Tender For Repair/Replacement Of Roof Treatment, Sunken Treatment Ci Pipes, Gi Pipes Including Connected Works In Otm Accn In The Area Of Age B/R-I Ge (West) Delhi Cantt-10, delhi-Delhi

Military Engineer Services-MES has published Tender For Repair/Replacement Of Roof Treatment, Sunken Treatment Ci Pipes, Gi Pipes Including Connected Works In Otm Accn In The Area Of Age B/R-I Ge (West) Delhi Cantt-10. Submission Date for this Tender is 01-06-2024. Shed Construction Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43347028
Tender For Repair/Replacement Of Roof Treatment, Sunken Treatment Ci Pipes, Gi Pipes Including Connected Works In Otm Accn In The Area Of Age B/R-I Ge (West) Delhi Cantt-10
Open Tender
Indian
Delhi
delhi
01-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair/Replacement Of Roof Treatment, Sunken Treatment Ci Pipes, Gi Pipes Including Connected Works In Otm Accn In The Area Of Age B/R-I Ge (West) Delhi Cantt-10

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

Attachment

FileName File Description File Size
e23f1483-88c5-4d06-94e0-c0bb0274fd2e.html Tender Notice 0 KB
BOQ_731149.xls Tender Document 0 KB
PS33.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: Repair/Replacement of Roof treatment, sunken treatment, CI Pipe, GI Pipes including connected work in OTM accn in the area of AGE B&R-1 under GE (West) Delhi Cantt-10.
Sl. No. Item Description
1M&L for flush pointing to bricks laid flat or brick tiles in pavings /roof in C:M 1:3 mixec with 5% crude oil by weight of cement including racking out of existing joints or brick tiles complete all as specified and directed
2M&L 40mm thick brick tiles laid over and including 15mm thic cement mortar 1:6 and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska complete all as specified and directed including dismantling old brick tiles.
3S&F in repair 100mm dia CI bends or diminishing pieces fixed to wall/floor with lead joint complete all as specified and directed.
4S&F in repair 100mm Cast iron soil, waste and vent pipe in any length with or without ears, with lead joints, laid in trenches or fixed to wall in repair complete all as specified and directed.
5S&F 100mm bore CI vent cowl complete all as specified and directed
6S&F 100mm bore CI tee, Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fixed with lead joint complete all as specified and directed.
7S&F in repair 75mm dia CI bends or diminishing pieces fixed to wall/floor with lead joints complete all as specified and directed.
8S&F in repair 75mm Cast iron soil, waste and vent pipes in any length with or without ears, with lead joints, laid in trenches or fixed to wall in repair complete all as specified and directed.
9S&F 75mm bore CI tee, Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with lead joint complte all as specified and as directed.
10M&L stack clamp made of 50 mm X 5 mm flat iron and 16 mm dia round iron stay including nut bolts and securing ends of stay to wall or roof suitable for 110 mm bore pipe complete all as specified and directed.
11M&L for Chipping of spoiled and loose concrete and cleaning rust from reinforcement by sand blasting scrubbing down concrete surface with wire brushes, cleaning with water, allowed to dry and applying a layer of anti rust and then Zincrich epoxy primer all as specified followed by a layer of bonding coat & then guniting over steel welded mesh 2mm dia of wire and aperture 75mm total thickness of guniting not exc 40mm thick (average thickness) with cement mortar 1:2 using OPC 43 grade cement and finally applying cement plaster over guniting surface of required thickness to give even, uniform, and smooth finish conforming to proper geometrics in cement mortar 1:3 to match with the existing surface as in sides and soffits etc. slabs, Chajjas, fins, facias, parapets, beams and columns etc complete including necessary scaffolding, shuttering, necessary chases to brickwork or RCC members at any height up to 4 storey building complete all as directed. Note: Steel Welded mesh is to be welded with existing reinforcement. The Cost of welded mesh is deemed to be included in the unit rate quoted and the work to be carried out up to 4 storey bldgs/in floor roofs complete all as specified and directed.
12M & L Rendering 5mm thick in ready mix plaster on ceiling to be finished even and fair (without using extra lime or cement)as in patch works or whole work including taking down cement plaster complete all as specified and directed..
13M & L for brick work with sub class " B" brick straight or curved on plan exc. 6 mtrmean radius built in cement mortor1:4 including all arrangement including demolition brick work complete all as specified and directed.
14M & L Rendering 12-15mm thick in ready mix on brick workor concrete surfaces to be finished even and fair (without using extra lime or cement)as in patch works or whole work including taking down cement plaster complete all as specified and directed.
15M & L Rendering 12-15mm thick in ready mix on brick workor concrete surfaces to be finished even and fair (without using extra lime or cement)as complete all as specified and directed..
16M & L for preparation of new surfaces of wall and apply two coats of distempering walls with distemper oil emulsion, white or tinted over and including a coat of primercomplete all as specified and directed.
17M&L for Preparation of new surfaces (Plastered or un-plastered) of walls or ceiling and applying three coats of white lime wash,complete all as specified and directed.
18S&F false ceiling with powder coated GI gridof size 600x600 mm using main Tee of size 24x28x0.40mm prepunched to accept cross tee of size 24x28x0.40mm and wall angles of size 25x25x0.40mm fixed with wall around of size with and including 4mm thick fiber cement board white colour designer tiles as approved by GE of size 595x595 mm placed in the grid and held in position duly suspended by 4mm dia GI wire hanger from the roof with holding down clips, butter fly clips and necessary provision for light fixture etc complete as per manufacturers instructions complete all as spd & directed including dismantling old false ceiling any type.
19Refixing/resecuring of false Ceiling board andsnap grid frame workincluding providing 4mm dia GI wire as in hanger complete all as specified and directed .
20S&F in repair vitreous China wash down water closet pan (pedestal pattern), white and connection with cistern copmlete complete all as specified and directed.
21S&F in repair plastic water closet seat cover, white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device of approved colour and as per existing model complete all as specified and directed.
22S&F in repair 10 ltrs capacityPVC low level flushing cistern complete with syphone handle lever PVC bend including connecting to WC and fixing on walls with bracket complete all as specified and directed.
23S&F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110mm bore of pipecomplete all as specified and directed.
24S&F in repairPVC (SWR) bends any radius110mm bore of pipe complete all as specified and directed.
25M&L for preparation of old treated surfaces of wallsand applying one coat of oil bound distemper complete all as specified and directed by Engr-in-Charge (Note :- Height of building upto 04 storey)
26M&L for preparation of old treated surfaces of wallsand applying one coat of cement base paint using spray gun/roller brushes complete all as specified and directed by Engr-in-Charge (Note :- Height of building upto 04 storey)
27M&L for complete removal of old treatment and preparation of old plastered surfaces of walls and applyingtwo coats of oil bound distemper over and including a coat of 1 mm thick wall care putty wherever required to bring uniform surafce complete all as specified.
28Dismantling Brick tiles or terracing tiles, single layer on roofs including thatching any type, demolition of mud phuska etc including cleaning the surface by water/airpressure and removal of debrish beyond MOD land complete all as specified and directed ( Note: height of building upto 04 story).
29M&L for brushing neat cement slurry with 3.Kg of cement per sqm complete all as specified and directed ( Note: height of building upto 04 story).
30M&L for providing cement concrete 1:2:4 type B-I 20mm graded in roof kerb or mud slops, rounded or chamfered on edges, plinth courses, coping, kneelers, apex stone, kerb water tough and the like including weathering, slightly rounded or chamfered angles and throating as directed) complete including necessary form work all as specified and directed ( Note: height of building upto 04 story).
31M&L for rendering 10mm thick cement mortar 1:4 on fair face of brick work or concrete surface complete all as specified and as directed ( Note: height of building upto 04 story).
32M&L for water proofing treatment to roof surface with APPwater proofing membrane 3mm thick & weighing not less than 3.0 kg/sqm of approved make black finish& reinforced with non woven polyester matt of min 150 gm/sqm laid over a coat ofbitumen primer conforming to IS-3384 @ 0.4 Ltr/sqm over prepared roof surfaces, forcing overlap with a propane or a butane gas torch with a overlap of 100mm at sides & 100mm at ends & sealing as per manufacturer"s instructions including two coat(i.e 0.2 ltr/Sqm) of aluminium paint entaire treated surface. Note :- 1. Water proofing treatment shall be got carried out by the manufacturer or their authorised applicator only. 2. Bitumen primer, bitumen and membrane shall be of same make/manufacturer. ( Note: height of building upto 04 story).
33M&L for cutting groove in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement Mortar 1:3 for fixing of APP membrane and filling the groove with PCC 1:2:4 type B0 using 12.5mm graded stoen aggregate after inserting membrane complete all as specified and directed.
34M&L 15mm bore GI tubing medium grade with all fittings and fixed complete to walls, ceiling or laid in floorincluding taking up or down old steel tube complete all as spd and directed.
35All as per item no. 34 above but 20 mm bore tubing.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail