}

Bids Are Invited For 1 Periodical Maintenance And Operation Of All Electrical And Mechanical Installations Of Terminal Building, Car Park Lighting, Substation Equipments (Except Dg Sets And Amf Panel), Glf Installations , Fire Fighting System Etc. On D, New Delhi-Delhi

Airports Authority Of India has published Bids Are Invited For 1 Periodical Maintenance And Operation Of All Electrical And Mechanical Installations Of Terminal Building, Car Park Lighting, Substation Equipments (Except Dg Sets And Amf Panel), Glf Installations , Fire Fighting System Etc. On D. Submission Date for this Tender is 04-06-2024. Alarm Systems Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43372083
Bids Are Invited For 1 Periodical Maintenance And Operation Of All Electrical And Mechanical Installations Of Terminal Building, Car Park Lighting, Substation Equipments (Except Dg Sets And Amf Panel), Glf Installations , Fire Fighting System Etc. On D
Open Tender
Indian
Delhi
New Delhi
04-06-2024

Tender Details

Bids Are Invited For 1 Periodical maintenance and operation of all electrical and mechanical installations of Terminal Building, Car park lighting, substation equipments (except DG sets and AMF Panel), GLF installations , Fire fighting system etc. on daily or weekly or monthly or quarterly or yearly basis as per maintenance schedule including preparation and maintenance of records or documents etc as per scope of work given in special conditions and technical specifications of contract etc complete as required. The contractor is required to deploy following minimum manpower in shift of eight hours on all days including holidays except on weekly off day-1.01) For Substation equipments- on all daysa) Wiremen/Electrician - 03 nos.b) Helper - 03 nos. 2 Periodical maintenance and operation of all electrical and mechanical installations of Terminal Building, Car park lighting, substation equipments (except DG sets andAMF Panel), GLF installations , Fire fighting system etc. on daily/ weekly/ monthly/ quarterly/ yearly basis as per maintenance schedule including preparation andmaintenance of records /documents etc as per scope of work given in special conditions and technical specifications of contract etc complete as required. The contractor is required to deploy following minimum manpower in shift of eight hours on all days including holidays except on weekly off day -1.02) For Terminal Buildings- on General dutya) Wiremen/Electrician - 01 no.b) Helper - 01 no. 3 Periodical maintenance and operation of all electrical andmechanical installations of Terminal Building, Car park lighting, substation equipments (except DG sets andAMF Panel), GLF installations , Fire fighting system etc. on daily/ weekly/ monthly/ quarterly/ yearly basis as per maintenance schedule including preparation andmaintenance of records /documents etc as per scope of work given in special conditions and technical specifications of contract etc complete as required. The contractor is required to deploy following minimum manpower in shift of eight hours on all days including holidays except on weekly off day -1.03) For Fire Fighting system and Pump room- on General dutya) Wiremen/Electrician - 01 no.b) Helper - 01 no. 4 Testing the BDV value by applying minimum 40 KV for 1 minute of 500 KVA transformers oil including submission of report as required. 5 Filtration andDehydration of transformer oil at site as per relevant IS Dielectric strength for transformers including submission of test reports before andafter dehydration of oil andreplacement of gasket if required installed at Aligarh Airport. (Item is to be executed if the BDV value of transformer oil is found below the stipulated value andafter prior approval of EIC). 6 Supply and Toping up the transformer oil in conservator tank upto a required level with new treated transformer oil (As per IS and approved make) as and when required. 7 Replacement of Silica gel for the 500 KVA transformer installed at Aligarh Airport 8 Servicing, Checking, Inspection, Repairing, overhauling and testing of CG Make, 12KV, 800A HT Vacuum Circuit Breaker (Main breaker) through OEM/ authorized service agency of OEM, as per OEMs recommendation and submission of test report to AAI complete as and when required. (Job includes checking of internal wiring of VCB and Panel and taking corrective action for proper operation of breaker/panel including minor repairing works.)6.01) 12KV, Make- CG, 800A 9 Servicing, Checking and Testing of following Make andCapacity Air circuit breakers(ACB) through OEM/ authorized service agency of OEM as per OEMs recommendation and submission of test report to AAI complete as and when required. (Job includes checking of internal wiring of ACB and Panel and taking corrective action for proper operation of breaker/panel).a) 800A, Make- L&T, 4 pole , Model- U POWER OMEGA (UW1-08N)7.01) Rate for First Year 10 Servicing, Checking and Testing of following Make andCapacity Air circuit breakers(ACB) through OEM/ authorized service agency of OEM as per OEMs recommendation and submission of test report to AAI complete as and when required. (Job includes checking of internal wiring of ACB and Panel and taking corrective action for proper operation of breaker/panel).a) 800A, Make- L&T, 4 pole , Model- U POWER OMEGA (UW1-08N)7.02) Rate for Second Year 11 Annual Comprehensive Maintenance Contract for 80 KVA UPS system (Make- 3EM Model- HoP) installed in Power house at Aligarh Airport. Job include quarterly visit of engineer, through OEM/ authorized service agency of OEM, performing periodical maintenance as per OEMs recommendations, attending unlimited complaints / breakdown calls, taking rectification action, supply and replacement of all spare parts as and when required except batteries, ensuring serviceability/ satisfactory working condition of the system, preparing records/ submission of reports etc. as per terms and conditions complete as and when required.8.01) First Year (Rate per UPS per Year) 12 Annual Comprehensive Maintenance Contract for 80 KVA UPS system (Make- 3EM Model- HoP) installed in Power house at Aligarh Airport. Job include quarterly visit of engineer, through OEM/ authorized service agency of OEM, performing periodical maintenance as per OEMs recommendations, attending unlimited complaints / breakdown calls, taking rectification action, supply and replacement of all spare parts as and when required except batteries, ensuring serviceability/ satisfactory working condition of the system, preparing records/ submission of reports etc. as per terms and conditions complete as and when required.8.02) Second Year (Rate per UPS per Year) 13 Annual comprehensive maintenance of combined refrigerated drinking water fountain (cooler) and bottle filling station of make- M/s Elkay Mftg., model no. EZS8WS_2G including detection and repairing of fault, replacement of all defective parts etc. complete as required.Note- 1 Job is equivalent to comprehensive maintenance of 1 No. complete system of RO Plant per year.9.01) Rate for First Year 14 Annual comprehensive maintenance of combined refrigerated drinking water fountain (cooler) and bottle filling station of make- M/s Elkay Mftg., model no. EZS8WS_2G including detection and repairing of fault, replacement of all defective parts etc. complete as required.Note- 1 Job is equivalent to comprehensive maintenance of 1 No. complete system of RO Plant per year.9.02) Rate for Second Year 15 Annual comprehensive maintenance of RO plant of 250 LPH capacity and control panel installed at Aligarh Airport including carrying out routine andpreventive maintenance work, replacement of all types of filters at least once every 06 months or earlier as and when required, replacement of membranes as per site requirement, detection and repairing of faults, repairing/rewinding of pump, replacement of defective parts etc. complete as required.Note- 1 Job is equivalent to comprehensive maintenance of 1 No machine per year.10.01) Rate for First Year 16 Annual comprehensive maintenance of RO plant of 250 LPH capacity and control panel installed at Aligarh Airport including carrying out routine andpreventive maintenance work, replacement of all types of filters at least once every 06 months or earlier as and when required, replacement of membranes as per site requirement, detection and repairing of faults, repairing/rewinding of pump, replacement of defective parts etc. complete as required.Note- 1 Job is equivalent to comprehensive maintenance of 1 No machine per year.10.02) Rate for Second Year 17 All inclusive annual comprehensive maintenance contract of DORMA make (Model- XLC 4200) electrically operated automatic sliding doors including replacement of defective mechanical andelectrical components of doors etc. The work includes monthly visit and attending any number of breakdowns as and when required by authorized service engineer, carrying out preventive and scheduled maintenance as per OEMs recommendation and as per direction of E-I-C and submission of service report during each visit- complete job.Note- Replacement of damaged glass is not covered in this item.11.01) Rate for First Year 18 All inclusive annual comprehensive maintenance contract of DORMA make (Model- XLC 4200) electrically operated automatic sliding doors including replacement of defective mechanical andelectrical components of doors etc. The work includes monthly visit and attending any number of breakdowns as and when required by authorized service engineer, carrying out preventive and scheduled maintenance as per OEMs recommendation and as per direction of E-I-C and submission of service report during each visit- complete job.Note- Replacement of damaged glass is not covered in this item.11.02) Rate for Second Year 19 Annual Comprehensive maintenance of Honeywell make (Model- DXC) intelligent Addressable fire detection and alarm system complete (excluding batteries, detectors, MCP, Hooters, control module, Response indicator, wires from fire alarm panel to other devices) installed at Aligarh Airport through OEM or authorized service provider of OEM. Job include quarterly visit of Engineer from OEM or OEMs authorized service provider, performing periodical maintenance of fire alarm and detection system as per OEMs recommendations, attending unlimited breakdown complaints received through email/ telephone, checking the proper functioning of complete fire alarm and detection system, taking rectification action of fire alarm system by rewiring/ rectification/ replacement of all parts (except batteries) of the fire alarm main and repeater panel, reprogramming in case of any fault in panel or replacement of faulty detectors/ MCPs/ Hooters/ control module etc, ensuring proper functioning of complete fire detection and alarm system as per special conditions of contracts complete as required.Note -- Spares such as detectors/MCPs/Hooters will be provided by AAI.12.01) Rate for First Year 20 Annual Comprehensive maintenance of Honeywell make (Model- DXC) intelligent Addressable fire detection and alarm system complete (excluding batteries, detectors, MCP, Hooters, control module, Response indicator, wires from fire alarm panel to other devices) installed at Aligarh Airport through OEM or authorized service provider of OEM. Job include quarterly visit of Engineer from OEM or OEMs authorized service provider, performing periodical maintenance of fire alarm and detection system as per OEMs recommendations, attending unlimited breakdown complaints received through email/ telephone, checking the proper functioning of complete fire alarm and detection system, taking rectification action of fire alarm system by rewiring/ rectification/ replacement of all parts (except batteries) of the fire alarm main and repeater panel, reprogramming in case of any fault in panel or replacement of faulty detectors/ MCPs/ Hooters/ control module etc, ensuring proper functioning of complete fire detection and alarm system as per special conditions of contracts complete as required.Note -- Spares such as detectors/MCPs/Hooters will be provided by AAI.12.02) Rate for Second Year 21 Rewinding andrepairing of 3 ph , 30 kW induction motor - pump set along with replacement of spares like bearings, bushes, bush coupling, sleeves, oil seal etc (except shaft andimpeller) including dismantling, transportation, assembling, testing and commissioning etc complete as required. (Dismantled material shall be retained by agency) 22 Rewinding andrepairing of 3 ph, 5.5 kW induction motor - pump set along with replacement of spares like bearings, bushes, bush coupling, sleeves, oil seal etc (except shaft andimpeller) including dismantling, transportation, assembling, testing and commissioning etc complete as required. (Dismantled material shall be retained by agency) 23 Rewinding/repairing of 7.5 HP submersible pump set as and when required with super enameled copper winding wire, including replacement of defective parts such as seal , bush, bearing etc including transportation charges and less for dismantled copper wire etc complete as required. (Dismantled material shall be retained by agency) 24 Rewinding/repairing of 7.5 HP open well submersible pump set as and when required with super enameled copper winding wire, including replacement of defective parts such as seal , bush, bearing etc including transportation charges and less for dismantled copper wire etc complete as required. (Dismantled material shall be retained by agency) 25 Charges for lifting andlowering of submersible pump set alongwith pipe lines, cable from existing bore of depth up to 300ft, as andwhen required i/c cost of labour, tools andplants, andminor items such as nut-bolt, rubber packing, etc. as required. 26 Rewinding of following fans i/c dismantaling, transporation and repairing/replacing the worn out bearing andreinstallation etc. complete as required. (Dismantled material shall be retained by agency)18.01) 1200mm sweep, Ceiling Fan 27 Rewinding of following fans i/c dismantaling, transporation and repairing/replacing the worn out bearing andreinstallation etc. complete as required. (Dismantled material shall be retained by agency)18.02) 400mm sweep, wall mounting Fan 28 Rewinding of following fans i/c dismantaling, transporation and repairing/replacing the worn out bearing andreinstallation etc. complete as required. (Dismantled material shall be retained by agency)18.03) 450mm sweep, Exhaust Fan 29 Rewinding of following fans i/c dismantaling, transporation and repairing/replacing the worn out bearing andreinstallation etc. complete as required. (Dismantled material shall be retained by agency)18.04) Sweep size up to 300mm, Exhaust Fan 30 Stamping of 200 Kg, platform type electronic weighing scales installed at Aligarh Airport from local state deptt of metrology including submission of certification etc. complete as required. 31 Painting of sheet metal enclosures of electrical equipments such as feeder pillars, distribution boards, electrical panel, frame, earth pits, fire fighting exposed pipelines etc. including cleaning the surface, painting with one or more coats of grey or any other colour of approved make including rewriting the identification the circuit, protecting and covering the electrical accessories during painting and removing after work is over etc. complete as reqd. 32 Painting of following items in one or more coats using Synthetic enamel paint of approved make including cleaning of surface etc., re-writing the identification letters etc complete as required.21.01) GI Poles of height of 8 Mtrs i/c cable junction box. 33 Painting of following items in one or more coats using Synthetic enamel paint of approved make including cleaning of surface etc., re-writing the identification letters etc complete as required.21.02) GI Poles of height of 6 Mtrs i/c cable junction box. 34 Refilling of fire extinguisher cylinder of following capacity as and when required.22.01) Capacity 4.5 kg (CO2 type) 35 Refilling of fire extinguisher cylinder of following capacity as and when required.22.02) Capacity 6.5 kg (CO2 type) 36 Refilling of fire extinguisher cylinder of following capacity as and when required.22.03) Capacity 4.0 kg (DCP pressure type) 37 Refilling of fire extinguisher cylinder of following capacity as and when required.22.04) Capacity 6.0 kg (DCP pressure type) 38 Providing andfixing of differential pressure switch in M.S. pipe line including complete connection etc. as required. 39 Calibration of clinometer of AMA make PAPI unit through OEM and submission of calibration report. 40 Calibration of 2 nos. 4KW, NASU make CCRs installed at Aligarh Airport, setting the CCR reading and submission of calibration report. 41 Providing, fixing, installation and commissioning of Controller/ spares/ materials of AMF suitable for 500KVA DG Set in existing LT Panel at Aligarh Airport complete job as per requirement of site. The work include provision of AMF materials, installation in existing LT panel including complete wiring, connection, termination with existing bus bar, interconnection with existing breakers, etc. complete as required. 42 Supply of 6-32 Amp, SP, C series, 10 kA MCB 43 Supply of 63 Amp, DP, C series, 10 kA MCB 44 Supply of 63 Amp, TPN, C series, 10 kA MCB 45 Supply of 20A, 500V, 80kA DIN type HRC fuse link as per site requirement 46 Supply of 5/6 amps one way switch, Modular type ISI marked as per site requirement 47 Supply of 3 pin 5/6 amps socket outlet, Modular type ISI marked as per site requirement 48 Supply of S.P. 15/16 amps, one way switch, Modular type ISI marked as per site requirement 49 Supply of 6 pin 15/16 amps socket outlet, Modular type ISI marked as per site requirement. 50 Supply of 2.5 MFD 230V Capacitor 51 Supply of Electronic fan regulator 52 Supply of maintenance free lead-acid Batteries 12V, 180AH capacity in charged condition, as andwhen required. 53 Supply of maintenance free lead-acid Batteries 12V, 130AH capacity in charged condition, as andwhen required. 54 Supply of sealed, maintenance-free lead-acid batteries rated at 12V, 42AH in charged condition as per site requirement. 55 Supply of 12 volt, 7 AH nominal SMF battery for Fire panel make-- Amaron Quanta or equivalent 56 Supply of Flame Retardant LSH PVC insulated single core, 1.5 sqmm copper conductor wire suitable upto 1100V grade conforming to IS-694/2010 with latest amendments of AAI approved make complete as required. 57 Supply of Flame Retardant-LSH PVC insulated single core, 2.5 sqmm copper conductor wire suitable upto 1100V grade conforming to IS-694/2010 with latest amendments of AAI approved make complete as required. 58 Supply of Flame Retardant-LSH PVC insulated single core, 4 sqmm copper conductor wire suitable upto 1100V grade conforming to IS-694/1990 with latest amendments of AAI approved make complete as required. 59 Supply of PVC insulated PVC sheathed Industrial flat cable 3C x 4sqmm, copper conductor of 1100V grade conforming to IS-694/2010 with latest amendments of AAI approved make complete as required. 60 Supply of 4C X 4sqmm PVC insulated PVC sheathed copper conductor unarmoured cable of 1.1kV grade conforming to IS-7098 (part-I) with upto date amendment complete as required. 61 Supply of 4C x 16 sqmm XLPE insulated PVC sheathed aluminum conductor armoured power cable of 1.1KV grade conforming to IS-7098 (part-I) with upto date amendment complete as required. 62 Supply of 4C x 25 sqmm XLPE insulated PVC sheathed aluminum conductor armoured power cable of 1.1KV grade conforming to IS-7098 (part-I) with upto date amendment complete as required. 63 Supply of 5kV, 6 sqmm airport lighting cable as per AAI technical specifications complete as required. (Cable must be supplied in single roll not in pieces) 64 Supply of cable jointing cast resin compound (resin and hardener in separate pack) for cable joints in container size of about 500gms. 65 Supply of 9 Ltr. Capacity MS Bucket painted in post office red colour with prior coat of Red Oxide paint and written with white paint FIRE etc. complete as required. 66 Supply of driver for the 16 Watt LED downlight fixture of Make- Wipro, Model- 1614. 67 Supply of driver for the 36 Watt LED 2x2 light fixture of Make- Bajaj, Model- BZRSQL 36W GZ1WH 68 Supply of 20/22W LED tubelight fitting 4 feet, (Appox.) including driver with aluminum housing suitable, suitable for surface mounting including batten etc. as per specification complete, as required. (Similar to Havells CAT No. LUMILINE PLUS or equivalent) 69 Supply of artificial respiratory system/ resuscitation kit 70 To carry out the item of work as per requirement of site from the CPWD schedule of rates (Electrical DSR - 2022) as per CPWD specifications complete as required. (Total amount of Rs. 1,00,000.00 (inclusive of GST & 1% L. Cess) is kept for -DSR Items-2022)NOTE- The rate may be quoted in the following manner-(i) If quoted Rate is Rs. 90,000/- then the Percentage will considered as 10% below DSR 2022.(ii) If quoted Rate is Rs. 1,00,000/- then Percentage will considered as 0% above/below DSR 2022.(iii) If quoted Rate is Rs. 1,10,000/- then Percentage will considered as 10% above DSR 2022.NOTE- 1) Items shall be executed from DSR-2022 rate at the quoted percentage as per site requirement.2) Basic rate of DSR shall be calculated after deducting GST component.

Key Value

Document Fees
Refer document
EMD
INR 207929.0 /-
Tender Value
INR 1.03 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail