Military Engineer Services-MES has published Tender For Special Repair Replacement Of Ac Plant Against Ber In Cr And Ss At Air Force Station Gorakhpurgorakhpur. Submission Date for this Tender is 03-06-2024. HVAC Tenders in gorakhpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43334513
Tender For Special Repair Replacement Of Ac Plant Against Ber In Cr And Ss At Air Force Station Gorakhpurgorakhpur
Open Tender
Indian
Uttar Pradesh
gorakhpur
03-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Special Repair Replacement Of Ac Plant Against Ber In Cr And Ss At Air Force Station Gorakhpurgorakhpur

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

Attachment

FileName File Description File Size
4256103a-f6fc-4ae7-bd50-1c69dba72157.html Tender Notice 0 KB
87362TENDER.pdf Tender Document 0 KB
BOQ_730804.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

NAME OF WORK: SPECIAL REPAIR/REPLACEMENT OF AC PLANT AGAINST BER IN CR&SS AT AF STATION GORAKHPUR
Sl. No. Item Description
1Demolition of brick work built in cement mortar including all quoins , arches,pillar etc complete all as specified and as directed.
2Taking down cement plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
3Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but not exc 4 sqm each complete all as specified and as directed
4Demolition of unreinforced cement Concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level etc) complete all as specified and as directed.
5Dismantling wall and ceiling boards any thickness including wooden cover fillets or aluminium frame work complete all as specified and as directed.
6Dismantling floor hearth or wall tilling including cement mortar bedding but not backing , removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
7M&L brick work withold size sub class "B" bricks straight or curved on plan exceeding 6 m mean radius builtin cement mortar 1:6 complete all as specified and as directed.
8M&L 15 mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces, surface finished even and fair complete all as specified and as directed.
9M&L applying two coats of oil emulsion distemper over one coat of alkali resistant primer incuding preperation of newly plastered surfaces of wallcomplete all as specified and as directed.
10S&F Structural steel work as in crane, gantries,rail and fastenings and heavy bracket framing including cleat etc conforming to FE-410 W Gde B-250 quality-A complete all as specified and as directed.
11M&L applying two coats of synthetic enamel paint over one coat of redoxide primer including preperation of new steel surfaces of any description over 10 cm width or girth complete all as specifed and as directed.
12S&F 605mmx605mmanodised aluminium snap grid frame work for false ceiling with hangers 6 mm dia upto 1200 mm length, adjusting level fixed to roof slab by means of ceiling cleat made out of galvanised iron flat 40mmx3mm ssssssize 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long and supply and fixing 4 mm thick non asbestos fibre cement building boards on aluninium frame work complete all as specified and as directed.
13M&L second class hardwood plain ,solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints complete all as specified and as directed.
14S&F mild steel work as in holdfast,wall ties,clamp, and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
15S&F 35 mm thick flush shutter ,solid core construction,with block board core and plywood face panels, commercial type on both side complete all as specified and as directed.
16S&F 200 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified
17S&F 150 mm size aluminium handle,cast type, anodisedcomplete all as specified and as directed.
18S&F 100 mm size , butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and as directed.
19M&Lapplying two coats of synthetic enamel paint over one coat of pink primer including preperation of new wooden surfaces ofany description over 10cm in width or girth not otherwise described complete all as specified and as directed.
20S&F 250 mm long aluminiumaluminium alloy,anodised sliding bolt with hasp and staple(bolt type) and fixing clips of sheet,cast or extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and as directed.
21M&L for Glazed ceramic coloured tiles of size 350mmx250mmx7mm or 450mmx350mmx7mm as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade tile over and inclduing 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
22M&L for7-8 mm thick Non Skid ceramic tilescoloured (square/ rectagular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc. setand jointed in neat cement slurry and pointed in white or coloured cement to match over andincluding 15mmthick screed bed in cement mortar 1:4 complete all as specified and as directed.
23M&L pre-polished machine cut kota stone slab flooring 18-20 mm thick over 15 mm thick cement screed base in cement mortar 1:4 laid and jointedwith grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.
24M&L 100 mm thick cement concrete 1:2:4 type B-2 using 40 mm graded stone aggregateas in hardstanding/pavement etc, surface finished even and faircomplete all as specified and directed.
25M&L applying two coats of oil emulsion distemper over one coat of 1 mm thick wall care putty incuding preperation of olddecorated plastered surfaces of wallcomplete all as specified and as directed.
26Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
27M&L point wiring with single corePVC sheathedmulti stranded FRLSH copper conductor of size 1.5 Sqmm drawn through and including concealed non metallic rigid PVC conduit medium grade ISI markednot less than 20mm diawith modular metal flush box, 1.6 mm thick of suitable size and modular white cover plate with frame of suitable module and wiring to be terminated in pressed steel sunken boxes including all accessories and1.5 Sqmm PVC sheathedstrandedFRLSH copper conductor cable as continuous earth wire and connected to main earth dolly complete all as specified and directedfor one light/Fan/ bell point controlled by one Switch.
28Description same as peritem No 27 above but for one power point 3/5 pin 15 Amps socket out letindependent board using 2.5 Sqmm multi stranded PVC insulated copper conductor cablewith 2.5 Sqmm multi stranded PVC insulated FRLSH copper conductor cable as earth wire complete, all as specified and as directed.
29M&L for Switch piano, flush type single pole, one way 6 Amp complete all as specified and as directed..
30M&L Socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type, complete all as specified and asdirected.
31M&L for Switch piano, flush type single pole, one way 16 Ampcomplete all as specified and as directed.
32S&Fceiling rose ,3 phase PVC or poycarbonate,isolated body complete all as specified and as directed.
33Taking down old and unserviceable light fittings conventional type from wall surface or ceiling or any position and making good the disturbed surfaces complete all as specified and as directed.
34S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed..
35Taking down ceiling fan by unscrewing nuts , bolts, disconnection of electric cable from ceiling rose, ceiling cable end,removing blades of any sweep and make and deposiingt to MES Store yard complete all as specified and as directed.
36S&F Modular Fan step regulator, 120W - 2 module complete all as specified and as directed.
37S&F ceiling fan 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush less direct current (BLDC) motor, class of insulation : B, 3 nos. blades, 30 cm long down rod, 2 No canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value ( CMM/W) minimum 6.00, Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374 - 2019), THD less than 10 % ,electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V , 50 Hz, single phase AC supply, earthing etc including necessary connection from ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable and including writing MES No complete all as specified and as directed.
38S&Fexhaust fan made of steel body complete with louvers shutters , 300 mm sweep, single phase, 230 Volts AC, ISI marked fixed properly at directed location with provisioning of suitable fixing/tighteningarrangements , connecting, testing including writing MES No complete all as specified and as directed.
39Dismanting and removingexisting unserviceable central air conditioning AC plant complete of 2 X 10 TR capacity units with compressor, compressor motor, condenser, condenser water pump chiller with motor and all connection water pipe lines, cooling tower, AHU and ducting electrical control panel etc including depositing in MES store yard and making good disturbed surfaces of floor, roof etc complete all as specified and as derected.
40Supply ,Installation, testing and commissioning of Air cooled ducted package air conditioning unit of 11.5TR available nearest to 10 TR Twin circuit (5500 CFM) capacity comprising of Imported scroll compressor , Dx evaporator coil, thermostatic expansion device , air-cooledcondensers with specially cast fins centrifugal blower , TEFC motor , microprocessor based control panel alongwith built in UVGI system thereafter ensure vireus free and safe interiors etc. All items shall be in closed in sheet metal cabinets. AC units should be 100% efficient on 43 Degree Celcius ambient Temperature complete all as specified and as directed.
41Supply, fixing, testing and commissioning of interconnecting refrigerant pipe work with (19 mm / 13 mm thick) XLPE polythlene insulation between each set of indoor & outdoor units as per specifications andall piping inside the room shall be properly supported with MS hanger as per manufacturer"s instruction complete all as specified and as directed. Note:-Single run gas and liquid line with insulation shall be measured as one unit length..
42Supply and charging of refrigerant gas R-410 A complete all as specified and as directed.
43S&F of rigid PVC piping complete with fitting support as per direction of Engineer-in-charge duly insulated with 6 mm thick XLPE polyethylene insulation as per manufacturer"s instruction complete all as specified and as directed.
44S&F of control cum transmission wiring of 2 core 2.5 Sqmm copper in suitable conduit between indoor and outdoor unit between corded remote and indoor unit complete all as specified and as directed.
45S&F 22 gauge galvanised iron factory made ducting along with all proposed hanger vans splitters neoprene gasket for zero leakage all as per SMACNA complete all as specified and as directed.
46S&F 24 gauge galvanised iron factory made ducting along with all proposed hanger vans splitters neoprene gasket for zero leakage all as per SMACNA complete all as specified and as directed.
47S&F of insulation of XLPE polythlene / nitrile rubber insulation, thickness 9 mm thick with proper adhesive on duct complete as per manufacturer"s instruction complete all as specified and as directed.
48S&Fof duct acoustic lining 10 mm thickwith armasound complete all as specified and as directed.
49M&L SITC of Fire retardant duct canvas connection with fitting flange supports all accessories as per manufacturer"s instruction complete all as specified and as directed.
50M&L Powder coating on Oval duct (minimum thickness of powder coating not less than 50 miron) complete all as specified and as directed.
51S&Fof aluminiumGrill/Diffuser with damper complete all as specified and as directed.
52S&Fof Jet nozzle diffuser with damper complete all as specified and as directed.
53S&Fof Collar Damper complete all as specified and as directed.
54S&F of aluminium Supply Grill/Diffuser with damper complete all as specified and as directed.
55S&F of aluminium powder coated fresh air/exhaust air lovers with bird screen as per standard Engineering practice complete all as specified and as directed.
56Supply only mild steelstand and supportof size and shape as decided by Engineer-in-charge including applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
57Use and waste of scaffolding workrequired at site for height work for entire execution of work complete all as specified and as directed..
58M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.50 Mbelow ground level connected to glavanised mild steel strip of size 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steelconnected to earthing test point all as specified including 40 mm GI tubing medium grade and necessary fitting for protection of GI strip including filling of charcoal dust and common salt in alternate layer, PCC Pitin 1:3:6 type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick 1:2:4 type B-0 using 12.5mm graded stone aggregate reinforced with 8 mm dia round bar @ 150 mm C/C both ways with MS handle 8mm dia, plastering 15mm thick cement mortar 1:6 externally upto 150mm below ground level , GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh including necessary excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and testingon completion
59M&L for LT Panel Feeder pillar box with outer and inner compartments LT out door including bus bar chamber dust proof vermin proof fabricated out of 1.8 mm thick mild steel sheet of suitable size Including painting with two coat of synthetic enamel paint coat a coat of red oxide primer and mounted on angle iron frame of 50 mm x50mmx 6mm with 60cm long legs and 30 cm embedded in ground and comprising of supply and fixing offollowing accessories:- (i) Digital Ammeter including selector switch-01No (ii) CT of required capacity -03No. (iii) Digital Voltmeter including selector switch-01 No (iv) Phase indicating lamps – 03 No (v) Complete control wiring with copper conductor (vI) Bus bar strip made out of copper of 300 amps capacity mounted on insulators. (vii) MCCB 3 pole 415 V, 160 Amp capacity, 36KA-01No (for incoming) (viii) MCCB 3 pole 415V,125Amp capacity, 36KA-02No. (for outgoing) (ix) MCCB 3 pole 415V,100 Amp capacity, 36KA-01 No. (for outgoing) (x) On load Change over 250 Amp, 4pole- 01 No (xi)ON/Off indicator lamp LED cluster type (Set of 03) - 01 set
60S&F Planum 22 gauge as per manufacturer"s instruction complete all as specified and as directed.
61Supply ,Laying and testingof cable XLPE insulated, screened, PVC bedded,,galvanizedsteel strip or wire armored electric power cable( heavy duty) 1100 volts grade with aluminium conductor of size 95 sqmm 3.5 corefixed on wall/ cable tray complete all as specified and as directed.