Dakshinanchal Vidyut Vitran Nigam Limited-DVVNL has published Tender For Increasing Capacity Of D. Transformers/ Additional Dt Installation Works Under Business Plan 2024-25 In The Area Of Edc Ii, Mathura On Semi Turnkey Basis. Submission Date for this Tender is 20-05-2024. Transformer Supply Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 14-May-2024 | Extension of Date | Date | 17-05-2024 |
2 | 17-May-2024 | Extension | Date | 20-05-2024 |
FileName | File Description | File Size |
1b789296-131b-4e9f-8cd0-bfed00f8431e.html | Tender Notice | 0 KB |
BOQ_1596540.xls | Tender Document | 0 KB |
Technicaldocuments3.rar | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | Supply of following material against various proposed works as per RESPO Drawings/approved GTP/standard technical specifications |
2 | Stone pad |
3 | Tee-off channeal with clamp & B&N |
4 | Earthing Complete |
5 | Stay Complete |
6 | H.T. Tee connection with Ex Mains/Sub Station with (Tee channel) |
7 | 3-Phase D.O. Fuse Set |
8 | Tail less unit complete with Structure |
9 | Top channel (125x65x2240mm) |
10 | Dropper Channel (100x50x2028mm) |
11 | M.S. Angle (75x75x6x2028mm) (T/F Base) |
12 | Clamp for PCC with nut & Bolt |
13 | TF Clamp with Bolt nut |
14 | LT Shackle insulator |
15 | LT Clamp with Bolt nut |
16 | Eye Hook with Eye Bold AB Conductor |
17 | Piercing Connector |
18 | Distribution Box-3 Phase |
19 | Distribution Box Holding Clamp |
20 | Suspenstion Clamp |
21 | Copper L Piece 50*50*6 MM |
22 | 3 Phase 11 kv DO Fuse Set Heavy Duty. |
23 | ACSR Insulated Weasal for jumpering |
24 | LT Protection Panel with 3 No. of Ckt by stud type tell less fuse unit compatable for installation of MCCB 1000 Amp. |
25 | All lugs 400 sqmm |
26 | Clamp angle for panel mounting support |
27 | Danger Board with Calmp N/B |
28 | Number Plate with Clamp N/B |
29 | Nut & Bolt with washer |
30 | L.T. Cable of size 3.5 x 240 Sqmm |
31 | L.T. Cable of size 3.5 x 150 Sqmm |
32 | L.T. Cable of size 3.5 x 120 Sqmm |
33 | Fixing, erection and commissioning work of following material for 11/0.4 KV TF increasing capacity works/ additional TF installation work as per RESPO Drawings/Estimates. Work includes all cartage/carriage, T&P, and any other work which is required for completion of above said work as per satisfaction of supervisory engineer. |
34 | Pcc pole 8.5 Mtr. Long |
35 | Stone pad |
36 | 11 kv pin insulator with pin complate |
37 | 11 kv Polymer Disc insulator 45 KN with disc |
38 | Tee-off channeal with clamp & B&N |
39 | ACSR Weasal Conductor |
40 | Earthing Complete |
41 | Stay Complete |
42 | H.T. Tee connection with Ex Mains/Sub Station with (Tee channel) |
43 | 3-Phase D.O. Fuse Set |
44 | Tail less unit complete with Structure |
45 | Top channel (125x65x2240mm) |
46 | Dropper Channel (100x50x2028mm) |
47 | M.S. Angle (75x75x6x2028mm) (T/F Base) |
48 | Clamp for PCC with nut & Bolt |
49 | T/F KVA 100 KVA Additional |
50 | T/F KVA 63 KVA Additional |
51 | T/F KVA 25 KVA Additional |
52 | T/F KVA 16 KVA Additional |
53 | TF Clamp with Bolt nut |
54 | LT Shackle insulator |
55 | LT Clamp with Bolt nut |
56 | ABC 3x95 Sq. mm cable |
57 | Eye Hook with Eye Bold AB Conductor |
58 | Piercing Connector |
59 | Distribution Box-3 Phase |
60 | Distribution Box Holding Clamp |
61 | Suspenstion Clamp |
62 | Copper L Piece 50*50*6 MM |
63 | 3 Phase 11 kv DO Fuse Set Heavy Duty. |
64 | ACSR Insulated Weasal for jumpering |
65 | LT Protection Panel with 3 No. of Ckt by stud type tell less fuse unit compatable for installation of MCCB 1000 Amp. |
66 | 1x400 Sqmm LT PVC Cable Singel Core |
67 | All lugs 400 sqmm |
68 | Clamp angle for panel mounting support |
69 | Danger Board with Calmp N/B |
70 | Number Plate with Clamp N/B |
71 | Nut & Bolt with washer |
72 | Increasing Transformer 250 KVA (100 kva to 250 kva) |
73 | Increasing Transformer 100 KVA (63 kva to 100 kva)only commissioning and other related works are to be done, carriage of transformer is not to be done |
74 | L.T. Cable of size 3.5 x 240 Sqmm |
75 | L.T. Cable of size 3.5 x 150 Sqmm |
76 | L.T. Cable of size 3.5 x 120 Sqmm |
77 | Increasing Transformer 63 KVA (25 kva to 63 kva)only commissioning and other related works are to be done, carriage of transformer is not to be done |
78 | 11KV XLPE CABLE SIZE 3*70 |
79 | 11/0.4KV 400KVA (COPPER wind) TF complete installation on trolly |
80 | 11KV XLPE JOINTING KIT OUTDOOR |
81 | completion of following work with all material, cartage/carriage, T&P, and any other required work for 11/0.4 KV TF increasing capacity works/ additional TF installation work as per RESPO Drawings/standard specifications/Estimates/as per satisfaction of supervisory engineer. |
82 | Concreting of pole |
83 | concreting of stay |
84 | Water level Pipe Earthing of Panel"s Neutral & TF Neutral & body |
85 | Chemical Earthing Panel body & fencing |
86 | Foundation of LT Protection Panel 30 cm Hieght |
87 | Painting of Fencing with red oxide & green paint |
88 | Painting of pole with red oxide, al paint & post office Paint |
89 | Interlocking of base in transformer area |
90 | Ganular sub base for laying of interlocking bricks |
91 | Toe wall for fencing |
92 | Reaparing of Plinth if required |
93 | Miscellaneous Lug, Clamp, Washer, Nut, Etc. |
94 | T/F Plinth |
95 | T/F Fencing |
96 | T/F Earthing |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy