| 1 | Surface excavationn , exc 30cm deep and averaging 15cm deep and getting outin soft/loose soil etc complete all as specified and directed. |
| 2 | Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation etc or for laying of cables, pipes etc and getting out in soft/loose soil etc complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil. |
| 4 | Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point etc complete all as specified and directed. |
| 5 | PCC (1:4:8) type D-2, using 40 mm graded stone aggregate in fdn mass concrete, etc complete all as specified and directed. |
| 6 | M&L RCC work type B1 1:2:4 Nominal Mix, (using 20mm graded crshed stone aggregate)as in foundation including , raft,plinth beambases for column etc basement slabs under reamed piles and mass concrete etc complete all as specified and directed. |
| 7 | M&L RCC work type B1 1:2:4 (Nominal Mix) using 20mm graded crushed stone aggregateas incolumns , pillars , piers posts and struts etc complete all as specified and directed. |
| 8 | M&L TMT bars, 10mm dia and overcut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia etc complete all as specified and directed. |
| 9 | All as per ser item No above but 5mm to 10mm dia as in stirrups, spacers binders etc complete all as specified and directed. |
| 10 | M&L form work to flat side of concrete foundation , footing , bases of columns, raft and raft beams, sides and soffits (If any) of foundation and plinth beams and similar work, vertical or to batter etc complete all as specified and directed. |
| 11 | M&L form work to side of pillar, posts, struts, piers, columnsetc complete all as specified and directed. |
| 12 | S&Fstructural steel work as in roof truss made ofMS hallow section (Square/rectangular) pulines , crane , gantries,rails, fastenings and heavy brackets, framing (Beam, tee, angle, chanel or flat section including necessary cutting welding notching etc complete all as specified and directed |
| 13 | S&Fstructural steelas vertical post or single stanchions made ofMS hallow round/square pipemedium graded frame plates , caps , bases , splices, anglebrackates , cleats and other connections etc complete all as specified and directed |
| 14 | S&F plates (Plain or chequered ) Channels square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-290 Gde E 165 etc complete all as specified and directed. |
| 15 | M&L for mild steel screwe bolts (machine made) Dia of nick 16 to 20mm with hexagonal or square heads at one end and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm long but n.exc 30cm long etc complete all as specified and directed. |
| 16 | S&F for preparation of new steel surface/previously untreated surface of any description over 10cm width or girth & applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer etc complete all as specified and directed. |
| 17 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of ancolour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with selftapping screws etc complete all as specified and directed. |
| 18 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steelsheet 0.50 mm thick of ancolour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with selftapping screws etc complete all as specified and directed. |
| 19 | M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 20 | M&L 75 mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in sub floor, sub basefloors and pavings etc complete all as specified and directed |
| 21 | M&L for vibrator mouldedprecast concrete interlockingpaver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 grade and fixed with grey cement and no pigment including 25mm thick sand cussion and filled the joints with dry sand after laying the paver block etc complete all as specified and directed. |
| 22 | M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor fire resistant low smoke (FRLS) PVC insulated and unsheathed cable 1100 Volts grade confirming to IS-694 drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20 mm external dia) but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part-I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling including 1.5 mm FRLS PVC insulated unsheathed copper earth wire including sunken type pressed steel terminal boxes electro plated of suitable size with bakellite white/coloured top sheet cover 3.0 mm thick for one light point controlled by one way switch all as specified & directed. |
| 23 | All as per serial item No. 22 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board. |
| 24 | All as per serial item No. 22 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board. |
| 25 | All as per serial item No.22 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour. |
| 26 | Supply and fixing switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts. |
| 27 | Supply and fixing switch piano, flush type, single pole, one way, 15 Amp, 230 Volts. |
| 28 | Supply and fixing socket outlet, 3 pin (with 2 pin outlet also), 5/6 Amp, flush type, 240 Volts. |
| 29 | Supply and fixing socket outlet, 2 in 1, 3 pin, 5 and 15 Amp, flush type, 240 Volts. |
| 30 | Supply and fixing ceiling rose surface bakelite 65 mm x 50 mm with two or three terminal complete all as specified. |
| 31 | Supply and fixing decorative ultra slim liner LED lighting fixture with extended poly carbonate environmental friendly, energy efficient suitable for 16W to 20W with LED tube of model E-LITE LED pride and connecting up, complete all as specified and directed.Make : Havells cat part No. LHEXBLP7PN1W018 or equivalent as per Appx D |
| 32 | Supply and fixing sheet metal enclosuresdouble door type suitable for fixing MCB\"s, SPN with 200 Amps rated bus bar, 8 way, 240 Volts, etc complete all as specified and directed. |
| 33 | S & F MCB 32 Amp, single pole & neutral,240 Volt,C Curve,10 KA ISI Marked as per IS/IEC 60898-1 2002 etc complete all as specified and directed. |
| 34 | S & F MCB 6-32 Amp, single pole240 Volt C Curve,10 KA ISI Marked as per IS/IEC 60898-1 2002 etc complete all as specified and directed. |
| 35 | Supply and fixing 2nd class hard wood rectangular block open recessed of size 30cmx25cmx5cm depth with 3mm thick phenolic laminated sheet top cover fixed with suitable steel screws & PVC rawl plug (4 Nos),for DB complete all as specified & directed. |
| 36 | Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & directed.Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. |
| 37 | M/L for brick work with FLY ASH BRICKS(As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and etc complete all as specified & directed. |
| 38 | M&L for dry sand and punning for cushioning to under ground cable etc complete all as specified and directed.Note :- For the purpose of payment only punned thickness shall be measured. |
| 39 | M/L for 40 mm bore GI pipe ( Light grade ) for protection of LT cable fixed to walls/ poles/road crossing including clampsetc complete all as specified and directed. |
| 40 | M&L for drilling hole under road for laying of U/G cable through pipe of suitable size etc complete all as specified and directed. |
| 41 | Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre,charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers,PCCchamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified &directed. |
| 42 | M&L for galvanized steel water tubing medium grade of 20 mm bore with & including all fittings such as bends,elbow,tee,union etc. andfixed complete to wallswith using of clamps and ceilings or laid in floors including taking up or down CPVC/GI Water tubing and connections etc complete all as specified &directed. |
| 43 | M&L for galvanized steel water tubing medium grade of 50 mm bore with & including all fittings such as bend,elbow,tee,union etc.complete laid in trenchesincluding taking up or down CPVC/GI Water tubing and connections etc complete all as specified &directed. |
| 44 | M&L for galvanized steel water tubing medium grade of 80mm bore with & including all fittings such as bend,elbow,tee,union etc.complete laid in trenchesincluding taking up or down CPVC/GI Water tubing and connections etc complete all as specified &directed.Note for item No 42.00 to 44.00:- (i) Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.(ii) Before quoting the tender , contractor must see the feasiblity of site and see the location of site and must be ensure that no sewage line and cable will be damaged. |
| 45 | Boring of holes under road,pavement, hard standing by trench less technology using ultra sound technique and necessary machine including HDPE pipe of 250mm dia suitable for 0.4 mpa working pressure. |
| 46 | S&F20 mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipe, ISI marked.etc complete all as specified &directed. |
| 47 | Supply & fixingsluice valve ISI markedPN 1.6 ,complete with both ends for iron pipe including necessary earth work and also taking up or down unserviceable valveof following size:- |
| 48 | ( a) 50 mm size |
| 49 | (b) 80 mm size |
| 50 | S&F saddle piece with suitable drilled hole made out of mild steel flat iron 50 x 5 mm of size 50mm x 20mm for taking branch connection of 20 mm bore from 50mm bore main pipe line including necessary excavation & earth work in any type of soil etc complete all as specified & as directed. |
| 51 | M&L for construction of brick masonry valve pit ofsize 1350mm x 1000mm x 1200mm (internal dimension) (Type\"E\") all as Specified and as shown on drawing no. TD/2004/26 Sheet No 1/3 to 3/3including excavation and earth work in any type of soil, PCC in foundation, coping, plastering,fabrication of valve pit chamber cover made out of angle iron frame and MS plates of thickness 3 mm with locking arrangement, 50mm dia lock with 03 keys, including of openable arrangement by heavy duty MS Hings of suitable size painted with synthetic enamelled paint (Blue colour) over a coat of primer including grouting of frame in PCC or brick work with plaster and final touch with double layer of white wash etc complete all as specified and directed. |
| 52 | M & L PCC 1:2:4 type B2 using for make good the damage surface & floor etc complete all as specified &directed. |