Bolt & Hex Nut arrangement {Material–As per EN 10083 Finish – Zinc Plating} or with 2 Nos of Ø4.2x13 Gyproc® metal to metal screw {Material-Carbon steel EN-ISO 7049/50 Finish- Zinc Coating Thickness- 4.14micron.}
54S&F Ceiling Section {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is then fixed to the Intermediate Channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} with the help of Gyproc® Connecting Clip {Material-High carbon spring steel wire(BS970Gr.En42)-46-48HRC,Finish- Zinc plating 4-6 micron} and in direction perpendicular to the Intermediate channel at 457mm c/c.
55S&F Single layer of 12.5mm tapered edgePlain (conforming to IS 2095-Part 1:2011, ISI Certified board) is then screw fixed to ceiling section with 25mm drywall screws {Material-Carbon steel EN-ISO 7049/50,Finish-Case hardened Grey Phosphating} at 230mm centres on ceiling section & 150mm at periphery of ceiling.
56Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing withPro-Fill Jointing compound (Conforms to ASTM C475), Gyproc® Joint Paper tape.
57S & F anodised aluminium snap grid frame work (size of grid 605x605mm) for false ceiling all as specified including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
58M&L 12 to 12.50mm thick semi-perforated/pin holed particle board/tiles, 600x600 ± 5 mm in size fixed in false ceiling as per manufacturer"s instructions to existing frame work or on snap grid as in repairs complete all as specified and directed.
59M&L for repair to RCC ceiling, sunshades, Chajjas, Balconies, Columns, bands, beams, roof slab and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcherwith cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail