Tender For Comprehensive Preventive And Periodical Maintenance Of Ibms Work And Security And Surveillances System Work At National War Memorial India Gate New Delhi, delhi-Delhi

Military Engineer Services-MES has published Tender For Comprehensive Preventive And Periodical Maintenance Of Ibms Work And Security And Surveillances System Work At National War Memorial India Gate New Delhi. Submission Date for this Tender is 22-05-2024. CCTV System Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43337370
Corrigendum : Tender For Comprehensive Preventive And Periodical Maintenance Of Ibms Work And Security And Surveillances System Work At National War Memorial India Gate New Delhi
Open Tender
Indian
Delhi
delhi
22-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Comprehensive Preventive And Periodical Maintenance Of Ibms Work And Security And Surveillances System Work At National War Memorial India Gate New Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-May-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 99000.0 /-
Tender Value
INR 49.50 Lakhs /-

Attachment

FileName File Description File Size
2d35f60a-d64a-4f3b-84c5-c505b5281103.html Tender Notice 0 KB
BOQ_730995.xls Tender Document 0 KB
TENDER.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of works: - COMPREHENSIVE, PREVENTIVE AND PERIODICAL MAINTENANCE OF IBMS WORK AND SECURITY & SERVILLANCES SYSTEM WORK AT NATIONAL WAR MEMORIAL INDIA GATE NEW DELHI.
Sl. No. Item Description
1Taking out of Automatic Bollard consisting of obstacles of 275 mm dia, 6 mm thick brushed stainless steel with a height of 600 mm above the ground, servicing and refixing the same all as specified and as directed by Dy Project Director.
2Supply and fixing in repair Bollard pump complete all as specified and as directed by Dy Project Director.
3Supply and fixing in repair Bollard male female connector complete all as specified and as directed by Dy Project Director.
4Supply and filling of Haudraulic Bollard oil as per existing make Neptune Faac complete all as specified
5Supply and fixing in repair J275-600 Bollard Piston seal kitcompleteall as specified and as directed by Dy Project Director.
6Supply and fixing in repair 624 BLD Control card for bollard completeall as specified and as directed by Dy Project Director.
7Supply and fixing in repair 16 MFD Capacitor for bollard completeall as specified and as directed by Dy Project Director.
8Supply and fixing in repair LED for bollard completeall as specified and as directed by Dy Project Director.
9Supply and fixing in repair Cross for bollard completeall as specified and as directed by Dy Project Director.
10Supply and fixing in repair J275-600 Bollard Pump (complete hydraulic unit) completeall as specified and as directed by Dy Project Director.
11Supply and fixing in repair Limit switch kit for bollard completeall as specified and as directed by Dy Project Director.
12Supply and fixing in repair Solenoid valve completeall as specified and as directed by Dy Project Director.
13Visit of the Engineer/ Commissioning Enginner/BMS Expert for checkingUnder Vehicle Surveillance System and BMS,PA Eqpt and CCTV system for checking of software and hardware problems & surveying of the whole system and to generate the report of the visit. Report shall indicates if any major repair/repair needed along with the cost impact which will be catered separately as per direction of Dy Project Director.(Cost incl. only visit and report generation ) Notes: Visit shall be done once in a three month or as directed by Dy Project Director
14Supply, Installation, Testing and Commissioning Graphical Softwareproviding the facility to create / provide the following, static and animate the Graphics, Navigation between pages, display of logs, changing the time zones; the BMS platform shall natively support standard communication protocols such as Lontalk and Modbus / BACnet and the software shall be Web Based Software required to remotely monitor the system for 5 concurrent users & shall have inbuilt email facility (without using any external software / hardware) to send critical alarms to users with and including all the components and accessories mentioned above and also complying with all the requirements mentioned here-in and in the Particular Specifications, complete all as specified and as directed by Dy Project Director. Note for Sl. Item No. 14 here-in-before: - The unit rate quoted shall be deemed to include for the complete set of Graphical Software with all components and accessories as mentioned above comprising of all the items and complying with all the requirements and specifications as described above and in Particular Specifications and all as directed by Dy Project Director.
15Supply, Installation, Testing and Commissioning in repair of necessary Hardwares, Gateway / Router / Converter / Softwares for Integrating it with the 3rd party Devices on Bacnet / Modbus / Lonworks complete all as specified and as directed by Dy Project Director.
16Supply, Installing, Testing and Commissioning Immersion type pipe mounted water flow switch of paddle type wth NO/NC Contacts complete all as specified and as directed by Dy Project Director.
17Supply, Installing, Testing and Commissioning Upper / Medium / Lower level switches for tanks with setting options at different levels as required and 3 NO/NC Contacts complete all as specified and as directed by Dy Project Director.
18Supply, Installing, Testing and Commissioning Indoor display type wall mounted temperature cum humidity sensor, Room Temperature sensor shall be with 4-20 mA transmitters, the temperature measurement range shall be 0 deg C to 50 deg C, ± 0.2 deg C, room RH sensor shall be of range 0 to 95% non condensing, accuracy of RH sensor shall be ± 3% RH complete all as specified and as directed by Dy Project Director.
19Supply, Installation, Testing and Commissioning in repair of PoE Managed Ethernet switch : 24port RJ45 10 / 100 / 1000 Base T or 24 ports of fibre (MM) complete with SFP (Small formfactor pluggable) with 2 Uplink Fibre Ports complete with SFP, (shall be used for BMS System also), 24 port patch panels, fully loaded complete with patch cords and required hardware, wire managers, labelling and accessories complete all as specified and as directed by Dy Project Director. Note- The unit rate quoted shall be deemed to include for all the components and accessories as mentioned above comprising of all the items and complying with all the requirements and specifications as described above and in Particular Specifications and all as directed by Dy Project Director.
20Providing, Installing, Testing and Commissioning in repair of filed mounted Programmable and Application Specific Controllers of the following configurations, comprising of and including following components and accessories and complying with the following specifications all as directed by Dy Project Director: - (a) The programmable controller processors shall be 32-Bit, 50 MH, LONchip BACnet Compatible. (b) The DDC Controllers shall be on BACnet & UL listed. (c) The DDC controller shall be as per the I/O Summary. (d) Main DDC Controller shall have atleast 21 Input / Output points (e) The above controllers shall be housed in a vandal proof, lockable and secure MS cabinets to be supplied alongwith the Controllers as per manufacturer design and specifications.The Control Panel shall be IP66 protection standard for mounting theDDCs, with Base Plate, Cable Truf, Glands for Cable Entry, transformer, relays, Fan, MCBs, Switches and other accessories with all other mounting accessories complete as required. Note: - The unit rate quoted shall be deemed to include for the complete set with all components and accessories as mentioned above comprising of all the items and complying with all the requirements and specifications as described above and in Particular Specifications and all as directed by Dy Project Director.
21Taking out of 42" Flat LED Color Monitor of make LG and carrying out to LG service centre for servicing/repair/ repair of unserviceable part & refixing the same after rectification of defectcomplete all as specified and as directed by Dy Project Director.
22Supply, Installation, Testing and Commissioning Volume Controller for all the closed areas complete all as specified and as directed by Dy Project Director.
23Supply, Installation, Testing and Commissioning in repair of 6W multitap voice alarm speaker, wall mountable BS 2839 Part 8, line voltage 100 V complete all as specified and as directed by Dy Project Director.
24Supply, Installation, Testing and Commissioning in repair of 15W Outdoor Horn speakers,line voltage 100 V complete all as specified and as directed by Dy Project Director.
25Taking down and repair of Day and Night bullet camera with IP66,IK10 rated vandal-resistantVarifocal 3-10 mm P-Iris lens, remote focus and zoom; Multiple, individually configurable H.264 and Motion JPEG streams; max HDTV 1080P resolution at 30 fps, WDR more than 70 dB,including mounting bracket for wall / ceiling / Pole or junction boxesand refixing the same after rectification the defectcomplete all as specified and as directed by Dy Project Director.
26Taking down and repair of 360 degree Outdoor Dome IP Camera Panoramic with mini 5 Megapixel Sensor with 4 Megapixel resolution output with 10 FPS on full resolution, support SD card upto 128GB H.264 with high profile compression andrefixing the same after rectification the defect complete all as specified and as directed by Dy Project Director.
27Supplying, Laying and Testing in repair ofCat 6 UTP cable for CCTV and BMS System with all terminations crimping etc. complete all as specified and as directed by Dy Project Director.
28Supplying, Laying and Testing in repairMM Optical Fibre cable of 6 core (Armoured) with all terminations, crimping etc. complete all as specified and as directed by Dy Project Director.
29Supplying, Laying and Testing in repair Wiring for PA system using 1.5 sq. mm. size two core FRLS insulated copper conductor cable in existing surface / recessed conduit complete as required, all as specified and as directed by Dy Project Director.Make-Havells,Polycab
30Supplying, Laying and Testing in repair PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cable (heavy duty) with stranded copper conductor of size 1.5 Sq. mm. 2 core 1100 Volts grade (for Signal, DDC communication, Third-party integration cable)
31Supply and fixing in repair of Network Switch as per existing make and model complete all as specified and directed by Dy Project Director
32Supply and fixing in repair Optical Fiber Patch Cord complete all as specified and directed.
33Supply and fixing in repair CAT 6 Patch Cord complete all as specified and directed.
34Supply and fixing in repair Camera Stand complete all as specified and directed.
35Supply and fixing in repair Camera Mounting Pole complete all as specified and directed.
36Supply, Installation, Testing and Commissioning in repair 32 channel NVR, Pre-installed, pre-configured IP storage solution with VMS license having 24 TB storage capacity, boosted by the High-end processor and 8 GB RAM, DSSRV2 NVR providing an optimal combination of processing installed, 2U rack mount, temperature +100C to +350C, relative humidity-8 to 90% (non-condensing), CE, UL Certified, the recording shall be calculated for all cameras for 30 days as required as per specifications & at site of work all as directed by Dy Project Director. Note - The unit rate quoted shall be deemed to include for all the components and accessories as mentioned above comprising of all the items and complying with all the requirements and specifications as described above and in Particular Specifications and all as directed by Dy Project Director.
37Repair ofUnder Vehicle Surveillance System having speed bump design, complete with hardware, with and including repair 4 Nos. ofCCD / CMOS Area Scan cameraswith IR bright white illumination LEDs integrated in a single module, chaceking ofAutomated Number plate reading system, digital video recorder with built in Multiplexer and UVSS Software, Multilingual Graphical user interface (GUI), Inductive loop sensor, IP-67 Standard etc. as required and also including fixing within the road complete all as specified and as directed by Dy Project Director. Note 1.Minor spares costing each up to Rs 500 shall be deemed included in the rate quoted above. 2. Any spares parts required to be replaced shall be measured and paid for separately under respective items.
38Supply and fixing in repair Maintenace free bty for UPS 12V, 150Ah as per existing make and model-Exide FXP5-XP 1000 type complete all as specified and directed.
39Rifilling of Existing Carbon Dioxide fire extinguisher capacity 4.5Kgs installed in various location at National War Memorial complete all as specified and as directed by Engr-in-Charge.
40Supply and Fixing in repair of sealed lead acid battery 12V 42 Ah Make- Exide EP 42-12 type
41Taking down cameras, lighting, UPS, POE switch for Anti Sabotage check and refixing the same after scanning & security checking complete
42supplying & fixing 3000 VAmicrotek ups for 30 min back up complete including installation of batteries ( except cost of batteries which shall be measured separately ) all as per directions of engineer in charge at the specified location.